• 제목/요약/키워드: reinforced concrete joints

검색결과 321건 처리시간 0.025초

탄소 FRP를 이용한 철근콘크리트 보-기둥 접합부의 내진 성능 보강 실험 (An Experimental Study on Seismic Retrofitting of RC Beam-Column Connections with Carbon FRP)

  • 김민;이기학;이재홍;우성우;이정원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.263-266
    • /
    • 2005
  • Many RC structures built without seismic provisions have exhibited brittle shear failures in the beam-column joint area, and resulted in large permanent deformations and structural collapse. This paper presents the results of an experimental investigation pertaining to the use of carbon fiber-reinforced polymer(FRP) for strengthening of RC beam-column connections. The selective upgrade is obtained by choosing different combinations and locations of carbon FRP sheets to determine the effective way to improve the structural performance of joints. Experimental results demonstrate significant improvement of flexural capacity and ductility of beam-column connections originally built without seismic details.

  • PDF

Simplified nonlinear simulation for composite segmental lining of rectangular shield tunnels

  • Zhao, Huiling;Liu, Xian;Yuan, Yong
    • Structural Engineering and Mechanics
    • /
    • 제81권4호
    • /
    • pp.513-522
    • /
    • 2022
  • Steel-concrete composite segments replacing the conventional reinforced concrete segments can provide the rectangular shield tunnel superiorities on bearing capacity, ductility and economy. A simplified model with high-efficiency on computation is proposed for investigating the nonlinear response of the rectangular tunnel lining composed of composite segments. The simulation model is developed by an assembly of nonlinear fiber beam elements and spring elements to express the transfer mechanism of forces through components of composite segments, and radial joints. The simulation is conducted with the considerations of material nonlinearity and geometric nonlinearity associated with the whole loading process. The validity of the model is evaluated through comparison of the proposed nonlinear simulation with results obtained from the full-scale test of the segmental tunnel lining. Furthermore, a parameter study is conducted by means of the simplified model. The results show that the stiffness of the radial joint at haunch of the ling and the thickness of inner steel plate of segments have remarkable influence on the behaviour of the lining.

벽-슬래브 접합부에 매립된 열교차단장치의 반복하중에 대한 거동특성 평가 (Cyclic Structural Characteristics of Thermal Bridge Breaker Systems embedded in Reinforced Concrete Slabs)

  • 신동현;오명호;김영호;김형준
    • 한국전산구조공학회논문집
    • /
    • 제28권5호
    • /
    • pp.511-521
    • /
    • 2015
  • 건물외피 발생하는 열교현상은 건물의 단열성능 및 외피의 내구성에 영향을 미치며, 국내의 일반적인 주거형식인 공동주택의 발코니에 있어서 이러한 열교현상은 중요하게 고려되고 있다. 이와 같이 내 외부 발코니 슬래브 사이에서 발생하는 열교현상을 최소화하기 위한 목적으로 열교차단장치가 개발되었으며 다수의 건설현장에서 적용되고 있다. 철근콘크리트 슬래브 벽-슬래브 접합부에 열교차단장치를 적용함으로써 건물의 단열성능을 향상될 수 있으나 풍하중과 같은 양방향의 하중에 의해 열교차단장치 삽입부위가 적합한 구조성능을 확보하고 있는지에 대한 검증이 요구된다. 따라서 본 연구에서는 철근콘크리트 슬래브에 적용된 열교차단장치의 구조성능을 확인하기 위해 변위제어 방식으로 30 싸이클의 반복하중을 가력하였다. 열교차단장치가 삽입된 접합부는 요구되는 구조성능을 확보하며, 최대 모멘트강도, 에너지소산능력, 연성비가 기존의 철근콘크리트 슬래브와 비교하여 향상되는 것으로 나타났다.

섬유시트와 매입형 CFRP Rod를 보강한 R/C 외부 보-기둥 접합부의 내진성능 평가 및 개선 (Improvement and Evaluation of Seismic Performance of Reinforced Concrete Exterior Beam-Column Joints Retrofitting with Fiber Reinforced Polymer Sheets and Embedded CFRP Rods)

  • 하기주;하영주;강현욱
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.151-159
    • /
    • 2015
  • 본 연구에서는 기존 철근콘크리트 구조물 보-기둥 접합부의 내진성능의 개선을 위해 보-기둥 접합부 영역을 FRP보강재 (탄소섬유시트, 아라미드섬유시트, 매입형 CFRP Rod)를 사용하여 보강한 후 내진성능을 평가하였다. 총 7개의 실험체를 제작하고 실험을 수행하여 내진성능을 평가하였으며, 본 연구의 실험결과를 근거로 다음과 같은 결론을 얻었다. 기존 철근콘크리트 보-기둥 접합부의 접합부 영역을 보강한 결과, 초기 재하시 접합부 영역의 균열억제 효과와 재하 전 과정을 통하여 보강재의 구속효과로 인하여 균열억제 효과가 커서 안정적인 파괴형태 및 내력향상 효과를 나타내었다. 매입형 CFRP Rod와 탄소섬유시트를 활용한 R/C 외부 보-기둥 접합부 실험체 LBCJ-CRUS는 표준실험체 LBCJ와 비교하여 변위연성 4, 7에서 각각 최대내력은 1.54배, 에너지소산능력은 2.36배 증가하였다. 그리고 실험체 LBCJ-CS, LBCJ-AF시리즈는 변위연성 7에서 표준실험체 LBCJ 보다 에너지소산능력이 각각 2.04~2.34, 1.63~3.02배 증가하였다.

Test of Headed Reinforcement in Pullout II: Deep Embedment

  • Choi, Dong-Uk
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권3E호
    • /
    • pp.151-159
    • /
    • 2006
  • A total of 32 pullout tests were performed for the multiple headed bars relatively deeply embedded in reinforced concrete column-like members. The objective was to determine the minimum embedment depth that was necessary to safely design exterior beam-column joints using headed bars. The variables for the experiment were embedment depth of headed bar, center-to-center distance between adjacent heads, and amount of supplementary reinforcement. Regular strength concrete and grade SD420 reinforcing steel were used. The results of the test the indicated that a headed bar embedment depth of $10d_b$ was not sufficient to have relatively closely installed headed bars develop the pullout strength corresponding to the yield strength. All the experimental variables, influenced the pullout strength. The pullout strength increased with increasing embedment depth and head-to-head distance. It also increased with increasing amount of supplementary reinforcement. For a group of closely-spaced headed bars installed in a beam-column joint, it is recommended to use column ties at least 0.6% by volume, 1% or greater amount of column main bars, and an embedment depth of $13d_b$ or greater simultaneously, to guarantee the pullout strength of individual headed bars over 125% of $f_y$ and ductile load-displacement behavior.

Design and behavior of 160 m-tall post-tensioned precast concrete-steel hybrid wind turbine tower

  • Wu, Xiangguo;Zhang, Xuesen;Zhang, Qingtan;Zhang, Dong;Yang, Xiaojing;Qiu, Faqiang;Park, Suhyun;Kang, Thomas H.K.
    • Steel and Composite Structures
    • /
    • 제44권3호
    • /
    • pp.407-421
    • /
    • 2022
  • Prefabricated hybrid wind turbine towers (WTTs) are promising due to height increase. This study proposes the use of ultra-high performance concrete (UHPC) to develop a new type of WTT without the need to use reinforcement. It is demonstrated that the UHPC WTT structure without reinforcing bars could achieve performance similar to that of reinforced concrete WTTs. To simplify the design of WTT, a design approach for the calculation of stresses at the horizontal joints of a WTT is proposed. The stress distribution near the region of the horizontal joint of the WTT structure under normal operating conditions and different load actions is studied using the proposed approach, which is validated by the finite element method. A further parametric study shows that the degree of prestressing and the bending moment both significantly affect the principal stress. The shear-to-torsion ratio also shows a significant influence on the principal tensile stress.

Friction-based beam-to-column connection for low-damage RC frames with hybrid trussed beams

  • Colajanni, Piero;Pagnotta, Salvatore
    • Steel and Composite Structures
    • /
    • 제45권2호
    • /
    • pp.231-248
    • /
    • 2022
  • Hybrid Steel-Trussed Concrete Beam (HSTCB) is structural typology suitable for light industrialization. HSTCBs usually cover long span with small depths, which lead to significant amount of longitudinal rebars. The latter make beam-column joints more prone to damage due to earthquake-induced cyclic actions. This phenomenon can be avoided using friction-based BCCs. Friction devices at Beam-to-Column Connections (BCCs) have become promising solutions to reduce the damage experienced by structural members during severe earthquakes. Few solutions have been developed for cast-in-place Reinforced Concrete (RC) and steel-concrete composite Moment Resisting Frames (MRFs), because of the difficulty of designing cost-effective damage-proof connections. This paper proposes a friction-based BCC for RC MRFs made with HSTCBs. Firstly, the proposed connection is described, and its innovative characteristics are emphasized. Secondly, the design method of the connection is outlined. A detailed 3D FE model representative of a beam-column joint fitted with the proposed connection is developed. Several monotonic and cyclic analyses are performed, investigating different design moment values. Lastly, the numerical results are discussed, which demonstrate the efficiency of the proposed solution in preventing damage to RC members, and in ensuring satisfactory dissipative capacity.

강재판형 이력댐퍼 연결부재와 RC벽체의 접합상세에 따른 구조거동 (Structural Behavior of Joints between the Hysteretic Steel Damper Connector and RC Wall Depending on Connection Details)

  • 강인석;허무원
    • 콘크리트학회논문집
    • /
    • 제24권6호
    • /
    • pp.737-744
    • /
    • 2012
  • 강재형 댐퍼는 주로 철골구조에서 많이 사용되어 왔으나 최근에 들어 철근콘크리트 건물에도 사용빈도가 증가하는 추세이다. 철근콘크리트 건물에 강재이력댐퍼를 적용하기 위해서는 댐퍼의 접합부재가 댐퍼의 지지능력을 보 및 벽체로 전달하기에 적합한 강도와 강성을 지녀야만 한다. 하지만 균열로 인한 철근콘크리트 요소의 손상은 부득이한 것으로, 댐퍼로부터 지지부재로의 하중전달 메커니즘과 댐퍼 지지부재 이력특성의 규명은 이러한 댐퍼의 거동을 평가하는데 매우 중요하다. 이에 이 연구에서는 EaSy 댐퍼와 같은 강재판형 이력댐퍼의 지지부재와 RC벽체와의 접합상세를 대상으로 실험을 실시하였다. 실험 결과 전단과 관련된 균열의 양과 패턴을 제외하고는 모든 실험체의 파괴패턴은 거의 동일한 것으로 나타났으며, 잘 분산된 균열을 지닌 HD-3 실험체가 에너지소산능력, 강성저하 그리고 강도저하 측면에서 좋은 거동을 보여주었다.

Numerical analysis of under-designed reinforced concrete beam-column joints under cyclic loading

  • Sasmal, Saptarshi;Novak, Balthasar;Ramanjaneyulu, K.
    • Computers and Concrete
    • /
    • 제7권3호
    • /
    • pp.203-220
    • /
    • 2010
  • In the present study, exterior beam-column sub-assemblage from a regular reinforced concrete (RC) building has been considered. Two different types of beam-column sub-assemblages from existing RC building have been considered, i.e., gravity load designed ('GLD'), and seismically designed but without any ductile detailing ('NonDuctile'). Hence, both the cases represent the under-designed structure at different time frame span before the introduction of ductile detailing. For designing 'NonDuctile' structure, Eurocode and Indian Standard were considered. Non-linear finite element (FE) program has been employed for analysing the sub-assemblages under cyclic loading. FE models were developed using quadratic concrete brick elements with embedded truss elements to represent reinforcements. It has been found that the results obtained from the numerical analysis are well corroborated with that of experimental results. Using the validated numerical models, it was proposed to correlate the energy dissipation from numerical analysis to that from experimental analysis. Numerical models would be helpful in practice to evaluate the seismic performance of the critical sub-assemblages prior to design decisions. Further, using the numerical studies, performance of the sub-assemblages with variation of axial load ratios (ratio is defined by applied axial load divided by axial strength) has been studied since many researchers have brought out inconsistent observations on role of axial load in changing strength and energy dissipation under cyclic load.

Efficient parameters to predict the nonlinear behavior of FRP retrofitted RC columns

  • Mahdavi, Navideh;Ahmadi, Hamid Reza;Bayat, Mahmoud
    • Structural Engineering and Mechanics
    • /
    • 제70권6호
    • /
    • pp.703-710
    • /
    • 2019
  • While fiber-reinforced plastic (FRP) materials have been largely used in the retrofitting of concrete buildings, its application has been limited because of some problems such as de-bonding of FRP layers from the concrete surface. This paper is the part of a wide experimental and analytical investigation about flexural retrofitting of reinforced concrete (RC) columns using FRP and mechanical fasteners (MF). A new generation of MF is proposed, which is applicable for retrofitting of RC columns. Furthermore, generally, to evaluate a retrofitted structure the nonlinear static and dynamic analyses are the most accurate methods to estimate the performance of a structure. In the nonlinear analysis of a structure, accurate modeling of structural elements is necessary for estimation the reasonable results. So for nonlinear analysis of a structure, modeling parameters for beams, columns, and beam-column joints are essential. According to the concentrated hinge method, which is one of the most popular nonlinear modeling methods, structural members shall be modeled using concentrated or distributed plastic hinge models using modeling parameters. The nonlinear models of members should be capable of representing the inelastic response of the component. On the other hand, in performance based design to make a decision about a structure or design a new one, numerical acceptance should be determined. Modeling parameters and numerical acceptance criteria are different for buildings of different types and for different performance levels. In this paper, a new method was proposed for FRP retrofitted columns to avoid FRP debonding. For this purpose, mechanical fasteners were used to achieve the composite behavior of FRP and concrete columns. The experimental results showed that the use of the new method proposed in this paper increased the flexural strength and lateral load capacity of the columns significantly, and a good composition of FRP and RC column was achieved. Moreover, the modeling parameters and acceptance criteria were presented, which were derived from the experimental study in order to use in nonlinear analysis and performance-based design approach.