• 제목/요약/키워드: rehabilitation equipment

검색결과 174건 처리시간 0.024초

무릎관절 멀리건 테이핑이 균형능력과 각근력에 미치는 효과와 측정의 반복에 의한 효과 비교 (Comparison of the Balancing Capacity and Strength of Taping for the Knee Joint and Repeated Measurements)

  • 박보현;최수홍;김성중;박수형;오강오
    • 대한정형도수물리치료학회지
    • /
    • 제24권2호
    • /
    • pp.9-15
    • /
    • 2018
  • Background: The purpose of this study was to compare the effects of mulligan taping on knee joints on balance ability and strength with repeated measurements. Methods: Seventeen patients were randomly assigned to the 8 taping group and the 9 repeat measurement group. To measure the balance ability, fall risk assessment equipment was used, and the measurement of the muscle strength was performed by using the equipment of the same company. Results: Balanced abilities and muscle strength were increased in groups with taping only after Mulligan taping. Conclusions: The application of mulligan taping did not have the effect of stimulating the inherent receptive sensation. However, active grouping of the knee joint taping only, and muscle strength and muscle strength were increased. It increases the stability and activity of the muscles that operate on the balance of the active knee joint and muscle strength, thereby enhancing exercise prevention and prevention performance and exercise performance.

EMG Activities of Core Muscles During Bridging Exercises With and Without a Pilates Resistive Device

  • Kim, Su-Jin;Yoo, Won-Gyu;Kim, Min-Hee;Yi, Chung-Hwi
    • 한국전문물리치료학회지
    • /
    • 제14권4호
    • /
    • pp.21-27
    • /
    • 2007
  • The purposes of this study were to compare core muscle activities with and without the use of Pilates resistive equipment during bridging exercises and to investigate the efficacy of a Pilates device. Fourteen healthy individuals (6 males, 8 females) between 20 to 26 years of age were examined. They were engaged in a bridging exercise with and without a magic circle. Three consecutive repetitions of each exercise were performed. Surface electromyography (sEMG) was used to measure the electrical activities of the right side internal oblique, the adductor longus, the multifidus, and the gluteus maximus muscles. Normalized EMG activities were compared using a paired t-test and the level of significance was set at =.05. The results showed that the EMG activities of the internal oblique (p=.0078), the adductor longus (p=.0007), and the gluteus maximus (p=.0001) muscles were significantly higher when using the magic circle during the Pilates bridging exercise. Also, statistically significant change existed in the multifidus muscle (p=.0106). The bridging exercise, combined with hip adduction using the magic circle, may enhance core stabilization. Therefore, using a magic circle during hip adduction combined with bridging exercise may be recommended usefully for individuals wanting to strength the core muscles. Further research is needed to access the nature of motor control of the Pilates mat exercises and to deliver exercise intervention for lower back pain patients.

  • PDF

슬링운동치료를 이 용한 Neurac 기법의 이론적 근거와 적용방법 (Theoretical Basis and Application of the Neurac Technique Which Uses the Sling Exercise Therapy)

  • 김선엽;김택연
    • 대한정형도수물리치료학회지
    • /
    • 제12권2호
    • /
    • pp.52-65
    • /
    • 2006
  • Sling exercises therapy can speak as appliable comprehensive exercises therapy technique efficiently in general exercise field for injured worker's rehabilitation process and health improvement patient or athlete, injury or disease that have pain or dysfunction to neuromuscular system using that shake. At 1990 an early stage, because physical therapist and doctors of medical treatment developed country norway of north europe cooperate sling exercises therapy's concept trend spreading worldwide establishing theory newly based on scientific basic be. Musculoskeletal system, old man and young child's nervous system injurer's treatment and exercise and industry worker's rehabilitation process, athlete's rehabilitation etc. several fields introduced in early 2000s to Korea apply. Sling exercises therapy neuromuscular system disease continuous abatement as general concept of active exercise and treatment that use sling exercises equipment by purpose know can. This review article wishes to introduce about neuromuscular activation, "Neurac" technique that can speak as step developed more concept based on application principle etc, of basic sling exercises effort's change by suspension point's change that is concept, stability exercises principle, open kinetic chain exercises and closed kinetic chain exercises. Arranged about Plateau potential's characteristic and working mechanism and Neurac technique's application method that can say as Neurac technique's neuro-physiologic base, and presented treatment method of lumbar part disease and cervical part, shoulder joint part disease to application example. Because plateau potential forward player that induce using Neurac technique in part muscles that act role that keep spine surrounding stability in this article keeps muscle's contraction continuously, between global and local muscles, presented several study findings that can cause affirmative change in insufficient muscle adjustment state such as imbalance of muscles' action order. Expect that case studies that use this Neurac technique here after consist continuously.

  • PDF

은 나노입자 프린팅 기반의 재활치료용 신축성 관절센서 개발 (Development of Stretchable Joint Motion Sensor for Rehabilitation based on Silver Nanoparticle Direct Printing)

  • Chae, Woen-Sik;Jung, Jae-Hu
    • 한국운동역학회지
    • /
    • 제31권3호
    • /
    • pp.183-188
    • /
    • 2021
  • Objective: The purpose of this study was to develop a stretchable joint motion sensor that is based on silver nano-particle. Through this sensor, it can be utilized as an equipment for rehabilitation and analyze joint movement. Method: In this study, precursor solution was created, after that, nozel printer (Musashi, Image master 350PC) was used to print on a circuit board. Sourcemeter (Keithley, Keithley-2450) was used in order to evaluate changes of electric resistance as the sensor stretches. In addition, the sensor was attached on center of a knee joint to 2 male adults, and performed knee flexion-extension in order to evaluate accurate analysis; 3 infrared cameras (100 Hz, Motion Master 100, Visol Inc., Korea) were also used to analyze three dimensional movement. Descriptive statistics were suggested for comparing each accuracy of measurement variables of joint motions with the sensor and 3D motions. Results: The change of electric resistance of the sensor indicated multiple of 30 times from initial value in 50% of elongation and the value of electric resistance were distinctively classified by following 10%, 20%, 30%, 40% of elongation respectively. Through using the sensor and 3D camera to analyze movement variable, it showed a resistance of 99% in a knee joint extension, whereas, it indicated about 80% in flexion phase. Conclusion: In this research, the stretchable joint motion sensor was created based on silver nanoparticle that has high conductivity. If the sensor stretches, the distance between nanoparticles recede which lead gradual disconnection of an electric circuit and to have increment of electric resistance. Through evaluating angle of knee joints with observation of sensor's electric resistance, it showed similar a result and propensity from 3D motion analysis. However, unstable electric resistance of the stretchable sensor was observed when it stretches to maximum length, or went through numerous joint movements. Therefore, the sensor need complement that requires stability when it comes to measuring motions in any condition.

Muscle Activity Based on Real-time Visual Feedback Training Methods by Rehabilitative Ultrasound Image in Elderly and Relationship between Heckmatt Scale, Muscle Thickness and Tone : A Pilot Study

  • Shin, Janghoon;Lee, Wanhee
    • Physical Therapy Rehabilitation Science
    • /
    • 제10권1호
    • /
    • pp.82-89
    • /
    • 2021
  • Purpose: This study is to investigate the muscle activity based on real-time visual feedback training methods by rehabilitative ultrasound image in elderly and correlation between Heckmatt scale grade, muscle tone and thickness. Design: Cross-sectional study: Pilot study Methods: 6 elderly participated in the study with 2 conditions. Under the condition of rehabilitation ultrasound imaging equipment, all subjects performed voluntary maximal muscle contraction of the quadriceps 3 times using visual feedback based on Rehabilitative Ultrasound Imaging 1.0 (RUSI 1.0). Under the condition of only ultrasound images, all subjects performed voluntary maximal muscle contraction of the quadriceps 3 times using ultrasound image-based visual feedback. The muscle thickness and tone of the quadriceps were measured and the grades were classified by Heckmatt scale and all variables were comparative analyzed. Results: Heckmatt scale grade showed a negative correlation with muscle thickness at relaxation (p<0.05), and a negative correlation with the difference value obtained by subtracting muscle thickness at relaxation from muscle thickness at contraction in ultrasound image condition (p<0.05). The muscle tone during relaxation showed a negative correlation with the muscle thickness during relaxation (p<0.05). Conclusion: In the case of voluntary maximum muscle contraction of the quadriceps muscle in the elderly, it can be seen that the muscle thickness is getting larger when the RUSI 1.0-based visual feedback is provided than with only ultrasound image provided. And the lower Heckmatt scale grade is, the thicker the muscle is, and the lower the muscle tone is.

한 다리 서기 동안 매끈눈따라보기와 신속눈운동이 균형과 근활성도에 미치는 영향 (The Effects of Smooth Pursuit Eye Movement and Saccadic Eye Movement on Balance and Muscle Activation during One Leg Standing)

  • 정용범;김규령;김명권
    • 대한물리의학회지
    • /
    • 제17권4호
    • /
    • pp.113-121
    • /
    • 2022
  • PURPOSE: This study is examined the effects of vestibular stimulation through eye movement on balance and muscle activity. METHODS: In 42 healthy adults, no eye exercise was applied to both feet and one foot. The speed of smooth pursuit eye movement (.2 Hz, .3 Hz, and .5 Hz) and saccadic eye movement (.5 Hz and 1.1 Hz) were randomized. The measurements were taken three times for 30 seconds while standing on two feet and measured three times for 10 seconds while standing on one foot. The muscle activity measurement equipment was used to measure the electromyogram signals of the tibialis anterior, peroneus longus, gastrocnemius medialis, vastus medialis, vastus lateralis, biceps femoris, abdominal internal oblique, and erector spinae muscle. RESULTS: As a result of this study, when applying smooth pursuit eye movement on one leg, the pressure center movement increased, the muscle activity of the lower extremity increased, in the saccadic eye movement, and the center of pressure decreased. CONCLUSION: Accordingly, the smooth pursuit of eye movement, the intervention of this study, affects balance. Through this, the balance can be improved by applying eye movement to the target who needs to improve the balance ability.

척추재활운동을 위한 디지털 압력바이오피드백 장치의 사용성 평가 (Usability Testing of Digital Pressure Bio-feedback for Spinal Rehabilitation Exercise)

  • 김태호;오도봉;김다연
    • 재활복지공학회논문지
    • /
    • 제11권3호
    • /
    • pp.119-126
    • /
    • 2017
  • 임상현장에서 압력 바이오피드백 장치는 요통 환자들의 척추재활운동에 사용되고 있으나, 여러 가지 단점을 갖고 있다. 본 연구는 사용자에게 신체의 움직임과 균형을 센싱하고 모니터링하여 사용자에게 바이오피드백을 제공함으로써 척추재활운동시 실시간으로 정확한 운동방법과 자세를 제공하는 디지털화된 압력 바이오피드백 장치를 개발하고자 하였다. 그 후 사용성 평가를 진행하여 안전성, 수행성, 조작성, 만족성 등의 문제점을 파악하고 개선방향을 제시하고자 한다. 본 연구에 참여한 대상자는 총 33명으로 전문가 평가 집단 11명, 사용자 평가 집단 22명으로 실제 개발된 장비를 사용 후 5점 척도로 평가하였다. 사용자 집단에서는 안전성 3.59점, 조작성 4.38점, 만족성 4.49점으로 나타났으며, 전문가 집단에서는 안전성 2.86점, 조작성 3.91점, 수행성 4.28점으로 나타났다. 본 사용성 평가를 바탕으로 태블릿PC 거치대의 안정성 문제, 공기주입, 화면 표시 등의 문제점을 개선한다면 척추안정화 운동을 하면서 실시간 자신의 운동상태를 확인하여 정확한 운동과 기능 평가가 가능한 운동장치가 될 것이다.

H 감비탕(GB-001)이 폐경 전·후 비만 여성의 체중감량에 미치는 영향에 대한 후향적 연구 (The Retrospective Analysis of Effects of H Gambitang (GB-001) on Weight Loss in Pre- and Post-Menopausal Obese Woman)

  • 조홍석;서연호;김고운;조재흥;송미연
    • 한방비만학회지
    • /
    • 제20권1호
    • /
    • pp.20-30
    • /
    • 2020
  • Objectives: The purpose of this study is to verify the effects of H Gambitang (GB-001) on body composition and basal metabolic rate in pre- and post-menopausal obese woman retrospectively. Methods: The study was conducted on 57 middle-aged obese women. They were divided into two groups; pre-menopausal obesity group (Pr-MOG; n=34) and post-menopausal obesity group (Po-MOG; amenorrhea was continued to 14~48 month, n=23) with no significant difference of age, height, body weight and body mass index. All subjects took herbal medicine 3 times a day, for 6 weeks during treatment period. The weight, height, body fat mass, skeletal muscle mass, and basal metabolic rate of all subjects were measured on first visit. The following measurements were repeated after 2 weeks (2nd), 4 weeks (3rd) and 6 weeks (4th) with Inbody 370 (Biospace) equipment to identify changes of body fat mass, skeletal muscle mass, and basal metabolic rate. Results are represented as mean and standard deviation. Results: Po-MOG showed significantly lower decrease rate in weight reduction on 2~6 weeks while significantly higher decrease rate in skeletal muscle reduction on 4~6 weeks. There were no significant differences between two groups in body fat reduction rate and basal metabolic increasing rate. Conclusions: H Gambitang (GB-001) can be used not only in Pr-MOG but in Po-MOG in weight loss although the effect can be lower in Po-MOG. To prevent skeletal muscle mass loss in Po-MOG, following study on adjusting dose and components of H Gambitang (GB-001) thought to be necessary.

VR을 이용한 균형능력 측정장비의 성능평가 (Performance Evaluation of Balance Ability Equipment Using VR)

  • 윤상철;안호원;안택원;최해성;이병권;서동권;이규환;정상우;이재훈
    • 대한통합의학회지
    • /
    • 제8권3호
    • /
    • pp.33-41
    • /
    • 2020
  • Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipment that measures the balance of the body using changes in body segment and pressure using the acceleration sensor to compensate for the disadvantages of the existing equipment. Methods : To this end, balance ability was measured in 43 healthy male/female adults without orthopedic injuries and nervous system damage in the last 6 months. in a situation where the visual information was restricted by Virtual Reality (VR) gear, all subjects measured and evaluated the balance ability utilizing the new equipment. Balance measurement (Prime Medilab, Korea) and Wii fit (Nintendo, Japan) were used to measure the balance ability of the subjects, and the balance ability test was performed in 4 postures using each device for data acquisition. The test duration for each posture was 30 seconds. For data acquisition, the average value of three experiments measured using each equipment was analyzed, and the statistical test was performed using the independent sample and the corresponding sample t-test, and the significance level was set to α=.05. Results : As a result of measuring the balance ability using individual equipment, blocking visual information using VR gear, the average speed, maximum speed, and moving area of the COP increased equally. It was found that the obtained absolute size of the result in Wii was somewhat larger than that of BM. Conclusion : It is considered that in the future research, it is necessary to measure changes in the body's center of gravity through image analysis, etc., to make clear comparison and evaluation of the usability.

Development of a Shower Carrier based on the Needs in Long-term Care Institutions

  • Cho, Deok-Yeon;Ko, Cheol-Woong;Chun, Keyoung-Jin;No, Kon-Woo
    • 대한인간공학회지
    • /
    • 제31권2호
    • /
    • pp.379-388
    • /
    • 2012
  • Objective: This study developed a new shower carrier prototype to reduce caregivers' muscle burden and to increase use convenience by reflecting the needs of domestic long-term care institutions. Background: In the long-term care institutions, one of the ADL(Activities of Daily Life) factors is bathing/showering. Recently, bath/shower-assisting equipment is actively being introduced in care institutions to reduce the caregivers' care cost, but most of the domestic equipment was designed to imitate foreign products and rarely reflected the needs of care institutions. Method: Based on Korean elderly people's body information, the bed size(length: 1,900mm, width: 650mm) was set-up, and a variable headrest with a newly designed headform was developed to provide the comfort for the elderly and convenience for caregivers. To reduce caregivers' muscle burden on transferring and showering activities, a 3-step column lifting module equipped with dual actuators(lowest/highest levels from the ground: 600/1,100mm, Stroke: 500mm) was developed, and the wheelbase parameter(length: 1,250mm, width: 580mm) was defined securing the turn-over safety of the shower carrier. The drivability tests were performed for the prototype and foreign product, and the male and female subject's muscle activities were measured through the tests. Results: The structural stability of the shower carrier prototype was secured by finite element analysis, and the muscle activities of the subjects through the drivability tests largely decreased in the prototype, compared to the foreign product. Conclusion: In this study, a new shower carrier prototype was developed to possibly reduce caregivers' muscle burden and to increase use convenience based on the needs of long-term care institutions. It was expected that the drivability performance of the prototype could be relatively superior to that of the foreign product. Application: The results obtained from the study can be applied for the optimal development of a shower carrier including other equipment to effectively care for the elderly.