• Title/Summary/Keyword: remote diagnostic system

Search Result 58, Processing Time 0.037 seconds

Development of ZigBee Wireless Communication System for Remote Diagnosis in Distribution Power Lines (배전선로 원격 진단을 위한 ZigBee 무선통신 시스템 개발)

  • Lee, Kyeong-Seob;Chung, Dong-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.9
    • /
    • pp.602-606
    • /
    • 2015
  • This paper presents a ZigBee wireless communication system for remote diagnosis in overhead distribution power lines. The system is divided in three parts in the functional aspect - a host computer module, a remote controller module and a diagnostic system module. The host computer module designed as USB interface transmits control signals and receive data measured by sensor. The remote controller module operates the diagnostic system. Diagnostic system module communicates with internal main controller and host computer USB. Multiple communication channel is adopted for simultaneous operations of several diagnostic system. Dedicated protocol for each module is developed. The system is designed with a focus on low cost and small size suitable for lightweight and small diagnostic system.

Development of a Diagnostic System for Motor-Operated Valves (모터구동밸브 진단장비 개발)

  • Kang, Seong-Ki;Choi, Hyun-Woo;Park, Sung-Keun;Kang, Shin-Chul;Chai, Jang-Bom
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.420-424
    • /
    • 2008
  • The new MOV(motor-operated valve) diagnostic system MOVIDS(MOV intelligent diagnostic system) was developed. Its remote diagnostic methods with high accuracy have improved the applicability. This enables the diagnostic tests and the evaluations of many MOVs not only at the valves but also in remote places like MCCs(motor control centers). The remote diagnostic ability of the new system reduces the cost and the man power for diagnosing MOVs and eliminates the danger of the toxic or radioactive environments to which workers might be exposed.

  • PDF

Remote Patient Monitoring System for Diagnostic Pure-tone Audiometry (순음 청력검사를 위한 원격진단 모니터링 시스템)

  • Lee, Kang-Ho;Kwon, Yeong-Eun;Kwon, Ohwon
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.289-293
    • /
    • 2019
  • This paper presents a remote patient monitoring system for diagnostic pure-tone audiometry. A pure-tone audiometer was developed for basic hearing screening; its performance was evaluated according to international standards in terms of linearity, accuracy, and total harmonic distortion. Pure-tone audiometry has a maximum hearing level of 104.9 dB HL that is comparable with other commercial products. The audiometer shows satisfactory linearity with a deviation of ${\pm}0.4dB$, an accuracy of ${\pm}0.025%$, and a total harmonic distortion (THD) of 0.21%. The remote patient monitoring systems include remote control devices based on wide area network (WAN) connections and an audiometer connected in series. Through experimentation, we successfully performed real-time diagnostic communication without delay in transferring audiometric data. This system is expected to supply domestic equipment in the audiometric market and to improve the quality of life of patients in non-clinical environments.

A Study on Remote ECG Diagnostic System Using Telephone Line (공중회선망을 이용한 원격 심전도 진단 시스템)

  • Lee, M.H.;Park, S.H.;Kim, Y.M.;Shin, K.S.;Jeong, H.K.;Jeong, K.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.69-78
    • /
    • 1992
  • This Paper describes implementation of a remote ECG diagnostic system using telephone line. The overall system includes ECG data acquisition system, ECG terminal, system control software, automatic diagnosis system, and transmission system.'The proposed system provides various functions, which are ECG data acquisition, transmission, receiving, diagnosis and dialogue between patients and medical doctors. Thls system is very simple and convienient to use. We evaluate the performance of modem and the accuracy of automatic diagnosis algorithm. The obtained results suggest the Possibilities of a remote ECG diagnostic system using the only existed telephone line.

  • PDF

Development of Automatic Data Acquisition & Remote Diagnostic System for Improving Efficiency of High-Voltage Motors Off-Line Insulation Diagnostic Test (고압전동기 Off-Line 절연진단시험 효율개선을 위한 데이터자동취득 및 원격진단시스템 구축)

  • Kang, Sang-Mu;Kang, Dae-Jeong;Han, Hyun-Seok;Kim, Won-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.707-708
    • /
    • 2015
  • This paper proposes a method for improving efficiency of high-voltage motors off-line insulation diagnostic test. The conventional manual test method has measurement errors and excessive processing time. We developed the KITAS system and solved these problems by using the instrument remote control and communication technology. The result of proficiency testing by interlaboratory comparisons using Power Factor Tip-Up test was '${\mid}E_n{\mid}$ < 1'. It was possible to confirm the validity of acquired data from the KITAS and establish a remote diagnostic system for easy access without physical limitations.

  • PDF

Self-Diagnostic Signal Monitoring System of KWP2000 Vehicle ECU using Bluetooth

  • Choi, Kwang-Hun;Lee, Hyun-Ho;Lee, Young-Choon;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.132-137
    • /
    • 2004
  • On-Board Diagnostic(OBD) systems are in most cars and light trucks on the load today. During the 1970's and early 1980's manufacturers started using electronic means to control engine functions and diagnose engine problems. The CARB's diagnostic requirements to meet EPA emission standards have been designated as OBD with a goal of monitoring all of the emissions-related components, as well as the chassis, body, accessory devices and the diagnostic control network of the vehicle for proper operation. In this paper, we present a remote measurement system for the wireless monitoring of diagnosis signal and sensors output signals of ECU adopted KWP2000, united the OBD communication protocol, on OBD-compliant vehicle using the wirless communication technique of Bluetooth. In order to measure the ECU signals, the interface circuit is designed to communicate ECU and designed terminal wirelessly according to the ISO, SAE regulation of communication protocol standard. A microprocessor S3C3410X is used for communicating ECU signals. The embedded system's software is programmed to measure the ECU signals using the ARM compiler and ANCI C based on MicroC/OS kernel to communicate between bluetooth modules using bluetooth stack. The diagnostic system is developed using Visual C++ MFC and protocol stack of bluetooth for Windows environment. The self-diagnosis and sensor output signals of ECU is able to monitor using PC with bluetooth board connected in serial port of PC. The algorithms for measuring the ECU sensor output and self-diagnostic signals are verified to monitor ECU state. At the same time, the information to fix the vehicle's problem can be shown on the developed monitoring software. The possibility for remote measurement of self-diagnosis and sensor signals of ECU adopted KWP2000 in embedded system verified through the developed systems and algorithms.

  • PDF

Remote Measuring System for Automobile′s ECU Self Diagnostic Signal (자동차 ECU 자기진단 신호의 원격계측 시스템)

  • Jeong, Jin-Ho;Yun, Yeo-Heung;Lee, Young-Choon;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.5
    • /
    • pp.159-167
    • /
    • 2002
  • In this paper. we present a new method for monitoring of ECU's self diagnostic signals of vehicle without wire. In order to measure the ECU's self diagnostic signals, the interfaced circuit is designed to communicate ECU and designed terminal according to the IOS, SAE regulation of communication protocol standard. Micro-processor 80C196KC is used for communicating ECU's self diagnositc signals and the results are sent to the wireless terminal and PC monitoring system. Wireless terminal is also developed by 80C196KC, LCD, RF module, and keypad. The command from the keypad is sent to ECU through RF module and the result show on the Graphic LCD in real time. Software on PC is developed to monitor the ECU's self diagnostic signals using the Visual C++ complier in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self diagnostic signals are verified to monitor both ECU and portable terminal state. At the same time, the information to fix the vehicle's problem can be shown on the developed software. The possibility for remote measurement of ECU self diagnostic signal is verified through the developed systems and algorithms.

Development of electro hydraulic ballast remote valve control system with diagnostic function using redundant modbus communication (이중화 모드버스 통신을 이용한 퍼지기반 고장진단기능을 가진 선박 밸러스트 전기유압식 원격밸브제어시스템 개발)

  • Kim, Jong Hyun;Yu, Yung Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.292-301
    • /
    • 2014
  • This paper describes development of distributed type independent electro-hydraulic ballast valve remote control system with diagnostic function based on fuzzy inference using redundant Modbus communication and ethernet Modbus TCP/IP. Diagnostic function estimate degradation of system components and diagnose system faults, which results in shortage of fault maintenance time and improvement of system safety. Slave devices which control each valve and master device which command, monitor and diagnose slave system are developed. Slave devices are connected to master device with redundant Modbus networks and master device is connected to ship's integrated control system with Modbus TCP/IP. Also this paper describes development of simulator to test and confirm whether developed system can be integrated with ship's integrated control and monitoring system.

Remote Fault Diagnosis and Maintenance System for NC Machine Tools (공작기계용 원격 고장진단 및 보수 시스템)

  • 신동수;현웅근;정성종
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.1
    • /
    • pp.19-25
    • /
    • 1998
  • Remote fault diagnosis and maintenance system using general telecommunication network is necessary for an effective fault diagnosis and higher productivity of NC machine tools. In order to monitor machine tool condition and diagnose alarm states due to electrical and mechanical faults, a remote data communication system for monitoring of NC machine fault diagnosis and status is developed. The developed system consists of (1) remote communication module among NC's and host PC using PSTN. (2) 8 channels analog data sensing module, (3) digital I/O module for control or NC machine, (4) communication module between NC machine and remote data communication system via RS-232C, and (5) software man-machine interface. Diagnostic monitoring results generated through a successive type inference engine are displayed in user-friendly graphics. The validity and reliability of the developed system is verified to be a powerful commercial version on a vertical machining center through a series of experiments.

  • PDF

Remote Measurement for Automobile′s ECU Diagnostic Signals based on the PDA (PDA 기반의 차량 진단신호의 원격 계측)

  • 윤여흥;서지원;이현호;권대규;이영춘
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.279-282
    • /
    • 2002
  • In this paper, we present a new method for monitoring of ECU's self diagnostic signals of vehicle without wire. In order to measure the ECU's self diagnostic signals, the interfaced circuit is designed to communicate ECU and a designed display terminal according to the ISO, SAE regulation of communication protocol standard. A 80C196KC processor is used for communicating ECU's self diagnostic signals and the results are sent to PDA monitoring system. Software on PDA is developed to monitor the ECU's self diagnostic signals using the Embedded Visual C++ compiler in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self diagnostic signals are verified to monitor ECU's state. At the same time, the information to fix the vehicle's problem can be shown on the developed PDA software. The possibility for remote measurement of ECU self diagnostic signal using PDA is also verified through the developed systems and algorithms.

  • PDF