• Title/Summary/Keyword: reinforced structures

Search Result 3,711, Processing Time 0.061 seconds

Creep Modelling of Reinforced Earth using Power Law-based Creep Models (Power Law 기반의 크리프 모델을 이용한 보강토 구조물의 크리프 모델링)

  • Kim, Jae-Wang;Kim, Sun-Bin;Yoo, Chung-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.164-178
    • /
    • 2009
  • The importance of long-term performance of reinforced earth structures has been gaining its attention as the use of reinforced earth structures as load supporting structures is increasing. When using reinforced earth structures as loading supporting structures the stability as well as serviceability requirements must be met. In that respect the time-dependent long term deformation characteristics should be well understood. In this study the applicability of power law-based creep models for modeling of creep deformation of the components of reinforced earth structures are examined.

  • PDF

Seismic response of RC frame structures strengthened by reinforced masonry infill panels

  • Massumi, Ali;Mahboubi, Behnam;Ameri, Mohammad Reza
    • Earthquakes and Structures
    • /
    • v.8 no.6
    • /
    • pp.1435-1452
    • /
    • 2015
  • The performance of masonry infilled frames during the past earthquakes shows that the infill panels play a major role as earthquake-resistant elements. Experimental observations regarding the influence of infill panels on increasing stiffness and strength of reinforced concrete structures reveal that such panels can be used in order to strengthen reinforced concrete frames. The present study examines the influence of infill panels on seismic behavior of RC frame structures. For this purpose, several low- and mid-rise RC frames (two-, four-, seven-, and ten story) were numerically investigated. Reinforced masonry infill panels were then placed within the frames and the models were subjected to several nonlinear incremental static and dynamic analyses. In order to determine the acceptance criteria and modeling parameters for frames as well as reinforced masonry panels, the Iranian Guideline for Seismic Rehabilitation of Existing Masonry Buildings (Issue No. 376), the Iranian Guideline for Seismic Rehabilitation of Existing Structures (Issue No. 360) and FEMA Guidelines (FEMA 273 and 356) were used. The results of analyses showed that the use of reinforced masonry infill panels in RC frame structures can have beneficial effects on structural performance. It was confirmed that the use of masonry infill panels results in an increment in strength and stiffness of the framed buildings, followed by a reduction in displacement demand for the structural systems.

A Study on the Safety of Reinforced Concrete Structures under Fatigue Load (피로 하중을 받는 철근콘크리트 구조물의 안전성에 관한 연구)

  • 채원규
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.2
    • /
    • pp.18-25
    • /
    • 1994
  • In this thesis, the fatigue tests were performed on a series of reinforced concrete to Investigate the variation of strength and the safety of reinforced concrete structures under fatigue load. The specimens were of the same rectangular cross-section, of effective height 24cm and width 30cm and their span was 330cm. The three point loading system is used in the fatigue tests. In these tests, the fracture mode of reinforced concrete structures under fatigue load, relationship between the repeated loading cycles and the mid-span displacement of the specimens were observed. According to the test results, the following fatigue behavior of reinforced concrete specimens were observed. By increasing of the number of repeated loading cycles, the mid-span displacement became greater, however the Incremental amounts of the displacement were reduced. It could be also known that the inelastic strain energy of the doubly reinforced rectangular beams was larger than that of the singly reinforced rectangular beams as increasing the number of repeated loading cycles. Compliance of reinforced concrete structures tended to be reduced as increasing the repeated loading cycles, and the compliance of the doubly reinforced rectangular beams was generally smaller than that of the singly reinforced rectangular beams. Based on the above investigation, it could be concluded that the doubly reinforced rectangular beams under fatigue load were more efficient to resist the brittle fracture than the singly reinforced rectangular beams.

  • PDF

Shear Strength of Reinforced Concrete Beams Strengthened by Fiber Reinforced Polymer (섬유보강 철근콘크리트 보의 전단강도 평가)

  • Hwang Hyun-Bok;Lee Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.401-404
    • /
    • 2004
  • In recent years, the use of fiber reinforced polymer (FRP) composites to repair or strengthen existing reinforced concrete (RC) structures is increasing In order to evaluate the shear strengths of RC structures strengthened by FRP composites, it is needed to understand the shear failure modes of these structures. This paper presents a rational equation to distinguish the shear fail modes of RC structures strengthened by FRP composites using the compatibility aided truss models.

  • PDF

Structural Performance Assessment of Damaged Reinforced Concrete Structures (손상된 철근콘크리트 구조물의 구조성능평가)

  • Kim, Tae-Hoon;Kim, Young-Jin
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.19-28
    • /
    • 2011
  • In this study, nonlinear finite element analysis procedures are presented for the structural performance assessment of damaged reinforced concrete structures. A computer program, named RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), for the analysis of reinforced concrete structures was used. Material nonlinearity is taken into account by comprising tensile, compressive and shear models of cracked concrete and a model of reinforcing steel. This paper defines a damage index based on the predicted inelastic behavior of reinforced concrete structures. The proposed numerical method for the structural performance of damaged reinforced concrete structures is verified by comparison with reliable experimental results.

Nonlinear Failure Analysis of Reinforced Concrete Structures using Fiber Model (파이버모델에 의한 철근콘크리트 구조물의 비선형 파괴해석)

  • 송하원;김일철;변근주
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.04a
    • /
    • pp.127-134
    • /
    • 1998
  • The objectives of this paper is to analyze the reinforced concrete structures by using fiber model. In this study, the fiber modeling techniques including modeling of support conditions are studied. In order to verify the modeling techniques, analysis results obtained for reinforced concrete cantilever beam and reinforced concrete T-girder bridge under cyclic loading are compared with experimental results from full scale test. From the comparison, it is shown that the modeling techniques in this study can be well applied to the nonlinear failure analysis of reinforced concrete structures with porper modifications.

  • PDF

Experimental Evaluation of the Effect of Steel-Seal and Hydro-Seal in Reinforced Concrete Structures (STEEL-SEAL 및 HYDRO-SEAL의 철근콘크리트 구조무에 미치는 영향에 대한 실험적 연구)

  • 전환석;이강균;배수호;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.287-292
    • /
    • 1997
  • Recent economic growths have accelerating much construction activities of various infrastructures, such as Express railway, Long-span bridges, Multi-story Buildings and etc. Reinforcement steel corrosion to be inevitably caused under the progress of these construction activities have been on and off serious problems in the site, which could incur another tragedic accident to us suffering from safety-ignorance disease. Thus, it is strongly requested to develop probable innovative products which could remove corrosive materials on rebars and also protect steel corrosion of reinforced concrete structures in the construction site. Hydro-Seal and Steel-Seal could solve these problems currently faced with in the construction site. The objective of this research is to experimentally evaluated the effect of Hydro-Seal and Steel-Seal in reinforced concrete structures, of which usage might affect the bond strength between steel and concrete, long-term compressive strength of concrete, corrosion resistance and etc. Related test results show that appropriate dosage of Hydro-Seal and Steel-Seal in reinforced concrete structures didnot affect physical properties of reinforced concrete structures.

  • PDF

Comparison of the seismic performance of Reinforced Concrete-Steel (RCS) frames with steel and reinforced concrete moment frames in low, mid, and high-rise structures

  • Jalal Ghezeljeh;Seyed Rasoul Mirghaderi;Sina Kavei
    • Steel and Composite Structures
    • /
    • v.50 no.3
    • /
    • pp.249-263
    • /
    • 2024
  • This article presents a comparative analysis of seismic behavior in steel-beam reinforced concrete column (RCS) frames versus steel and reinforced concrete frames. The study evaluates the seismic response and collapse behavior of RCS frames of varying heights through nonlinear modeling. RCS, steel, and reinforced concrete special moment frames are considered in three height categories: 5, 10, and 20 stories. Two-dimensional frames are extracted from the three-dimensional structures, and nonlinear static analyses are conducted in the OpenSEES software to evaluate seismic response in post-yield regions. Incremental dynamic analysis is then performed on models, and collapse conditions are compared using fragility curves. Research findings indicate that the seismic intensity index in steel frames is 1.35 times greater than in RCS frames and 1.14 times greater than in reinforced concrete frames. As the number of stories increases, RCS frames exhibit more favorable collapse behavior compared to reinforced concrete frames. RCS frames demonstrate stable behavior and maintain capacity at high displacement levels, with uniform drift curves and lower damage levels compared to steel and reinforced concrete frames. Steel frames show superior strength and ductility, particularly in taller structures. RCS frames outperform reinforced concrete frames, displaying improved collapse behavior and higher capacity. Incremental Dynamic Analysis results confirm satisfactory collapse capacity for RCS frames. Steel frames collapse at higher intensity levels but perform better overall. RCS frames have a higher collapse capacity than reinforced concrete frames. Fragility curves show a lower likelihood of collapse for steel structures, while RCS frames perform better with an increase in the number of stories.

The Study of detailng for concrete reinforcement and Seismic Analysis Method for Underground Reinforced Concrete Box Structures (지하 철근 콘크리트 박스 구조물의 내진해석방법 및 철근 배근 상세에 관한 연구)

  • Lee, Myoung-Soo;Han, Sang-Chel
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1215-1222
    • /
    • 2005
  • The object of this thesis is an study on detailing for concrete reinforcement and analytical study for seismic behavior of underground reinforced concrete box structures using the established seismic analytical method. Using the established seismic analytical method that has been presented in various documents seismic behavior of buried reinforce concrete box structures is compared. From the comparsion, it is shown that feasibility and detailing detailng for concrete reinforcement and seismic method for seismic analysis of buried reinforced concrete box structures.

  • PDF

An Experimental Study on the Fracture Safety of Reinforced Concrete Structures (철근콘크리트 구조물의 파괴 안전성에 관한 실험적 연구)

  • 채원규
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.1
    • /
    • pp.127-133
    • /
    • 1994
  • In this thesis, the fracture tests were performed on a series of reinforced concrete to investigate the variation of strength and the fracture safety of reinforced concrete structures. The specimens were of the same rectangular cross-section, of effective height 24cm and width 30cm and their span was 330cm. The three point loading system is used in the fracture tests. In these tests, the yield load, the ultimate load, the flexural strain and the mid-span displacement were detected. According to the results of these tests, the fracture behavior of reinforced concrete structures can be summarized as the follows : There Is no difference between the singly and doubly reinforced rectangular beams before the yield load. But from the yield load up to the ultimate load, the mid-span displacement of the singly reinforced rectangular beams are about two times larger than those of the doubly reinforced rectangular beams, The fracture energy of the doubly reinforced rectangular beams are one and half times compared to that of the singly reinforced rectangular beams. Based on the above investigation, it could be concluded that the doubly reinforced rectangular beam is more efficient to resist the brittle fracture than the singly reinforced rectangular beam.

  • PDF