• Title/Summary/Keyword: refrigerant mixture

Search Result 148, Processing Time 0.023 seconds

A Study on Pressure Drop Characteristics of Refrigerant in Heat Exchanger for Automobile (자동차용 열교환기 냉매의 압력 강하 특성에 관한 연구)

  • 임태우;박종운
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.119-125
    • /
    • 2003
  • An experiment study on pressure drop was carried out for both an adiabatic and a diabatic two-phase flow with pure refrigerants R134a and Rl23 and their mixtures as test fluids in a uniformly heated horizontal tube. The frictional pressure drop during flow boiling is predicted by using two models; the homogeneous model that assumes equal phase velocity and the separate flow model that allows a slip velocity between two phases. The measured frictional pressure drop was compared to a few available correlations. Homogeneous model considerally underpredicted the present data for mixture as well as pure component in the entire mass velocity ranges employed in the present study, while Friedel correlation was found to satisfactorily correlate the frictional pressure drop data as compared to other correlation.

Correlations of Oil Concentration Prediction during In-line Flow of $CO_2/Oil$ Mixtures (유동중인 $CO_2$냉매와 오일 혼합물의 농도 예측을 위한 상관식)

  • Park, Keun-Seo;Kang, Byung-Ha;Park, Kyoung-Kuhn;Kim, Suk-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.10
    • /
    • pp.718-725
    • /
    • 2007
  • In the general vapor-compression refrigeration system, refrigeration lubricant circulates in refrigeration system with refrigerant. Knowledge of the amount of circulating lubricant is very important to exactly calculate capacity of the refrigeration system. An experimental study was conducted to estimate the oil concentration of a flowing $CO_2/Oil$ mixtures. POE and PAG oil are considered as test lubricants in this study. Performance tests were conducted under simulated liquid conditions for $CO_2/POE$ oil mixture in oil concentration of 0 to 10 weight-percent and $CO_2/PAG$ oil mixture in oil concentration of 0 to 6 weight-percent in the temperature ranges of $-5^{\circ}C\;to\;15^{\circ}C$. The results obtained indicate specific gravity of $CO_2/Oil$ mixture is increased as oil concentration is increased and as temperature of mixture is decreased. Oil concentration correlation of $CO_2/POE$ oil mixture and $CO_2/PAG$ oil mixture is suggested, based on the measurement of specific gravity and temperature. This correlation enable to predict the oil concentration without extraction of the mixture and can be applied for $CO_2/POE$ mixtures and $CO_2/PAG$ mixtures.

A Feasibility Study on the Mixed Refrigerant Composition in the Rankine Cycle Empowered by Cold Energy (냉열을 이용한 랭킨 사이클 방식의 발전시스템에서 혼합냉매유체 조성비의 적용한계 분석)

  • Jeong, Moon;Cho, Eunbi;Hwang, Inju;Kang, Choonhyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.3
    • /
    • pp.14-18
    • /
    • 2016
  • The power generation system using cold energy, which evolves in a large amount during the vaporization process of the liquefied natural gas, was designed in favor of the Rankine cycle with a mixed refrigerant as the working fluid. In this study it is intended to identify the allowable limits of the working fluid composition in respect of equipment safety in the Rankine cycle-type power generation system driven by the cold energy. The thermodynamic properties of the working fluid, which is a hydrocarbon mixture, were calculated with the Peng-Robinson model. In the steady state simulation of the power generation system by using a commercial tool Aspen HYSYS, the feed conditions of LNG Test Bed Train No.1 along with some necessary assumptions were incorporated. The results indicated that deterioration of the mechanical performance of the equipment as well as its safety would be brought about if contents of $C_2H_6$ and $C_3H_8$ in the mixture become, respectively, too high or too low.

External Condensation Heat Transfer Coefficients of HFC32/HFC152a Mixtures on Enhanced Tubes (열전달 촉진관에서 HFC32/HFC152a 혼합냉매의 외부 응축열전달계수)

  • Lee, Yohan;Kang, Donggyu;Kim, Hyeon-Ju;Lee, Ho-Saeng;Jung, Dongsoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.7
    • /
    • pp.315-321
    • /
    • 2014
  • In this study, external condensation heat transfer coefficients (HTCs) of two non-azeotropic refrigerant mixtures of HFC32/HFC152a at various compositions were measured on both 26 fpi low-fin and Turbo-C enhanced tubes, of 19.0 mm outside diameter. All data were taken at the vapor temperature of $39^{\circ}C$, with a wall subcooling of 3~8 K. Test results showed that the HTCs of the tested mixtures on the enhanced tubes were much lower than the ideal values calculated by mass fraction weighting of the pure component HTCs. Also, the reduction of HTCs due to the diffusion vapor film was much larger than that of a plain tube. Unlike HTCs of pure fluids, HTCs of the mixtures measured on enhanced tubes increased, as the wall subcooling increased, which was due to the sudden break-up of the vapor diffusion film with an increase in wall subcooling. Finally, the heat transfer enhancement ratios for mixtures were found to be much lower, than those of pure fluids.

Effect of Oil on Pool Boiling of Refrigerant on Enhanced Tubes having Different Pore Sizes (다공도가 다른 전열촉진관의 냉매 풀비등에 미치는 오일의 영향)

  • Kim Nae-Huyn;Lee Eung-Ryul;Min Chang-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.254-261
    • /
    • 2006
  • The effect of enhanced geometry (pore diameter, gap width) is investigated on the pool boiling of R-123/oil mixture for the enhanced tubes having pores with connecting gaps. Tubes with different pore diameters (and corresponding gap widths) are specially made. Significant heat transfer degradation by oil is observed for the present enhanced tubes. At 5% oil concentration, the degradation is 26 to 49% for $T_{sat}=4.4^{\circ}C$. The degradation increases 50 to 67% for $T_{sat}=26.7^{\circ}C$. The heat transfer degradation is significant even with small amount of oil (20 to 38% degradation at 1% oil concentration for $T_{sat}=4.4^{\circ}C$), probably due to the accumulation of oil in sub-tunnels. The pore size (or gap width) has a significant effect on the heat transfer degradation. The maximum degradation is observed for $d_p$ = 0.20 mm tube at $T_{sat}=4.4^{\circ}C$, and for $d_p$=0.23 mm tube at $T_{sat}=26.7^{\circ}C$. The minimum degradation is observed for $d_p$=0.27 mm tube for both saturation temperatures. It appears that the oil removal is facilitated for the larger pore diameter (along with larger gap) tube. The highest heat transfer coefficient with oil is obtained for $d_p$ =0.23 mm tube, which yielded the highest heat transfer coefficient for pure R-123. The heat transfer degradation increases as the heat flux decreases.

Characteristics of Nano-Fluid Improvement of Lubrication for Compressor Friction Parts (압축기 습동부 윤활 특성 향상을 위한 나노유체 특성(열전도도, 분산성, 점도변화, 마찰거동))

  • Kim, Jae-uk;Park, Cheol-min;Park, Jung-hack;Park, Sang-ha
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.108-113
    • /
    • 2017
  • The performance of refrigerant oil at the thrust bearing and at the journal bearing of a scroll compressor is a significant factor. This paper presents the friction and anti-wear characteristics of nano-fluid with a mixture of a refrigerant oil and nano powders. The particle size distribution and oxidation stability of nano powders prepared by the electrical explosion method were analyzed by TEM and BET. It was found that the nanoparticles showed a spherical morphology with sizes ranging of 40-60 nm and were covered with graphite layers of 2-4 nm. The thermal conductivity of POE oil was 0.1-0.5W/mk higher than that of POE oil. The coefficient of friction of Cu-POE was found to be 0.1 higher than that of Al2O3. The cooling capacity of the heat pump with nanofluid increased to 3.67%, and the performance was improved by 5.83%.

The Evaporation Flow Patterns and Heat Transfers of R-22 and R-134a in Small Diameter Tubes (세관내 R-22 and R-134a의 증발 유동양식과 열전달)

  • Son, Chang-Hyo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.3
    • /
    • pp.275-283
    • /
    • 2007
  • 본 논문은 세관(ID<7 mm) 내 R-22와 R-134a의 증발 열전달과 유동양식에 대한 실험적 연구이다. R-22와 R-134a의 유동양식을 관찰하기 위해 내경 2와 8 mm의 파이렉스 튜브를 사용하였고, 열전달 계수는 내경 1.77, 3.35, 5.35 mm의 수평 평활동관에 대해서 측정하였다. 증발 유동양식에서 내경 2 mm의 환상류 영역이 내경 8 mm에 비해 저건도 영역에서 발생하는 것을 확인할 수 있었고, 내경 2 mm의 유동양식은 Mandhane의 선도와 많은 오차를 보였다. 세관(ID<7 mm) 내 증발 열전달 계수는 종래의 대구경관(ID>7 mm)에 비해 관직경에 대한 영향이 많이 나타나는 것을 알 수 있었다. 내경 1.77 mm의 열전달 계수는 내경 3.36 mm와 5.35 mm에 비해서 20내지 30% 정도 높은 것을 나타났다. 또한 종래의 열전달 상관식(Shah's, Jung's, Kandlikar's and Oh-Katsuda's correlation)과 비교한 결과, 실험 데이터는 상관식과 많은 이탈 정도를 보였다. 따라서 실험데이타를 기초로 세관내 R-22와 R-134a에 적용할 수 있는 증발 열전달 상관식을 새로이 제안하였다.

Soft ice-cream maker operating with mixed refrigerant R290/R32 (혼합냉매 (R290/R32) 적용 소프트 아이스크림 제조기 (drop-in 시험))

  • Park, Tae-Gyun;Han, Seong-Pil;Lee, Eung-Ryeol;Kim, Nae-Hyeon;Park, Hyeong-Chae
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.410-413
    • /
    • 2005
  • Drop-in tests were conducted using R290/R32 (31:69) mixture in an ice-cream maker for possible replacement of R-502 and R-404A. Optimum refrigerant charge and TEV opening were obtained through a series of experiments. At the standard outdoor condition ($35^{\circ}C$ DT, $24^{\circ}C$ WT), the time required for initial ice-cream making was 6'22", which was approximately the same as that of R-404A. The electric energy consumed was 660 kJ, which was about 10% higher than that of R-404A. The compressor outlet temperature ($8^{\circ}C$) and pressure (2.52 MPa) were higher than those ($60^{\circ}C$ and 1.48 MPa) of R-404A. The reason could be the usage of the same R-404A compressor although the specific volume of R290/R32 is much larger.

  • PDF

Performance Evaluation of Thrust Slide-Bearing of Scroll Compressors under R-22 Environment (R-22 냉매 분위기하에서 스크롤 압축기 스러스트 베어링의 윤활특성 평가)

  • Cho, Sang-Won;Kim, Hong-Seok;Lee, Jae-Keun;Lee, Hyeong-Kook;Lee, Byeong-Chul;Park, Jin-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.590-595
    • /
    • 2006
  • This paper presents the friction and anti-wear characteristics of nano-oil with a mixture of a refrigerant oil and carbon nano-particles in the thrust slide-bearing of scroll compressors. Frictional loss in the thrust slide-bearing occupies a large part of total mechanical loss in scroll compressors. The characteristics of friction and anti-wear using nano-oil are evaluated using the thrust bearing tester for measuring friction surface temperature and the coefficient of friction at the thrust slide-bearing as a function of normal loads up to 4,000 N and orbiting speed up to 3,200 rpm. It is found that the coefficient of friction increases with decreasing orbiting speed and normal force. The friction coefficient of carbon nano-oil is 0.015, while that of pure oil is 0.023 under the conditions of refrigerant gas R-22 at the pressure of 5 bars. It is believed that carbon nano-particles can be coated on the friction surfaces and the interaction of nano-particles between surfaces can be improved the lubrication in the friction surfaces. Carbon nano-oil enhances the characteristics of the anti-wear and friction at the thrust slide-bearing of scroll compressors.

  • PDF

Effect of Outdoor Temperature on the Refrigerant Behavior in the Compressor of a Heat Pump Operating at Heating Mode (열펌프의 난방운전시 외기온이 압측기의 냉매거동에 미치는 영향)

  • 이재효;김병균;이건우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.452-458
    • /
    • 2004
  • The major cause of compressor failure is the decrease of oil viscosity due to floodback. In most previous researches on the compressor reliability, the relationship between oil circulation rate and performance or oil viscosity has been studied. Another research topic is flow visualization by using a sight glass on the bottom of a compressor sump area and accumulator. Both oil film thickness and oil level through the sight glass should be assessed for compressor reliability if the oil content of the mixture is small and low viscosity raise poor lubrication of pump bearing. In this study, the compressor reliability was assessed by measuring the viscosity of the mixture and calculating oil film thickness. The analysis of the relationship between bottom shell super heat and oil film thickness at heating operation was peformed. It is concluded that bottom shell superheat does not perfectly stand for the mixture's behavior for a low ambient heating operation and oil film thickness can give more detailed and direct criteria for compressor reliability.