• Title/Summary/Keyword: relay system

Search Result 1,269, Processing Time 0.027 seconds

LED Communication-based Multi-hop Wireless Transmission Network System (LED 통신기반 멀티 홉 무선 전송네트워크시스템)

  • Jo, Seung-Wan;Dung, Le-The;An, Beong-Ku
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.37-42
    • /
    • 2012
  • LED is just a semiconductor which can produce light. Currently, there are active research works on LED lighting technologies according to the growth of energy-saving environmental industry. Especially, LED communication is one of the active research works in these fields. In this paper, we design a LED communication-based multi-hop transmission wireless network system. The designed system consists of a transmission circuit system(transmitter) using LED and a receiving circuit system(receiver) using PD(photo detector) and OP-Amp, and relay system which can support multi-hop wireless network service with PD, OP-Amp, and LED, respectively. The experiments for the designed system are performed as follows. One computer is connected at the end of transmitter and receiver, respectively. There are two relays between transmitter and receiver, and text files are transmitted continuously by using text transmission programming. In this experiment, we test the performance with various baud rates, transmission ranges.

A study on analysis of DVR(Dynamic Voltage Restorer) in electric traction network by using the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 전기철도급전계통에 DVR(Dynamic Voltage Restorer)해석에 관한 연구)

  • Choi, J.H.;Kim, J.C.;Park, S.M.;Kim, T.S.;Choo, D.W.;Chung, I.Y.;Park, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.283-286
    • /
    • 2003
  • The electric traction load is quite differ from general power system load which is single-phase, high-speed heavy load receiving power from 3-phase power system and also has variable load characteristics over time and space. Therefore, there are inevitably power quality problems such as steady state or transient voltage drop, voltage imbalance and harmonic distortion. In addition, it is expected that transient voltage sag could affect the safety of feeding system. Thus, in this paper transient analysis and voltage sag compensation of AT(Auto Transformer) feeding system are studied. The fault study of traction network is analysed by using PSCAD/SMTDC simulation tool. In addition, application of DVR in electric traction system is proposed to compensate the voltage sag of traction network which is occurred by the fault of utility source. The results of fault study will be a useful research works for operation and setting of electric traction relay. Also, it can be shown that application of the DVR in electric system is very useful to compensate the voltage sag from the result of related simulated work. The results of study will be a useful research works for management and planning of power quality in electric traction system.

  • PDF

Modulation Scheme for Network-coded Bi-directional Relaying over an Asymmetric Channel (양방향 비대칭 채널에서 네트워크 부호화를 위한 변조 방식)

  • Ryu, Hyun-Seok;Kang, Chung-G.
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.2B
    • /
    • pp.97-109
    • /
    • 2012
  • In this paper, we propose a modulation scheme for a network-coded bi-directional relaying (NBR) system over an asymmetric channel, which means that the qualities of the relay channel (the link between the BS and RS) and access channel (the link between the RS and MS) are not identical. The proposed scheme employs a dual constellation in such a way that the RS broadcasts the network-coded symbols modulated by two different constellations to the MS and BS over two consecutive transmission intervals. We derive an upper bound on the average bit error rate (BER) of the proposed scheme, and compare it with the hybrid constellation-based modulation scheme proposed for the asymmetric bi-directional link. Furthermore, we investigate the channel utilization of the existing bi-directional relaying schemes as well as the NBR system with the proposed dual constellation diversity-based modulation (DCD). From our simulation results, we show that the DCD gives better average BER performance about 3.5~4dB when $E_b/N_0$ is equal to $10^{-2}$, while maintaining the same spectral efficiency as the existing NBR schemes over the asymmetric bi-directional relaying channel.

A Study for Faliure Examples Involved Diode, Thermo Sensor and Wiring Short of Electronic Control A/C System in a Vehicle (승용자동차 전자제어 에어컨 장치의 다이오드, 써모센서와 배선단락에 대한 고장사례 고찰)

  • Lee, IL Kwon;Kook, Chang Ho;Ham, Sung Hoon;Lee, Jeong Ho;Moon, Hak Hoon;You, Chang Bae;Hwang, Han Sub;Lim, Chun Moo;Jung, Dong Hwa;Na, Yun Whan
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.83-88
    • /
    • 2017
  • The purpose of this paper is to study for a failure examples producing in electronic control air conditioner in vehicle. The first example, it looked for the repetitive fuse cutting phenomenon that the diode using for a surge voltage prevention of inner A/C relay damaged because of no absorbing the surge voltage by short of diode when the A/C is off. The second example, it knew the icing phenomenon of evaporator that the A/C ECU didn't control the A/C because of inner cutting of fin thermo sensor. The third example, it verified the operation trouble phenomenon because of the A/C switch and for sensor burned in flames by short phenom enon when the sheath of the cable has peeled off. Therefore, the driver have to manage the optimism system of a car by thoroughgoing inspection and improvement the failure phenomenon.

Implementation and Performance Evaluation of the Smart Meter Concentrator Control Protocol for Advanced Metering Infrastructure (차세대 검침 기반구조를 위한 스마트 미터 집중기 제어 프로토콜의 구현과 성능분석)

  • Jang, Soon-Gun;Choi, In-Ji;Park, Byoung-Seok;Kim, Young-Hyun;Yoon, Chong-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.3
    • /
    • pp.41-49
    • /
    • 2011
  • In this paper, we propose an open protocol to be employed between a smart meter concentrator and a metering data collection server, and also evaluate its performance. Legacy concentrators performs the connection establishment and data gathering operations with DLMS/COSEM protocol standards. However, we note that there are no standardized protocols between the concentrator and the collection server, which inevitably conduces each commercial smart metering system to have its own proprietary protocol. In order to solve this problem, we propose an open protocol - Smart Meter Concentrator Control Protocol(SMCCP) by extending the existing standard protocol(DLMS/COSEM). The SMCCP can provide the proxy mode to enable efficient transmission between the concentrator and the data collection server. It also can support the relay mode to enable a direct communication between the data collection server and each far end smart meter. We also implement an emulator system and a protocol analyzer to provide its operation. In addition, we evaluate the session holding time and the link usage ratio in both relay and proxy modes with OMNET++ simulator.

A study on the Development of Automatic Drying System of Ginseng (인삼의 자동건조시스템 개발에 관한 연구)

  • Kang, Hyun-Ah;Chang, Kyu-Seob;Chang, Dong-Il
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.764-768
    • /
    • 1993
  • This study was developed a computer-controlled automatic drying system. In order to control automatically the temperature, relative humidity weight of the sample, drying system with computer and connecting parts such as microcomputer, PC-Lab card, Op. Amp., and relay system were developed for controlling the heater, fan, humidifier and dehumidifier. Using this system, drying characteristic mechanism of ginseng were investigated. The increase of drying temperature decreased Hunter L value and increased a and b value. The hardness and shrinkage rate of white ginseng had a increasing tendency with the increase of drying temperature. Crude saponin content was not affected by drying temperature and relative humidity.

  • PDF

Signal Interlocking System of a Programmable Logic Controller Improvement Report (신호보안설비 전자연동장치(PLC) 개선 관련 보고)

  • Seok, Tae-Woo;Ko, Yang-Og;Yoo, Do-Gyun
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.623-628
    • /
    • 2007
  • Metro Subway System is widely known as the leader of public transportation in a metropolitan area. The signal interlocking is one of the most important organs that plays a major role in the system. By improving the quality of signal interlocking on of the traffic system and keeping its maintenance on a high level will not only repair the current state, but it will also let the PLC(Programmable Logic Controller). The Non-Vital relay of No. 3, 4 Line are the most one of the unstable system, device, which underwent a process of fine manufacture establishment and a close examination, obtained as a new device. Utilizing the equipment with cautious preservation on the system will enhance the current state of the signal device. Especially, the test for improvement and development based upon the technique that decreases the frequency of defect produced will further precipitate its efficiency. With authorization of imposing the newly made equipment will bring improvement to the signal technology and to the industry at largest extent.

  • PDF

Video Digital Doorlock System for Recognition and Transmission of Approaching Objects (접근객체 인식 및 전송을 위한 영상 디지털 도어락 시스템 설계)

  • Lee, Sang-Rack;Park, Jin-Tae;Woo, Byoung-Hyoun;Choi, Han-Go
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.3 no.6
    • /
    • pp.237-242
    • /
    • 2014
  • Current digital door lock systems are mainly designed for users' convenience, so they have weakness in security. Thus, this paper suggests a video digital doorlock system grouped with a relay device, a server, and a digital doorlock with a camera, sensors, and communication modules, which is detecting or recognizing objects approaching to the front of the door lock system and sending images and door-opening information to users' smart devices. Experiments showed that the suggested system has 96~98% recognition rate of approaching objects and requires 17.1~23.9 seconds for transmission on average, depending on network systems. Therefore, the system is thought to have enough capability for real time security response by monitoring the front area of the doorlock system.

Infrared Dual-field-of-view Optical System Design with Electro-Optic/Laser Common-aperture Optics

  • Jeong, Dohwan;Lee, Jun Ho;Jeong, Ho;Ok, Chang Min;Park, Hyun-Woo
    • Current Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.241-249
    • /
    • 2018
  • We report a midinfrared dual-field-of-view (FOV) optical system design for an airborne electro-optical targeting system. To achieve miniaturization and weight reduction of the system, it has a common aperture and fore-optics for three different spectral wavelength bands: an electro-optic (EO) band ($0.6{\sim}0.9{\mu}m$), a midinfrared (IR) band ($3.6{\sim}4.9{\mu}m$), and a designation laser wavelength ($1.064{\mu}m$). It is free to steer the line of sight by rotating the pitch and roll axes. Our design co-aligns the roll axis, and the line of sight therefore has a fixed entrance pupil position for all optical paths, unlike previously reported dual-FOV designs, which dispenses with image coregistration that is otherwise required. The fore-optics is essentially an achromatized, collimated beam reducer for all bands. Following the fore-optics, the bands are split into the dual-FOV IR path and the EO/laser path by a beam splitter. The subsequent dual-FOV IR path design consists of a zoom lens group and a relay lens group. The IR path with the fore-optics provides two stepwise FOVs ($1.50^{\circ}{\times}1.20^{\circ}$ to $5.40^{\circ}{\times}4.32^{\circ}$), due to the insertion of two Si lenses into the zoom lens group. The IR optical system is designed in such a way that the location and f-number (f/5.3) of the cold stop internally provided by the IR detector are maintained when changing the zoom. The design also satisfies several important performance requirements, including an on-axis modulation transfer function (MTF) that exceeds 10% at the Nyquist frequency of the IR detector pitch, with distortion of less than 2%.

Design of Operating System for Wireless Sensor Nodes with Enhanced Remote Code Update Functionality (원격 코드 업데이트가 가능한 무선 센서 노드용 운영체제)

  • Kim, Chang-Hoon;Cha, Jeong-Woo;Kim, Il-Hyu
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.16 no.1
    • /
    • pp.37-48
    • /
    • 2011
  • Sensor networks monitor the environment, collect sensed data, and relay the data back to a collection point. Although sensor nodes have very limited hardware resources, they require an operating system that can provide efficient resource management and various application environments. In addition, the wireless sensor networks require the code update previously deployed to patch bugs in program and to improve performance of kernel service routines and application programs. This paper presents EPRCU (Easy to Perform Remote Code Update), a new operating system for wireless sensor nodes, which has enhanced functionalities to perform remote code update. To achieve an efficient code update, the EPRCU provides dynamic memory allocation and program memory management. It supports the event-driven kernel, which uses priority-based scheduling with the application of aging techniques. Therefore, the proposed operating system is not only easy to perform wireless communication with the remote code update but also suitable for various sensor network applications.