• Title/Summary/Keyword: reference voltage test

Search Result 96, Processing Time 0.02 seconds

Characteristics Test and Model Parameter Determination of Generator/Excitation System of Yeongdong Unit 1 due to Conversion of Renewable Generation Fuel (신재생 발전 연료전환에 따른 영동1호기 발전기/제어계 특성시험 및 모델정수 도출)

  • Mun, Jeong-Min;Lee, Tae-kyu;Shin, Woo-Ju;Kim, Jeong-Uk
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.586-593
    • /
    • 2019
  • In this paper, we introduce the wood pellet electric power generation system, which is an eco - friendly solid fuel processed pure wood, which is one of the largest capacity renewable power fuels in Korea, The Ministry of Commerce, Industry and Energy notified the Ministry of Land, Infrastructure, Transport and Tourism of the Ministry of Land, Transport and Maritime Affairs of the Ministry of Land, Transport and Maritime Affairs. Derived and validated. It is confirmed that the performance of the generator and the voltage control characteristics of excitation system are good even for the change of generator fuel. It can contribute to future reference at the plant that wants to replace fossil fuels with renewable fuels.

A Study of Shelf Life about Li-ion Battery (리튬 2차 전지의 저장 수명에 관한 연구)

  • Kim, Dong-seong;Jin, Hong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.339-345
    • /
    • 2020
  • In the field of defense, one-shot devices such as missiles are stored for a long period of time after they are manufactured, so it is essential to predict their storage life. A study was conducted to find the shelf life of a Li-ion battery used in one-shot devices. To do this, a Li-ion battery that has been used in weapon systems for more than 5 years was secured. A non-functional test was performed on the battery to check for external changes or failures. After the non-functional test, a discharge test was performed to measure the performance after storing it. Through the test, the performance was checked, including the initial charging voltage, discharge time, and battery temperature, and the trend of the change was identified. An F-test, One-way ANOVA, and regression analysis were performed to verify the aging, and the shelf life of the battery was estimated by an approximation formula that was derived through a regression analysis. As a result of the ANOVA, the p-value was less than the reference value of 0.05, and the performance of the battery decreased by more than 15% after a certain period of time. This change is assumed to result from the change in physical properties of the lithium polymer cell.

Enhancement of Electrical Properties of Organic Light-Emitting Diodes Using F4-TCNQ Molecule as a Hole-Transport Layer (F4-TCNQ 분자를 정공 수송층에 이용한 유기 발광 소자의 전기적 특성 향상)

  • Na, Su Hwan;Lee, Won Jae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.11
    • /
    • pp.717-721
    • /
    • 2017
  • We studied the performance enhancement of organic light-emitting diodes (OLEDs) using 2,3,5,6-fluoro-7,7,8,8-tetracyanoquinodimethane ($F_4-TCNQ$) as the hole-transport layer. To investigate how $F_4-TCNQ$ affects the device performance, we fabricated a reference device in an ITO (170 nm)/TPD(40 nm)/$Alq_3$(60 nm)/LiF(0.5 nm)/Al(100 nm) structure. Several types of test devices were manufactured by either doping the $F_4-TCNQ$ in the TPD layer or forming a separate $F_4-TCNQ$ layer between the ITO anode and TPD layer. N,N'-diphenyl-N,N'-di(m-tolyl)-benzidine (TPD), tri(8-hydroxyquinoline) aluminum ($Alq_3$), and $F_4-TCNQ$ layers were formed by thermal evaporation at a pressure of $10_{-6}$ torr. The deposition rate was $1.0-1.5{\AA}/s$ for TPD and $Alq_3$. The LiF was subsequently thermally evaporated at a deposition rate of $0.2{\AA}/s$. The performance of the OLEDs was considered with respect to the turn-on voltage, luminance, and current efficiency. It was found that the use of $F_4-TCNQ$ in OLEDs enhances the performance of the device. In particular, the use of a separate layer of $F_4-TCNQ$ realizes better device performance than other types of OLEDs.

Development of Outboard Type Contactless Rudder Sensor and Automatic Steering System (선외기 선박용 비접촉 러더센서 및 자동조향장치 개발)

  • Kim, Ho-Young;Bang, Junho;Kim, Tae-Hyung;Ryu, In-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1285-1290
    • /
    • 2017
  • In this paper, we developed a core module of the steering system to control and operate the outboard ship with the automatic steering system, and implemented it as a complete integrated system. In particular, this paper presents the problem of the rudder sensor used in the existing system and implements the contactless rudder sensor as an improvement. In the case of existing rudder sensors, there is a problem that safety operation and economic loss of the ship operation is caused by malfunction due to immersion during use in outboard vessels. However, the proposed rudder sensor is separated from the rotary shaft to constitute a contactless type, and a circular magnet is fixed so that the rotating value can be detected and used by the Hall sensor to completely solve the flooding problem. As a result of the characteristic test, the voltage value from 1.8V to 3.2V was obtained between $-35^{\circ}$ and $+35^{\circ}$ degrees and satisfied the reference value. The proposed rudder sensor was mounted on the outboard ship, and all the performance of controller system were checked. According to the system proposed in this paper, it satisfies the Korean Standard Specification, which defines the speed of convergence in 30 seconds by switching from left to right in 7 seconds. We also confirmed that automatic steering was performed by comparing the compass sensor with the destination in the integrated controller at the start-up.

Analysis of CT Image Quality Change according to Clinical Application Shielding Materials (임상 적용 차폐물질에 따른 선량 및 CT 화질 변화 분석)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.215-221
    • /
    • 2023
  • Among brain CT scan conditions including the lens, the tube voltage was changed to 80, 100, and 120 kVp and applied. The change in dose was analyzed using lead, lead goggles and barium sulfate silicon shielding materials, and the degree of influence of the shielding materials on image quality was compared and analyzed by applying the SNR, CNR, and SSIM index analysis methods. As a result, it was analyzed that although the dose was reduced by applying all shielding materials, the difference in dose reduction was not large (P > 0.05). In addition, as for the change in image quality due to the application of the shielding material, SNR and CNR were the highest when lead goggles were applied, and the structural similarity was measured to be the best as it was closest to the reference value of 1 in SSIM analysis. Therefore, based on the results of this study, it is thought that if more diverse shielding materials and clinical test results are derived and applied, it will be helpful for the clinical application criteria in the case of shielding utilization inspection.

Evaluation for Optimization of CT Dose Reduction Methods in PET/CT (PET/CT 검사 시 CT 피폭선량 감소 방법들의 최적화 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.55-62
    • /
    • 2015
  • Purpose Various methods for reducing radiation exposure have been continuously being developed. The aim of this study is to evaluate effectiveness of dose reduction, image quality and PET SUV changes by applying combination of automatic exposure dose(AEC), automated dose-optimized selection of X-ray tube voltage(CAREkV) and sinogram affirmed iterative reconstruction(SAFIRE) which can be controled by user. Materials and Methods Torso, AAPM CT performance and IEC body phantom images were acquired using biograph mCT64, (Siemens, Germany) PET/CT scanner. Standard CT condition was 120 kV, 40 mAs. Radiation exposure and noise were evaluated by applying AEC, CAREkV(120 kV, 40 mAs) and SAFIRE(120 kV, 25 mAs) with torso phantom compare to standard CT condition. And torso, AAPM and IEC phantom images were acquired with combination of 3 methods in condition of 120 kV, 25 mAs to evaluate radiation exposure, noise, spatial resolution and SUV changes. Results When applying AEC, CTDIvol and DLP were decreased by 50.52% and 50.62% compare to images which is not applying AEC. mAs was increased by 61.5% to compensate image quality according to decreasing 20 kV when applying CAREkV. However, CTDIvol and DLP were decreased by 6.2% and 5.5%. When reference mAs was the lower and strength was the higher, reduction of radiation exposure rate was the bigger. Mean SD and DLP were decreased by 2.2% and 38% when applying SAFIRE even though mAs was decreased by 37.5%(from 40 mAs to 25 mAs). Combination of 3 methods test, SD decreased by 5.17% and there was no significant differences in spatial resolution. And mean SD and DLP were decreased by 6.7% and 36.9% compare to 120 kV, 40 mAs with AEC. For SUV test, there was no statistical differences(P>0.05). Conclusion Combination of 3 methods shows dose reduction effect without degrading image quality and SUV changes. To reduce radiation exposure in PET/CT study, continuous effort is needed by optimizing various dose reduction methods.

  • PDF