• Title/Summary/Keyword: reinforcing bar

Search Result 493, Processing Time 0.033 seconds

Bond-Slip Effect in Analysis of RC Beams Using Layered Section Method (적층단면법을 토대로한 철근콘크리트 보 해석에서의 부착슬립효과)

  • Kwak-Hyo-Gyoung;Kim, Jin-Kook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.65-68
    • /
    • 2005
  • An analytical procedure to analyze reinforced concrete (RC) frame subject to cyclic as well as monotonic loadings is proposed on the basis of the layered section method. In contrast to the classical nonlinear approaches adopting the perfect bond assumption, the bond-slip effect along the reinforcing bar is quantified with the force equilibrium and compatibility condition at the post-cracking stage and its contribution is implemented into the reinforcing. The advantage of the proposed analytical procedure, therefore, will be on the consideration of the bond-slip effect while using the classical layered section method without additional consideration such as taking the double nodes. Through correlation studies between experimental data and analytical results, it is verified that the proposed analytical procedure can effectively simulate the cracking behavior of RC beams, columns and Frame accompanying the stiffness degradation caused by the bond-slip.

  • PDF

Evaluation of Rib Geometries of Reinforcing Bars Available in Korea, Japan and USA (국내외 이형철근의 마디 형태 및 부착강도 비교)

  • Soe, Dong-Min;Kim, Ki-Seong;Bong, Won-Young;Yang, Seung-Yul;Hong, Gi-Suop;Choi, Oan-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.278-281
    • /
    • 2006
  • The aims of this study are to investigate rib geometries of reinforcing bars commercially available in Korea, Japan and USA, and evaluate bond performance using beam-end test specimens. Measurement of rib geometries of the bars include nominal area, average distance of rib, height of rib and an angle of rib perpendicular to bar axis. The result of this study show that rib height of Korean reinforcement bars are much less than those of Japan and USA resulting in the lowest value of relative rib area. Average bond strength of Korean D25 deformed bars is known as 9 % less than that of bars produced in USA. Bond strength depends primarily on the relative rib area. Bond strength of the high relative rib area bars produced in USA show 18% higher than that of bars produced in Korea.

  • PDF

Effect of degree of corrosion on the mechanical properties of rebar (철근부식정도가 철근의 역학적 특성에 미치는 영향)

  • Cheong, Hai-Moon;Lee, Chan-Young;Ahn, Tas-Song;Tae, Sung-Ho;Lee, Han-Seung;Kang, In-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.257-260
    • /
    • 2006
  • This paper reports results of a study conducted to assess the effect of degree of corrosion of reinforcing steel bar on their mechanical properties. Reinforcing steel bars, 13mm in diameter, that were corroded by electrically accelerated corrosion method in concrete specimens were removed and tested in tension. Results indicated that the level of reinforcement corrosion influenced yield point, the tensile strength and elongation of steel bars.

  • PDF

Modified model of ultimate concrete compression strain (콘크리트의 극한변형률 수정모델)

  • Ko, Seong-Hyun;Lee, Jae-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.81-84
    • /
    • 2008
  • The purposes of this study are to verify a reasonable model of material characteristic and to propose a rational model of reinforcement characteristic considering monotonic and cyclic loading about manufactured reinforcing steel in Korea. Longitudinal reinforcements of the plastic hinge region were behaved tensile deformation and compressional deformation by direction of lateral loading. However Confinement steels were behaved only tensile deformation by lateral loading. Transverse steels were laid the state of tension in the lateral loading of time, and they were laid state that stress is zero when it was removed lateral load. The tests for cyclic tension loading were performed for test variable as yield strength and reinforcement bar sizes. It was estimated that the total strain energy per unit volume was 74 $MJ/m^3$. The modified ultimate concrete compression strain model was proposed based on experimental study of cyclic tension test for manufactured reinforcing steel in Korea.

  • PDF

Effect of Surface Condition and Corrosion-Induced Defect on Guided Wave Propagation in Reinforced Concrete

  • Na, Won-Bae;Kang, Dong-Baek
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.6 s.73
    • /
    • pp.1-6
    • /
    • 2006
  • Corrosion of reinforcing steel bars is a major concern for ocean engineers when reinforced concrete structures are exposed to marine environments. Evaluating the degree of corrosion and corrosion-induced defects is extremely necessary to pursue a proper retrofit or rehabilitation plan for reinforced concrete structures. A promising inspection should be carried out for the evaluation, otherwise the retrofit or rehabilitation process would be useless. Nowadays, ultrasonic guided wave-based inspection techniques become quite promising for the inspection, mainly because of their long-range propagation capability and their sensitivity to different types of defects or conditions. Evaluating haw the guided waves response to the different types of defects or conditions is quite challenging and important. This study shows how surface conditions of reinforcing bars and a corrosion-induced defect, separation, affect guided wave propagation in reinforced concrete. Experiments and associated signal analysis show the sensitivity of guided waves to the surface conditions, as well as the amounts of separation at the interface between. concrete and steel bar.

Cyclic behavior of connection between footing and concrete-infilled composite PHC pile

  • Bang, Jin-Wook;Hyun, Jung Hwan;Lee, Bang Yeon;Kim, Yun Yong
    • Structural Engineering and Mechanics
    • /
    • v.50 no.6
    • /
    • pp.741-754
    • /
    • 2014
  • The conventional PHC pile-footing connection is the weak part because the surface area and stiffness are sharply changed. The Composite PHC pile reinforced with the transverse shear reinforcing bars and infilled-concrete, hereafter ICP pile, has been developed for improving the flexural and shear performance. This paper investigates the cyclic behavior and performance of the ICP pile-footing connection. To investigate the behavior of the connection, one PHC and two ICP specimens were manufactured and then a series of cyclic loading tests were performed. From the test results, it was found that the ICP pile-footing connection exhibited higher cyclic behavior and connection performance compared to the conventional PHC pile-footing connection in terms of ductility ratio, stiffness degradation and energy dissipation capacity.

Properties of Adhesion Tension of Polymer Cement Slurry for Coated Reinforcing Bar (철근 도장용 폴리머 시멘트 슬러리의 부착 특성)

  • 김현기;이철웅;장성주;김완기;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.343-348
    • /
    • 2000
  • The purpose of this study is to clarify properties adhesive strength of polymer-cement slurry for coated reinforcing bars. The epoxy coating material is superior to performance of anti-corrosion but lately age adhesive strength between concrete raise to structural problems. However, polymer dispersion with excellent performance of elasticity and adhesion can solve this problems. From the test results. adhesion of steel with polymer cement slurry using St/BA emulsion is show excellent without concerned coating thickness, and polymer cement slurry using St/BA emulsion is show adhesion in tension 1.2~2.2MPa at polymer cement ratio 50% of more.

  • PDF

An Experimental Study on the Crack Pattern of Concrete by Corrosion of Steel Reinforcing (콘크리트의 균열발생 거동에 관한 실험적 연구)

  • Paik, Min-Su;Kim, Youn-Kyoung;Lee, Young-Do;Lim, Nam-Gi;Choi, Eung-Kyoo;Kim, Young-Hoi;Chung, Lan;Jung, Sang-jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.235-240
    • /
    • 1997
  • The purpose of this experiment is to verify processing crack direction and state by the corrosion of electrifying re-bar in the salt water. The result of this experiment is the fact that the first crack appear on the surface of water-because of supplying of oxygen and water. The crack processing is on a surface to be contacted by air and to bottom as mainly the vertical direction from a surface of water. The crack by corrosion of steel reinforcing is emerged by the inside of concrete rather than surface concrete.

  • PDF

Evaluate Anchorage Strength of High Relative Rib Area Bars Using Hook Test Specimens (갈고리 시험체를 이용한 높은마디면적 철근의 정착성능)

  • Seo Dong Min;Hong Gi Suop;Choi Dong Uk;Choi Oan Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.327-330
    • /
    • 2005
  • Bond failure of reinforcing bar generally take place by splitting of the concrete cover as bond force between concrete and reinforcing bars exceeds the confinement of the concrete cover and reinforcement. However, the confinement force in practice has a limitation. Thus, the only variable is the bearing area corresponding to the change of bond force. In this study, to the evaluate anchorage strength of high relative rib area bars, hook bond test specimens are tested and the results are discussed. Higher rib height bars when bars are confined showed higher anchorage strength than lower rib higher bars.

  • PDF

First Diagonal Cracking and Ultimate Shear of I-Shaped Reinforced Girders of Ultra High Performance Fiber Reinforced Concrete without Stirrup

  • Wu, Xiangguo;Han, Sang-Mook
    • International Journal of Concrete Structures and Materials
    • /
    • v.3 no.1
    • /
    • pp.47-56
    • /
    • 2009
  • The first diagonal cracking and ultimate shear load of reinforced girder made of ultra high performance fiber reinforced concrete (UHPFRC) were investigated in this paper. Eleven girders were tested in which eight girders failed in shear. A simplified formulation for the first diagonal cracking load was proposed. An analytical model to predict the ultimate shear load was formulated based on the two bounds theory. A fiber reinforcing parameter was constituted based on the random assumption of steel fiber uniform distribution. The predicted values were compared with the conventional predictions and the test results. The proposed equation can be used for the first cracking status analysis, while the proposed equations for computing the ultimate shear strength can be used for the ultimate failure status analysis, which can also be utilized for numerical limit analysis of reinforced UHPFRC girder. The established fiber reinforcing theoretical model can also be a reference for micro-mechanics analysis of UHPFRC.