• Title/Summary/Keyword: relative comparison density

Search Result 98, Processing Time 0.022 seconds

Comparison of Behaviour of Straight and Curved Mechanically Stabilized Earth Walls from Numerical Analysis Results (수치해석을 통한 보강토옹벽 직선부와 곡선부의 거동 특성)

  • Jung, Hyuk-Sang
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.4
    • /
    • pp.83-92
    • /
    • 2017
  • This paper deals with numerical analysis of behavior of curved mechanically stabilized earth(MSE) walls with geosynthetics reinforcement. Unlike typical concrete retaining walls, MSE wall enables securing stability of higher walls without being constrained by backfill height and is currently and widely used to create spaces for industrial and residential complexes. The design of MSE walls is carried out by checking external stability, similarly to the external checks of conventional retaining wall. In addition, internal stability check is mandatory. Typical stability check based on numerical analysis is done assuming 2-dimensional condition (plane strain condition). However, according to the former studies of 3-dimensional MSE wall, the most weakest part of a curved geosynthetic MSE wall is reported as the convex location, which is also identified from the studies of the laboratory model tests and field monitoring. In order to understand the behaviour of the convex location of the MSE wall, 2-dimensional analysis clearly reveals its limitation. Furthermore, laboratory model tests and field monitoring also have restriction in recognizing their behaviour and failure mechanism. In this study, 3-dimensional numerical analysis was performed to figure out the behaviour of the curved part of the geosynthetic reinforced wall, and the results of the straight-line and curved part in the numerical analysis were compared and analysed. In addition, the behaviour characteristics at each condition were compared by considering the overburden load and relative density of backfill.

Characteristics of Nitro-nutrients and Phytoplankton Dynamics in the Yeongsan River after Weir Construction (보 건설 이후 영산강 보 구간에서의 질소계열 영양염류 및 식물플랑크톤 동태)

  • Seo, Kyung-Ae;Na, Jeong-Eun;Ryu, Hui-Seong;Kim, Kyunghyun
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.4
    • /
    • pp.423-430
    • /
    • 2018
  • Insomuch as it is important to manage water quality, from the perspective of water management, it is essential to understand the effect of the weirs on water quality and phytoplankton dynamics in various regions. The purpose of this study is to investigate the characteristics of nitro-nutrients, as well as occurrences and succession patterns of phytoplankton, in the river sections of the two weirs in the Yeongsan River for the five years (from 2012 to 2016) after the weir construction. In respect to this data, the average water temperature measured at the representative point in the section of the Seungchon Weir ($17.1^{\circ}C$) was higher than that of the Juksan Weir ($16.6^{\circ}C$) by comparison. By way of an analysis of this data, it was found that the water quality variables such as, organic matter, nitrogen nutrients and phosphorus nutrients were improved gradually during the period, but the degree of the improvement differs as noted and measured between the weirs. Under the circumstances, it is especially noted that the $NH_3-N$ concentration was higher for the point of the Seungchon Weir (2.204 mg/L) than that of the Juksan Weir (1.157 mg/L). This indicates that effluent as seen from sewage treatment plants and hydrological feature near the densely population area, could be the main cause for the incidence of water pollution in the upstream section of the Seungchon Weir. Additionally, the phytoplankton analysis showed that a relative abundance of diatoms and green algae were 56.9 % and 25.8 % respectively. However, it is noted that the cyanobacteria was measured lower as 10.7 %. Also, in the study sites cell density and occurrence frequency of cyanobacteria were relatively lower than compared to the same measurements noted in other rivers.

Evaluation of Lateral Pile Behavior under Cyclic Loading by Centrifuge Tests (원심모형 실험을 이용한 반복하중을 받는 모노파일 거동 평가)

  • Lee, Myungjae;Yoo, Mintaek;Park, Jeongjun;Min, Kyungchan
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.6
    • /
    • pp.39-48
    • /
    • 2019
  • This study investigated the lateral behavior of monopile embedded in the dry sand through cyclic lateral loading test using a centrifuge test. The sand sample for the experiment was the dry Jumunjin standard sand at 80% relative density and the friction angle of $38^{\circ}$. In the experimental procedure, firstly, it was determined the static lateral bearing capacity by performing the static lateral loading test to decide the cyclic load. This derived static lateral bearing capacity values of 30%, 50%, 80%, 120% were determined as the cyclic lateral load, and the number of cycle was performed 100 times. Through the results, the experiment cyclic p-y curve was calculated, and the cyclic p-y backbone curve by depth was derived using the derived maximum soil resistance point by the load. The initial slope at the same depth was underestimated than API (1987) p-y curves, and the ultimate soil resistance was overestimated than API (1987) p-y curves. In addition, the result of the comparison with the suggested dynamic p-y curve was that the suggested dynamic p-y curve was overestimated than the cyclic p-y backbone curve on the initial slope and soil resistance at the same depth. It is considered that the p-y curve should be applied differently depending on the loading conditions of the pile.

A study on the evaluation method and reinforcement effect of face bolt for the stability of a tunnel face by a three dimensional numerical analysis (터널막장안정 평가기법 및 막장볼트의 보강효과에 관한 수치해석적 연구)

  • Kim, Sung-ryul;Yoon, Ji-Sun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.1
    • /
    • pp.11-22
    • /
    • 2009
  • Tunnel excavation with several sections and appropriate auxiliary measures such as face bolt and pre-grouting are widely used in case of weak and less rigid ground for the stability of a tunnel face during excavation. This papers first described the evaluation methods proposed in technical literature to maintain the tunnel face stable, and then studied by FEM analysis whether face reinforcement is need in what degree of ground deformation and strength features for the stability of a tunnel face when excavating by full excavation with sub-bench. Lastly, a three dimensional FEM analysis was performed to study how the tunnel face itself and the ground around the tunnel behave depending on different bolt layouts, length of bolts, number of bolts. There were relative differences in comparison of results on the stability of a tunnel face by a theoretical evaluation methods and FEM analysis, but the same in reinforced effect of face. It was found that the stability of a tunnel face can be obtained with face bolt installed longer than 1.0D (tunnel width), bolt density of about 1 bolt per every $1.5\;m^2$ (layout of grid type), and reinforcement area of $120^{\circ}$ arch area of upper section.

Comparison between the method of the measurement 25 Vitamin D3 (25 Vitamin D3 측정에 있어서 화학발광미세입자 측정법과 화학발광면역 측정법 간의 비교 및 고찰)

  • Kim, dae-won;Lee, jung-hee;Jung, an-na;Seo, so-yoen
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.112-114
    • /
    • 2015
  • Purpose Vitamin D to Anti- Rickets both steroid compounds showing activity, By acting on bone tissue secretary and the key to maintain serum Ca homeostasis. The blood level of vitamin D is the largest in D3 that the concentration of the metabolite is reflected in the holding state of vitamin D in vivo. Sunlight to change the 7-dehydrocholesterol in the skin and through the skin to D3, In the liver in combination with the D2 and D3 D4 changes. The Radioimmunoassay(RIA) method is measuring the D 3, the sensitivity can be measured also difficult trace substance to measure the normal test because it is very sensitive, but recently, a check is possible, for the Total D3 in Chemimicroparticle immunoassay(CMIA) or Chemiluminescent immunoassay(CLIA) measuring using microparticle RIA and CMIA(Architect i2000SR) / use the CLIA(DXI-800) method to compare and evaluate the correlation between the tests in the same test items. Materials and Methods Commissioned from January 2014 to March 2015 patients were enrolled in a total of 273 people. 29 out of 273 people conducted by RIA were compared with CMIA, 244 patients were compared with CLIA. Using reagents and equipment were used RIA(Diasource), CMIA(Architect i2000SR, Abbott Diagnostics) / CLIA( Unicel DXi-800, Beckman coulter). Results Correlation of the RIA and CLIA was a R2 = 0.1844 (y = 0.7303x + 3.9005), and the correlation of RIA CMIA is R2 = 0.2762 (y = 0.8862x + 4.56) respectively. (According to statistics, during the same period RIA is Deficiency 4.31%, Insufficiency 90.53%, Sufficiency 5.16%, was Excess 0%, CLIA / CMIA is Deficiency 17.02%, Insufficiency 75.91%, Sufficiency 7.03%, indicating the distribution of 0.03 % Excess) Conclusion Serum vitamin D and parathyroid hormone that show an inverse relationship, the level above which are not parathyroid hormone and vitamin D reduced the increase. The density is different for each study, at most 20 is reported to be the maximum between 30 ng / ml. In Korea it requires a proposed standard of vitamin D deficiency, reference to the WHO lack the case more than 10ng/ml, 20ng/ml and defined by the lack of, if not more than, the IOM, but looking at 12ng/ml or less to the normal to lack, at least 20ng/ml, the reference do not match the deficit under 20ng/ml, 21-29ng/ml relative lack between, was also defined as a sufficient condition for more than 30ng/ml. Although not statistically is between RIA and CLIA two ways to vitamin D levels change according to season match, when seasonally seen in summer as commonly known (April to September), winter (October to March) relative to the increase measured than it was found. Finally, the study on the correlation between the two methods have been expected to result in a consistent and apply the same view high reference value on the graph is difficult. However, there may be differences between the test equipment and methods, and could be especially the case of RIA method using an organic solvent is difficult to compare different methods and correlated view similar trend in vitamin D deficiency and quarterly aspect ratio.

  • PDF

Effects of Some Environmental Factors on Japanese Yew (Taxus cuspidata Sieb. et Zucc.) (몇 발근환경인자(發根環境因子)가 주목삽수(揷穗) 발근(發根)에 미치는 효과(効果))

  • Kim, Chang Ho;Nam, Jung Chil
    • Journal of Korean Society of Forest Science
    • /
    • v.70 no.1
    • /
    • pp.1-6
    • /
    • 1985
  • The purpose of this experiment lies in finding the most appropriate cutting condition of Taxus cuspidata Sieb. et Zucc. which has been considered valuable tree species in gardening. Statistical analysis was focused on the comparison of the average ratios of rooting between greenhouses and fields, based on the observation rooted autogenis. To conduct this survey, hardwood cutting of Taxus cuspidata Sieb. et Zucc. were performed at both places of experiment above on April 20, 1982 with rooting results calculated on October 31, 1982. After formation of cuttings, it was soaked in IBA 200 ppm for 12 hours and than put in a bed. A summary of the result is presented as follows; 1) Cutting at the greenhouse showed higher average rate of rooting than at fields. Same tendency was found regardless of the differences in treatment. 2) It was clear that IBA-treatment contributed remarkably to causing higher average rooting rate. As an evidence, when twenty centimeter cuttings were inserted sandy media, IBA-treated area resulted in eighty six percent of average rooting rate, as compared with only twenty three percent in nontreatment case. In case of field cutting, IBA-treatment brought about fifty three percent of rooting in comparison with eleven percent nontreatment. 3) When sandy soil, loam and brown soil were separately used as cutting media, the highest rooting rate was found in case of sandy soil, without any difference between the two experimental places above. 4) As a result of the analysis to seek the impact of the length of cuttings on rooting, the range of length form fifteen to twenty centimeter was apparently most appropriate. It was also found that the rate of rooting declined beyond twenty five centimeter. 5) Two kinds of rooting pattern were observed. One was the case that callus cell lump was created on the lower cut side of cuttings. Importantly, root radical were formed inside the lump to influence the germination of root system. The other relates to the case that adventitious root which look like lateral roots appeared at the stem region. In abstract, first, sandy soil was effectively recommended in case of hardwood cutting in April. Second, the most appropriate length of cuttings ranged between fifteen and twenty centimeters. Third, high density IBA treatment was clearly effective. Forth, for proper environmental management, both pre-disinfection of sail by sterilizer and maintenance of high relative humidity were essentially required.

  • PDF

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF