• Title/Summary/Keyword: relative error

Search Result 1,551, Processing Time 0.037 seconds

Estimation of Design Flood Discharge by Areal Ratio for Ungauged Basin (면적비를 적용한 미계측유역에서의 설계홍수량 산정방안)

  • Lee, Jiho;Park, Jaebeom;Song, Yangho;Jun, Hwandon;Lee, Jungho
    • Journal of Wetlands Research
    • /
    • v.19 no.3
    • /
    • pp.335-344
    • /
    • 2017
  • In this study, We proposed a method to estimate the design flood by area ratio in an ungauged basin. For that, the discharge parameters was determined by calibration of observed data at the watershed outlet and then peak flow was estimated by area ratio. In order to verify suggested method, peak flow was compared the observed discharge of the small river basin and the design flood discharge of river implementation projects. The results were summarized as follows. As a result of comparing the discharge by the area ratio and observed discharge, the difference of peak flows were analysed 14 ~ 25%. When the discharge calculated with area ratio of small river was compared with the design flood discharge of river implementation projects, the relative error was analyzed to be less than 20%. It means that suggested method in this study is appropriate.

Comparison Study of Rainfall Data Using RDAPS Model and Observed Rainfall Data (RDAPS 모델의 강수량과 실측강수량의 비교를 통한 적용성 검토)

  • Jeong, Chang-Sam;Shin, Ju-Young;Jung, Young-Hun;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.3
    • /
    • pp.221-230
    • /
    • 2011
  • The climate change has been observed in Korea as well as in the entire world recently. The rainstorm has been gradually increased and then the damage has been grown. It is getting important to predict short-term rainfall. The Korea Meteorological Administration (KMA) generates numerical model outputs which are computed by Global Data Assimilation and Prediction System (GDAPS) and Regional Data Assimilation and Prediction System (RDAPS). The KMA predicts rainfall using RDAPS results. RDAPS model generates 48 hours data which is organized 3 hours data accumulated at 00UTC and 12UTC. RDAPS results which are organized 3 hours time scale are converted into daily rainfall to compare observed daily rainfall. In this study, 9 cases are applied to convert RDAPS results to daily rainfall data. The MAP (mean areal precipitation) in Geum river basin are computed by using KMA which are 2005 are used. Finally, the best case which gives the close value to the observed rainfall data is obtained using the average absolute relative error (AARE) especially for the Geum River basin.

Streamflow Estimation for Subbasins of Gap Stream Watershed by Using SWAT2000 Model (SWAT2000 모형을 이용한 갑천수계의 소유역별 유출량 추정)

  • Moon, Jong-Pil;Kim, Tai-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.5
    • /
    • pp.29-38
    • /
    • 2006
  • Geographic Information System has extended to higher assessment of water resources. GIS linking with hydrological model becomes a trend in water resource assessment modeling. One of the most popular models is SWAT2000 which have effectiveness in multi-purpose processes for predicting the impact of land management practices on water, sediments and chemicals yields in large complex watershed with varying soils, land uses, and management conditions over long period of time. In this study, SWAT2000 model was applied to Gap stream watershed in Daejeon city where TMDL (Total Maximum Daily Load) Regulation would be implanted. The Gap Stream watershed was partitioned into 8 subbasins, however, only 3 out of 8 subbaisns were observed for having practical gauged data on the basis of streamflow from the year of 2002 to 2005. Gauged streamflow data of Indong, Boksu and Hoeduck stations were used for calibration and validation of the SWAT Streamflow simulation. Estimation Efficiency Analysis (COE), Regression Analysis ($R^{2}$), Relative Error (R.E.) were used for comparing observed streamflow data of the 3 subbasins on the daily and monthly basis with estimated streamflow data in order to fix optimized parameters for the best fitted results. COE value for the daily and monthly streamflow was ranged from 0.45 to 0.96. $R^{2}$ values for daily and monthly streamflow ranged from 0.51 to 0.97. R.E. values for total streamflow volume ranged from 3 % to 22.5 %. The accuracy of the model results shows that the SWAT2000 model can be applicable to Korean watersheds like the Gap Stream watershed that needs to be partitioned into a number of subbasins for TMDL regulation.

Study on the Method of Estimating the Accumulation of Co-60 in Consideration of the Operating History of a NPP (원전 운전환경을 고려한 방사성폐기물 내 Co-60 재고량 평가 방안 연구)

  • Kim Tae-man;Whang Joo-ho
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.145-150
    • /
    • 2005
  • To dispose of radwaste in a repository, the safety of disposal must be ensured. This study developed a program for estimating radionuclide accumulation of radwaste, based on the material balance method, one of the indirect methods, and performed application evaluation during the 9th preventive maintenance period of Gori Plant 4, one of the commercial power plants in Korea. First of all, to ensure the technique developed in this study is assessed accurately, this study utilized the data regarding the radionuclide removal in the purification system during the shutdown water chemistry control, and a related estimation technique called SCALP. The target nuclide was Co-60, and it turned out that the relative error was less than $1\%$. The estimation result was compared with the result of direct measurement of the radwaste during the corresponding period as presented by commercial power plants. The result showed that the quantity of Co-60 measured by the direct method was about $50\%$ less than that calculated by the technique developed in this study.

  • PDF

Analysis of DIC Platform and Image Quality with FHD for Displacement Measurement (FHD급 DIC 플랫폼의 변위계측용 영상품질 분석)

  • Park, Jongbae;Kang, Mingoo
    • Journal of Internet Computing and Services
    • /
    • v.19 no.1
    • /
    • pp.105-111
    • /
    • 2018
  • This paper presents the analysis of image quality with FHD(Full HD) resolution camera equipped DIC(Digital Image Correlation) platform for the measurement of the architectural structure's relative displacement. DIC platform was designed based on i.MX6 of Freescale. Displacement measurement based on DIC method, the error is affected by image quality factors as pixel number, brightness, contrast, and SNR[dB](Signal to Noise Ratio). The effect were analyzed. The displacement of ROI(Region Of Interest) area within the image was measured by sub-pixel units based on DIC method. The non-contact telemetry property of DIC method, it can be used to long distance non-contact measurement. The various displacement results was measured and analyzed with the image quality factor adjustment according to the distance(25m, 35m, 50m).

Methodological Study on Measurement of Hydrogen Abundance in Hydrogen Isotopes System by Low Resolution Mass Spectrometry

  • Lia, Jin-Ying;Shib, Lei;Hub, Shi-Lin
    • Mass Spectrometry Letters
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • China's rapid economic growth has resulted in significant environmental side effects. Therefore, China has been interested in reducing her dependence on foreign oil and gas by developing technologies needed for hydrogen, in addition to her increasing energy mix of nuclear and renewable energy form, such as solar and wind power. There are three isotopes of hydrogen, i.e. protium (P or H), deuterium (D), and tritium (T). Both deuterium and tritium are important materials in nuclear fuel cycle industry. Tritium is one of the critical radioactive nuclides. Planning for and implementing contamination control as a part of normal operation and maintenance activities is an important function in any hydrogen facility, especially tritium facility. The development of hydrogen isotopes analysis is the key issues in this area. Mass spectrometry (MS) with medium (about 600) and high resolution (> 1,400) is commercially available; however, the routine analysis of hydrogen isotopes is done with low-resolution MS (< 200) in China. This paper summarizes the progress of MS measurement technology for hydrogen isotope abundance in China, focusing on our lab's research program and technical status. An analyzing method has been introduced for accurate measurement of tritium abundance in the H.D.T system by low resolution MAT-253 MS. The quotient of compression ratio coefficient is determined by building up equipment for laboratory-scale preparation of secondary standard gases and by considering the difference in sensitivity between hydrogen isotopes. The results show that the measured value is reproducible within the relative error range of 0.8% for gas samples of different tritium abundance.

Free Network Adjustment by Application of Generalized Inverse (일반역행예을 이용한 자유망조정)

  • 정영동;강태석;박상진;김욱남
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.3 no.2
    • /
    • pp.48-62
    • /
    • 1985
  • A method for the free network adjustment is proposed, based on the application of generalized inverse matrix (g-inverse). If the network adjustment is executed according to the solution with parameters, especially when all coordinates are considered as parameters to keep unity strength, the matrix of normal equation will be singular. This paper discusses the problem of singular matrix and the analysis of accuracy between conventional method and the free network adjustment of trilateration. In case of the adjustment, the RMS errors of adjusted X, Y coordinates are increased to 35.6% in a polygon, central-point figure, and 50.5% in a quadrilateral. In the elements of error ellipse, the RMS errors are decreased by $\pm$24.5% (a) and $\pm$5.0 % (b) in the polygon, $\pm$42.6% (a) and $\pm$49.2% (b) in the quadrilateral. Introduction of free network adjustment, therefore, could be applied to improvement of relative accuracy in the horizontal positioning.

  • PDF

Estimation of Surface Layer Heat Flux Using the UHF Sensor Installed on UAV (UHF 센서 탑재 UAV를 이용한 지표층 열 플럭스 산출)

  • Kim, Min-Seong;Kwon, Byung Hyuk;Yoon, Hong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.265-276
    • /
    • 2018
  • Observation and data analysis techniques have been developed for observational blind areas in the lower atmosphere that are difficult to be monitored with fixed equipment on the ground. The vertical data of temperature and relative humidity are remotely collected by the UHF radiosonde installed on UAV and compared with the data measured in the 10 m weather tower. From the validated vertical profile, extrapolated surface temperature and the bulk transfer method were used to estimate the sensible heat flux depending on the atmospheric stability. Compared with the sensible heat flux measured by the 3-dimensional ultrasonic anemometer on the ground, the error of the sensible heat flux estimated was 23% that is less than the range of 30% allowed in the remote sensing. Estimated atmospheric boundary layer height from UAV sensible heat fluxes can provide useful data for air pollution diffusion models in real time and economically.

comparison of Numercal Methods for Obtaining 2-D Impurity Profile in Semiconductor (반도체 내에서의 2차원 불순물 분포를 얻기 위한 수치해법의 비교)

  • Yang, Yeong-Il;Gyeong, Jong-Min;O, Hyeong-Cheol
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.3
    • /
    • pp.95-102
    • /
    • 1985
  • An efficient numerical scheme for assessing the two-dimensional diffusion problem for modelling impurity profile in semiconductor is described. 4 unique combination of ADI (Al-ternating Direction Bmplicit) method and Gauss Elimination has resulted in a reduction of CPU time for most diffusion processes by a factor of 3, compared to other iteration schemes such as SOR (Successive Over-Relaxation) or Stone's iterative method without additional storage re-quirement. Various numerical schemes were compared for 2-D as well as 1-0 diffusion profile in terms of their CPU time while retaining the magnitude of relative error within 0.001%. good agree-ment between 1-D and 2-D simulation profile as well as between 1-D simulation profile and experiment has been obtained.

  • PDF

Determination of Glucose Using Enzyme Immobilized Membrane (효소 고정화 막을 이용한 Glucose의 정량)

  • Kim, Im Ok;Kwak, Kyeong Do;Ha, Youn Shick;Kwon, Hyo Shik;Seo, Moo Lyong
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.3
    • /
    • pp.264-270
    • /
    • 1999
  • Enzyme electrodes for amperometric measurement of glucose were prepared by immobilization of glucose oxidase on an Immobilon-AV Affinity membrane and attachement to a Pt electrodes. The electrochemical oxidation of Hz02 was monitored at +0.8V vs. Ag/AgCl. Response was linear from 0.2 mM to 20mM. The detection limit was 10m3 mM. Response time, the optimum pH and life time of enzyme immobilized membrane was 12 seconds, pH 5.5(CH3COONaJCH3COOH) and about 27 days, respectively. When the enzyme electrode was applied for the determinaion of glucose with amperometric method, other physiolosical materials have not interfered. Also, we compared the result with that from AOAC(Association of Offical Analytical Chemists) method, measuring the glucose in sweet potato. The relative error was 0.1%.

  • PDF