• Title/Summary/Keyword: relative type

Search Result 2,457, Processing Time 0.029 seconds

An Analysis of Financial Statement Among Urban Households Based On a System Approach (체계론에 기초한 도시가계의 재정상태 분석)

  • 양정선
    • Journal of the Korean Home Economics Association
    • /
    • v.30 no.1
    • /
    • pp.237-255
    • /
    • 1992
  • The purpose of this study was to investigate relations of resources and demands, family financial management and financial statement of urban households by applying a system approach. The results of this study were as follows; Saving rate had significant differences according to resources variables such as age, family life cycle, occupation of househead and housewife, ratio of employed to family member, and to demands variabels such as subjective prospect of business cycle, and value orientation, whereas total saving amount had significant differences according to resources vaiables such as age, family life cycle, educational level, percapita income, occupation of househead, type of income and to demand variable, perception of relative income. Also average monthly saving amount had significant differences according to resources vaiables such as educational level, per capita income, occupation of housewife, housing ownership, ratio of employed to family member, ratio of dependent to employed, and to demands variable, perception of relative income. The stocks had significant differences according to resources variables such as age, family life cycle, educational level, per capita income, occupation of househead, type of income, and housing ownership. Finally, real estate had significant differences according to resources variables such as age, family life cycle, educational level, percapita income, occupation of househead, type of income, housing ownership, and to demands variable, perception of relative income. Financial Statement among urban households according to family financial management had significant differences. And among all variables affecting financial statement among urban households, per capita income had the highest effect and perception of relative income was the second.

  • PDF

Influence of the Monitoring Interval and Intake Pattern for the Evaluation of Intake (내부피폭 감시주기 및 섭취형태가 방사성핵종 섭취량 평가에 미치는 영향)

  • Jong-Il Lee;Tae-Young Lee;Si-Young Chang;Jai-Ki Lee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.53-59
    • /
    • 2004
  • A variety of factors such as the pattern of intake (acute or chronic), monitoring interval and the characteristics of the radionuclides could have a significant influence on the estimates for the intake and internal dose. The relative differences of the assessed intakes based on the assumption of an acute intake to that of a chronic intake were evaluated by using the predicted bioassay quantity in the whole body or organs for an acute and chronic intake through the inhalation of $^{125}$ I, $^{137}$ C, $^{235}$ U with the AMAD of 1 ${\mu}{\textrm}{m}$ and 5 ${\mu}{\textrm}{m}$ for the monitoring intervals of 7, 14, 30, 60, 90, 120, 180, 360 days, respectively, The relative difference of the assessed intakes based on the intake pattern is affected by the monitoring interval, radionuclide and absorption type, but the particle size has little influence on the difference of the assessed intakes based on the intake pattern. The maximum monitoring interval, which is defined as the monitoring interval that the relative difference of the assessed intakes based on the assumption of an acute intake to that of a chronic intake is less than 10%, is 60 d for $^{125}$ I with Type F, 180 d for $^{137}$ C with Type F, 90 d for $^{235}$ U with Type M, and 360 d for $^{235}$ U with Type S. It was concluded that an intake pattern has little influence on the estimates of the assessed intake in the case where the monitoring interval is shorter than the maximum monitoring interval for each radionuclide.

  • PDF

A Numerical Study on the Performance Analysis of Plume Abatement Cooling Tower with Dry Type Heat Exchanger (건식 열교환기를 이용한 백연방지 냉각탑 성능의 수치해석적 연구)

  • 김병조;최영기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1018-1027
    • /
    • 2003
  • This study treats the analysis of the performance and the design of plume abatement wet/dry cooling tower with dry type heat exchanger using a numerical method. A two-dimensional analysis is performed using the finite volume method for mechanical draft counterflow and crossflow tower. For a coupling problem between water and air system, a turbulent two phase flow is considered. Effectiveness-NTU method is used for modeling of the dry type heat exchanger. The parameter change simulations of the outer wall shape, the relative flowrate of air, and attachment of an air mixer are performed to examine the effect on plume abatement. It is found that if the relative air flowrate ratio and the adequate air mixer type are chosen well in addition to the ratio of water to air flowrate, the loss of the cooling capacity and the additional cost are reduced and the plume is abated.

A Study on Standard Testing Method for Type Approval of DSC Using MF/HF (MF/HF용 DSC의 형식검정을 위한 표준 시험방법)

  • 이동식;김기문
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.4
    • /
    • pp.63-82
    • /
    • 1995
  • This paper is a study on standard testing method for type approval of DSC which is the main structure of the terrestrial communication. As authority inspecting offices and producers have no experience for type approval of relative equipments as adapting GMDSS. In this paper, it is to be improved the understanding for type approval ; a system, standard of technic and testing methods, etc and make better quality of relative equipments. Additionally it could help quality and quantity improvement in all radiocommunication parts. Of course, the regulation for type approval had made but most makers didn't know it correctly, so the method of solution have been studied. By result of this study, with comparision and analysis of structure and a condition of efficiency with adapting GMDSS is could help some problems slove in the field and gave testing method of machinery and tools, electrical conditions, came out measurement and did ways standard efficiency.

  • PDF

Numerical Study on the Performance Analysis of Plume Abatement Cooling Tower with Dry Type Heat Exchanger

  • Kim, Byung-Jo;Choi, Young-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.2
    • /
    • pp.61-70
    • /
    • 2005
  • This study treats the numerical analysis of performance and design for plume abatement wet/dry cooling tower with a dry type heat exchanger. A two-dimensional analysis is performed using the finite volume method for mechanical draft counterflow and crossflow tower. For a coupling problem between water and air system, a turbulent two phase flow is considered. The Effectiveness-NTU method is used for modeling of the dry type heat exchanger. The parametric simulations such as the relative flowrate of air and attachment length of an air mixer are performed to examine the effect on plume abatement. It is found that if the relative air flowrate ratio and the adequate air mixer type are chosen well in addition to the ratio of water to air flowrate, the loss of cooling capacity and the additional cost are reduced and the plume is abated.

Experimental Study for Wave Transmission Coefficients of Submerged Structure : I. Permeable Type Structure (수중구조물의 파고전달계수 산정 실험 : I. 투과형 수중구조물)

  • Lee, Jong-In;Bae, Il Rho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.485-496
    • /
    • 2020
  • Submerged structures such as low-crested breakwaters and artificial reefs have been commonly used for coastal protection. In this study, two-dimensional laboratory experiments were conducted in a wave flume to investigate the wave transmission phenomena of permeable type submerged structures armored by Tetrapods. Different cases of the experimental conditions were included by relative crest depth, relative freeboard, relative crest width, wave steepness and so on. An empirical formula from the experimental data was proposed to predict the wave transmission coefficients over various specifications and structural designs of the permeable type submerged structure. The proposed formula successfully predicted the wave transmission coefficients. In this study, the proposed empirical formula of the wave transmission over the submerged structure was improved from the existing formula.

Spermatogenesis and its fine structure of the seminiferous epithelium in the Jindo dog (진도견(珍島犬) 정세관상피(精細管上皮)의 정자발생(精子發生)과 미세구조(微細構造))

  • Kim, Yong-hwan;Park, Young-seok
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.1
    • /
    • pp.23-36
    • /
    • 1993
  • To investigate the cycle and relative frequences and the fine structure of seminiferous epithelia in mature Jindo dogs, histologic study was performed. The results obtained were summarized as follows; 1. Type A spermatogonia appeared approximately 1.6 times as many at stage II as compared to stage I while type In spermatogonia appeared small amount in stage III, IV and V. type B spermatogonia were found during the stage VI to VIII, though not detectable during stage I to V. The type B spermatogonia divided at stage VII to produce the preleptotene primary spermatocytes at stage VIII. The number of primary spermatocytes of the leptotene phase markedly increased during stage I to II, and the primary spermatocytes of the pachytene phase were shown the least in number at stage IV. The secondary spermatocytes could be seen only at stage IV. 2. The relative frequencies of each stage from stages I to VIII of the cycle of seminiferous epithelia were 31.6, 11.9, 10.0, 3.2, 8.2, 10.1, 11.7 and 13.2% respectively. 3. On electron microscopic observations, acrosomal vesicle of spermatids appeared larger though the bulk of germ cells were the morphologically same as those of the other animal species. Thread line structures light microscopically observed in the cytoplasm of Sertoli cell were the longitudinal orientation of mitochondria.

  • PDF

Effects of the Maghemite for Explosive accident Prevention to Liquefied Petroleum Gas (LPG 폭발사고 예방을 위한 Maghemite의 영향)

  • 박영구
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.67-78
    • /
    • 1996
  • Gas sensing element, $\gamma-Fe_2O_3$was synthesized by dehydration, reduction, and oxidation of $$${\gamma}$-FeOOH, which was synthesized with $FeSO_4\;{\cdot}\;7H_2O$ and NaOH. They were produced as a bulk-type, a thick film-type. Then, their responses and mechanisms of response to the gas of liquefied-petroleum were studied. The qualities of gas sensing elements are decided by the structure and the relative surface area. In the process of $\alpha-FeOOH $synthesis, the effects of reaction conditions as the equivalent ratio, on the structure and the relative surface area of gas sensing element were observed. The changes of the structure were measured with XRD, SEM, TG-DTA and BET. The resistance changes of the synthesized gas sensor in the air were measured. The response ratio were also measured for the changes of working temperature and gas concentration. As a result of analysis with XRD, it was confirmed that the the best conditions for the synthesis of $\alpha -FeOOH$ were equivalent ratio 0.65. The thick film-type element of $\gamma-Fe_2O_3$responded more quickly than the bulk-type did. The structure and the relative surface area of the $\alpha-FeOOH $were confirmed as the important factors deciding gas response charcteristics.

  • PDF

Effect of Relative Humidity and Box Structure on Box Compression Strength (상대습도 및 상자구조에 따른 과실포장용 골판지상자의 압축강도 분석)

  • Jo, Jung-Youn;Shin, Jun-Sub;Kim, Jong-Kyoung;Seo, Young-Bum;Son, Ki-Ju
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.12 no.2
    • /
    • pp.103-108
    • /
    • 2006
  • In order to determine safety factor of corrugated fiberboard boxes for agricultural products, relationship with effect of relative humidity and structure of box types must be defined. The results obtained from the study were summarized as follows; 1. Results show a detrimental effect on bursting strength of corrugated boards with increasing relative humidity of environment. 2. Compression strength of corrugated boards were decreased rapidly after the relative humidity was over 70 percent. 3. Compression strength of corrugated board boxes were greatly depending on the box types. Folder type showed the best performance at higher humidity environment while bliss type was the worst. 4. Further studies are needed in order to expect box compression strength in real distribution environment.

  • PDF

SOBOLEV ORTHOGONAL POLYNOMIALS RELATIVE TO ${\lambda}$p(c)q(c) + <${\tau}$,p'(x)q'(x)>

  • Jung, I.H.;Kwon, K.H.;Lee, J.K.
    • Communications of the Korean Mathematical Society
    • /
    • v.12 no.3
    • /
    • pp.603-617
    • /
    • 1997
  • Consider a Sobolev inner product on the space of polynomials such as $$ \phi(p,q) = \lambda p(c)q(c) + <\tau,p'(x)q'(x)> $$ where $\tau$ is a moment functional and c and $\lambda$ are real constants. We investigate properties of orthogonal polynomials relative to $\phi(\cdot,\cdot)$ and give necessary and sufficient conditions under which such Sobolev orthogonal polynomials satisfy a spectral type differential equation with polynomial coefficients.

  • PDF