• 제목/요약/키워드: reinforced concrete slab

검색결과 501건 처리시간 0.026초

Seismic behavior and strength of L-shaped steel reinforced concrete column-concrete beam planar and spatial joints

  • Chen, Zongping;Xu, Deyi;Xu, Jinjun;Wang, Ni
    • Steel and Composite Structures
    • /
    • 제39권3호
    • /
    • pp.337-352
    • /
    • 2021
  • The study presented experimental and numerical investigation on the seismic performance of steel reinforced concrete (SRC) L-shaped column- reinforced concrete (RC) beam joints. Various parameters described as steel configuration form, axial compressive ratio, loading angle, and the existence of slab were examined through 4 planar joints and 7 spatial joints. The characteristics of the load-displacement response included the bearing capacity, ductility, story drift ratio, energy-dissipating capacity, and stiffness degradation were analyzed. The results showed that shear failure and flexural failure in the beam tip were observed for planar joints and spatial joint, respectively. And RC joint with slab failed with the plastic hinge in the slab and bottom of the beam. The results indicated that hysteretic curves of spatial joints with solid-web steel were plumper than those with hollow-web specimens. The capacity of planar joints was higher than that of space joints, while the opposite was true for energy-dissipation capacity and ductility. The high compression ratio contributed to the increase in capacity and initial stiffness of the joint. The elastic and elastic-plastic story deformation capacity of L-shaped column frame joints satisfied the code requirement. A design formula of joint shear resistance based on the superposition theory and equilibrium plasticity truss model was proposed for engineering application.

강섬유 보강 콘크리트 인장성능 평가방법에 따른 지반 바닥슬래브의 설계 (Design of Ground Floor Slab According to the Method for Evaluating the Tensile Performance of Steel Fiber Reinforced Concrete)

  • 이종한;조백순;조창오
    • 콘크리트학회논문집
    • /
    • 제28권1호
    • /
    • pp.95-104
    • /
    • 2016
  • 강섬유가 보강된 콘크리트의 지반 바닥슬래브는 소성해석법인 항복선 이론을 바탕으로 평균강도 개념인 등가 휨 강도비로서 설계 휨강도를 평가하였다. 최근 유럽의 설계기준에서는 강섬유에 의한 인장성능을 균열이후의 잔류 휨강도를 직접 평가하도록 하였다. 따라서, 본 연구에서는 기존의 등가 휨강도비와 잔류 휨강도에 따른 인장성능을 실험적으로 평가하고, 하중의 등가 접촉반경과 상대강성반경 비에 의해 하중 위치별 휨 내력을 평가하였다. 설계 휨 내력은 ACI 360R-10 기준이 TR 34 (2003 & 2013)에 비해 과소 평가하였다. 또한, 잔류 휨강도로서 평가하는 TR 34 (2013)은 등가 휨강도비로 계산되어진 TR 34 (2003)의 휨 내력에 비해 다소 작게 평가하고 있지만, 그 차이는 크지 않았다.

국내 강섬유를 사용한 강섬유보강 콘크리트 슬래브 모델의 균열 및 변형특성 (Crack and Deformation Behaviors of Steel Fiber Reinforced Concrete Slab Model Specimens Using Domestic Steel Fiber)

  • 박승범;홍석주;이봉춘;조춘근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.319-324
    • /
    • 1999
  • This study is to investigate the properties on the load-deflection and fracture behaviors of the steel fiber reinforced concrete(SFRC) slab model specimens, Steel fibers of indent, crimp, and end hook shape were considered to reinforce the matrix under various mixing conditions and proportions. Initial cracking load, maximum load, and energy absorption capacity(load carrying capacity) of SFRC panel specimen increased with increase of steel fiber contents. And the plain concrete slab was fractured abruptly after maximum load but SRFC slabs were fractured smoothly by steel fibers in concrete matrix operated as cracking resistance force after maximum load. Indent, crimp and end hook shape steel fibers were effective in reinforcing the matrices but end hook type fiber were superior to indent and crimp type fibers.

  • PDF

A Study on the Effect of the ICCP System in Reinforced Concrete Specimens of Slab Type

  • Jeong, Jin-A;Ko, Kwon-Heum;Kim, Mun-Su;Lee, Du-Hyeong
    • Corrosion Science and Technology
    • /
    • 제17권6호
    • /
    • pp.272-278
    • /
    • 2018
  • Reinforced concrete (RC) has been used as a construction material in various environments, such as airports, bridges, and ocean concrete structures, etc. Over time, however, rebar in the concrete is prone to corrosion from environmental forces and structural defects of the concrete. Cathodic protection (CP) was invented to prevent problems with corrosion and is widely used for different applications. Cathodic protection is divided into two types: sacrificial anode cathodic protection (SACP) and impressed current cathodic protection (ICCP). There are several limitations to the use of sacrificial anode cathodic protection in complex reinforced concrete structures, including concrete resistivity, throwing power of the CP, and environmental conditions. These limitations can affect the protection performance of SACP. Therefore, we used impressed current cathodic protection in our study. We tested Ti-Mesh, Ti-Rod, and Ti-Ribbon anodes in slab type reinforced concrete specimens. Electrochemical tests were conducted to confirm the impressed current cathodic protection performance under different environmental conditions.

A new SDOF method of one-way reinforced concrete slab under non-uniform blast loading

  • Wang, Wei;Zhang, Duo;Lu, Fangyun;Liu, Ruichao
    • Structural Engineering and Mechanics
    • /
    • 제46권5호
    • /
    • pp.595-613
    • /
    • 2013
  • A new effective model for calculation of the equivalent uniform blast load for non-uniform blast load such as close-in explosion of a one-way square and rectangle reinforced concrete slab is proposed in this paper. The model is then validated using single degree of freedom (SDOF) system with the experiments and blast tests for square slabs and rectangle slabs. Test results showed that the model is accurate in predicting the damage level on the tested RC slabs under the given explosive charge weight and stand-off distance especially for close-in blast load. The results are also compared with those obtained by conventional SDOF analysis and finite element (FE) analysis using solid elements. It is shown that the new model is more accurate than the conventional SDOF analysis and is running faster than the FE analysis.

척산천의 다기능 어도의 구조 해석 (Structural Analysis of Multipurpose Fishway in Chuksan River)

  • 이영재;이정신;김문기;박성식;장형규
    • 한국농공학회논문집
    • /
    • 제59권1호
    • /
    • pp.97-107
    • /
    • 2017
  • In this study, the validity and applicability of the multipurpose fishway which has been constructed for the upstream migration of fish at Chuksan river in Uljin is assessed and analyzed by a commercial software. The upper slab types of fishway in this investigation are reinforced concrete slab (S1 type) and reinforced concrete slab with steel plate (S2 type). The three different sizes of subway passage ($0.8m{\times}0.1m$, $0.8m{\times}0.2m$, $0.8 m{\times}0.3m$) and velocities (0.6 m/s, 1.2 m/s, 1.8 m/s) of Chuksan fishway was investigated and compared for the Chuksan in government design code. The analysis showed that the maximum stress and bending moment of S1 type decreased 1~21 % and 12~27 % compared to the Chuksan in government design code, respectively. Also, the maximum stress of and bending moment of S2 type decreased 11~32 % and 27~39 %. From the numerical analysis, it was found that the S2 type was greatly effective and the subway passage size of $0.8m{\times}0.2m$ was most safe. This result can be utilized to be the basic data for design of the Multipurpose fishway.

폐유리를 잔골재로 활용한 강섬유보강 슬래브모델의 내력 및 변형률특성 (Load Carrying Capacity and Deformation Properties of Steel Fiber Reinforced Concrete Slab Model Utilizing Waste Glass by Fine Aggregates)

  • 박승범;김경훈;이봉춘;이준;정명일
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.385-390
    • /
    • 2003
  • As growing of industrialization and increasing of population, the quantities of waste glasses are rapidly growing in the earth. It cause some problems such as the waste of natural resources and environmental pollution. In this context, recycling waste glass as a material of concrete has a great advantage environmentally and economically. This study is aimed to investigate the effect of load and deflection on fiber reinforced concrete slab model utilizing waste glass by fine aggregates. The flexural strength of the concrete including waste glass increased considerably, as the inclusion rate of steel fiber were increased. And the first crack load, maximum load and energy absorption capacity increased remarkably as the inclusion rate of steel fiber were increased. Therefore, in this study we confirmed the possibility of application for the usage of waste glass to the steel fiber reinforced concrete.

  • PDF

포스트텐션된 철근콘크리트 슬래브의 보 이론에 의한 연구 (A Study on Post-Tensioned Reinforced Concrete Slab by the Beam Theory)

  • 한봉구;김덕현
    • Composites Research
    • /
    • 제22권5호
    • /
    • pp.24-29
    • /
    • 2009
  • 본 논문에서는 포스트텐션된 철근콘크리트 슬래브를 특별직교이방성 복합적층판 이론으로 해석하였다. 슬래브의 해석에 있어 단면의 기하학적, 물리적 특성이 중립면에서 휨-연계강성 $B_{ij}=0$ 이고, $D_{16}=D_{26}=0$ 임을 고려하였다. 철근콘크리트 슬래브는 특별직교이방성판으로 거동한다. 이러한 경계조건을 갖는 단면 혹은 불규칙한 단면을 갖는 시스템은 해석적 해를 구하기가 매우 어렵다. 이러한 문제에 대한 해석을 위해서 유한차분법이 이용되었다. 본 논문에서는 유한차분법과 보 이론을 해석을 위해 사용되었다. 그 결과 보 이론에 의한 해석 값이 판 이론의 값에 근접함을 알 수 있었다.

데크플레이트와 경량성형재가 결합된 슬래브의 차음성능에 대한 실물실험 평가 (A Study on the Sound Insulation for Void-deck Slab Combined with Deck Plate and Polystyrene Void Foam)

  • 노영숙;윤성호
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.60-65
    • /
    • 2015
  • This study is to explore floor impact sound and sound insulation of reinforced concrete structure with void-deck slab system which combines polystyrene void foam and T-shaped steel deck plate. A void-deck slab system can effectively reduce the amount of concrete used and hence the mass of a reinforced concrete slab. Also void slab system has dynamically favorable for bending. Three-bay 2-story building was constructed as a mock up test specimen using void-deck slab system and floor impact sound was measured to valuate sound insulation performance. Light weight floor impact and heavy weight floor impact were investigated. Light weight floor impact pressure levels were 32dB, 28dB, and 29db at representative locations which are $1^{st}$ level in the floor impact sound insulation performance grading system. The heavy-weight floor impact pressure levels were 44dB, 45dB, and 43dB at representative locations which are $2^{nd}$ level in the floor impact sound insulation performance grading system. Therefore void-deck slab system can be used in public housing apartment building in terms of not only effectively reduced construction materials but also floor impact sound insulation.

집중하중 조합에 의한 섬유 보강 콘크리트 바닥슬래브의 설계 휨 내력 (Effect of the Combination of Point Loads on the Design Flexural Capacity for Fiber Reinforced Concrete Floor Slab)

  • 이종한;조백순;김정식;조범구;김한식
    • 한국건설순환자원학회논문집
    • /
    • 제4권1호
    • /
    • pp.47-54
    • /
    • 2016
  • 본 연구에서는 섬유 보강 콘크리트 바닥슬래브의 주요 설계하중인 선반하중과 이동하중에 의한 휨 내력을 평가하였다. 설계기준을 바탕으로 각 하중의 크기와 작용면적을 정의하였으며, 그 관계를 분석하였다. 단일하중에 의해서는 슬래브 경계면에서 휨 내력이 평가되어야 하며, 슬래브 두께 180mm 이상, 콘크리트 강도 35MPa 이상일 때는 최소 등가 휨강도비로써 휨 내력을 충분히 만족하였다. 조합하중에 의해서는 선반하중간의 조합이 가장 큰 등가 휨강도비를 요구하였으며, 선반하중과 이동하중의 조합은 선반하중간의 조합에 비해서는 작게 평가되었고, 단일 하중에 비해서는 크게 평가되었다. 본 연구결과 섬유 보강 콘크리트 바닥슬래브의 휨 설계는 하중 조합에 의한 내력 평가가 필요함을 확인하였다.