• Title/Summary/Keyword: reliable data set

Search Result 256, Processing Time 0.027 seconds

Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy (토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교)

  • Lee, Byungkoo;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.

Quantitative Analysis of Vitamin B5 and B6 Using High Performance Liquid Chromatography (고속액체크로마토그래피를 이용한 비타민 B5 및 B6의 정량 분석)

  • Kim, Gi-Ppeum;Hwang, Young-Sun;Choung, Myoung-Gun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.10
    • /
    • pp.1186-1194
    • /
    • 2017
  • Recently, many people have demanded reliable nutritional data even for minor-components. On the other hand, an analytical method for the analyses of vitamin $B_5$ and $B_6$ is lacking. Therefore, this study attempted to validate with accuracy and precision the analysis of vitamin $B_5$ and $B_6$ using a high-performance liquid chromatography (HPLC) method. The vitamin $B_5$ and $B_6$ contents were analyzed using an Agilent 1260 series HPLC system. YMC-Pack ODS-AM ($250{\times}4.6mm$ I.D.) and YMC-Pack Pro RS $C_{18}$ ($250{\times}4.6mm$ I.D.) columns were used for the analyses of vitamin $B_5$ and $B_6$, respectively. In the case of vitamin $B_5$, the flow rate was set to 1.0 mL/min by isocratic elution using the 50 mM $KH_2PO_4$ solution (pH 3.5)/acetonitrile (ACN) (95:5, v/v) with monitoring at 200 nm using HPLC/DAD, whereas the flow rate for vitamin $B_6$ was set to 1.0 mL/min of flow rate by isocratic elution using a 20 mM $CH_3CO_2Na$ solution (pH 3.6)/ACN (97:3, v/v) with monitoring by excitation at 290 nm and emission at 396 nm using HPLC/FLD. The column temperature was set to $30^{\circ}C$. The injection volume was $20{\mu}L$ for each experiment. The specificity of the accuracy and precision for vitamin $B_5$ and $B_6$ were also validated by HPLC. The results showed high linearity in the calibration curve for vitamin $B_5$ ($R^2=0.9998^{{\ast}{\ast}}$), the limit of detection (LOD) and limit of quantitation (LOQ) were 0.4 mg/L and 1.3 mg/L, respectively, In contrast, for the calibration curve of vitamin $B_6$, which showed high linearity ($R^2=0.9999^{{\ast}{\ast}}$), the LOD and LOQ were 0.006 mg/L and 0.02 mg/L, respectively.

Provisional National Nutrition Targets and Strategies for Health Promotion of Koreans (국민건강증진을 위한 영양 부문의 2000년 잠정목표와 전략)

  • 김혜련
    • Korean Journal of Community Nutrition
    • /
    • v.1 no.2
    • /
    • pp.161-177
    • /
    • 1996
  • This study attempts to propose a priority of national nutrition targets and strategies for health promotion by the year 2000 in Korea, as a part of the task set for national health promotion objectives and strategies. Among all of the important health issues raised, ten were chosen, nutrition was one priority area. In the first part, the current status of the nutrition-related health problems and risk factors are reviewed, in conjunction with the newly arisen health phenomena, such as changes in prevalence of lifestyle disease and causes of death, changes of food consumption patterns in our country. In the second section this study suggests six feasible national nutrition targets, eight implementing strategies and current major tasks on the basis of the assessment of present status and in consideration of the other health promotion goals and strategies, with reference to that of other developed countries. The main targets and strategies are suggested as follows ; Firstly, the national nutrition monitoring and surveillance system should be established for identifying the nutritional problems for our people, and current National Nutrition Survey is a strong need for improvement to a more comprehensive and reliable one. Secondly, effective administrative mechanism should be operation at national level for the development of nutrition policy. Ministry of Health and Welfare (MOHW) as well as local health department must be remarkably renewed and strengthened the nutrition section. And it is recommended that MOHW organize and operate “The Council of Nutrition”, in which all government authorities related with foodstuffs and nutrition would incorporated. The Council of Nutrition would act as an adjustor as well as a coordinator in nutrition related policy-making. Thirdly, healthy eating pattern will be supported by activities of introducing a nutrition labeling for providing consumers with the necessary information and skills for food selection. Fourthly, nutrition education, and nutrition intervention programs will be carried out in various settings such as health centers, schools, and clinical fields and workplace. Fifthly, the current dietary guidelines shall be continuously improved in detail, and publicly circulated to particular levels of people by age group and by health condition. And finally, researches and epidemiological studies particularly in regard to diet for development of chronic diseases are needed for more investigation and up-to-date national health and nutrition data should be collected with the support and cooperation from the various medical professional teams . (Korean J Community Nutrition 1(2) : 161-177, 1996)

  • PDF

The Trends and Prospects of Health Information Standards : Standardization Analysis and Suggestions (의료정보 표준에 관한 연구 : 표준화 분석 및 전망)

  • Kim, Chang-Soo
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • Ubiquitous health care system, which is one of the developing solution technologies of IT, BT and NT, could give us new medical environments in future. Implementing health information systems can be complex, expensive and frustrating. Healthcare professionals seeking to acquire or upgrade systems do not have a convenient, reliable way of specifying a level of adherence to communication standards sufficient to achieve truly efficient interoperability. Great progress has been made in establishing such standards-DICOM, IHE and HL7, notably, are now highly advanced. IHE has defined a common framework to deliver the basic interoperability needed for local and regional health information networks. It has developed a foundational set of standards-based integration profiles for information exchange with three interrelated efforts. HL7 is one of several ANSI-accredited Standards Developing Organizations operating in the healthcare arena. Most SDOs produce standards (protocols) for a particular healthcare domain such as pharmacy, medical devices, imaging or insurance transactions. HL7's domain is clinical and administrative data. HL7 is an international community of healthcare subject matter experts and information scientists collaborating to create standards for the exchange, management and integration of electronic healthcare information. The ASTM specification for Continuity of Care Record was developed by subcommittee E31.28 on electronic health records, which includes clinicians, provider institutions, administrators, patient advocates, vendors, and health industry. In this paper, there are suggestions that provide a test bed, demonstration and specification of how standards such a IHE, HL7, ASTM can be used to provide an integrated environment.

  • PDF

Image Analysis Using Digital Radiographic Lumbar Spine of Patients with Osteoporosis (골다공증 환자의 Digital 방사선 요추 Image를 이용한 영상분석)

  • Park, Hyong-Hu;Lee, Jin-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.362-369
    • /
    • 2014
  • This study aimed to propose an accurate diagnostic method for osteoporosis by realizing a computer-aided diagnosis system with the application of the statistical analysis of texture features using digital images of lateral lumbar spine of patients with osteoporosis and providing reliable supplementary diagnostic information by model experimental research for early diagnosis of diseases. For these purposes, digital images of lateral lumbar spine of normal individuals and patients with osteoporosis were used in the experiments, and the values of statistical texture features on the set ROI were expressed in six parameters. Among the texture feature values of the six parameters of osteoporosis, the highest and lowest recognition rates of 95 and 80% were shown in average gray level and uniformity, respectively. Moreover, all the six parameters showed recognition rates of over 80% for osteoporosis: 82.5% in average contrast, 90% in smoothness, 87.5% in skewness, and 87.5% in entropy. Therefore, if a program developing into a computer-aided diagnosis system for medical images is coded based on the results of this study, it is considered possible to be applied to preliminary diagnostic data for automatic detection of lesions and disease diagnosis using medical images, to provide information for definite diagnosis of diseases, to diagnose by limited device, and to be used to shorten the time to analyze medical images.

A study on the method for the Integrated Cost Estimate based on Project(ICEP) of program management with typical model (기준모델을 사용한 종합사업관리용역비 산정방법(ICEP) 연구)

  • Baek, Myeongchang;Park, Junmo;Park, Gilbeom;Kim, Okkyue
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.1
    • /
    • pp.119-128
    • /
    • 2015
  • Domestic dominant method in subcontract cost estimate for comprehensive program management is estimation by referencing similar cases or relying on the experience and expertise of the engaged. However, this method is not reliable due to lack of accuracy, making it harder for clients to plan and budget the program. Since budget itself is roughly estimated, it becomes a source of cost rise in the course of management due to design modifications. Therefore, the client and service providers shall calculate more accurate service cost by applying objective and scientific method in order to minimize cost rise and cost related dispute. Traditional cases, in estimating program management cost, took Top-Down approach based on precedents and experience. On the contrary, this study will categorize management structure into phases and activities, issue WBS for each phase to estimated schedule and cost for each code, and take Bottom-UP approach. By taking this approach named ICEP (Integrated Cost Estimate based on Project), Set project typical model will be developed for service cost estimating, calculate cost by applying project-specific factors. Also, by analyzing progress data and allocated management cost to complement them, more efficient construction management will take shape based on program management cost standards which reflect project-specific features.

Verification of X-sight Lung Tracking System in the CyberKnife (사이버나이프에서 폐종양 추적 시스템의 정확도 분석)

  • Huh, Hyun-Do;Choi, Sang-Hyoun;Kim, Woo-Chul;Kim, Hun-Jeong;Kim, Seong-Hoon;Cho, Sam-Ju;Min, Chul-Ki;Cho, Kwang-Hwan;Lee, Sang-Hoon;Choi, Jin-Ho;Lim, Sang-Wook;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.174-179
    • /
    • 2009
  • To track moving tumor in real time, CyberKnife system imports a technique of the synchrony respiratory tracking system. The fiducial marker which are detectable in X-ray images were demand in CyberKnife Robotic radiosurgery system. It issued as reference markers to locate and track tumor location during patient alignment and treatment delivery. Fiducial marker implantation is an invasive surgical operation that carries a relatively high risk of pneumothorax. Most recently, it was developed a direct lung tumor registration method that does not require the use of fiducials. The purpose of this study is to measure the accuracy of target applying X-sight lung tracking using the Gafchromic film in dynamic moving thorax phantom. The X-sight Lung Tracking quality assurance motion phantom simulates simple respiratory motion of a lung tumor and provides Gafchromic dosimetry film-based test capability at locations inside the phantom corresponding to a typical lung tumor. The total average error for the X-sight Lung Tracking System with a moving target was $0.85{\pm}0.22$ mm. The results were considered reliable and applicable for lung tumor treatment in CyberKnife radiosurgery system. Clinically, breathing patterns of patients may vary during radiation therapy. Therefore, additional studies with a set real patient data are necessary to evaluate the target accuracy for the X-sight Lung Tracking system.

  • PDF

A Study on Theoretical Consideration to the Holding Power and Holding Power Coefficient of War Ship Anchor (함정 묘의 파주력과 파주계수에 대한 이론적 고찰에 관한 연구)

  • Lim, Bong-Taek;Ko, Jae-Woo;Kim, Byoung-Suk
    • Journal of Navigation and Port Research
    • /
    • v.39 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • In this study, with the awareness of the limitations set in the currently operated calculations of holding power and the holding power coefficient of anchors of naval ships due to its simple application of a specific value, various factors that impact the holding power and its coefficient were verified based on existing data analysis of literature research and numerous experiment results from anchor manufacturers, research institutes and academic community in order to overcome the aforementioned limitations. In addition, holding power and holding power coefficient were compared and analyzed by the shape of anchors. As a result, we came to know that the holding power of AC-14 type anchor is stronger than that of ASS type anchor or U.S. Navy Standard type anchor which makes it possible to reduce the weight of the anchor and therefore ease the process of naval shipbuilding. Furthermore, we confirmed the fact that U.S. Navy Standard type anchor does not react sensitively to the weight change of the anchor. Lastly, we found out that Danforth type anchor's holding power coefficient is in inverse proportion to the weight. Moreover, instructions for managing anchor are arranged easily for your information. The results of this study is expected to provide anchor - operating naval crew with a reliable theoretical basis pertaining to an anchor's holding power and its coefficient and contribute much for the safety of their act of anchoring.

Human Motion Tracking by Combining View-based and Model-based Methods for Monocular Video Sequences (하나의 비디오 입력을 위한 모습 기반법과 모델 사용법을 혼용한 사람 동작 추적법)

  • Park, Ji-Hun;Park, Sang-Ho;Aggarwal, J.K.
    • The KIPS Transactions:PartB
    • /
    • v.10B no.6
    • /
    • pp.657-664
    • /
    • 2003
  • Reliable tracking of moving humans is essential to motion estimation, video surveillance and human-computer interface. This paper presents a new approach to human motion tracking that combines appearance-based and model-based techniques. Monocular color video is processed at both pixel level and object level. At the pixel level, a Gaussian mixture model is used to train and classily individual pixel colors. At the object level, a 3D human body model projected on a 2D image plane is used to fit the image data. Our method does not use inverse kinematics due to the singularity problem. While many others use stochastic sampling for model-based motion tracking, our method is purely dependent on nonlinear programming. We convert the human motion tracking problem into a nonlinear programming problem. A cost function for parameter optimization is used to estimate the degree of the overlapping between the foreground input image silhouette and a projected 3D model body silhouette. The overlapping is computed using computational geometry by converting a set of pixels from the image domain to a polygon in the real projection plane domain. Our method is used to recognize various human motions. Motion tracking results from video sequences are very encouraging.

Construction of DNA Profile Data Base of Strawberry Cultivars Using Microsatellite Markers (Microsatellite 마커를 이용한 딸기 품종의 DNA Profile Database 구축)

  • Hong, Jee-Hwa;Choi, Keun-Jin;Kwon, Yong-Sham
    • Horticultural Science & Technology
    • /
    • v.32 no.6
    • /
    • pp.853-863
    • /
    • 2014
  • This study was carried out to construct a DNA profile database of 100 strawberry cultivars using microsatellite markers. Two hundred seventy four microsatellite primer pairs were screened with a set of 21 strawberry cultivars with different morphological traits. Twenty five primer pairs were selected because they produced reliable and reproducible fingerprints. These primer pairs were used to develop DNA profiles of 100 strawberry cultivars. Three to thirteen alleles were detected by each marker with an average of 7.50. The average polymorphism information content varied from 0.331 to 841 (average 0.706). Cluster analysis showed that the 100 cultivars were divided into 7 major groups reflecting geographic origin and pedigree information. Moreover, most of the cultivars could be discriminated by marker genotypes. These markers will be useful as a tool for the protection of plant breeders' intellectual property rights in addition to providing the means to intervene seed disputes relating to variety authentication.