• 제목/요약/키워드: reinforcing bar anchor

검색결과 12건 처리시간 0.028초

GFRP Rebar의 인장특성 및 시험법에 관한 연구 (Tensile Properties and Testing Method for Glass Fiber Reinforced Polymer Reinforcing bar)

  • 박지선;유영찬;박영환;최기선;유영준;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.172-175
    • /
    • 2004
  • This study is to investigate the tensile properties of glass fiber reinforced polymer(GFRP) reinforcing bars with various kinds of anchor systems experimentally. Three types of anchor systems were examined: resin sleeve anchor adopted by CSA Standard, metal overlay anchor by ASTM Standards and wedge anchor normally used in prestressing tendons. Also, three different types of GFRP bars with different surface deformations were tested in this study. All test procedures including specimens preparation, test apparatus and measuring devices were made according to the recommendations of CSA Standard S806-02. From the test results, it was found that the highest tensile strength of GFRP bar was developed by resin sleeve anchor, and tensile strength of GFRP bar with CSA anchor system is $10\%$ higher than that with ASTM anchor system in the case of sand-coated GFRP bar.

  • PDF

타격식 앵커를 이용한 하이브리드 섬유보강재의 보강특성 (Reinforcing Characteristics of Hybrid Fiber Composite Fixed with Impact Anchor)

  • 하상수;최동욱;이진용;김동완
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.453-456
    • /
    • 2008
  • 섬유보강재는 부식에 대한 저항성이 높고, 고강도이며, 또한 강도에 대한 중량비(섬유보강재의 중량은 보강철근의 약 1/4정도)가 매우 낮아서 구조물 및 내하력이 저하된 콘크리트구조물의 보강에 따른 추가적인 중량의 증가 없이 보강을 할 수 있는 장점을 가지고 있다. 그러나 섬유보강재는 하중을 가하면, 최대 응력점까지 응력이 선형적으로 증가하다가 파괴되는 취성적 성질을 가지고 있다. 이러한 단점을 보완하기 위해 여러 섬유를 혼합하여 하이브리드화된 섬유보강재를 개발하였다. 개발된 하이브리드 섬유보강재는 유리섬유와 탄소섬유를 혼합하여 바 형태로 제작했으며, 유리섬유에 대한 탄소섬유의 체적비는 약 9 : 1로 구성이 된다. 하이브리드 섬유보강재를 타격식 앵커를 사용하여 시험체를 보수한 다음 인발 및 휨 시험을 실시하여 정착앵커의 수에 대한 시험체의 거동을 분석하였다. 본 연구에서는 타격식 앵커를 이용한 하이브리드 섬유보강재로 보강된 구조물의 보강특성을 알아보는데 목적이 있다.

  • PDF

Head 플레이트 상세에 따른 Headed Bars의 인발거동에 관한 연구 (Pull-out Behaviors of Headed Bars with Different Details of Head Plates)

  • 박현규;윤영수;류영섭;이만섭
    • 한국방재학회 논문집
    • /
    • 제2권2호
    • /
    • pp.95-104
    • /
    • 2002
  • 이 논문은 콘크리트 콘 파괴에 의해 지배될 때의 인장력의 예측과 Headed bar의 인발 파괴 양상을 보여준다. 1개의 다른 플레이트 형상과 세가지의 서로 다른 용접 방법에 따라 시험이 이루어졌다. 시험의 변수는 Headed plate에 연결된 철근의 직경(16mm, 19mm, 22mm), 형상(원형, 직사각형, 정사각형)과 head plate의 차원(면적, 두께), 철근과 head plate와의 연결을 위한 용접 방법(일반용접, 마찰용접)이다. Headed bar는 ASTM 970-98에 기초한 모양과 두께를 가진 다른 단면적으로 제조되었으며 콘크리트의 부착 길이는 CSA 23.3-94에 의거하여 산정되었다. 정적 인장하중이 적용되었으며 시험 인발 성능은 ACI-349와 CCD 방법과 같은 현재의 설계방법에 의해 산출된 값과 비교하였다. 실험결과와 기존식을 비교하면 Headed bar가 앵커와 달리 넓은 플레이트 면적과 이형철근으로 인해 기준식에 비해 높은 강도와 큰 파괴 반경을 나타내었다.

Direct Shear Test of Retrofit Anchors Using Deformed Reinforcement and Adhesive

  • Choi, Dong-Uk;Kim, Yong-Gon
    • KCI Concrete Journal
    • /
    • 제12권1호
    • /
    • pp.91-99
    • /
    • 2000
  • A new type of retrof=t anchor bolt that uses deformed reinforcing bars and a commercial adhesive was developed and then an experimental study was carried out to determine the behavior of the anchors in direct shear. The steel-to-concl몫ete interface was tested. Plain concrete slabs with about 20-MPa compressive strength were used for 23 direct shear tests performed Test variables were anchor diameters (D16, D22. and D29) and edge effect. Three different shear tests were completed: simple shear, edge shear where anchors were pulled against the concrete core, and edge shear where anchors were pushed against the concrete cover In the simple and the edge shear tests where the anchors were pulled against the core, the theoretical dowel strength determined by (equation omitted) was achieved but with relatively large displacements. The shear resistances increased with the increasing displacements. In the edge shear test where the anchors were pushrd against the cover, the peak shear strengths signif=cantly lower than the theoretical dowel strength were determined due to cracks developed in concrete when the edge distance was 80 mm. The peak strengths were about 50% of the dowel strength for Dl6 bar. and about 25% or less of the dowel strength for D22 and D29 bars. Test results revealed that the edge shear where the anchor was pushed against the cover controled.

  • PDF

스터럽 보강 선설치 앵커의 정적 전단하중에 대한 저항 강도 (Static Shear Strength of Cast-in Anchors with Stirrup Reinforcement)

  • 박용명;조성훈;김태형;강충현;김재봉
    • 한국강구조학회 논문집
    • /
    • 제28권1호
    • /
    • pp.1-12
    • /
    • 2016
  • 본 연구에서는 스터럽 보강 선설치 앵커의 정적 전단하중에 대한 저항강도 평가를 위한 실험 연구를 수행하였다. 실험변수로는 전면지압철근 유무와 콘크리트 균열 유무로 설정하였다. 앵커는 M36, 연단거리는 180mm로 하였다. 모든 철근은 HD-10 철근을 사용하고 스터럽의 간격은 100mm로 하였다. 실험으로부터 전면지압철근을 설치한 경우 스터럽 저항강도는 16% 증가하였다. 한편 균열 콘크리트에서의 저항강도는 비균열 콘크리트에 비해 5% 감소에 불과하였다. 실험 결과로부터 ACI 318 및 ETAG 001 기준은 스터럽의 저항강도를 안전측으로 평가하였으며, 적절한 강도 평가 방안을 제안하였다. 마지막으로 스터럽 보강 시 앵커 본체의 파괴강도에 대한 고찰을 제시하였다.

아치형 해저 케이블 보호 구조물의 앵커 충돌 수치 시뮬레이션 (Numerical Simulation of Arch-type Submarine Cable Protector under Anchor Collision)

  • 우진호;나원배;김헌태
    • 한국해양공학회지
    • /
    • 제23권1호
    • /
    • pp.96-103
    • /
    • 2009
  • In 2006, Jeju Island in South Korea experienced a crisis, no electricity for three hours anywhere in the entire island. This incident was caused by a domino effect that occurred after one of the submarine power cables connecting the island to Haenam, a coastal city on the mainland, was damaged by an external load, probably from a ship anchor or a steel pile being used in marine farming. This study presents a collision analysis of a new submarine power cable protector called arch type reinforced concrete. For the analysis, a dynamic finite element program, ANSYS AUTODYN, was used to examine the displacement and stress of the submarine power cable protector using different material models (RHT concrete model, Mohr.Coulomb concrete model). In addition, two reinforcing bar spacings, 75 mm and 150 mm, were considered. From the analyses, the effects of the parameters (concrete model and spacing) on the results (displacement and stress) were analyzed, and the relations between the damage and parameters were found.

A new base plate system using deformed reinforcing bars for concrete filled tubular column

  • Park, Yong-Myung;Hwang, Won-Sup;Yoon, Tae-Yang;Hwang, Min-Oh
    • Steel and Composite Structures
    • /
    • 제5권5호
    • /
    • pp.375-394
    • /
    • 2005
  • An experimental study was conducted to develop a new base plate anchorage system for concrete filled tubular column under an axial load and a moment. The column was connected to a concrete foundation using ordinary deformed reinforcing bars that are installed at the inside and outside of the column. In order to investigate the moment resisting capacity of the system, horizontal cyclic loads are applied until the ultimate condition is reached with the axial load held constant. To derive a design method for moment resisting capacity, the reinforced concrete section approach was investigated with the assumption of strain compatibility. The results by this approach agreeded well with those of experiments when the bearing pressure of confined concrete and tangent modulus of steel bars are assumed appropriately. Also, it was found that the column interaction curve can be used to predict the yield strength of the base plate system.

CFRP로 보강된 RC보의 부착상세에 따른 보강효과 (Strengthening Effects of R.C. Beams using Externally attached CFRP Composites with Bond[ Details)

  • 박종섭;박영환;조정래;유영준;정우태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.591-596
    • /
    • 2003
  • Many studies have dealt with strengthening by epoxy-bonded CFRP(Carbon Fiber Reinforced Polymer) composites. However, the effects of various influencing factors have not been clarified on the behavior of strengthened RC beams. This study was performed to verify the effects of strengthening due to various bond details of externally attached CFRP Composites. In this study, major test parameters include the bond type and the anchor type. The deflections, failure load, strain of reinforcing bar, concrete and CFRP are measured at each loading step. The failure mode and debonding loads(ultimate loads) are analysed from these measured data. According to the test results, all specimens are failed by intermediate flexural crack induced interfacial debonding.

  • PDF

강판 휨보강된 철근 콘크리트보의 구조적 거동 (Structural Behavior of RC Beam Strengthened with Steel Plate)

  • 오병환;강동욱;조재열;채성태;이명규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.598-604
    • /
    • 1997
  • In recent years, strengthening by epoxy-bonded steel plates, carbon fiber sheets, aramid fiber sheets and so on, is spotlighted. Among them, the method using steel plates is most widely applied. Most studies have dealt with strengthening by epoxy-bonded steel plates. However the actual behavior of strengthened RC beams are not well established. Particularly, the studies on the separation load thar affects failure load of the beam are relatively insufficient. In this study, test parameters are the magnitude of pre-load, plate length, plate thickness, existence and spacing of anchor bolt, the number of plate layer and the height of side strengthening, 17reinforced concrete beams are strengthened by steel plates according to test parameters. Deflection, failure load, strains of reinforcing bar, concrete and plate are measured from tests(4 points loading). The failure mode, and separation load are analyzed from these measured data. The difference between Robert's theory and test results is discussed, and the prediction equation for separation load in the case of rip off is proposed.

  • PDF

사무소 건축물의 단열상황에 관한 조사연구 (Survey Research on Thermal Situation of Office Buildings)

  • 정의인;김봉주
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권3호
    • /
    • pp.145-152
    • /
    • 2013
  • 본 논문은 1990년대~2011년 시공 중이었던 건축물의 커튼월의 단열성을 평가하기 위하여 내외 표면 온도를 측정하여 부위별 온도 차이를 분석하였다. 유리면이나 단열층이 있는 표면보다 커튼월의 프레임 (멀리온 및 트랜섬)의 온도는 동절기 외부 평면의 경우 $6^{\circ}C{\sim}10^{\circ}C$ 정도 높게 나타났다. 또한, 같은 프레임에서도 앵커유닛이 있는 부위가 다른 프레임보다 $2^{\circ}C{\sim}3^{\circ}C$ 더 높게 나타나 보다 큰 열 손실이 일어나고 있는 것으로 나타났다.