• Title/Summary/Keyword: relative capacity

Search Result 790, Processing Time 0.027 seconds

Assessment of fishing power and fishing capacity of the snow crab (Chionoecetes opilio) gillnet fishery in the East Sea (동해안 대게 자망어업의 어획 성능 및 어획 능력 평가)

  • Lee, Kyoung-Hoon;Kim, Pyung-Kwan;Kim, Do-Hoon;An, Heui-Chun;Lee, Chun-Woo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.1
    • /
    • pp.29-39
    • /
    • 2012
  • Currently, environment-friendly and sustainable fisheries are one of the major issues among fisheries authorities. A variety of alternative management policies and projects are going on to enhance fisheries management systems and fishery resources such as a TAC management program and a VDS (Vessel Day Scheme) management scheme for distant water fishing nations in Western and Central Pacific Fisheries Commission (WCPFC) convention area. These kinds of efforts among fisheries management authorities are aimed at limiting fishing capacity or fishing power. In terms of fisheries management, Fishing capacity and fishing power have increased the importance of the impact on a fishery and level of the resources. Increased fishing capacity and fishing power have caused not only depletion of fisheries resource, but also additional fishing cost. therefore, there is a clear need for authorities to manage fishing capacity and fishing power. It is also help ensure the conservation and sustainability of the fishery resources. Because of lack of data, absolute fishing power is difficulty to measure. The notion of relative fishing power is frequently used. In this study, relative fishing power was assessed using Mastuda (1991) method for fishing power index. The raw data for assessment was based on fishermen's logbook data from sampled fishing vessels in coastal snow crab gillnet fishery. Data Envelopment Analysis (DEA) method was used to assess fishing capacity. DEA is a linear programming methodology to measure the efficiency of a set of entities called Decision-Making Units (DMUs). It was recommended by FAO for assessing capacity in fisheries.

A Study on the Bearing Capacity of Rammed Aggregate Pier as the Intermediate Foundations (중간기초개념으로서 짧은 쇄석다짐말뚝의 지지력 특성에 관한 연구)

  • CHUN BYUNG-SIK;KIM KYUNG-MIN;KIM JUN-HO
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.247-252
    • /
    • 2004
  • To secure stability and availability of Rammed Aggregate Pier method as the foundation of a structure, the bearing capacity and failure behavior characteristics was studied through soil laboratory tests in a model ground. In this study, soil laboratory tests use carried out to find the applicability of RAP method as the foundation of a structure. And bearing capacity and the failure mechanism of RAP method was studied according to relative density($60\%,\;70\%,\;90\%$), diameter(45mm, 60mm, 70mm) of each pier ana depth(5cm, l0cm, 15cm, 20cm, 25cm, 30cm). Earth pressure cell is set up approach RAP and 1.0D space at RAP center. Bearing acpacity and the failure mechanism of RAP is investigated by load test As a result, bulging failure was happened in $5\~10cm\;(1.0D\~2.00)$ depth which the maximum lateral earth pressure is acting. Especially, diameter changing of RAP are in inverse proportion to the relative density and the lateral stress is very much influenced by the lateral earth pressure in every layer and tends to decrease according to depth.

  • PDF

Effects of Soil Conditions on the Behavior of Open -Ended Steel Pipe Pile (지반조건의 변화가 개단강관말뚝의 거동에 미치는 영향)

  • Baek, Gyu-Ho;Lee, Jong-Seop;Lee, Seung-Rae
    • Geotechnical Engineering
    • /
    • v.9 no.3
    • /
    • pp.23-34
    • /
    • 1993
  • Model pile teats, using large calibration chamber in which the stress state and the relative density can be controlled, were performed in order to study on the effect of soil condition on the behavior of open-ended steel pipe pile. The model pipe pile was made up of two pipes to separately measure each component of bearing capacity of open -ended steel pipe pile. According to the tests results, pile plugging and driving resistance of the pile installed in sand were primarily dependent on the horizontal stress and the relative density. Plug bearing capacity, outside skin fricition and total bearing capacity were also mainly dependent on the horizontal stress and relative density. Moreover, the ratio of the horizontal stress acting on the outside wall of open -ended pipe pile after installation to the original horizontal stress was not nearly affected by original value of horizontal stress. It is bigger than one in the case of dense deposit, equal to one for medium deposit, and smaller than one for very loose deposit. It seems to be mainly dependent on the relative density for a given soil.

  • PDF

Bearing of Strip Foundation on Geogrid-Reinforced Sand With Embedment Depth (기초의 근입깊이를 고려한 지오그리드 보강 사질토지반의 지지력 평가)

  • 신은철;신동훈;오영인
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.233-240
    • /
    • 1999
  • The laboratory tests on geogrid-reinforced sand were conducted with considering embedment effect. The relative densities of sand are 60% and 80%, respectively. The embedment depths of foundation were varied as D$\_$f/B=0, 0.5, 1.0. Based on the model test results, (u/B)$\_$cr/, BCR$\_$u/, and (b/B)$\_$cr/, were determined. The optimum depth of reinforcement was determined. The embedment depth of foundation is greatly contributed on the bearing capacity of geogrid-reinforced sand.

  • PDF

Experimental Study on Cooling Performance of A/C applied Fin-tube and PF Heat Exchangers (핀-관, 평행류 열교환기를 적용한 공조기의 냉방성능 실험연구)

  • Kwon, Young-Chul;Park, Yoon-Chang;Kwon, Jeong-Tae;Park, Gyung-Man
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1789-1794
    • /
    • 2009
  • In the present study, the cooling performance characteristics on environment changes of A/C applied fin-tube and PF heat exchangers were experimentally investigated. Capacity and COP on an air velocity, an indoor/outdoor temperature and an indoor/outdoor relative humidity were obtained. Fin types of PF heat exchanger were a triangler and squarer form. The experimental data for the three kinds of heat exchangers were measured using the air-enthalpy calorimeter. Performance of PF A/C was more excellent than that of a fin-tube A/C. Also, the performance of PF-2 A/C with the squarer fin was more excellent than that of PF-1 A/C with the triangler fin. As the air velocity, the indoor temperature and the indoor relative humidity increase, capacity and COP increase. And as outdoor temperature increases, capacity and COP decrease. But, the performance change on the outdoor relative humidity was insignificant.

A Study on the Adsorption Properties of Diisopropyl Methyl Phosphonate on Chromium-Based Metal-Organic Frameworks Using Acetic Acid as a Modulator (아세트산을 조절인자로 제작한 크롬 기반 금속유기골격체의 diisopropyl methyl phosphonate 흡착 특성 연구)

  • Sangjo Jeong
    • Applied Chemistry for Engineering
    • /
    • v.34 no.6
    • /
    • pp.596-602
    • /
    • 2023
  • Chromium-based metal-organic frameworks (MIL-101(Cr)) were synthesized, and their potential use as a filling material for gas masks or protective clothing was assessed through adsorption experiments using diisopropyl methyl phosphate (DIMP) as a simulant for chemical warfare agents. MIL-101(Cr) was prepared using acetic acid (MIL-101(Cr)-A) and sodium hydroxide (MIL-101(Cr)-N) as modulators. The use of acetic acid as a modulator resulted in a larger specific surface area and a higher DIMP adsorption capacity. MIL-101(Cr)-A absorbed approximately 160% of its own weight of moisture when exposed to an environment with a relative humidity of 90% for 10 days, surpassing other adsorbents such as activated carbon. The DIMP adsorption capacity of MIL-101(Cr)-A decreased to about 40% of its initial adsorption capacity after 24 hours of exposure to an environment with a relative humidity of 90%. However, this capacity is still higher compared to that of activated carbon used in commercial gas masks, suggesting a high potential for future use as a filling material for gas masks or protective clothing.

Lateral capacity of piles in layered soil: a simple approach

  • Mandal, Bikash;Roy, Rana;Dutta, Sekhar Chandra
    • Structural Engineering and Mechanics
    • /
    • v.44 no.5
    • /
    • pp.571-584
    • /
    • 2012
  • Appropriate assessment of lateral capacity of pile foundation is known to be a complex problem involving soil-structure interaction. Having reviewed the available methods in brief, relative paucity of simple and rational technique to evaluate lateral capacity of pile in layered soil is identified. In this context, two efficient approaches for the assessment of lateral capacity of short pile embedded in bi-layer cohesive deposit is developed. It is presumed that the allowable lateral capacity of short pile is generally dictated by the permissible lateral displacement within which pile-soil system may be assumed to be elastic. The applicability of the scheme, depicted through illustration, is believed to be of ample help at least for practical purpose.

Estimation of Bearing Capacity for Open-Ended Pile Considering Soil Plugging (폐색정도를 고려한 개단말뚝의 지지력 산정)

  • 백규호
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.397-404
    • /
    • 2002
  • The bearing capacity of open-ended piles is affected by the degree of soil plugging, which is quantified by the IFR. There is not at present a design criterion for open-ended piles that explicitly considers the effect of IFR on pile load capacity In order to investigate this effect, model pile load tests using a calibration chamber were conducted on instrumented open-ended piles. The results of these tests show that the IFR increases with increasing relative density and increasing horizontal stress of soils. The unit base and shaft resistances decrease with increasing IFR. Based on the results of the model pile tests, new empirical relations for base load capacity and shaft load capacity of open-ended piles are proposed. In order to check the accuracy of predictions made with the proposed equations, the equations were applied to the full-scale pile load test preformed in this study, Based on the comparisons with the pile load test results, the proposed equations appear to produce satisfactory predictions.

  • PDF

Reinforcement layout design for deep beam based on BESO of multi-level reinforcement diameter under discrete model

  • Zhang, Hu-zhi;Luo, Peng;Yuan, Jian;Huang, Yao-sen;Liu, Jia-dong
    • Structural Engineering and Mechanics
    • /
    • v.84 no.4
    • /
    • pp.547-560
    • /
    • 2022
  • By presetting various reinforcement diameters in topology optimization with the discrete model finite element analysis, an algorithm of bidirectional evolutionary structural optimization of multi-level reinforcement diameter is presented to obtain the optimal reinforcement topologies which describe the degree of stress of different parts. The results of a comparative study on different reinforcement feasible domain demonstrate that the more angle types of reinforcement are arranged in the initial domain, the higher utilization rate of reinforcement of the optimal topology becomes. According to the nonlinear finite element analysis of some deep beam examples, the ones designed with the optimization results have a certain advantage in ultimate bearing capacity, although their failure modes are greatly affected by the reinforcement feasible domain. Furthermore, the bearing capacity can be improved when constructional reinforcements are added in the subsequent design. However the adding would change the relative magnitude of the bearing capacity between the normal and inclined section, or the relative magnitude between the flexural and shear capacity within the inclined section, which affects the failure modes of components. Meanwhile, the adding would reduce the deformation capacity of the components as well. It is suggested that the inclined reinforcement and the constructional reinforcement should be added properly to ensure a desired ductile failure mode for components.