• Title/Summary/Keyword: removal of column

Search Result 543, Processing Time 0.026 seconds

Decolorization and organic removal characteristics of a SBR process combined with zero-valent iron column (ZVI (Zero-Valent Iron)를 조합한 SBR 공정의 색도 및 유기물 제거 특성)

  • Choi, YoungGyun;Park, ByungJu;Kim, SeongHong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.431-438
    • /
    • 2009
  • The purpose of this study was to evaluate the performances of zero-valent iron (ZVI) combined SBR (Z-SBR) process in decolorization and organic removal of synthetic dye wastewater. The batch test for optimizing the operation parameters of ZVI column showed that the appropriate EBCT was around 11 min and the pH of the dye wastewater was below 7.0. During the step increase of influent color unit from 300 to 1,000cu, about 53 to 79% decolorization efficiency could be achieved in control SBR (C-SBR, without ZVI column), which resulted from destroying azo bond of synthetic dye in anaerobic condition. For the same influent color loading, Z-SBR showed always higher decolorization efficiency than C-SBR with an aid of ZVI reducing power. The TCOD concentration in Z-SBR effluent was 20-30mg/L lower than C-SBR effluent although the TCOD before and after ZVI column was nearly same. It means that breakdown of azo bond by ZVI reducing power could increase biodegradability of synthetic dye wastewater.

Removal of Manganese(II) from Aqueous Solution Using Manganese Coated Media (망간코팅 여재를 이용한 수용액상의 망간 제거연구)

  • Kim, Seok-Jun;Kim, Won-Gee;Lee, Seung-Mok;Yang, Jae-Kyu
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.454-459
    • /
    • 2010
  • This study investigated the applicability of manganese coated media such as manganese coated sand (MCS), manganese coated sericite (MCSe) and manganese coated starfish material calcined at $550^{\circ}C$ (MCSf) to remove Mn(II) in synthetic wastewater. Manganese coated media prepared at different pH was applied in the treatment of soluble Mn(II) in batch and column experiments at various Mn(II) concentrations. The amount of Mn coated on three different media was approximately 800~1100 mg/kg. From the stability test, negligible dissolution of Mn was observed above pH 3.0. In batch test, more than 40% of Mn(II) was removed by all sand media at various manganese concentrations. In order to see the effect of additional oxidant for the removal of Mn(II), 4 mg/L of hypochlorite was added in Mn(II) solution during column experiment. Breakthrough of Mn(II) was greatly retarded in the presence of hypochlorite in all column reactors packed with different media. Among the manganese coated media, MCSf prepared at pH 4 indicated the highest removal capacity. The removal efficiency of Mn(II) was also increased in the multi-layer system (0.5 g of MCS, MCSe, and MCSf each).

Basic Study for Development of Denitrogenation Process by ion Exchange(II) (이온교환법에 의한 탈질소 공정개발의 기초연구(II))

  • 이민규;주창식
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.89-95
    • /
    • 1998
  • Ion exchange performance to remove nitrate in water was studied using commercially available strong base anion exchange resin of Cl- type in the batch and continuous column reactors. The performance was tested using the effluent concentration histories for continuous column or equilibrium conquilibrium between resin and solution. Anion exchange resin used in this study was more effective than activated carbon or zeolite for nitrate removal. With large resin amount or low initial concentration, nitrate removal characteristics for a typical gel-type resin was Increased. On considering the relation between the breakthrough capacity and nitrate concentration of the influent, the use of anion exchange resin were suitable for the hi선or order water treatment. The nitrate removal of above 90% could be possible until the effluent of above 650 BV was passed to the column. Thus, the commercially available strong base anion exchange resin of $Cl^-$ type used in thins study could be effectively used as economic material for treatment of the groundwater. The breakthrough curves showed the sequence of resin selectivity as $SO_4^{2-}$ > $NO_3$ > $NO^{2-}$ > $HCO_3^-$. The results of this study could be scaled up and used as a design tool for the water purification system of the real groundwater and surface water treatment processes.

  • PDF

Removal of Cadmium Ion (Cd2+) by Pseudomonas aeruginosa Immobilized in Ca-Alginate Gel Beads in Packed-Bed Column Reactor (충전층 반응기내에서 고정된 Pseudomonas aeruginosa에 의한 Cd2+의 제거)

  • Choi, Kwang Soo;Kim, Chul Kyung
    • Clean Technology
    • /
    • v.8 no.4
    • /
    • pp.217-222
    • /
    • 2002
  • The effects of initial cadmium ion concentrations (50, 100, 200, 300ppm), and feeding velocities (30, 45, 60mL/hr) on the removal ratio of cadmium ion by Pseudomonas aeruginosa ATCC 27853 immobilized in Ca-alginate gel beads in a packed-bed column reactor were investigated at operating temperature $37^{\circ}C$. The removal ratio of cadmium ion with variable initial concentration was decreased in the following order : 50ppm > 100ppm > 200ppm > 300ppm. The optimum removal conditions of cadmium ion by Pseudomonas aeruginosa ATCC 27853 were initial concentration 50ppm, feeding velocity 30mL/hr.

  • PDF

Measurement of Gas-Accessible PCE Saturation in Unsaturated Soil using Gas Tracers during the Removal of PCE (토양 내 PCE 제거과정에서 가스 분배추적자기법을 이용한 공기노출 PCE의 잔류량 검출)

  • Kim, Heon-Ki;Kwon, Han-Joon;Song, Young-Soo
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.5
    • /
    • pp.42-52
    • /
    • 2011
  • In this laboratory study, the changes in gas-exposed perchloroethene (PCE) saturation in sand during a PCE removal process were measured using gaseous tracers. The flux of fresh air through a glass column packed with PCEcontaminated, partially water-saturated sand drove the removal of PCE from the column. During the removal of PCE, methane, n-pentane, difluoromethane and chloroform were used as the non-reactive, PCE-partitioning, water-partitioning, and PCE and water-partitioning tracers, respectively. N-pentane was used to detect the PCE fraction exposed to the mobile gas. At water saturation of 0.11, only 65% of the PCE was found to be exposed to the mobile gas prior to the removal of PCE, as calculated from the n-pentane retardation factor. More PCE than that detected by n-pentane was depleted from the column due to volatilization through the aqueous phase. However, the ratio of gas-exposed to total PCE decreased on the removal of PCE, implying gas-exposed PCE was preferentially removed by vaporization. These results suggest that the water-insoluble, PCE-partitioning tracer (n-pentane in this study), along with other tracers, can be used to investigate the changes in fluid (including nonaqueous phase liquid) saturation and the removal mechanism during the remediation process.

Removal of Benzene-NAPL in Soil Column by Cosolvent Flooding (Cosolvent에 의한 토양 내 Benzene-NAPL 세정 연구)

  • Song, Chung-Hyun;Jeong, Seung-Woo;Lee, Byung-Jin;Go, Sung-Hwan
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.3
    • /
    • pp.45-51
    • /
    • 2008
  • Removal of nonaqueous phase liquid present in the soil column by using cosolvent floods was investigated. The first objective of the study was to elucidate the removal mechanism of cosolvent flooding for benzene-NAPL. The second objective of the study was to evaluate the effects of the alchohol partitioning type (NAPL swelling and non-swelling) and concentration on NAPL removal efficiency from the soil column. The main NAPL removal mechanism of swelling alcohol was mobilization, while that of non-swelling alcohol was NAPL dissolution. The NAPL removal efficiency of swelling alcohol was more effective than that of non-swelling alcohol. Removal of Benzene NAPL entrapped in the soil would be effective under the cosolvent flood condition of alcohol content greater than 40% in volume.

A Simulation Study on the Carbon Dioxide Removal Process Using Aqueous Amine Solution in the GTL Process (GTL 공정에서 아민 수용액을 이용한 이산화탄소 제거공정의 전산모사에 대한 연구)

  • Cho, Jung-Ho;Lee, Ji-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3334-3340
    • /
    • 2011
  • In this study, a computer simulation work has been performed for the carbon dioxide removal process using aqueous amine solution in the GTL (Gas To Liquids) process. 30wt% DEA(diethnaol amine) aqueous solution was utilized as a carbon dioxide remvoal agent and an absorber-stripper two-columns configuration was used. Kent-Eisenburg modeling equation built-in amine specicial package was used for the modeling of the carbon dioxide removal process. PRO/II with PROVISION 9.0, a commercial process simulator was used. Through this simulation study, heat and material balance was obtained and packing column diameter and column height were also estimated.

Cap truss and steel strut to resist progressive collapse in RC frame structures

  • Zahrai, Seyed Mehdi;Ezoddin, Alireza
    • Steel and Composite Structures
    • /
    • v.26 no.5
    • /
    • pp.635-647
    • /
    • 2018
  • In order to improve the efficiency of the Reinforced Concrete, RC, structures against progressive collapse, this paper proposes a procedure using alternate path and specific local resistance method to resist progressive collapse in intermediate RC frame structures. Cap truss consists of multiple trusses above a suddenly removed structural element to restrain excessive collapse and provide an alternate path. Steel strut is used as a brace to resist compressive axial forces. It is similar to knee braces in the geometry, responsible for enhancing ductility and preventing shear force localization around the column. In this paper, column removals in the critical position at the first story of two 5 and 10-story regular buildings strengthened using steel strut or cap truss are studied. Based on nonlinear dynamic analysis results, steel strut can only decrease vertical displacement due to sudden removal of the column at the first story about 23%. Cap truss can reduce the average vertical displacement and column axial force transferred to adjacent columns for the studied buildings about 56% and 61%, respectively due to sudden removal of the column. In other words, using cap truss, the axial force in the removed column transfers through an alternate path to adjacent columns to prevent local or general failure or to delay the progressive collapse occurrence.

Anaerobic Treatment of Nitrate in Landfill Leachate (쓰레기 매립장 침출수 중 질소저감방안)

  • Kwon, Young Ho;Kim, Ho Ju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.4
    • /
    • pp.70-77
    • /
    • 1998
  • On this study, removal ability of nitrate was researched in the anaerobic zone arounding collection pipes in landfill. Stability state time of column was after 20 days and 20~90ml/day in flux. In this time, removal rate of phosphate was about 80%. Removal ability and average removal rate of CODCr is $36g/m^3{\cdot}d$, 25.3%, respectively. It was that reactor is able to remove more nitrate. Maximum nitrate removal ability was $4.83g/m^3{\cdot}d$.

  • PDF

Removal of Malodorous Gases Emitted from a Wastewater Pumping Stations by Biological Methods (생물학적 방법에 의한 하수 중계펌프장의 악취제거)

  • 류희욱
    • Microbiology and Biotechnology Letters
    • /
    • v.32 no.3
    • /
    • pp.265-270
    • /
    • 2004
  • To select a promising technologies for removal of odorous gases emitted from a wastewater pump station, four methods such as activated carbon (A/C) adsorption, chemical absorption (acid and alkali scrubber), and two biofilters (polyurethane (PU) and worm cast) were investigated. The average odor removal efficiencies in the PU biofilter and A/C column was over 98%, but in a worm cast biofilter and chemical absorption were below 60-80%. The removal efficiency of PU biofilter was very stable (about 98-99%) in the range of retention times of 4-36s, and a maximum elimination capacity was $1.6${\times}$10^{ 7}$ $OUm^{-3}$$h^{-1}$ Deodorization costs for an activated carbon adsorption and a biofiltration method were investigated. With increasing odor intensity, the operating cost of the A/C column increased linearly, but the operating cost of the biofilteration increased slightly. The capital cost in a biofilter is about two times higher than that in an A/C column, but the operating cost is very lower than that of in A/C column. In conclusion, the biofiltration was evaluated one of the most promising technologies to control odor in a wastewater pump station.