• 제목/요약/키워드: removal effect

검색결과 3,160건 처리시간 0.027초

ENHANCED COAGULATION: DETERMINATION OF CONTROLLING CRITERIA AND AN EFFECT ON TURBIDITY REMOVAL

  • Kim, Seung-Hyun
    • Environmental Engineering Research
    • /
    • 제10권3호
    • /
    • pp.105-111
    • /
    • 2005
  • The applicability of the USEPA's (United States Environmental Protection Agency) three criteria of enhanced coagulation (criterion 1-TOC level less than 2 mg/l. before chlorination; criterion II-% requirement of TOC removal; criterion III-point of diminishing return) for Korean waters was evaluated in this study. This study also investigated an effect of enhanced coagulation on turbidity removal, and attempted to identify the best coagulant for enhanced coagulation. Three different waters were used in this study: one river water and two lake waters. five different coagulants were used: alum, liquid alum, PACl, ferric chloride with and without water. Results of this study showed that all three criteria were achievable for the tested waters. For these waters, controlling criterion was found to be different depending upon raw water characteristics. When initial Toe level was low(< 4 mg/L), criterion I (< 2 mg/L) could be the controlling criterion. As TOC level increased, criterion II (% TOC removal) became the controlling criteria. It was possible to achieve different goals of turbidity and TOC removals. Although the optimum region of TOC removal was more acidic than that of turbidity removal, there was no conflict between these two removals. The best coagulant was found to be different depending upon the evaluation tool: maximum and optimum removal. ferric chloride was more effective than alum in terms of the maximum TOC removal, while Al-based coagulant such as alum or PACl was the best coagulant in terms of the optimum TOC removal.

금속파티클-$Al_2O_3$ hybrid 반응기의 NOx 제거에 미치는 유전체 영향 (Effect of dielectrics on NOx removal of Metal particle-$Al_2O_3$ hybrid type reactor)

  • 김종석;박재윤;정장근;김태용;고희석;김형만
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.917-921
    • /
    • 2002
  • In this paper, we made different types of non-thermal plasma reactors such as Metal-particle reactor with $Al_2O_3$ to measure NOx removal characteristic and the dielectric effect for NOx removal. NOx removal rate is not so good when we use just dielectric of $Al_2O_3$ at the Metal-particle reactor, also we just put sludge pellets(100%) without Metal-particle reactor with $Al_2O_3$ and dielectric such as $TiO_2$, $BaTiO_3$ to measure the effect of sludge for NOx removal so that NOx removal rate is almost the same. However NOx removal rate is more than 90% in case of the reactor of composition shape used both dielectric of $Al_2O_3$ and sludge pellets at the same time. In case of the shape of plasma reactor with dielectric, the Metal-particle reactor with $Al_2O_3$, and the metal-particle reactor with both $Al_2O_3$ and dielectric such as $TiO_2$, $BaTiO_3$ at the same time, they are almost the same effect for NOx removal, so we made MNPR(Metal-particle Non-thermal Plasma Reactor with $Al_2O_3$) to reduce these kinds of demerits. Finally, we think MNPR should be much better than other reactors for NOx removal.

  • PDF

하수의 질소제거시 컴퓨터 시뮬레이션을 이용한 UCT(University of Cape Town) 공정의 운영인자 검토 (Investigation of Operating Parameters on UCT Process for the Purpose of Nitrogen Removal Using Computer Simulation)

  • 김병군;서인석;이해군;김창원
    • 환경위생공학
    • /
    • 제13권2호
    • /
    • pp.66-75
    • /
    • 1998
  • The computer simulation model was used to forecast the concentrations of COD$_{cr}$, NH$_{4}$$^{+}$-N and NO$_{3}$$^{-}$-N in each reactors. In the biological wastewater treatment system, the computer simulation model was used to observe the behavior of pollutants especially. In this research, effect of SRT, feeding pattern and recirculation rate on UCT(University of Cape Town) process was evaluated by computer simulation model. T-N removal was affected to the SRT. SRT for effective T-N removal was 15 days or longer. Feeding pattern in UCT process was affected to the T-N removal. Feeding pattern which 100% loading to the first reactor was most effective for T-N removal. The effect of recirculation rate was clear for T-N removal. The recirculation from anoxic reactor to anaerobic reactor was not need but the recirculation from oxic reactor to anoxic reactor was need. In aspect of nitrogen removal efficiency, A/O process was higher than UCT process.

  • PDF

SBR공정에서 영양염류 제거에 대한 염분의 영향 (The Effect of Salinity on Biological Nutrient Removal in SBR)

  • 송창수;오준성
    • 한국물환경학회지
    • /
    • 제18권3호
    • /
    • pp.237-243
    • /
    • 2002
  • The effect of a salinity on the performance of a biological nutrient removal system was investigated using a model SBR(Sequencing Bach Reactor) system. The system was operated at a 12hr, 18hr, 24hr, and 36hr HRT with a salinity level of 20,000mg/L and compared with a system similarly operated with fresh water. The influent salinity level of 8,000 mg/L does not have a significant effect on BOD removal efficiency, there is a noticeable decrease in BOD removal rate from 10,000 mg Cl-/L. The Nitrogen could be removed from the saline wastewater with the same efficiency as for the fresh water because of low C/N ratio in anoxic period. The excess biological phosphorous removal is highly affected by the increase in the influent salinity. The efficiency is decreased from 96.6% to 43.4% when the influent salinity is increased from 0 to 20,000mg/L.

견인력과 접촉표면 제거가 접촉피로수명에 미치는 영향 (Effect of Metal Removal and Traction Force on Contact Fatigue Life)

  • 서정원;허현무;최재붕;김영진
    • 대한기계학회논문집A
    • /
    • 제29권10호
    • /
    • pp.1384-1391
    • /
    • 2005
  • Damage often occurs on the surface of railway wheels due to wheel-rail contact fatigue. It should be removed before reaching wheel failure, because wheel failure can cause derailment with loss of life and property. The increase or decrease of the contact fatigue lift by the metal removal of the contact surface were investigated by many researchers, but they have not considered initial residual stress and traction force. The railway wheel has the initial residual stress formed during the manufacturing process, and the residual stress is changed by thermal stress induced by braking. The traction force and residual stress are operated on wheels of locomotive and electric motor vehicle. In this study, the effect of metal removal depth on the contact fatigue life for a railway wheel has been evaluated by applying lolling contact fatigue test. The effect of the traction force and metal removal on the contact fatigue life has been estimated by finite element analysis. It has been found that the initial residual stress determines the amount of metal removal depth if the traction coefficient is less than 0.15. If the traction coefficient is greater than 0.2, however, the amount of metal removal depth is independent on the intial residual stress.

슬러지 탄소원을 주입한 UNR공정의 동절기 질소, 인 처리효율 (The Nitrogen and Phosphorus Removal of UNR Process Using Sludge Carbon Source)

  • 김영규;김인배
    • 한국환경보건학회지
    • /
    • 제28권1호
    • /
    • pp.93-97
    • /
    • 2002
  • The aim of this study was to evaluate on the removal effect of total nitrogen and phosphorus with municipal wastewater in ultrasonic nutrient removal (UNR) process using ultrasonic sludge carbon source. The removal efficiency for total nitrogen was 44.2% at biological nutrient removal (BNR) process, 50.8% at UNR process. The removal efficiency for total phosphorus was 45.6% at BNR process, 46.2% at UNR process. The removal of nitrogen was effectively influenced by ultrasonic sludge carbon source.

정수처리공정에 따른 일반세균과 대장균군의 제거에 관한 연구 (A Study on the Removal Effect of Bacteria and E. Coli. by Water Treatment Processes using Activated Carbon and Membrane)

  • 조태석;김영규;정문호
    • 한국환경보건학회지
    • /
    • 제23권2호
    • /
    • pp.24-27
    • /
    • 1997
  • This study has been designed to check the removal effect of contaminated water by various water treatmemt processes using sediment filter, activated carbon, reverse osmosis membrane, ultra vilolet sterilizer and ultra filtration and then to analyze the change of pH, the concentration of chlorides, bacteria and E. coli. after 24 hours. pH has increased as much as 0.15-0.32 by activated carbon but decreased sharply by reverse osmosis treatment after 24 hours. The removal effect of chloride was low by activated carbon and ultra filter but high in reverse osmosis. The removal effect of bacteria and E. coli was low by activated carbon and membrane filter system using activated carbon. Ultra filtration process was effective for purify agricultural water containg bacteria and E.coli.

  • PDF

천연 점토를 이용한 Pb(II)의 흡착에 관한연구

  • 김강우;이한섭
    • 한국환경보건학회지
    • /
    • 제27권2호
    • /
    • pp.138-144
    • /
    • 2001
  • This study was carried out to investigate characteristics and Pb(II) removal effect of natural clays in the batch mode test. The effect of parameters such as temperature, adsorption time and coexisting cations on the sorption ability and characteristics was investigated to find out whether the clays could be used as adsorbents. Several natural clays from domestic have been investigated to have high specific surface area and have minerals such as SiO$_2$ and $Al_2$O$_3$. As a result, removal effects of Pb(II) on clays were reached at equilibrium in aqueous solutions by stirring about 20 minutes. The removal effect of Pb(II) was best for Kang Jin clay than other clays in terms of fixed time. Adsorption efficiency was not influenced by the possibility of continuous treatment system of wastewater which contain heavy metals by using natural clays from domestic.

  • PDF

In Vitro Study on the Artificial Plaque Removal Effect by Use of 360 Degree Rotating Head with Sonic Tooth-Brush

  • Lim, Jee-Hyun;Kim, Jin-Sil;Choi, Hwa-Young
    • International Journal of Clinical Preventive Dentistry
    • /
    • 제14권4호
    • /
    • pp.228-234
    • /
    • 2018
  • Objective: The authors have experimented for the artificial plaque removal effect of several kinds of 360 degree rotating head typed tooth-brushes with sonic vibratory actioned by using of automatic machine for horizontal scrub method in order to find the better toothbrush type for plaque removal. Methods: The experiment was conducted on three medium to 360 degree rotating head toothbrushes, a medium sized toothbrush and a medium sized toothbrush, and a flat toothbrush consisting of 30 ordinary toothbrushes. A brushing machine with horizontal scrubbing was manufactured and had variations of the end of the bristle attached to or near the surface of the teeth, a vibrating wave action force of 16,000 or 18,000 cycles per minute, and a working time of 2 or 3 minutes. The tooth removal effect was confirmed by scanning and analyzing images with a computer program after automatic brushing with the machine. The elimination rate results for each group were analyzed using the independent t-test and one-way ANOVA test. Results: It revealed the most in removal effect for the artificial plaque in such conditions as action at near the tooth surface with 18,000 cycle for 3 minutes in case of using A, B, and C tooth-brush. And it has more removal effect rate than for using the plane tooth-brush (p<0.05). Conclusion: It was recommended to develop the 360 degree rotating head and vibratory toothbrush focusing to use near the tooth surface with 18,000 cycles of vibration for 3 minutes at one site of the teeth area.

Analysis of Dental Plaque Removal Effect by Floss Type Using QLF-D

  • Myoung-Hee Kim;Yu Jin Park;Young Sun Hwang
    • 치위생과학회지
    • /
    • 제22권4호
    • /
    • pp.199-205
    • /
    • 2022
  • Background: The use of dental floss is associated with a reduction in dental caries and periodontal disease. According to personal preference, not only thread type but also C type and Y type floss are used. Although the effectiveness of dental floss for removing dental plaque has been proven, plaque removal effect of C type and Y type floss has not been well reported. In this study, the plaque removal effect of C type and Y type floss compared to thread type floss was experimentally verified. Methods: Thread type, C type and Y type floss were used to remove dental plaque. Ten people in each flossing group participated, and by applying dental floss to the 6 incisors of the maxilla and mandible, the degree of dental plaque was analyzed by QLF-D. To evaluate the removal degree of dental plaque before and after flossing, Simple Plaque Score (SPS), Area R30, Area R70, and Area R120 score were measured. Results: In the analysis using the Area R30 fluorescence score of the QLF-D system, the degree of plaque removal according to the application of dental floss was effective in all the thread type (p=0.018), C-type (p=0.012), and Y-type (p=0.012) floss groups compared to before the application of the floss. Among them, C type floss was more effective in removing plaque than thread type and Y type floss. However, the plaque removal effect between the three floss types was not significantly different in ∆SPS (p=0.674), ∆Area R30 (p=0.726), ∆Area R70 (p=0.504), and ∆Area R120 scores (p=0.423). Conclusion: Thread type, C type, and Y type floss were all effective in removing dental plaque, but there was no significant difference in dental plaque removal effect according to the type of floss.