• Title/Summary/Keyword: reference order

Search Result 3,260, Processing Time 0.031 seconds

Study on aerodynamic shape optimization of tall buildings using architectural modifications in order to reduce wake region

  • Daemei, Abdollah Baghaei;Eghbali, Seyed Rahman
    • Wind and Structures
    • /
    • v.29 no.2
    • /
    • pp.139-147
    • /
    • 2019
  • One of the most important factors in tall buildings design in urban spaces is wind. The present study aims to investigate the aerodynamic behavior in the square and triangular footprint forms through aerodynamic modifications including rounded corners, chamfered corners and recessed corners in order to reduce the length of tall buildings wake region. The method used was similar to wind tunnel numerical simulation conducted on 16 building models through Autodesk Flow Design 2014 software. The findings revealed that in order to design tall 50 story buildings with a height of about 150 meters, the model in triangular footprint with aerodynamic modification of chamfered corner facing wind direction came out to have the best aerodynamic behavior comparing the other models. In comparison to the related reference model (i.e., the triangular footprint with sharp corners and no aerodynamic modification), it could reduce the length of the wake region about 50% in general. Also, the model with square footprint and aerodynamic modification of chamfered corner with the corner facing the wind could present favorable aerodynamic behavior comparing the other models of the same cluster. In comparison to the related reference model (i.e., the square footprint with sharp corners and no aerodynamic modification), it could decrease the wake region up to 30% lengthwise.

S-value of Radioiodine($^{131}I$) in Korean Reference Adult Male (한국 성인남성 표준인을 대상으로 한 방사성옥소($^{131}I$)의 S-value 도출)

  • Kim, Jung-Hoon;Lim, Chang-Seon;Whang, Joo-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.41-47
    • /
    • 2008
  • In order to better understand the effects of absorbed radioiodine upon Korean reference adult male, a mathematical phantom representation was contrived based on composite data of the physiology of Korean reference adult male. Using this, S-values of radioiodine($^{131}I$) per each organ were calculated. The calculated S-values were compared to the existing data described in the TM-8381 report of ORNLcalculated on the basis of an ICRP-23 reference male. The results indicated that S-values were higher for the phantom based on Korean reference adult male. The results of this study illustrate that, while the bio-chemical constitution of each source and target organ of the torso are important, the relative location of the organs and characteristics of the radionuclides also exert important influences.

  • PDF

The Effect of Temperature and Cycles on Amplification of DNA by PCR (PCR에 의한 DNA 증폭에 미치는 온도와 Cycle 수)

  • Kim, Chong-Ho;Shin, Sang-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.1
    • /
    • pp.33-37
    • /
    • 2004
  • In order to study the effect of temperature of denaturation, annealing and extension and cycles on amplification of DNA by PCR method, We isolated the hepatitis B virus DNA from hepatitis B patient blood and compared the density of DNA amplified by Reference PCR Program (denaturation at $94^{\circ}C$ for 30 sec., annealing at $60^{\circ}C$ for 1 min., extension at $72^{\circ}C$ for 1 min., holding at $72^{\circ}C$ for 5min., 30 cycles) that is usually used in laboratory to the density of DNA amplified by PCR program changed only the denaturation temperature or annealing temperature or extension temperature. We amplified about 341bp of hepatitis B virus DNA by Reference PCR Program from hepatitis patient blood, but the DNAs denatured at $72^{\circ}C$ or $60^{\circ}C$ were not detectable on photoradiography film. The DNA amplified at $37^{\circ}C$ of annealing temperature was not detectable, but the DNA annealed at $72^{\circ}C$ was detectable the lower density of DNA than the DNA amplified by Reference PCR Program. Each DNA amplified by PCR program changed only the extension temperature to $37^{\circ}C$ or $60^{\circ}C$ was almost same density as DNA amplified by Reference PCR Program. We compared the density of hepatitis B virus DNA amplified by Reference PCR Program for 30 cycles, 20 cycles, 10 cycles, and 5 cycles. The DNA cycled for 20 cycles was not amplified well as cycled for 30 cycles, but the DNA was detectable on the photoradiography film. The DNAs amplified for 10 cycles or 5 cycles were not detectable on photoradiorgaphy film. The concentration of hepatitis B virus DNA amplified in Reference PCR condition for 30 cycles, 20 cycles, 10 cycles, and 5 cycles were $72{\mu}g/m{\ell}$, $83{\times}10^{-3}{\mu}g/m{\ell}$, $27{\times}10^{-6}{\mu}g/m{\ell}$, and nondetectable, respectively.

  • PDF

Efficient Fast Multiple Reference Frame Selection Technique for H.264/AVC (H.264/AVC에서의 효율적인 고속 다중 참조 프레임 선택 기법)

  • Lee, Hyun-Woo;Ryu, Jong-Min;Jeong, Je-Chang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.10C
    • /
    • pp.820-828
    • /
    • 2008
  • In order to achieve high coding efficiency, H.264/AVC video coding standard adopts the techniques such as variable block size coding, motion estimation with quarter-pel precision, multiple reference frames, rate-distortion optimization, and etc. However, these coding methods have a defect to greatly increase the complexity for motion estimation. Particularly, from multiple reference frame motion estimation, the computational burden increases in proportion to the number of the searched reference frames. Therefore, we propose the method to reduce the complexity by controlling the number of the searched reference frames in motion estimation. Proposed algorithm uses the optimal reference frame information in both $P16{\times}16$ mode and the adjacent blocks, thus omits unnecessary searching process in the rest of inter modes. Experimental results show the proposed method can save an average of 57.31% of the coding time with negligible quality and bit-rate difference. This method also can be adopted with any of the existing motion estimation algorithm. Therefore, additional performance improvement can be obtained.

Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector

  • Lee, Seung Kyu;Chang, Insu;Kim, Sang In;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul;Kim, Min Chae
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.72-78
    • /
    • 2019
  • Background: In the calibration and testing laboratory of Korea Atomic Energy Research Institute, the old X-ray generator used for the production of reference X-ray fields was replaced with a new one. For this newly installed X-ray irradiation system, beam alignment as well as the verification of beam qualities was conducted. Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber. Results and Discussion: Beam alignment was performed in three steps, and collimators and other components were arranged to maintain the uniformity of the mean air kerma rate within ${\pm}2.5%$ at the effective beam diameter of 28 cm. The beam quality was verified by using half-value layer measurement methods specified by American National Standard Institute (ANSI) N13.11-2009 and International Organization for Standardization (ISO)-4037. For each of the nine beams than can be generated by the new X-ray irradiation system, air kerma rates for X-ray fields of different beam qualifies were measured. The results showed that each air kerma rate and homogeneity coefficient of the first and second half-value layers were within ${\pm}5%$ of the recommended values in the standard documents. Conclusion: The results showed that the new X-ray irradiation system provides beam qualities that are as high as moderate beam qualities offered by National Institute of Standards and Technology in ANSI N13.11-2009 and those for narrow-spectrum series of ISO-4037.

Improved LTE Fingerprint Positioning Through Clustering-based Repeater Detection and Outlier Removal

  • Kwon, Jae Uk;Chae, Myeong Seok;Cho, Seong Yun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.11 no.4
    • /
    • pp.369-379
    • /
    • 2022
  • In weighted k-nearest neighbor (WkNN)-based Fingerprinting positioning step, a process of comparing the requested positioning signal with signal information for each reference point stored in the fingerprint DB is performed. At this time, the higher the number of matched base station identifiers, the higher the possibility that the terminal exists in the corresponding location, and in fact, an additional weight is added to the location in proportion to the number of matching base stations. On the other hand, if the matching number of base stations is small, the selected candidate reference point has high dependence on the similarity value of the signal. But one problem arises here. The positioning signal can be compared with the repeater signal in the signal information stored on the DB, and the corresponding reference point can be selected as a candidate location. The selected reference point is likely to be an outlier, and if a certain weight is applied to the corresponding location, the error of the estimated location information increases. In order to solve this problem, this paper proposes a WkNN technique including an outlier removal function. To this end, it is first determined whether the repeater signal is included in the DB information of the matched base station. If the reference point for the repeater signal is selected as the candidate position, the reference position corresponding to the outlier is removed based on the clustering technique. The performance of the proposed technique is verified through data acquired in Seocho 1 and 2 dongs in Seoul.

Study on Design of Protest Song Metadata based on OAIS Reference Model (OAIS 참조모형 기반 민중가요 메타데이터 설계에 관한 연구)

  • Kang, Minjeong;Chang, Wookwon
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.21 no.1
    • /
    • pp.211-230
    • /
    • 2021
  • This study aims to design folk song metadata based on the OAIS reference model for the folk songs' preservation and permanent use. Thus, the folk songs' general characteristics were investigated by researching literature and related technical standards. The type of records, the methods and standards for long-term storage of records, OAIS reference models, and each package's metadata elements were identified through opinions from the popular songs' creators and researchers. The results awere that first, folk songs were created for social transformation, serving as a cultural heritage different from popular songs given their noncommercial quality. Second, the types of folk song records were identified, and the long-term preservation system suitable for the types of records was based on the OAIS reference model. Third, the metadata were edited, and the OIS reference model was applied such that respect was given to the folk songs' characteristics, context, and original order. Fourth and last, information package metadata elements matching the folk songs' records were derived and applied to the representative Korean folk song, "The March for Being."

Design of an 1.8V 6-bit 2GSPS CMOS ADC with an One-Zero Detecting Encoder and Buffered Reference (One-Zero 감지기와 버퍼드 기준 저항열을 가진 1.8V 6-bit 2GSPS CMOS ADC 설계)

  • Park Yu Jin;Hwang Sang Hoon;Song Min Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.6 s.336
    • /
    • pp.1-8
    • /
    • 2005
  • In this paper, CMOS A/D converter with 6bit 2GSPS Nyquist input at 1.8V is designed. In order to obtain the resolution of 6bit and the character of high-speed operation, we present an Interpolation type architecture. In order to overcome the problems of high speed operation, a novel One-zero Detecting Encoder, a circuit to reduce the Reference Fluctuation, an Averaging Resistor and a Track & Hold, a novel Buffered Reference for the improved SNR are proposed. The proposed ADC is based on 0.18um 1-poly 3-metal N-well CMOS technology, and it consumes 145mW at 1.8V power supply and occupies chip area of 977um $\times$ 1040um. Experimental result show that SNDR is 36.25 dB when sampling frequency is 2GHz and INL/DNL is $\pm$0.5LSB at static performance.

A Study on the Amendments of the Cathodic Protection Criteria Considering IR Drops (전압강하를 고려한 전기방식 기준 개정에 관한 연구)

  • Ryou, Young-don;Lee, Jin-han;Jo, Young-do;Kim, Jin-Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.4
    • /
    • pp.50-57
    • /
    • 2016
  • According to the urban gas business legislation, cathodic protection systems should be applied for buried steel gas pipelines to prevent corrosion. In advanced countries including United States, the criteria for Cathodic Protection Potential is at least -850mV with respect to a saturated copper/copper sulfate electrode(CSE) when the CP applied, and the IR drops must be considered for valid interpretation. However, the IR drop through the pipe to soil boundary has been neglected in Korea. According to KGS code, a reference electrode must be placed in proximity to gas pipelines possible when measuring the CP potential. In this study, we have installed several solid reference electrodes around the buried pipeline(1.2m depth), lower surface(0.5m depth), and the surface individually in order to measure the CP potentials through the each reference electrode and find out the IR drops according to the location of each reference electrode. We have found the IR drop is the greatest when measuring the CP potential through the electrode placed on the ground and the IR drop is the smallest through the electrode installed near pipeline. Therefore, we have suggested the solid reference electrode should be installed as close as possible to buried pipeline in order to measure the correct CP potential without IR drop. We have also suggested the amendment of CP criteria considering IR drop.

Monitoring and Analysis of Galileo Services Performance using GalTeC

  • Su, H.;Ehret, W.;Blomenhofer, H.;Blomenhofer, E.
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.235-240
    • /
    • 2006
  • The paper will give an overview of the mission of GalTeC and then concentrate on two main aspects. The first more detailed aspect, is the analysis of the key performance parameters for the Galileo system services and presenting a technical overview of methods and algorithms used. The second more detailed aspect, is the service volume prediction including service dimensioning using the Prediction tool. In order to monitor and validate the Galileo SIS performance for Open Service (OS) and Safety Of Life services (SOL) regarding the key performance parameters, different analyses in the SIS domain and User domain are considered. In the SIS domain, the validation of Signal-in-Space Accuracy SISA and Signal-in-Space Monitoring Accuracy SISMA is performed. For this purpose first of all an independent OD&TS and Integrity determination and processing software is developed to generate the key reference performance parameters named as SISRE (Signal In Space Reference Errors) and related over-bounding statistical information SISRA (Signal In Space Reference Accuracy) based on raw measurements from independent sites (e.g. IGS), Galileo Ground Sensor Stations (GSS) or an own regional monitoring network. Secondly, the differences of orbits and satellite clock corrections between Galileo broadcast ephemeris and the precise reference ephemeris generated by GalTeC will also be compared to check the SIS accuracy. Thirdly, in the user domain, SIS based navigation solution PVT on reference sites using Galileo broadcast ephemeris and the precise ephemeris generated by GalTeC are also used to check key performance parameters. In order to demonstrate the GalTeC performance and the methods mentioned above, the paper presents an initial test result using GPS raw data and GPS broadcast ephemeris. In the tests, some Galileo typical performance parameters are used for GPS system. For example, the maximum URA for one day for one GPS satellite from GPS broadcast ephemeris is used as substitution of SISA to check GPS ephemeris accuracy. Using GalTeC OD&TS and GPS raw data from IGS reference sites, a 10 cm-level of precise orbit determination can be reached. Based on these precise GPS orbits from GalTeC, monitoring and validation of GPS performance can be achieved with a high confidence level. It can be concluded that one of the GalTeC missions is to provide the capability to assess Galileo and general GNSS performance and prediction methods based on a regional and global monitoring networks. Some capability, of which first results are shown in the paper, will be demonstrated further during the planned Galileo IOV phase, the Full Galileo constellation phase and for the different services particularly the Open Services and the Safety Of Life services based on the Galileo Integrity concept.

  • PDF