• 제목/요약/키워드: relay system

검색결과 1,267건 처리시간 0.031초

연계선로 보호계전기 개발 (Development of Interconnection Protective Relay)

  • 박경원;안홍선;신종한;박장수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.311-313
    • /
    • 2003
  • There have been public attraction and studies about distributed generation systems. But protective relay must be installed between utility system and customer owned distributed generation system has not been developed. So this paper describes the development of a digital protective relay for interconnection. The developed protective relay includes protective elements required by KEPCO at the interconnection point.

  • PDF

Optimized Relay Node Deployment and Resource Allocation in LTE-Advanced Relay Networks

  • Fenghe, Huang;Joe, In-Whee
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2014년도 춘계학술발표대회
    • /
    • pp.146-148
    • /
    • 2014
  • In LTE-Advanced (LTE-A) networks, Relay nodes (RN) are used to improve the system coverage. However, it also brings new kind of interference to users which reduces the system performance. In this paper, we use an optimization relay node deployment to reduce the interference as much as possible and resource allocation to improve the user throughput. Our simulation results show our method is able to improve the user SINR and throughput.

LTE-Advanced 시스템의 다중 사용자 MIMO Relay 네트워크에서 간섭 제거를 위한 Joint Precoding 기술 (Joint Precoding Technique for Interference Cancellation in Multiuser MIMO Relay Networks for LTE-Advanced System)

  • 사란쉬 말리크;문상미;김보라;김철성;황인태
    • 대한전자공학회논문지TC
    • /
    • 제49권6호
    • /
    • pp.15-26
    • /
    • 2012
  • 본 논문에서는 개선된 AF(Amplify-and-Forward)와 DF(Decode-and-Forward) Relay 프로토콜을 결합한 다중 사용자 MIMO (Multiple Input Multiple Output) Relay 네트워크에서 간섭 제거 기술을 논의 한다. 간섭 제거 기술은 Relay 노드가 적용된 전체 전송 시스템의 오류 성능을 향상시키기 위해 eNB(evolved NodeB), Relay 노드(RN: Relay Node)와 UE(User Equipment)에 의해 이루어진다. 간섭 제거를 수행하기 위해 ZF(Zero Forcing), MMSE(Minimum Mean Square Error), SIC(Successive Interference Cancellation)와 OSIC(Ordered Successive Interference Cancellation)가 적용된 DPC(Dirty Paper Coding)와 THP(Thomilson Harashima Precoding)를 사용하였다. 이러한 기본적인 기술이 적용된 Relay 노드 기능들이 연구되고 개선된다. 협력 Relay 노드에서 두 계층 간의 간섭 제거를 강화한 DF는 성능을 향상시킨다. eNB와 RN간의 가중치 벡터를 사용하여 간섭 제거가 수행된다. 연구 최종 결과, 기존의 알고리즘과 비교하여 제안된 알고리즘이 낮은 SNR에서 더 좋은 성능을 나타냈다. 모의실험 결과 LTE-Advanced 시스템에서 제안된 기법이 오류 성능 면에서 상당한 향상을 나타냈다.

분산전원이 도입된 배전계통에 초전도한류기 적용에 따른 과전류계전기 동작향상 연구 (Study on Improvement of Overcurernt Relay (OCR)'s Operation Due to Application of Superconducting Fault Current Limiter (SFCL) in Power Distribution System with a Dispersed Generation)

  • 임승택;임성훈
    • 전기학회논문지
    • /
    • 제66권2호
    • /
    • pp.300-304
    • /
    • 2017
  • Due to the introduction of various types of dispersed generations (DGs) with larger capacity in a power distribution system, the short-circuit current is expected to be increased, which more requires for the effective fault current limiting methods. As one of the promising countermeasures, the superconducting fault current limiter (SFCL) has been noticed. However, the decreased fault current by SFCL affects the operation of the overcurrent relay (OCR), representative protective device in a power distribution system. In this paper, the operation of the overcurrent relay due to the application of a SFCL in a power distribution system with DG linked by its bus line was analysed through the short-circuit tests. To analyze the effect of the SFCL application in a power distribution system with DG, the experimental simulated circuits were designed and the short-circuit tests for the power distributed system assembled with the DG, the OCR and the SFCL were carried out. Through the analysis on the short-circuit tests, the application of the SFCL in a power distribution system with DG could be confirmed to be contributed to the operational improvement of overcurrent relay.

Development of Protection Method for Power System interconnected with Distributed Generation using Distance Relay

  • Kim, Ji-Soo;Cho, Gyu-Jung;Song, Jin-Sol;Shin, Jae-Yun;Kim, Dong-Hyun;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2196-2202
    • /
    • 2018
  • The conventional power system allowed only downstream power flow. Therefore, even if a fault occurs, only the forward current flow is considered. However, with the interest in distributed generation (DG), DGs such as Photovoltaic (PV), Wind Turbine (WT) are being connected to a power system. DGs have many advantages, but they also have disadvantage such as generation of reverse flow. Reverse flow can severely disrupt existing protection systems that only consider downstream power flow. The major problems that may arise from reverse power flow are blinding protection and sympathetic tripping. In order to solve such problems, the methods of installing a directional relay or a fault current limiter is proposed. However, this method is inconceivable because of the economics shortage. Therefore, in this paper, a distance relay installed in existing power system is used to solve the protection problem. Modeling of distance relay has been carried out using ElectroMagnetic Transients Program (EMTP), and it has been verified through simulations that the above problems can be solved by a distance relay.

비접지 DC 급전계통에서 전류형 지락보호계전 방법 (Ground fault protective relaying schemes for DC traction power supply system)

  • 정상기;정락교;이성혁;김연수;조홍식
    • 한국철도학회논문집
    • /
    • 제7권4호
    • /
    • pp.412-417
    • /
    • 2004
  • In urban rail transit systems, ground faults in the DC traction power supply system are currently detected by the potential relay, 64P. Though it detects the fault it cannot identify the faulted region and therefore the faulted region could not be isolated properly. Therefore it could cause a power loss of the trains running on the healthy regions and the safety of the passengers in the trains could be affected adversely. Two new ground fault protective relay schemes that can identify the faulted region are presented in this paper. A current limiting device, called Device X, is newly introduced in both system, which enables large amount of ground fault current flow upon the positive line to ground fault. One type of the relaying schemes is called directional and differential ground fault protective relay which uses the current differential scheme in detecting the fault and uses the permissive signal from neighboring substation to identify the faulted region correctly. The other is called ground over current protective relay. It is similar to the ordinary over current relay but it measures the ground current at the device X not at the power feeding line, and it compares the current variation value to the ground current in Device X to identify the correct faulted line. Though both type of the relays have pros and cons and can identify the faulted region correctly, the ground over current protective relaying scheme has more advantages than the other.

다양한 릴레이 조건에 따른 협력 통신 기법의 성능 분석 (Performance analysis of cooperative communication algorithm with various relay conditions)

  • 김윤현;박재성;김진영
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.329-332
    • /
    • 2009
  • In this paper, performance of cooperative communication system is analyzed with various relay conditions for mobile communication system using OFDM. We research mainly on the performance analysis of amplify-and-forward scheme. First, we analyzed the diversity gain between the number of antenna on the relay is one and two. And then, in this paper, we analyzed difference of the performance with distance between relay and mobile. Amplify-and-forward scheme has the problem that the noise components are also amplified in low sinal-to-noise (SNR) condition. The results of this paper can be applicable to the cooperative relay systems.

  • PDF

송전선 보호용 차동전류 계전기의 동작원리에 대한 그래픽 표현 (Graphical Modeling for Operational Scheme of Current Differential Relay for Transmission Line Protection)

  • 이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1407-1409
    • /
    • 1999
  • Distance relay is being used for transmission line protection. Recently, current differential relay is used with high reliability in power system. This kind of relay is reported that it has a reliable detection ability, even so high impedance faults take place in transmission line. Therefore it is expected to use and expand widely in many utilities. Tripping of the relay is decided according to the difference between differential and restraint current. However the tripping criterion can be changed by the manufacturers. This paper presents an operational scheme of current differential relay for transmission line protection with graphical model. It is developed for educational purpose for students interesting in power system and protection engineer in utility. MATLAB is used to establish the models.

  • PDF

Control Strategy against Undesirable Zone 3 Relay Operation in Voltage Instability

  • Lee Byong-Jun;Song Hwa-Chang
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.144-151
    • /
    • 2005
  • This paper presents a framework for determining control strategies against unwanted tripping actions during relay operation that plays a very important role in cascading events leading to voltage collapse. The framework includes an algorithm for quick identification of possible zone 3 relay operation during voltage instability. Furthermore, it comes up with the control strategy of load shedding at the selected location with active power and relay margin criteria. In addition, Quasi Steady-State (QSS) simulation is employed to obtain time-related information that is valuable in the determination of control strategy. As a case study, an example applying the framework is shown with the modified New England 39-bus system.

송전선로 보호용 보호계전기 시험을 위한 계통모델 개발에 관한 연구 (A Study of the Development of Power System Model for Performance Test of Transmission Line Protective Relay)

  • 서훈철;이홍학;김철환;이재욱;장병태;곽노홍;김호표;김일동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.430-432
    • /
    • 2004
  • The standard power system model is needed to test a transmission line protective relay There are two methods to develop a power system model for transmission line protection. First method is based on characteristic power system model, and second method is based on functional power system model. This paper presents a standard power system model for performance test of transmission line protective relay, where the power system model is based on the two methods. And this model is simulated by using RTDS to test a protective relay.

  • PDF