• Title/Summary/Keyword: refractometer

Search Result 75, Processing Time 0.027 seconds

A study on the brilliance by critical angle of gem and measurement theory of refractive index using refractometer (보석의 임계각에 따른 휘광성 및 굴절계를 이용한 굴절률 측정 이론에 관한 연구)

  • Moon, So-I;Seok, Jeong-Won
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.21 no.3
    • /
    • pp.105-109
    • /
    • 2011
  • Critical angle of quartz (R.I. ${\fallingdotseq}$ 1.553) and diamond (R.I. = 2.417) are $40.09^{\circ}$ and $24.26^{\circ}$ that calculated by $sin{\theta}=r_2/r_1$ (r = refractive index, $r_1$ > $r_2$). Brilliance of quartz and diamond are 20.33% and 55.07%. The brilliance data are result of study on the incident light internal round brilliant cut quartz and diamond by the critical angle. Cause of bow-tie phenomenon can be studied by application of critical angle theory and light path inside fancy shape brilliant cut. When refractormetry with typical gem refractometer, critical angle of quartz and corundum are $59.1^{\circ}$ and $77.9^{\circ}$.

Comparison of Accommodative Response among Emmetropes, Spectacle and Contact Lens Wearer (정시, 안경 및 콘택트렌즈 착용자의 조절반응량 비교)

  • Lee, Kyu-Byung;Park, Jeehyun;Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.403-410
    • /
    • 2012
  • Purpose: The purposes of this study are to investigate accommodative response among emmetropes, spectacle wearer and contact lens wearer, and correlation between refractive error and accommodative respons for each group. Methods: The 72 subjects(144 eyes) who do not have any ocular diseases were participate in this study. Subjects were categorized into emmetropes, spectacle wearer and contact lens wearer by refractive error using closed-field auto-refractometer. We measured dominant eye, naked/habitual visual acuity and refractive error of monocular/binocular vision of refractive error for far/near distance with open-field auto-refractometer and calculated accommodative lag. Results: There were no significant difference of accommodative lag between right and left eye dominant and non-dominant eye, monocular and binocular vision, and spectacle lens wearer and contact lens wearer, However the accommodative lag of binocular vision was severe than monocular vision at near. The lag of myopia was larger than emmetropes, and male was larger than female. Significant correlation was found between refractive error and accommodative lag in total subjects and the same result was found in emmetropes and contact lens wearer. However there were no significant correlation in the spectacle wearer. Conclusions: There were significant difference between emmetrops and myopes in terms of accommodative lag, however accommodative lag of spectacle wearer was not different with contact lens wearer in myopes. There were also significant correlation between refractive error and accommodative lag in emmetropes and contact lens wearer, but the accommodative lag of spectacle wearer was not significantly correlated with refractive error.

Glucose Monitoring Device in Textile Processing (섬유공정 응용의 연속식 당 모니터링 장치 개발)

  • 이명희;최은경;정진갑
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2001.10a
    • /
    • pp.379-381
    • /
    • 2001
  • 굴절율 측정에 의하여 당 성분을 정량하는 방법을 이용한 장치로, 글루코오스의 환원성에 기초하여 산화ㆍ환원 반응을 이용한 적정법이나 흡광도 측정법과 비교하여 시약이 필요없고 시간이 단축되는 장점이 있다. 그리고, 보통의 굴절율 측정기(예로 Abbe refractometer)가 당 농도 0.5%일 때의 굴절율 값 단위로 측정되는 한계를 극복하여 본 당 모니터링 장치는 바탕 물질과의 굴절율 차이를 증폭한 값으로 data(differential refractive index)를 얻을수 있으므로 글루코오스 농도 0.01% 단위까지 정량할 수 있어서 0.1% 이하의 저농도도 측정 가능하며 그 이상의 농도 범위에서도 측정 오차를 줄일수 있는 장점이 있다. (중략)

  • PDF

The optical properties on the human model eye (모형 안의 광학적 성능)

  • Lim, Hyeonseon;Ji, Taeksang;Kim, Bonghwan;Kim, Sejin;Yoon, Sungro
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.203-207
    • /
    • 2002
  • In this study, by using the eye model of NAVARRO, KOOIJMAN, MAHKICHOONG, the properties of optical system are reserched in a finite ray tracing method, when ametropia is corrected by glasses or contact lens, this study is useful as a reference. Also, when Auto-refractometer for refraction test and Keratomeler are designed, these eye models can be used.

  • PDF

Near Infrared Reflectance Spectroscopy for Non-Invasive Measuring of Internal Quality of Apple Fruit

  • Sohn, Mi-Ryeong;Park, Woo-Churl;Cho, Rae-Kwang
    • Near Infrared Analysis
    • /
    • v.1 no.1
    • /
    • pp.27-30
    • /
    • 2000
  • In this study, we investigated the feasibility of non-destructive determination of internal quality factors of Fuji apple fruit using near infrared(NIR) reflectance spectroscopy and developed the calibration models. As the reference methods, refractometer, titration and texture analyzer for sugar content, acidity and firmness were used, respectively. Samples were scanned from 1100∼2500nm with InfraAlyzer 500C spectrometer and SESAME software was used for data analysis. A multiple linear regression(MLR) analysis was performed to develop the calibrations. The correlation coefficient(R) and standard error of prediction(SEP) were as follows; 0.91, 0.41$^{\circ}$Brix for sugar content, 0.90, 0.04% for acidity and 0.84, 0.094 kg for firmness, respectively. This study shows that NIR spectroscopy can be used to evaluate the sugar content acidity and firmness of apple fruit with acceptable accuracy.

Studies on the Constituents of Korean Edible Oils and Fats - Part 5 : Analysis of Fatty acids in sesame and perilla oil by High Performance Liquid Chromatography (한국산 식물식용유지의 성분에 관한 연구 - 제 5 보- : -High Performance Liquid Chromatography에 의한 참깨와 들깨종자중의 지방산 분석 -)

  • Hwang, Sung-Za;Ko, Young-Su
    • Journal of Nutrition and Health
    • /
    • v.15 no.1
    • /
    • pp.15-21
    • /
    • 1982
  • In this work, the quantitative estimation of fatty acids in sesame and perilla oil by high performance liquid chromatography (HPLC) was investigated. The analysis of fatty acids were separated by HPLC using a differential refractometer as a detector. With micro Bondapak $C_{18}FFAA$ column and acetonitril, chloroform and tetrahydrofuran mixture as a solvent. In the fatty acid compositions, sesame oil was composed mainly of linoleic and oleic acids 49.6 % and 34.7%. In perilla oil, the amounts of oleic, linoleic and linolenic acids were 13.6%, 14.5% and 63.8%, respectively.

  • PDF

Properties of Urea-Formaldehyde Resin Adhesives with Different Formaldehyde to Urea Mole Ratios

  • Park, Byung-Dae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.67-75
    • /
    • 2007
  • As a part of abating the formaldehyde emission of urea-formaldehyde (UF) resin adhesive by lowering formaldehyde to urea (F/U) mole ratio, this study was conducted to investigate properties of UF resin adhesive with different F/U mole ratios. UF resin adhesives were synthesized at different F/U mole ratios of 1.6, 1.4, 1.2, and 1.0. Properties of UF resin adhesives measured were non-volatile solids content, pH level, viscosity, water tolerance, specific gravity, gel time and free formaldehyde content. In addition, a linear relationship between non-volatile solids content and sucrose concentration measured by a refractometer was established for a faster determination of the non-volatile solids content of UF resin. As F/U mole ratio was lowered, non-volatile solids content, pH, specific gravity, water tolerance, and gel time increased while free formaldehyde content and viscosity were decreased. These results suggested that the amount of free formaldehyde strongly affected the reactivity of UF resin. Lowering F/U mole ratio of UF resin as a way of abating formaldehyde emission consequently requires improving its reactivity.

The hardware design of Automatic Refractometer-Keratometer (자동 시각 굴절력-곡률계의 전자 부문 하드웨어 설계)

  • 박춘자;유강민;유대상;박종원
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.10c
    • /
    • pp.49-51
    • /
    • 2001
  • 현재 국내의 시각 관련 전문가들이 일반적으로 사용하는 자동 시각 굴절력-곡률계(Auto Ref-Keratometer)는 대부분 일본 제품들을 포함하는 외국산들이다. 최근 국내에서도 일부 기업에서 시각 측정기 부문에서의 개발을 행하고 있으나 아직 외국 제품들에는 정확도, 성능 등에서 크게 미흡한 수준을 보이고 있다 이에 좀 더 개선된 성능의 광학 부문, 소프트웨어 부문, 전자 하드웨어 부문등이 요구되고 있다. 이에 본 연구에서는 하드웨어의 변경 없이 전자 부문 소프트웨어의 다양한 변경을 가할 수 있도록 해 주어 개발 기간을 크게 줄일 수 있고 고객 데이터베이스 구축 등의 응용 확장도 가능하도록 범용성을 갖추 자동 시각 굴절력 곡률계의 전자 부문 하드웨어를 설계하였다. 본 전자 부문 하드웨어 시스템은 동시 개발 중인 광학 부문, 전자 부문 소프트웨어와 연동되어 외국 제품에 비교시 정확도와 성능면에서 근소하나마 향상된 결과를 낼 수 있게 하였을 뿐 아니라 향후 발전 가능성도 크게 향상시킬 수 있었다.

  • PDF

A Study of Accommodative Response on Emmetropia (정시안의 조절반응량에 관한 연구)

  • Shim, Hyun-Seog;Shim, Moon-Sik;Joo, Seog-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.187-192
    • /
    • 2006
  • The purpose of this research was to measurement real accmmnodative response amount of emmetropia using both eyes open-view auto-refractometer. We classified 377(male 146, female 231)eyes showing good naked vision at least 1.0, with a spherical equivalent refraction of under ${\pm}0.50D$ and cylindercal refraction of under -0.75D, from 10 to 59(mean $25.8{\pm}12.4$) years into 5 groups with 10 year interval and analyzed change of the near astigmatism and accommodative response amount to distinction of age. Age comparison, total mean 1.47D, 10 years age group 1.63D, 20 years age group 1.57D, 30 years age group 1.71D, 40 years age group 0.97D, and 50 years age group 0.05D. It was no difference between 10 to 30 years age group, But it showed the decre8.se which is remarkable from above 40 years age group and it does not almost response from above 50 years age group. Sexual difference, the man appeared some highly in male(mean $26.4{\pm}12.3$ years) 1.56D m female(mean $26.4{\pm}12.3$) 1.43D. Near-astigmatism power change, mean +0.12D, 10 years age group +0.06D, 20 years age group +0.16D, 30 years age group +0.09D, 40 years age group +0.05D, and 50 years age group +0,06D. No significant difference of astigmatism powers among the an groups, but from all years age group the astigmatism power appeared more highly far-astigmatism than near-astigmatism. Near-astigmatism axis change in the far-astigmatism changes at under ${\pm}10^{\circ}$ 103 eyes, above ${\pm}10^{\circ}$ rotation clockwise direction 108 eyes, above ${\pm}10^{\circ}$ rotation counter-clockwise direction 101 eyes. It was analyzed near-astigmatism axis change.

  • PDF