International Journal of Concrete Structures and Materials
/
제9권4호
/
pp.401-413
/
2015
In this study the progressive collapse resisting capacity of a RC beam-column subassemblage with and without strengthening was investigated. Total of five specimens were tested; two unreinforced specimens, the one designed as gravity load-resisting system and the other as seismic load-resisting system, and three specimens reinforced with: (i) bonded strand, (ii) unbonded strand, and (iii) side steel plates with stud bolts. The two-span subassemblages were designed as part of an eight-story RC building. Monotonically increasing load was applied at the middle column of the specimens and the force-displacement relationships were plotted. It was observed that the gravity load-resisting specimen failed by fractures of re-bars in the beams. In the other specimens no failure was observed until the maximum displacement capacity of the actuator was reached. Highest strength was observed in the structure with unbonded strand. The test result of the specimen with side steel plates in beam-column joints showed that the force-displacement curve increased without fracture of re-bars. Based on the test results it was concluded that the progressive collapse resisting capacity of a RC frame could be significantly enhanced using unbonded strands or side plates with stud bolts.
International Journal of Concrete Structures and Materials
/
제6권1호
/
pp.19-29
/
2012
In this study, three isolated interior flat slab-column connections that include three types of shear reinforcement details; stirrup, shear stud and shear band were tested under reversed cyclic lateral loading to observe the capacity of slab-column connections. These reinforced joints are 2/3 scale miniatures designed to have identical punching capacities. These experiments showed that the flexural failure mode appears in most specimens while the maximum unbalanced moment and energy absorbing capacity increases effectively, with the exception of an unreinforced standard specimen. Finally, the results of the experiments, as wel l as those of experiments previously carried out by researchers, are applied to the eccentricity shear stress model presented in ACI 318-08. The failure mode is therefore defined in this study by considering the upper limits for punching shear and unbalanced moment. In addition, an intensity factor is proposed for effective widths of slabs that carry an unbalanced moment delivered by bending.
With the increase of the skyscraper center, the development of large-diameter and high-strength reinforcing bars is being carried out to solve the dense reinforcement. In case of the steel reinforced concrete with a small cross section such as beam-column joints, the development length becomes short when straight bars are used. Therefore, it is possible to solve the problem that the development length becomes short by using the bearing strength of the hooked bar and headed bar. In this study, the exterior beam-column joint test of SD700 hooked bar and headed bar with anchorage length of 20db was conducted to extend the development length limitation of hooked bar and headed bar. As a result of the evaluation of the anchorage strength using the design equation by KCI, the average of the [measured value]/[predicted value] ratio was 1.31 for the hooked reinforcing bars. In the case of headed bars, the average of the [measured value]/[predicted value] ratio was 1.12. In addition, in order to compare the anchorage performance of the hooked bar and the headed bar, the measured values were divided by the square root of the compressive strength of the concrete to compare the anchorage strength. Under the same conditions, the anchorage strength of headed bars was 8.5% higher than the hooked bars.
Xie, Qiang;Sinaei, Hamid;Shariati, Mahdi;Khorami, Majid;Mohamad, Edy Tonnizam;Bui, Dieu Tien
Steel and Composite Structures
/
제30권5호
/
pp.433-441
/
2019
The aim of this research is reinforcing of concrete with variety of fiber reinforced polymer (FRP) configurations and investigates the load capacity and ductility of these connections using an experimental investigation. Six scaled-down RC exterior joints were tested under moderately monotonic loads. The results show that, the shape of the FRP had a different effect on the joint capacity and the connection ductility coefficient. The greatest effect on increasing the ductility factor was seen in the sample where two reinforcement plates were used on both sides of the beam web (RCS5 sample). For the sample with the presence of FRP plates at the top and bottom of the beam (RCS3 sample), the ductility factor was reduced even the load capacity of this sample increased. Except for the RCS3 sample, the rest of the samples exhibited an increase in the ductility factor due to the FRP reinforcement.
최근 시공의 합리화와 경제성의 목적으로 한 다양한 연구가 진행되고 있다. 철근 콘크리트 기둥과 철골 보로 이루어진 RCS 구조의 개발에 대한 연구 역시 활발해지고 있다. RCS 구조 보-기둥 접합부 패널존의 저항기구는 내부패널에서 외부패널로 응력이 전달될 때 직교보의 영향을 받지만, 기존연구에는 직교보의 영향을 고려하지 않고 있다. 본 연구에서는 웨브, 플랜지, 직교보의 두께, FBP의 유뮤등 다양한 변수들을 가지는 5개의 철근콘크리트 기둥과 철골보로 이루어진 보-기둥 내부접합부 실험체의 실험을 통해 직교보들의 영향과 구조적 성능을 조사하고자 한다. 이러한 실험결과들로부터, 보-기둥 접합부의 직교보가 전단내력과 구조성능을 향상시키는데 효과적이라는 것을 알 수 있다.
본 연구에서는 중 고층 철근콘크리트 주상복합형 건축물에서 지진하중과 같은 반복하중이 작용할 때 단차형 내부 보-기둥 접합부의 거동 특성을 파악하기 위하여 단차 유무에 따른 내부 보-기둥 접합부 실험체를 대상으로 실험을 실시하여 다음과 같은 결론을 얻었다. 단차가 있는 내부 보-기둥 접합부 실험체는 단차가 없는 표준실험체(FJ-0D)와 비교하여 단차 수준(1.0D, 2.0D)이 증가함에 따라 수평내력과 에너지소산능력이 증가하였고 내부 보-기둥 접합부 영역을 중심으로 균열진전 상황이 상이하였다. 또한 에너지소산능력은 내부 보-기둥 접합부 단차가 높을수록 1.1${\sim}$1.35배 증가하였다.
This study is aimed at investigating the dynamic performance of a composite building structure under seismic ground motions. The building structure is an official fire department building located in southern Taiwan. It is composed of a seven-story reinforced concrete (RC) and an eight-story steel reinforced concrete (SRC) frame. Both frames share a common basement and are separated by expansion joints from the first to the seventh floor. Recorded floor accelerations of the building structure under eight earthquakes occurring during the period from 2011 to 2013 were examined in this paper. It is found that both frames had similar floor acceleration amplifications in the longitudinal direction, while the SRC frame revealed larger response than the RC frame in the transverse direction. Almost invariant and similar fundamental periods under the eight earthquakes in both directions were obtained from their transfer functions. Furthermore, numerical time-history simulations were carried out for the building structure under the most intensive earthquake. It is realized that the seismic response of the composite building was dominated by the first translational mode in each horizontal direction. Higher modes did not significantly contribute to the structural response. The conventional Rayleigh damping model could be appropriately applied to the time-history simulations under bi-directional excitations. Approximate floor acceleration envelopes were obtained with a compound RC and SRC structural model by using the average damping ratios determined from the different structural arrays.
원자력발전소에서 철판이나 폴리머 라이너 판은 가스나 액체가 격남건물 외부로 누설되지 않도록 하기 위하여 채택되었다. 만일 어떤 사고가 발생하여 이 판이 손상을 입는 다면 콘크리트는 안전성 요구 측면에서 최후의 보루가 되어야 한다. 그 능력을 구명하기 위하여 본 논문에서는 시공이음의 유 무와 습윤조건 및 하중상태가 콘크리트의 누설저항성에 미치는 영향을 검토하기 위한 연구가 수행되었다. 실험결과로부터, 습윤상태에 시공이음이 있는 경우, 가스의 누설은 압력이 $1kg/cm^2$부터 시작되었으나 시공이음이 없는 경우는 $2kg/cm^2$부터 누설이 시작됨을 알 수 있었다. 또한, 기건 및 무재하 상태에는 시공이음의 유 무에 관계없이 콘크리트에 존재하는 가스의 통로가 일정하므로 누설량이 일정한 경향을 가지고 증가하였다. 최종적으로 재하상태에는 Okamoto et al.(1995)의 연구에서설명하는 바와 같이 누설량이 벽체의 두께에 반비례하므로 실제 발전소에 설치되는 벽체 두께를 고려하면 시공이음에 있어도 가스의 밀봉에는 문제가 없을 것으로 판단된다.
이 연구에서는 순환굵은골재와 고로슬래그미분말을 치환한 콘크리트를 철근콘크리트 외부 보-기둥 접합부의 위험단면영역에 하이브리드 섬유 (PVA섬유+강섬유)를 적용한 외부 보-기둥 접합부 실험체를 7개 제작하여 실험을 수행하여 내진성능을 평가하였다. 이 연구의 실험결과를 근거로 다음과 같은 결론을 얻었다. 철근콘크리트 보-기둥 접합부의 접합부 영역에 하이브리드섬유를 보강한 결과 초기 재하시 접합부 영역의 균열억제 효과와 재하 전 과정을 통하여 하이브리드섬유의 가교역할로 인하여 균열억제 효과가 커서 안정적인 파괴형태 및 내력향상 효과를 나타내었다. 철근콘크리트 보-기둥 접합부영역에 하이브리드섬유를 보강한 실험체 BCJGPSR 시리즈는 표준실험체 BCJS와 비교하여 최대내력은 1.01~1.04배 증가하였다. 그리고 에너지 소산능력은 1.06~1.29배 증가하였다. 또한 하이브리드섬유 (강섬유+PVA섬유)를 보강한 실험체 $BSJGPSR_1$은 최대강도를 확보한 변위연성 9에서 실험체 BCJS, BCJP, BCJGPR 시리즈 보다 에너지 소산능력이 1.33~1.65배 증가한 것으로 나타났다.
본 논문에서는 국내 비내진상세 조적채움벽 RC 골조의 내진성능을 파악하기 위하여 실규모 크기의 비내진상세 조적채움벽 RC 골조를 대상으로 정적실험을 실시하였으며, 기존 비내진상세 RC 골조 의 정적 실험결과와의 비교 분석을 통하여 조적채움벽체가 RC 골조의 내진성능에 미치는 영향에 대하여 평가하였다. 실험 결과. 조적채움벽 RC 골조 실험체는 조적채움벽체에 의한 압축력으로 기둥, 보, 접합부 등 골조 전체에 균열 등의 손상이 발생하였으며, 접합부 전단균열이 벌어지고 철근이 노출되면서 취성 파괴되었다. 한편, 조적체움벽 RC 골조 실험체의 수평하중과 층간변형각 관계는 벽체 슬라이딩 균열, 기둥 균열 등으로 강성이 저하되었으며, 철근 항복이후 최대 내력에 도달하고 접합부 균열의 확대, 철근 노출 등으로 내력이 최대 내력의 40% 정도로 저하되었다. 조적채움벽체로 인하여 기둥 상 하단 및 접합부에만 집중되던 손상이 기둥, 보, 접합부 등 골조 전체에 분산되어 발생하였으며, 기둥의 전단균열이 아닌 접합부의 전단균열의 확대로 최종 파괴되었다. 또한, 조적채움벽체로 인하여 RC 골조의 강성은 12.42배, 내력은 3.63배 증가한 반면에, 강성 증가에 따라 최대 내력 시의 층간변형각은 0.18배, 파괴시의 변형은 절반 이하로 감소하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.