Refractive Error Shift in Nuclear, Cortical, and Subcapsular Cataract (핵, 피질 그리고 낭 백내장의 굴절이상 전환)

  • Park, Sang-Chul;Lee, Soek-Ju;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.41-45
    • /
    • 2003
  • The researchers have studied on the effect of three main morphological types(nuclear, cortical, and subcapsular cataract) of age related cataract on refractive error. We also identified that spherical and cylinderical shift in each type of morphological cataract accoding to their locations and effect of intraocular pressure before and after cataract surgery. Nuclear cataract showed myopic shift while cortical cataract showed hyperopic shift, and subcapsular cataract showed not significant changes on both direction. Age related cataract subjects(120 eyes) only were recruited from sun-cheon area. We use optic section of slit lamp biomicroscope to identify the anatomical location of cataract, and optimal refractive correction determined by objective(retinoscope) and subjective refraction then spherical changes were calculated from the spherical eqivalent value. Intra-ocular pressure were measured by auto-tonometer before and 7 days after cataract has been replaced by IOL. The change in cylindrical power, usually A-P diameter decreased according to increases of age, A-P diameter increased because intra-ocular pressure rises by progression of cataract and this convertion with the rule astigmatism to against the rule astigmatism and this increases more by intra-ocular pressure.

  • PDF

The Need for Change of Korean Optician(optometrist) System (안경사제도의 변화 필요성에 대하여)

  • Seo, Jae-Myoung;Kim, Jae-Do;Kim, Heung-Soo;Shim, Hyun-Suk;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.527-536
    • /
    • 2015
  • Purpose: In this paper, we have dealt with problems and improvement of korean optician system. Methods: Using the relevant material of korean optician system and international optometrist system, provides the theoretical basis of the need for regulatory changes optician. Results: The people with refractive errors are increasing, 67% of refractive error test is made from optical shop and korean optician are sufficient trained, many opticians are in charge of the refractive error test at the ophthalmic hospital. We have confirmed that current law does not reflect adequately the nature of optician's work. Conclusions: Since current capacity of the Korean opticians and education system ready to provide health services for people, therefore an korean optician must redefine the law to fit the reality.

The Study on Relationship of Amblyopia and Astigmatism (약시와 난시와의 관계 연구)

  • Park, Hyun-Ju;Lee, Seok-Ju;Yim, Tae-Jun;Kim, Jai-Min;Lee, Ki-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.391-396
    • /
    • 2004
  • For the prevention of amblyopia, early discover and treatment is very important. Therefore we evaluated the type and the degree of refractive errors of 39 children with anisometropic and refractive amblyopia aged 3 to 12 years, and studied the relationship of astigmatism and amblyopia. Astigmatism was found in 35 of 39 eyes. Of these 35 eyes, with the rule astigmatism was found in 30 eyes. The cylinderical power was distributed mostly from 0.50D to 6.50D and astigmatism did not appear to influence on the initial and final corrected visual acuity.

  • PDF

Ablation Depth of Cornea and Munnerlyn Formula in Refractive Keratectomy (각막굴절교정절제술에서 각막의 절제 깊이와 Munnerlyn 식)

  • Choi, Woon Sang;Kim, Yoon-Kyung;Lee, Sung Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.121-124
    • /
    • 2007
  • Ablation depth of cornea in refractive keratectomy was calculated by Munnerlyn formula. The calculations were preformed for various optical diameter (4 mm~8 mm) and various amount of corrections (-1 Dptr ~ -12 Dptr). The results to be compared with the Munnerlyn approximated formula had little effect within lower corrections, but in higher corrections > 6 Dptr can be occurred the error of 1 Dptr. Although ablation depth were evaluated, the results were only calculated by mathematical model of geometric assumptions. Because ablation depth can vary with operation conditions, the correction factor should be considered not only ablation depth by Munnerlyn formula but also surgeon-specific factor.

  • PDF

The Comparasion of the Dynamic Stereoacuity with Two-Rods Test and Three-Rods Test (이간계와 삼간계를 이용한 동적 입체시의 비교)

  • Shim, Hyun-Suk;Kim, Sang-Moon;Kim, Sang-Hyun;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.377-384
    • /
    • 2015
  • Purpose: On this study, we measured and compared the dynamic stereoacuity by two-rods test (Howard-Dolman Test) and three-rods test. And we analyzed the correlation between PD and refractive error with dynamic stereoacuity. Methods: Dynamic stereoacuity of two-rods test and three-rods test at 2.5 m distance for 93 adults 93 (50 males, 43 females), mean age of $21.27{\pm}2.32$ (19~32) years old, were measured 5 times for two tests. Results: The mean of dynamic stereoacuity measured by two-rods test and three-rods test were $29.91{\pm}23.03sec$ of arc and $23.75{\pm}21.65sec$ of arc for total subjects, respectively. The mean of male and female were $36{\pm}22.38sec$ of arc and $22.28{\pm}23.79$, respectively. Three-rods test showed better dynamic stereoacuity than two-rods test, but there was no statistically significant difference (p>0.05). For the average standard deviation of PD between 60.63 mm~66.19 mm, dynamic stereoacuity fo two-rod test and three-rod test were $31.48{\pm}24.87sec$ of arc and $31.48{\pm}24.87sec$ of arc, respectively. The results showed statistically significant difference (p<0.05), but the relationship between dynamic stereoacuity and PD was not great. Comparison between two tests on the basis of refractive error, dynamic stereoacuity by three-rods test was better than by two-rods test with no significant difference between both tests (p>0.05) and there was little correlation between refractive error and two dynamic stereoacuity. Conclusions: Three-rods test showing lower stereoacuity than two-rods tests could measure the lower minimum threshold of dynamic stereoacuity. It was found that both tests can be applied to dynamic stereoacuity test as a standard test, and PD and refractive error was found that little effect upon the dynamic stereoacuity. PD and refractive error was found that little effect upon the dynamic stereoacuity.

Analysis of Refractive Errors of the before and after Cataract Surgery by Auto-refractor (안굴절계를 이용한 백내장 수술전후의 굴절이상 분석)

  • Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.3
    • /
    • pp.65-69
    • /
    • 2016
  • We investigated refractive errors and corneal power with 3 factors such as M, $J_0$, and $J_{45}$ as power vector to find out the changes of refractive errors of the before and after cataract surgery in 119 adults aged 45~85 years with cataract. After the surgery, the 3 factors were changed as $-0.29{\pm}2.38D$ to $-0.18{\pm}0.69D$ in spherical equivalent power which is the M factor, $-0.34{\pm}0.68D$ to $-0.05{\pm}0.42D$ in the $J_0$ factor, and $0.11{\pm}0.45$ to $0.02{\pm}0.17$ in the $J_{45}$ factor. Before and after the surgery, corneal mean refractive power, $J_0$, and $J_{45}$ were changed from $44.11{\pm}1.61D$ to $44.20{\pm}1.58D$, $0.01{\pm}0.50D$ to $0.08{\pm}0.49D$, and $0.02{\pm}0.29$ to $0.08{\pm}0.49$, respectively. The results showed that $J_0$ was the highest relativeness in correlation of the pre- and post-surgery for refractive errors, mean corneal power was the highest correlation for corneal power factor, and corneal power factor was the higher correlation much more than refractive error factor.

Analysis of Astigmatism in Korean Adults from 20 to 29 Yesrs Old (20세부터 29세까지 한국인 성인 난시 분석)

  • Kim, Douk-Hoon;Park, Sang-Youl
    • Journal of Korean Clinical Health Science
    • /
    • v.9 no.1
    • /
    • pp.1478-1485
    • /
    • 2021
  • Purpose. To analysis of astigmatism in Korean adults from 20 to 29 years old. Methods. From January 2019 to February 2020, one hundred two subjects were performed in refraction test using the Auto-Refractometry. Results. In the type of astigmatism based on refractive error, the male's right eye was 4.26% simple myopic astigmatism and 95.74% complex myopic astigmatism, and the left eye was 2.22% simple myopic astigmatism and 97.78% complex myopic astigmatism. However, in the female's right eye, simple myopic astigmatism was 2.27%, complex myopic astigmatism was 97.73%, and left eye was simple myopic astigmatism was 2.17%, complex myopic astigmatism was 97.83%. The types of astigmatism in men and women similar to other. The mean refractive astigmatism values were -0.922±-0.798 diopter and -0.877±-0.707 diopter for male right and left eye, and -0.765±-0.599 diopter and -0.853±-0.586 diopter for female. On the other hand, the refraction values of the right and left eyes of men and women have statistical significance(p=0.000). The mean power comparative between refractive astigmatism and corneal astigmatism power were -0.186±-0.745 diopter, -1.091±-0.589 diopter in male and -1.140±-0.593 diopter, -1.140±-0.534 diopter in female. Therefore, the mean power values of the refractive astigmatism and corneal astigmatism of men and women were statistical significance(p=0.000). At the 0.75 diopter or more, which can have clinical symptoms of astigmatism power, males have 60.86% and 72.09% of the right and left eyes, and females have 47,64% and 60.10% of the right and left eyes. At 0.75 diopter or more, which can have clinical symptoms of corneal astigmatism power, males have 68.75% and 74% of the right and left eyes, and females have 86.50% and 82.35% of the right and left eyes. In the type of astigmatism axis, both men and women had a high frequency of the rule astigmatism. However, men had a high frequency of against-the-rule astigmatism and women showed a high frequency of oblique astigmatism. Conclusions. In this study, the complex myopic astigmatism and with-the rule astigmatism was the most common of all subjects. However, there was a statistical significance between right and left eyes of all subjects. The corneal astigmatism was higher refractive values in both males and females than refractive astigmatism. This study suggests that the analysis of the astigmatism can provide the useful diagnosis information for the correction of visual acuity.

Study on Manufacturing Aspheric Lens Array with High NA using Reflow Phenomenon (리플로우 현상을 이용한 고 개구수를 갖는 비구면 렌즈 어레이의 제작에 관한 연구)

  • 김완진;이명복;손진승;박노철;박영필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.644-647
    • /
    • 2003
  • Resulting from reproducibility and possibility of mass production. many researches to fabricate micro lens array using lithography have been developed. However, it still remains the level of fabricating compensation lens. Therefore, to realize the fabrication of lens having high numerical aperture can be the key technology of ultra slim optical system. Reflow phenomenon have been researched to make lens having high refractive power. And through those researches, the possibility to fabrication of high refractive power lens has been investigated. In this paper, we analyze the effect of many parameters in reflow process to get an aspheric shape with high repeatability. And we make possible to estimate shape error, through we give direct information about decrease in volume of photoresist.

  • PDF

Liquid Immersion Method for Determining the Refractive Index of a Lens by using the Murty Shearing Interferometer (층밀리기 간섭계를 이용한 렌즈 굴절률의 비파괴적 측정)

  • 이윤우;조현모;이인원
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.7-12
    • /
    • 1991
  • A nondestructive technique for measuring the refractive index of a simple lens is described. The shearing interferornetric technique is used for determining the focal length of a lens by immersing it in various liquids. The lens itself acts as autocollimator and decollimator. An equation for the defocusing error has been theoretically deduced and experimentally verified. The wave aberration has also been investigated for the different values of the focal length.

  • PDF

Development and Effects of Social Learning Theory Based Eye-Health Program for Preschoolers (학령전기 아동을 위한 사회학습이론 기반 눈건강프로그램의 개발과 효과)

  • Lee, Sunghwa;Lee, Haejung;Seo, Hyungsik;Jung, Jaeho
    • Journal of Korean Academy of Nursing
    • /
    • v.48 no.4
    • /
    • pp.407-418
    • /
    • 2018
  • Purpose: The purpose of this study was to develop an eye-health program based on social learning theory (EPST) of preschoolers and evaluate its effectiveness. Methods: A nonequivalent control group pre-post test design was utilized and 141 six-year-old preschoolers and their parents participated (experimental group=69, control group=72) in the study. The EPST in this study included eye-health education and eye exercises. Attention, memory, replay, motivation, reinforcement, and self-efficacy were used as interventional strategies. To examine the effectiveness of EPST, proficiency in eye-health activities, refractive power, and visual acuity were measured before and after the intervention. Data were analyzed with SPSS WIN 21.0 using the Shapiro-Wilk test, ${\chi}^2$-test, Mann-Whitney U test and Wilcoxon signed rank test. Results: Following the intervention, eye-health activities, refractive power, and visual acuity significantly improved in the experimental group compared to the control group. Conclusion: The results of this study suggest that EPST is effective in improving eye-health activities, refractive power, and visual acuity in preschoolers, and its wider implementation in educational institutions will promise improved eye-health among preschoolers.