• 제목/요약/키워드: relative humid

검색결과 81건 처리시간 0.026초

환경 및 섬유 특성이 멀티레이어 직물시스템의 투습성에 미치는 영향 (Effects of Relative Humidity and Fiber Properties on the Moisture Permeability of Multilayer Fabric Systems)

  • 이수현;박소현
    • 한국의류산업학회지
    • /
    • 제25권1호
    • /
    • pp.119-126
    • /
    • 2023
  • This study aimed to determine the effects of relative humidity and fiber properties on the moisture permeability of multilayer systems by measuring water vapor transmission in the overlapping condition of various fabrics. The results confirmed that the property of the fabric in contact with the humid environment affects the moisture permeability. If the layer facing the humid environment is hydrophobic and the layer facing the dry environment is superhydrophobic, water vapor transmission increases by up to 17.8% compared to the opposite conditions. Comparing the correction values of the water vapor transmission reflecting the thickness of the specimen under the multilayer condition showed that permeability was higher when the hydrophilic or hydrophobic layer was facing the humid environment. The opposite was true from the "push-pull" effect of absorption mechanism. In the case of moisture permeability, the more hydrophilic the surface facing the humid environment, the more permeable that water vapor diffuses and passes through. It was concluded that the "pull-push" effect, in which water vapor diffuses widely through the hydrophilic facing a humid environment and then passes through the hydrophobic layer, contributes to the improvement of permeability. Permeability differed according to the multilayer overlapping condition. When the relative humidity was high, the "pull-push" effect was insignificant. This is caused by water droplets absorption after the partial migration of water due to condensation. These results suggest that the overlapping conditions and properties of fabrics should vary depending on heavy sweating or not.

중온 고습 환경조건에서 부분적으로 냉방되는 실내의 열쾌적성에 대한 분석 : 인체반응에 대한 PPD 기준의 평가 (Analysis on the Thermal Comfort Aspect of a Locally-Cooled Room in Warm and Humid Environments : PPD-Based Evaluation of Human Responses)

  • 김봉훈;서승록
    • 대한인간공학회지
    • /
    • 제17권3호
    • /
    • pp.41-59
    • /
    • 1998
  • Thermal comfort aspect of a locally-cooled target space in warm and humid environments(typically in the rainy summer season) was studied in view of PPD index. First. theoretical analyses were conducted to examine the effect of the governing parameters(such as air temperature, relative humidity and air velocity, etc.) using a computer model. Secondly, experimental investigations were also performed in a climatic room designed to simulate corresponding thermal conditions of outdoor environments. During the tests, temporal variation of PPD was recorded as functions of climatic variables(outdoor and indoor temperatures, relative humidity and air velocity) for the given human factors(metabolic heat generation and clothing). From both theoretical and experimental investigations, air temperature and air velocity were found to be the most dominant parameters affecting PPD of the target space. Results were summarized as: 1. Relative humidity of the locally-cooled target space tends to approach that of outdoor's as the space is subjected to an ON-OFF mode of cooling, since moisture potential of the two rooms reaches an equalized state as a result of moisture diffusion. 2. It was recognized that changes in relative humidity did not show any significance in view of thermal comfort as was reported in the previous studies, while variations of both temperature and air velocity caused relatively large changes in the degree of thermal comfort. 3. In-door environment should be evaluated in terms of PPD instead of relative humidity commonly recognized as an important climatic variable particularly in warm and humid environments.

  • PDF

Curing Behavior of Phenolic Resin with Humid Atmosphere on The Porous $ZrO_2$ ceramics

  • 윤상현;김장훈;김주영;이준태;이희수
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.57.1-57.1
    • /
    • 2011
  • The effects of relative humidity on the properties of the porous $ZrO_2$ ceramics were investigated in terms of the curing behavior of phenolic resin as a binder. The $ZrO_2$ powders containing 5wt% of phenolic resin were conditioned in a consistent chamber condition at a temperature of $50^{\circ}C$ and different humidity levels (25, 50, 75, and 95%) for 1 h. The exposure of humid atmosphere caused changes of density and microstructure in the green bodies. The higher level the powders were exposed to the humid atmosphere, the lower green density was obtained and the more irregular microstructure was observed due to aggregation by the curing of phenolic resin. After firing, the porosity of specimens has risen from 35.7% to 38.1% and Young's modulus has declined in response to the variation of green density. These results could be explained by the degree of resin cure which was associated with the area under the exothermic peak enclosed by a baseline of DSC thermogram curve. Also, the curing behavior of phenolic resin according to relative humidity has been confirmed by decrease of ether groups which have interacted with the phenolic-OH group and the hexamine as a curing agent. Consequently, it could be demonstrated that increase the relative humidity during fabrication of porous $ZrO_2$ diminished the compaction and properties of specimens after firing owing to curing of phenolic resin.

  • PDF

Biomass Structure and Dry Matter Dynamics in a Fire Influencing Montane Subtropical Humid Grassland, Western Ghats Southern India

  • Paulsamy, S;Manian, S.;Udaiyan, K.;Arumugasamy, K.;Nagarajan, N.;Kil, B.S.
    • The Korean Journal of Ecology
    • /
    • 제24권4호
    • /
    • pp.227-232
    • /
    • 2001
  • The biomass structure for three major components viz., the dominant grass, Chrysopogon zeylanicus Thw., the 'other grasses' and the'remaining species'and dry matter dynamics for total community were studied over a period of one year in an annual fire influenced subtropical humid grassland community in Western Ghats, India. The biomass of aboveground, belowground and litter compartments were high as in other humid grasslands and generally have positive correlation with rainfall, rainy days and relative humidity with the exception of litter parts. The above and belowground net primary productions (4,561 and 722 g/㎡, respectively) were also higher and were comparable with other humid tropical grasslands. The turnover of organic matter was rapid, Of the total input of 14.47 g/㎡ into the system, about 86.3% was allocated to above ground parts and 13.7% to below ground parts. The total disappearance was 2.56 g/㎡ and it was accounted to be 17.68% of the total output. The net surplus of dry matter (82.32%) in the post fire community indicates that the grassland was maintained in a seral stage. Hence it is suggested that prescribed burning may keep this ecosystem in a highly productive and seral stage.

  • PDF

미생물 오염 용수 관개에 의한 작물의 오염 위험성 (Irrigation with Microbial-Contaminated Water and Risk of Crop Contamination)

  • 최연식;송인홍;권순국
    • 한국농공학회논문집
    • /
    • 제49권2호
    • /
    • pp.87-97
    • /
    • 2007
  • The aim of this study was to compare crop contamination between two irrigation methods using microbial-contaminated water. The effect of relative humidity on microbial survival of the three indicator microorganisms was also investigated. Escherichia coli ATCC 25922, Clostridium perfringens ATCC 3624, and coliphage PRD1 were applied to irrigation water to grow cantaloupe, lettuce, and bell pepper. Half of the sixteen plots were subsurface drip irrigated (SDI) and the other half were furrow irrigated (FI). Two relative humidity levels were controlled at 15-65 % and 55-80 % for the dry and humid condition experiments, respectively. Samples of produce, surface soil, and subsurface soil at a depth of 10 cm were collected over a two-week period following the application of the study microorganisms. Overall, greater contamination of both produce and soil occurred in the FI plots. For the SDI plots, preferential water paths and resulting water appearance on the seed beds seemed to be responsible for produce contamination. Relative humidity levels did not appear to affect microbial survival in soil. PRD 1 showed lower inactivation rates than 5. coli in both dry and humid conditions. C. perfringens did not experience significant inactivation over the experimental period, suggesting this microorganism can be an effective indicator of fecal contamination.

포스포늄 염을 포함한 폴리스티렌 공중합체의 감습 성질 (Humidity Sensitive Properties of Copolymers of Polystyrene Contains Phosphonium Salts)

  • Paek, Jee-Seon;Gong, Myoung-Seon
    • 한국재료학회지
    • /
    • 제5권6호
    • /
    • pp.715-722
    • /
    • 1995
  • Vlnylbenzyl triphenyl phosphonim chloride (VTPC) 단량체를 감습막으로 사용하기 위하여 합성하였다. 감습막 성분은 서로 다른 조성의 VTPC와 스티렌의 공중합체(VTPC : ST=1 : 0, 7 : 3, 1 : 1, 3 : 7)들이며 감습막의 상대 습도 변화에 대한 전기적 성질의 변화를 측정하였다. 임퍼던스는 감습막중 VTPC의 함량이 증가할수록 감소하였으며, 또한 전극위에 도포한 감습막의 두께가 증가하면 임퍼던스 역시 감소하였다. 감습막중 VTPC와 ST의 성분비가 1대 1인 감습막의 임피던스는 상대습도 70~90%RH 범위에서 12M$\Omega$에서 100K$\Omega$ 사이에서 변하였으며 고습이나 결로를 감지할 수 있는 센서로서 응용이 가능하였다. 15$^{\circ}C$~35$^{\circ}C$범위에서의 은도 의존상수는 -0.5%RH/$^{\circ}C$이었으며 히스테리시스는 $\pm$2%RH의 범위 안에서 나타났다. 응답속도는 상대습도가 75%RH에서 95RH%까지 또는 역으로 변화할 때 40초이었다.

  • PDF

A SIMPLE APPROACH FOR ESTIMATING ANNUAL EVAPOTRANSPIRATION WITH CLIMATE DATA IN KOREA

  • Im Sangjun;Kim Hyeonjun;Kim Chulgyum;Jang Cheolhee
    • Water Engineering Research
    • /
    • 제5권4호
    • /
    • pp.185-193
    • /
    • 2004
  • Estimates of annual actual evapotranspiration are needed in water balance studies, water resources management projects, and many different types of hydrologic studies. This study validated a set of 5 empirical equations of estimating annual actual evapotranspiration with climate data on 11 watersheds, and evaluated the further applicability of these forms in estimating annual runoff on watershed level. Five empirical equations generally overestimated annual evapotranspiration, with relative errors ranging $3.3\%$ to $47.2\%$. The results show that Schreiber formula can be applicable in determining annual evapotranspiration in sub-humid region that is classified by aridity index, while Zhang equation gave better results than the remaining methods in humid region. The mean differences for annual evapotranspiration bias over 11 watersheds are Zhang, Schreiber, Budyko, Pike, and Ol'dekop formula from lowest to highest. The empirical equations provide a practical tool to help water resources managers in estimating regional water resources on ungauged large watershed.

  • PDF

증발기의 압력강하에 대한 상대습도의 영향 (Effects of Relative Humidity on the Evaporator Pressure Drop)

  • 김창덕;강신형;박일환;이진호
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.397-407
    • /
    • 2004
  • It is well known that some key parameters, such as evaporating temperature, refrigerant mass flow rate, face velocity and inlet air temperature, have significant influence on the evaporator performance. However performance studies related to a humid environment have been very scarce. It is demonstrated that the refrigerant mass flow rate, heat flux, water condensing rate and air outlet temperature of the evaporator significantly increase with air inlet relative humidity. As the air inlet relative humidity increases, the latent and total heat transfer rates increase, but the sensible heat transfer rate decreases. The purpose of this study is to provide experimental data on the effect of air inlet relative humidity on the air and refrigerant side pressure drop characteristics for a slit fin-tube heat exchanger. Experiments were carried out under the conditions of inlet refrigerant saturation temperature of 7 $^{\circ}C$ and mass flux varied from 150 to 250 kg/$m^2$s. The condition of air was dry bulb temperature of 27$^{\circ}C$, air Velocity Varied from 0.38 to 1.6 m/s. Experiments Showed that air Velocity decreased 8.7% on 50% of relative humidity 40% of that at degree of superheat of 5$^{\circ}C$, which resulted that pressure drop of air and refrigerant was decreased 20.8 and 8.3% for 50% of relative humidity as compared to 40%, respectively.

여름철 냉방시 상대습도가 쾌적감에 미치는 영향(청년과 고령자의 비교를 중심으로) (Effects of relative humidity on comfort sensation by comparison between the young and the aged)

  • 김동규;금종수;최광환;박희욱;김종열;주익성
    • 설비공학논문집
    • /
    • 제10권4호
    • /
    • pp.381-388
    • /
    • 1998
  • Hot and humid weather in summer generally brings about discomfort. Experiments on which relative humidity makes effects on the comfort sensation were performed to the young and the aged using sensation vote. From July to October 1996, seven college students and eleven aged people were exposed for 2 hours under six different conditions in the Pukyong National University test chamber so as to determine the effects of relative humidity on thermal and comfort sensations. Subjects were wearing same clothes, and the mean clo value was 0.5. The mean radiant temperature was equal to the air temperature and air velocity in the occupied zone around 0.lm/s. In the experiments, it was found that discomfort could be largely reduced when the humidity is controlled to low values in the settled high temperature.

  • PDF

A Study on the Indoor Environmental Factors of Granite Dome Models with Different Envelop Materials during the Summer Season

  • Kong, Sung-Hoon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권1호
    • /
    • pp.65-70
    • /
    • 2001
  • During the summer season, it is very hot and humid in Korea. So the humidity is an important factor regarding the environmental control function of building envelops. The purpose of this research is to measure and analyze the characteristics of such environmental factors as relative humidity, dry bulb temperature and air velocity varies both in the clay and cement envelop structures using granite dome models during the summer time. The interior relative humidity of the clay model is constant regardless of exterior humidity although a little range of variation is shown in comparison to the cement model.

  • PDF