• Title/Summary/Keyword: reference sample

Search Result 862, Processing Time 0.028 seconds

Scalable Extension of HEVC for Flexible High-Quality Digital Video Content Services

  • Lee, Hahyun;Kang, Jung Won;Lee, Jinho;Choi, Jin Soo;Kim, Jinwoong;Sim, Donggyu
    • ETRI Journal
    • /
    • v.35 no.6
    • /
    • pp.990-1000
    • /
    • 2013
  • This paper describes the scalable extension of High Efficiency Video Coding (HEVC) to provide flexible high-quality digital video content services. The proposed scalable codec is designed on multi-loop decoding architecture to support inter-layer sample prediction and inter-layer motion parameter prediction. Inter-layer sample prediction is enabled by inserting the reconstructed picture of the reference layer (RL) into the decoded picture buffer of the enhancement layer (EL). To reduce the motion parameter redundancies between layers, the motion parameter of the RL is used as one of the candidates in merge mode and motion vector prediction in the EL. The proposed scalable extension can support scalabilities with minimum changes to the HEVC and provide average Bj${\o}$ntegaard delta bitrate gains of about 24% for spatial scalability and of about 21% for SNR scalability compared to simulcast coding with HEVC.

Color Determination of Beef Rib Eye Using Near Infrared Spectroscopy

  • Kang, J.O.;Park, J.Y.;Choy, Y.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.2
    • /
    • pp.263-267
    • /
    • 2001
  • Beef samples of loin eye area from New Zealand, USA and three quality grades of Hanwoo were analyzed using near infrared spectrophotometer with reference values from laboratory optical Chromameter to determine effective spectrum range and mathematical treatment for determination of color values. $R^2s$ of prediction models were not improved much by calibrating with whole light range (400~2500 nm) compared to using visible range (400~1100 nm). Standard errors of calibration and prediction were influenced by possible bias due to sampling non-homogeneous sample sources. However, partial differentiation in the first order was more stable against sampling biases than second derivatives of the spectra. Lightness value was little different among the five sample sources of beef. Beef samples from USA were brighter and more reddish than beefs of Hanwoo or from New Zealand (p<0.05). Yellowness of USA beef was the highest followed by beef from New Zealand, which was also higher than Hanwoo beefs of three quality grades (p<0.05).

A Study on the Neutron Activation Analysis for the Determination of Mercury in Biological Samples (생체시료중 수은의 정량을 위한 중성자 방사화분석에 관한 연구)

  • Lee Chul;Kim, Nak Bae;Lee Ihn Chong
    • Journal of the Korean Chemical Society
    • /
    • v.19 no.3
    • /
    • pp.163-168
    • /
    • 1975
  • Rice and fish samples as well as a standard reference kale sample have been analyzed for the mercury content using two independent methods, i.e., one developed previously in this laboratory and the other reported by Sjostrand. The analytical results indicate differences in matrix effects depending on the type of sample, e.g., kale and fish samples show the same matrix effects, whereas rice samples show different effects compared to others.

  • PDF

Determination of the Optical Functions of Various Liquids by Rotating Compensator Multichannel Spectroscopic Ellipsometry

  • Bang, Kyung-Yoon;Lee, Seung-Hyun;Oh, Hye-Keun;An, Il-Sin;Lee, Hai-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.6
    • /
    • pp.947-951
    • /
    • 2005
  • Rotating compensator multichannel spectroscopic ellipsometry has been employed to determine the optical functions of various liquids used in chemistry. We attempted three different measurement configurations: (1) air-liquid interface, (2) prism-liquid interface, and (3) liquid-sample interface. In prism-liquid interface, we found that the prism surface had roughness and it should be considered in analysis for accurate results. In liquidsample interface, we had much higher reflection, better sensitivity, and less limitation compared to the other two configurations when crystalline silicon was used as reference sample. We discuss the merit of each configuration and present the optical functions of various liquids. Also we demonstrate Bruggeman effective medium theory to determine the optical properties of mixed liquid.

Determination of Total Hemoglobin in Whole Blood by Spectroscopy (분광학적 방법을 이용한 전혈내의 총 혈색소량 결정)

  • Kim, Y.J.;Yoon, G.;Kim, W.K.;Kim, J.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.251-253
    • /
    • 1996
  • Noninvasive monitoring of total Hemoglobin value is feasible with the use of spectroscopic measurements. As a step toward tile final goal of the development of a noninvasive monitor, the spectra$(400{\sim}800mm)$of EDTA whole blood were obtained along with reference total Hemoglobin values. Under the same condition water spectrum was generated. It was subtracted from each blood sample, and then tile first derivative of each subtracted data was taken by 'approximated first derivative algorithm' with gap (1,6,10,20nm). The correlation was obtained between total Hemoglobin and first valley wavelength of first derivative spectrum (sample number: 93).

  • PDF

Determination of the Allowable Vibration Level of the Atomic Force Microscope Equipment (원자 현미경 장비의 바닥 진동(정상 상태) 허용 기준 결정)

  • Lee, Dong-Yeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.161-164
    • /
    • 2000
  • Currently, Atomic Force Microscope(AFM) has been widely used to measure the surface topography of a sample by detecting interaction force between atoms on the sample and extremely sharp probe tip. The vertical resolution of AFM is mainly determined by external vibration noise. The resolution of AFM shows different values for the different environment, thus it is necessary to determine relationship between the criteria and the resolution of AFM regardless of environment. In this paper, we discuss the allowable level of floor vibration for AFM equipment at given resolution. The vibration criteria can be used as reference data to design mechanical structure and to analyze the structural dynamics of AFM equipment.

  • PDF

Uncertainty Evaluation of Ammonia Determination in Burley Tobacco (버어리종 담배중 암모니아성 질소에 대한 불확도 측정)

  • Lee Jeong-Min;Lee Kyoung-Ku;Han Sang-Bin
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.27 no.1 s.53
    • /
    • pp.107-114
    • /
    • 2005
  • The uncertainty of measurement in quantitative analysis of ammonia by continuous-flow analysis method was evaluated following internationally accepted guidelines. The sources of uncertainty associated with the analysis of ammonia were the weighing of sample, the preparation of extracting solution, the addition of extracting solution into the sample, the reproducibility of analysis and the determination of water content in tobacco, etc. In calculating uncertainties, Type A of uncertainty was evaluated by the statistical analysis of a series of observation, and Type B by the information based on supplier's catalogue and/or certificated of calibration. It was shown that the main source of uncertainty was caused by the volume measurement of 1 mL and 2 mL, the purity of ammonia reference material in the preparation of standard solution, the reproducibility of analysis and the determination of water content of tobacco. The uncertainty in the addition of extraction solution, the sample weighing, the volume measurement of 50 mL and 100 mL, and the calibration curve of standard solution contributed relatively little to the overall uncertainty. The expanded uncertainty of ammonia determination in burley tobacco at $95\%$ level of confidence was $0.00997\%$.

A study on the improvement of average seek time which use ref_T. E signal and sample pulse signal in optical disk drive (광디스크 드라이브에서 ref_T. E신호 와 샘플펄스 신호를 이용한 평균 탐색시간 개선에 관한 연구)

  • Lee, Si-Hyun;Kim, Kye-Kook;Kim, Hyung-Lea
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.5-11
    • /
    • 1995
  • In this paper, we design the new high-speed seek algorithm which can access the data of disk (in 3.5-inch optical disk drive). When seek the target track on optical disk in high-speed using the ref-T. E(Reference Tracking Error) and sample pulse signal, it's always possible high-speed seek without re-check and compensation for error by the ref_T. E and sample pulse signal. The performance test result is represented as follow ; it is satify the average seek time of 28mses.

  • PDF

Development of Continuous Real-time COD Measurement Sensor with Double Beam and Multiple Wavelength Analysis (더블 빔 구조, 다파장 분석을 적용한 연속식 실시간 COD 측정 센서 개발)

  • Lee, Joon-Seok;Shin, Daejung;Hyoung, Gi-Woo;Ryu, In-Jae
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.272-277
    • /
    • 2014
  • At present, the index of chemical oxygen demand (COD) is widely used as an indicator of organic water pollution with biochemical oxygen demand (BOD). But, traditional COD measurement method are not only with various chemical reagents exhausted, but also long time consumed, the operation procedure and the modification are much professional. This paper reported a novel COD measurement system using double-beam and multiple wavelength analysis UV-VIS spectrometries. It consists of pulsed xenon lamp, two-way optical fiber, optical switch, spectrometer and main processor. Proposed COD measurement system obtains any spectral information of water sample (KHP standard sample and two river water and wastewater) and reference sample (distilled water) in the range of 200~520 nm, corresponding to the COD concentration from 0 to 300 mg/L through calculating the UV absorbance. The system show improved precision and can work continuously fast at time interval about 25 seconds.

Palaeomagnetism of Tertiary Basins in Southern Korea : 3. Chongja-Ulsan Basins and its Vicinities (남한 제3기 분지지역에 대한 고자기 연구 : 3. 정자-울산분지와 그 일원)

  • Son, Moon;Kang, Hee-Cheol;Kim, In-Soo
    • Economic and Environmental Geology
    • /
    • v.29 no.4
    • /
    • pp.509-522
    • /
    • 1996
  • A total of 460 palaeomagnetic samples was collected from the Tertiary Chongja-Ulsan basins and surrounding area in the southeastern part of Korean peninsula. All samples were stepwise demagnetized by either alternating field or thermal method. It was found that most sample-sites have ChRM declination which has been rotated clockwise from the north-south reference direction of Tertiary East Asia, although other two extrusive sample-sites within the Chongja sedimentary basin show counterclockwise rotation of ChRM declination. Fold tests for the site-mean ChRMs of the latter two sites reveal insignificant result and negative result with 95% confidence level, respectively. The amount of the clockwise deflection of declination varies from about $20^{\circ}$ upto about $80^{\circ}$ according to the block to which each sample-site belongs. The amount of the counterclockwise deflection is about $20^{\circ}$. It is concluded that the clockwise ChRM rotation has been caused by dextral simple shearing accompanied by NNW-SSE spreading of the East Sea which has been active until about 16Ma, and that the counterclockwise rotation is a result of sinistral simple shearing associated with WNW-ESE contraction in the Korean Strait-SW Japan region at about 15 Ma.

  • PDF