• Title/Summary/Keyword: regeneration energy

Search Result 356, Processing Time 0.03 seconds

Direction for Development of Energy Regeneration Device for DC Electric Railway System (DC전철구간의 에너지회생장치 개발 방향)

  • Kim, Yong-Ki;Bae, Chang-Han;Han, Moon-Seob;Yang, Young-Chul;Jang, Su-Jin
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.804-808
    • /
    • 2007
  • when electric traction system used DC 1500V runs on decline of rail road track and slows down, Dc voltage goes beyond regular voltage. In this case extra power is forcibly wasted by resister because rectifier of substation and electric train including power converter and so on are out of order. This paper described a DC electric railway system, which can generate the excessive DC power form DC bus line to AC source in substation for traction system. The proposed regeneration inverter system for DC traction can be used as both an inverter and an active power filter(APF). As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. In addition, electric traction system products harmonic current and voltage distortion and reactive power because power converter is used so regeneration inverter normally runs such as active power filter(APF) for improving power quality. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three phase PWM inverters and composed of parallel inverters, output transformers, and an LCL filter.

  • PDF

Development of 3 Phase PWM Converter using Analog Hysteresis Current Controller (아날로그 히스테리시스 전류 제어기를 적용한 3상 PWM 컨버터 개발)

  • Lee Young-kook;Noh Chul-won
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.372-376
    • /
    • 2001
  • Due to several advantages of Pulse Width Modulation(PWM) Converter, such as unity power factor operation, elimination of low-order harmonics and regeneration of motor braking energy to source, the application range of PWM Converter has been rapidly extended in industrial application. Nowadays, vector control algorithm and space vector PWM(SVPWM) method are applied to improve the performances of PWM Converter, but vector control algorithm and SVPWM require to use Microprocessor and other digital devices in hardware, causing costly and somewhat large dimension system. In every practical application of energy conversion equipments, the design and implementation should be carried out considering cost and performance. High performance and low cost is the best choice for energy conversion equipments. So, this paper presents the practical design method and implementation results of 3-phase PWM Converter with analog hysteresis current controller, and verifies the performances of unit power factor operation and energy regeneration operation via experimental results.

  • PDF

EVALUATION OF FERROCYANIDE ANION EXCHANGE RESINS REGARDING THE UPTAKE OF Cs+ IONS AND THEIR REGENERATION

  • Won, Hui-Jun;Moon, Jei-Kwon;Jung, Chong-Hun;Chung, Won-Yang
    • Nuclear Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.489-496
    • /
    • 2008
  • Ferrocyanide-anion exchange resin was prepared and the prepared ion exchange resins were tested on the ability to uptake $Cs^+$ ion. The prepared ion exchange resins were resin-KCoFC, resin-KNiFC, and resin-KCuFC. The three tested ion exchange resins showed ion exchange selectivity on the $Cs^+$ ion of the surrogate soil decontamination solution, and resin-KCoFC showed the best $Cs^+$ ion uptake capability among the tested ion exchange resins. The ion exchange behaviors were explained well by the modified Dubinin-Polanyi equation. A regeneration feasibility study of the spent ion exchange resins was also performed by the successive application of hydrogen peroxide and hydrazine. The desorption of the $Cs^+$ ion from the ion exchange resin satisfied the electroneutrality condition in the oxidation step; the desorption of the $Fe^{2+}$ ion in the reduction step could also be reduced by adding the $K^+$ ion.

A Study on the Regeneration Energy Reduction through the Process Improvement of the Carbon Dioxide Capture Process (상전이 현상을 이용한 이산화탄소 포집공정개선 및 재생에너지 절감에 대한 연구)

  • Kim, Yu-Mi;Kim, Dong-Sun;Cho, Jung-Ho
    • Clean Technology
    • /
    • v.18 no.2
    • /
    • pp.221-225
    • /
    • 2012
  • In this study, simulation works for a carbon dioxide capture process using solvent absorption method have been performed for decrease of regeneration energy in applying phase transition of liquid solvent. When carbon dioxide is dissolved in 30 wt% MEA solvent, liquid mixture divided into two phase according to mole loading of dissolved carbon dioxide. Using this phenomenon, we can decrease regeneration energy about 61% than primary absorber column-stripper column process.

Study on Characteristics of Dryness Storage Tank, Component of open-type Dehumidifying and Drying System using Solar Energy (2nd Paper: Experiment on Influence of Baffle Plates Installed in the Tank) (태양열을 이용한 개방형 제습.건조시스템의 저장탱크 유동특성에 관한 연구(제2보 배플 설치의 영향에 관한 실험))

  • Kim, J.R.;Choi, K.H.;Kum, J.S.;Kim, J.R.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.25-30
    • /
    • 2000
  • The present study has been conducted to offer an geometrically optimal structure of a storage tank for a regenerator. In this paper, three kinds of baffle plates supposed to increase the regeneration rate and classified as "Type A($L^*$=0.25, 80(L)$\times$300(W)$\times$50 (H) [mm])", "Type B($L^*$=0.5, 150(L)$\times$300(W)$\times$50 (H) [mm])", and "Type C($L^*$=0.75, 230(L)$\times$300(W)$\times$50(H) [mm])" were suggested and tested. They were placed between the vertical C-C layers in the tank. Solution temperature and concentration were used to evaluate the regeneration rate. As a result, the regeneration rate was better in "Type C".

  • PDF

Adsorption/desorption of CO2 on Activated Carbon Fibers Using Electric Swing Adsorption (활성탄소섬유상에서 전기변동법을 이용한 CO2의 흡/탈착)

  • Shim, JaeWoon;Moon, SeungHyun
    • Korean Chemical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.432-437
    • /
    • 2005
  • An electric swing adsorption (ESA) process for recovering highly pure $CO_2$ from the mixed gases was tested. In this study, activated carbon fibers were used as an adsorbent. The activated carbon fibers showed fast adsorption rate and the high adsorption capacity for $CO_2$ adsorption under the condition of the ambient pressure. Activated carbon fiber with higher specific surface area was suitable to repeated adsorption-desorption cycle process, showing consistent breakthrough curve. Especially, the regeneration method by vacuum combined with ESA improved the performance of desorption process by an additional 17% regeneration efficiency compared to a vacuum only method, and showed the high regeneration efficiency at comparatively low 7-8 Wh energy.

The Effects of Plant Growth Regulators on Plant Regeneration and Direct Shoots Formation of Petal Explants of Chrysanthemum Flower Color Mutants Varieties, 'ARTI-purple' and 'ARTI-queen' (국화 화색 돌연변이 품종 'ARTI-purple' 및 'ARTI-queen' 꽃잎 조직의 재분화와 신초형성에 미치는 식물생장호르몬의 영향)

  • Lee, Yu-Mi;Kang, Eun Jeong;Sung, Sang Yeop;Kim, Sang Hoon;Ha, Bo-Keun;Kim, Dong Sub;Kim, Jin-Baek;Kang, Si-Yong
    • Horticultural Science & Technology
    • /
    • v.31 no.3
    • /
    • pp.359-365
    • /
    • 2013
  • Chrysanthemum is one of the most popular ornamental plants worldwide. Recently, lots of new and novel chrysanthemum varieties have been developed using mutagenesis. However, there was no study for comparison of tissue culture condition among the mutant varieties derived from one original variety, until now. This study was conducted to compare the efficient regeneration condition of the two chrysanthemum mutant varieties, 'ARTI-purple' and 'ARTI-queen'. Two different flower parts (disk and ray florets) at the unopened and early blooming stages were used for comparison of regeneration condition on MS medium supplemented with combinations of three growth regulators (BA, NAA, and IAA). The highest regeneration rate was identified on the NAA and BA combination when the disk florets at unopened blooming stage are used. The best optimum combinations of growth regulators were identified as NAA $1.0mg{\cdot}L^{-1}$ and BA $0.5mg{\cdot}L^{-1}$ at 'ARTI-purple', which displayed 47.9% regeneration. However, regeneration of 'ARTI-queen' was the highest as 25.6% at NAA $2.0mg{\cdot}L^{-1}$ and BA $1.0mg{\cdot}L^{-1}$. There results indicate that there is a difference for the optimum regeneration condition between the mutant varieties derived from one original variety. These results will be useful for construction of efficient regeneration system of diverse chrysanthemum mutants developed by mutation breeding.