• Title/Summary/Keyword: relative-size

Search Result 2,119, Processing Time 0.031 seconds

Production and High Temperature Mechanical Properties of Ti-TiC Composite by Reaction Milling (반응밀링법에 의한 Ti-TiC 복합재료의 제조 및 고온 기계적 특성)

  • Jin, Sang-Bok;Choe, Cheol-Jin;Lee, Sang-Yun;Lee, Jun-Hui;Kim, Sun-Guk
    • Korean Journal of Materials Research
    • /
    • v.8 no.10
    • /
    • pp.918-924
    • /
    • 1998
  • This study has been carried out to investigate the effect of reaction milling time on the synthesis of Ti- TiC p powder synthesised from the elemental titanium and activated carbon by reaction milling(RM), and the effect of vacu­u urn hot pressing temperature and TiC volume fraction on microstructural and mechanical properties of Ti- TiC com­p posite $\infty$ns이idated by vacuum hot pressing(VHP).T The elemental powders of titanium and activated carbon can be converted into Ti- TiC composite powders by reac­t tion milling for about 300hours, and were the average grain size of the as- milled powders has been measured to be a about $5\mu\textrm{m}$. The relative density of Ti- TiC VHPed above $1000^{\circ}C$ during Ihr is about 98% and the mechanical properties o of In- situ Ti- TiC composites are improved by TiC particle dispersed uniformly on titanium matrix. In order to investi­g gate thermal stability of Ti- TiC composite, after annealing at $600^{\circ}C$ for 80hrs micro- Vickers hardness have been per­f formed, and the values have been shown little changed as compared with those before annealing. The compact has b been tested on high temperature compressive test at $700^{\circ}C$ and has showed a high temperature compressive strength of 330MPa in a Ti- 20vol% TiC.

  • PDF

Slow Sorption of Hydrophobic Organic Contaminants in Natural Soils (자연토양에서의 소수성 유기오염물질의 느린 흡착)

  • Shin, Won Sik;Park, Taehyo;Ahn, Taebong;Chun, HeeDong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.1
    • /
    • pp.103-114
    • /
    • 2001
  • Sorption studies were conducted to determine if slow sorption fraction is observed in recent1y deposited organic matter by studying wetland soils explicitly. Sorption characteristics of hydrophobic organic compounds (chlorobenzene and phenanthrene) in recently deposited freshwater marsh soils were determined using a batch sorption procedure. Relative indicators of organic matter age were assessed using several techniques including the ratio of elemental oxygen to carbon in the organic matter. Slow sorption characteristics for both surface marsh soil (top 0-2 cm, <5 years old) and deeper marsh soil (below 10-cm, >20 years old) were compared against relatively older PPI (Petro Processors, Inc. Superfund site) and BM (Bayou Manchac) soils to investigate whether soil age can cause differences in sorption of organic compounds in wetland soils. Increases in sorption non-linearity of slow sorption model parameters (increase in KF and decrease in N) explain the existence of slow sorption fraction. The results of slow sorption model indicates the presence of a sizable slow sorption fraction; 25.4 - 26.3% (chlorobenzene) and 1.4 - 1.9% (phenanthrene) of the sorbed mass in wetland soils and 40.0 - 55.93% (chlorobenzene) and 2.9 - 3.19% (phenanthrene) of the sorbed mass in PPI and BM soils, respectively. The slow sorption fraction increased in the order of surface < deeper < PPI < BM soil indicating that size of the slow sorption fraction increases with soil organic matter age.

  • PDF

Embodiment of High Impedance Surface of Meta-Material Characteristic Using Symmetrical AMC Structure and Its SAR Analysis (대칭형 인공자기도체 구조를 이용한 메타물질 특성의 고임피던스 표면 구현 및 SAR 특성 분석)

  • Lee, Seungwoo;Lee, Moung-Hee;Rhee, Seung-Yeop;Kim, Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.9
    • /
    • pp.744-750
    • /
    • 2013
  • In this paper, we proposed new type of an artificial magnetic conductor(AMC) structure, which has a high impedance surface for realizing the meta-material characteristics. The designed AMC structure set a goal of 3.2GHz, and the reflector, which consists of periodically arrayed AMCs is fabricated and measured. The high impedance improves the reflection coefficient, decreases the system size and interference, and increases the antenna performance. The structure has embodied the high impedance by the thickness and relative permitivity of the dielectric substrate and the design configuration without the metallic via hole which connects the AMC to the GND. The bandwidth is 150% broader than the similar AMC structures. Also, the distance between the antenna and the AMC reflector is decreased by ${\lambda}/10$ as working as the metal(PEC) reflectors. The antenna radiation characteristics are 3dB increased at 10mm away from reflector by measurement. The proposed reflector could be inserted in the portable mobile devices, and the antenna's performance has improved by the reflector. The specific absorption rate is dramatically decreased over 94% because the back radiation of the antenna is shielded.

A Statistical Study Evaporation tn DAEGU Area (대구지방의 증발량에 대한 통계학적 연구)

  • 김영기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.15 no.4
    • /
    • pp.3160-3169
    • /
    • 1973
  • Rainfall, evaporation, and permeability of water are the most important factors in determining the demand of water. The Daegu area has only a meteorologi observatory and there is not sufficient data for adapting the advanced method for derivation of the estimated of evaporation in the Daegu area. However, by using available data, the writer devoted his great effort in deriving the most reasonable formula applicable to the Daegu area and it is adaptable for various purposes such as industry and estimation of groundwater etc. The data used in this study was the monthly amount of evaporation of the Daegu area for the past 13 years(1960 to 1970). A year can be divided into two groups by relative degrees of evaporation in this area: the first group (less evaporation) is January, February, March, October, November, and December, and the second (more evaporation) is April, May, June, July, August, and September. The amount of evaporation of the two groups were statistically treated by the theory of probability for derivation of estimated formula of evaporation. The formula derved is believed to fully consider. The characteristic hydrological environment of this area as the following shows: log(x+3)=0.8963+0.1125$\xi$..........(4, 5, 6, 7, 8, 9 month) log(x-0.7)=0.2051+0.3023$\xi$..........(1, 2, 3, 10, 11, 12 month) This study obtained the above formula of probability of the monthly evaporation of this area by using the relation: $F_(x)=\frac{1}{{\surd}{\pi}}\int\limits_{-\infty}^{\xi}e^{-\xi2}d{\xi}\;{\xi}=alog_{\alpha}({\frac{x_0+b'}{x_0+b})\;(-b<x<{\infty})$ $$log(x_0+b)=0.80961$ $$\frac{1}{a}=\sqrt{\frac{2N}{N-1}}\;Sx=0.1125$$ $$b=\frac{1}{m}\sum\limits_{i-I}^{m}b_s=3.14$$ $$S_x=\sqrt{\frac{1}{N}\sum\limits_{i-I}^{N}\{log(x_i+b)\}^2-\{log(x_i+b)\}^2}=0.0791$$ (4, 5, 6, 7, 8, 9 month) This formula may be advantageously applied to estimation of evaporation in the Daegu area. Notation for general terms has been denoted by following: $W_(x)$: probability of occurance. $$W_(x)=\int_x^{\infty}f(x)dx$$ P : probability $$P=\frac{N!}{t!(N-t)}{F_i^{N-{\pi}}(1-F_i)^l$$ $$F_{\eta}:\; Thomas\;plot\;F_{\eta}=(1-\frac{n}{N+1})$$ $X_l\;X_i$: maximun, minimum value of total number of sample size(other notation for general terms was used as needed)

  • PDF

COLOR DIFFERENCE OF THE DENTAL COMPOSITES MEASURED BY DIFFERENT COLOR MEASURING INSTRUMENTS (복합레진 색상의 측정 기기에 따른 차이)

  • Park, Su-Jung;Noh, Eun-Young;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.199-207
    • /
    • 2009
  • The objective of this study was to evaluate the effect of color measuring instrument by measuring the color of dental composite resins. Nine shade light cured composite resin disks were prepared (diameter : 15 mm, thickness : 4 mm). CIE $L^*a^*b^*$ color scale of each disk was measured with 3 different types of spectrophotometer [MiniScan XE plus (Model 4000S, Hunter Lab, USA), CM-3500d (Minolta, Japan) and Specbos 2100 Miniature VIS Reflection spectrometer (Serial No: 319416, JETI Technishe VIS Instrumentic GmbH. Germany)]. Miniscan XE Plus and CM-3500d using identical measuring geometry with different size of viewing aperture. But Specbos 2100 using different measuring geometry. Within the limitation of this study, there were color difference (${\Delta}E^*$) from 2.4 to 7.8 between Miniscan XE Plus and CM-3500d, but $L^*$, $a^*$, $b^*$ values showed the high correlation. However, there were great color difference (${\Delta}E^*$) in the extent of about 20 between instruments with the different measuring geometry. Therefore, color scale measured by color measuring instrument should be used as a relative value rather than an absolute value in the field of dentistry.

A Study on the Efficiency Analysis for the Automotive Parts Manufacturer Using Data Envelopment Analysis (DEA를 활용한 자동차부품 기업의 효율성 평가에 관한 연구)

  • Cho, Hyung-Kook;Lee, Cheol-Gyu;Yoo, Wang-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.609-615
    • /
    • 2014
  • Due to the recent global recession, the car industry demand levels have plummeted which led to a crisis in the automotive parts industry for the first time in history. Since the fourth quarter of 2008, the automotive parts manufacturers in America have faced a record loss and those in Japan and Europe who also had a strong track record are facing a weak economy. In addition, the domestic automotive parts industry is also affected by the global economic crisis. This research is that the relative efficiency analysis utilizing the DEA has done on the object of 25 small and medium-sized automotive parts manufacturers publicly listed, As the efficiency analysis result 6 of 25 manufacturers are efficient in CCR model and 12 manufactures have shown efficiency in BCC model, the efficiency analysis in consideration of the manufacturer size. The manufacturers with efficiency 1 in 25 manufacturers are DMU 1, 5, 7, 10, 18, 24 and the relatively benchmarking objects in other manufactures are DMU 1, 10, 24, Based on the results of this research, a direction to the domestic automotive parts manufacturers as well as a significant information will be provided in managing the companies in the future by the improvement of management efficiency through the practical efficiency analysis.

Fabrication of $Li_2B_4O_7$ Series Single-Crystal TLDs and their TL properties ($Li_2B_4O_7$ 계열 단결정 TLD 소자의 제작과 특성)

  • Park, Myeong-Hwan;Park, Kang-Soo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • High-quality single crystals of pure $Li_2B_4O_7$ as well as $Li_2B_4O_7$ doped with Cu, Mn and Mg impurities (1.0mol%, respectively) have been grown from the melt of $Li_2CO_3+2B_2O_3$ by Czochralski method in platinum crucibles. To study the thermoluminescent properties, $Li_2B_4O_7$ series single crystal TLDs were made by cutting in the size of $4{\times}5{\times}1\;mm^3$. The glow curves show two or three peaks which can be easily deconvoluted. It is observed that room temperature($20{\sim}30^{\circ}C$) fadings of the dosimetric peaks of $Li_2B_4O_7$ series single crystal TLDs were about 10 % for 30 days. The relative photon energy response for $Li_2B_4O_7$ series single crystal TLDs were about 85 % when the responses were normalized to that measured with $^{60}Co\;(1.25\;MeV)\;{\gamma}-rays$. The measured data are in a good agreement with theoretical ones. The $Li_2B_4O_7$ series single crystal TLDs fabricated in this work can be used for monitoring personal and environmental radioactivity.

  • PDF

A Study on the Reasonable Personnel Management of Radiology Department -Centering around the General Hospitals in Seoul- (진단방사선과(診斷放射線科)의 적정인력(適正人力) 관리(管理)에 관(關)한 연구(硏究) -서울시내 종합병원(綜合病院) 중심(中心)으로-)

  • Chung, Soon-Kuy
    • Journal of radiological science and technology
    • /
    • v.11 no.2
    • /
    • pp.27-64
    • /
    • 1988
  • Most hospital administrators in our country have doubted whether or not the size of their hospital personnel staffs, and the personnel management styles implemented are efficient or not. Actually, increased personnel expenditures due to sophisticated specialization of medical practices has become the biggest hospital expense. Therefore, it is said that hospitals can be run move efficiently by implementing reasonable management strategies for hospital personnel management. In this paper, the departments of diagnostic radiography in 16 general hospitals in Seoul, which were classified into 4 groups by the scale of hospital beds, were used as sample cases. Then, the data for the number of X-ray examination by diagnostic item was collected from sample hospitals. The unit hour spent on X-ray examinations in each diagnostic service was quoted from "A Study on setting-up of the relative value units of medical services and on the structure of current fee schedules" written by Mr. Ik Je Seong. The data analysis results are as follows; First, the number of hours per day spent on X-ray examinations in 13 hospitals out of 16 hospitals, was shorter than the general daily working hours (8 hours). Second, in the morning there was not enough time to work for X-ray examinations required, with the available manpower. In the afternoon, however, the situation was diametrically opposed to that in the morning. Third, in light of above results, though most hospitals employ sufficient personnel for the quantity of the actural work, they were always short-handed where their works were performed Fourth, this study tells us that there is a maldistribution of the work in the schedule : too much work for the available personnel in the morning. The following recommendations are resulted from the data analysis described above. First, it is recommended that all out-patients coming again, except specific patients(G. B. or I.V.P. etc) who have to have their X-ray examinations on an empty stomach in the morning among out-patients, be required to visit the hospital in the afternoon. Second, it is recommended that all new out-patients be required to make a reservation in order to equalize the number of patients throughout the day. Third, it is recommended that all in-patients, except specified patients, be arranged to have their X-ray examinations in the afternoon. Fourth, it is recommended that part time workers be employed during peak hours. This recommendation, if applied in a wider scale, would allow hospitals to overcome the problem of the maldistribution of work and personnel, and then more efficient hospital management through the appropirate personnel management procedures could be expected.

  • PDF

Identification and Characterization of Aspergillus oryzae Isolated from Soybean Products in Sunchang County (순창군 장류로부터 분리된 황국균의 동정 및 특성)

  • Lim, Eunmi;Lee, Ji Young;Elgabbar, Mohammed A. Abdo;Han, Kap-Hoon;Lee, Bo-Soon;Cho, Yong Sik;Kim, Hyoun-Young
    • The Korean Journal of Mycology
    • /
    • v.42 no.4
    • /
    • pp.282-288
    • /
    • 2014
  • In this study, we attempted to isolate fungi from soybean fermented foods produced in Sunchang County and to identify Aspergillus oryzae from fungal isolates. Ten fungal isolates were identified with ${\beta}$-tubulin gene. According to the sequences of ${\beta}$-tubulin gene, ten fungal isolates were identified as A. oryzae/flavus complex. For further identification of the ten of fungal isolates, omtA gene, one gene of the aflatoxin biosynthesis gene cluster, was sequenced and the sequences were compared with those of A. oryzae and A. flavus strains from the GenBank database. In addition, identification of the ten fungal isolates was further confirmed using the PCR amplicon of norB and cypA intergenic region, in which a deletion was recognized relative to A. flavus and A. parasiticus. The amplicon size of the ten fungal isolate strains was smaller than those of A. flavus and A. parasiticus, but the same as that of the reference A. oryzae strain. These results indicated that the ten isolates should be identified as A. oryzae. The protease activity in rice koji made with 6, 13, 17, 27, 37 and 38 of strain, respectively was twice higher than that in control. The kojis made with nine of the A. oryzae isolates, respectively, did not produce aflatoxin, suggesting that the strains could possibly be used as starters for soybean products.

Characteristics of Flux Decline in Microfiltration Capillary Membrane of Bentonite Colloidal Suspensions (정밀여과 모세관 막을 이용한 벤토나이트 콜로이드 현탁액의 투과유속 감소특성)

  • Nam Suk-Tae;Han Myeong-Jin
    • Membrane Journal
    • /
    • v.15 no.1
    • /
    • pp.52-61
    • /
    • 2005
  • Permeate flux decline in a microfiltration was analyzed by measuring the permeability of bentonite colloidal solution through polyethylene capillary membranes. The flux decline with time was due to the growth of cake layer on the membrane surface and to the pore blocking by particles. As the time approaches to steady state, the permeate flux is almost controlled by the cake filtration model. Faster flux decline at high trans-membrane pressure was attributed to the formation of denser packed cake layer and pore blocking. The ratio of permeate flux to the initial permeate flux, J/J₁, decreased with increasing the trans-membrane pressure, from 45% for 0.5 kg/sub f//㎠ to 38% for 2.0 kg/sub f//㎠. In comparing the ratio of each fouling component to the total fouling for the 0.5 kg/sub f//㎠ TMP condition, complete blocking was 23.4%, standard blocking was about 14.6% and cake filtration was 62.0%, respectively. Permeate flux through the membrane increases with cross flow velocity, and the effect of the variation of velocity is more significant at 1.0 kg/sub f//㎠ rather than at 2.0 kg/sub f//㎠ of the operation pressure. Permeate flux for the membrane having the average pore diameter of 0.34 ㎛ was higher than that for the membrane of 0.24 ㎛ pore size, with the higher flux with the low concentration of feed. On the operation using the membrane of 0.34 ㎛ pore, the pore blocking in the low concentration of 200 ppm is negligible relative to the pore blocking in the 1000 ppm feed.