• 제목/요약/키워드: reference materials

검색결과 1,934건 처리시간 0.031초

표면분석용 인증표준물질의 개발 II : 깊이분포도용 다층 박막 표준물질의 개발 (Development of certified reference material (CRM)s for surface analysis II : multilayer thin films for sputter depth profiling)

  • 김경중;문대원
    • 한국진공학회지
    • /
    • 제8권3B호
    • /
    • pp.283-289
    • /
    • 1999
  • Multilayer thin film reference materials for the sputter depth profiling analysis are used to calibrate the sputter depth scale by measuring the sputtering rate and to optimize the sputtering conditions for the best depth resolution. Surface analysis group of Korea Research Institute of Standards and science (KRISS) have developed various types of multilayer thin films by using an ion beam sputter deposition and in-situ surface analysis system. The chemical states of the thin films reference materials were certified by in-situ XPS and the thicknesses were certified by transmission electron microscopy (TEM).

  • PDF

BIO-RAD 정도관리 물질을 이용한 방사면역측정법의 Acceptable Range 설정에 대한 제언 (Radioimmunoassay Using Quality Control Materials BIO-RAD of the Suggestions for Setting Acceptable Range)

  • 박희원;김태훈;노경운;김현주
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.108-114
    • /
    • 2012
  • 면역측정법을 이용하는 검사실에서 가장 많이 사용하고 있는 상업용 제3자 정도관리물질이 BIO-RAD사에서 제공하는 물질이다. 현재 BIO-RAD 정도관리 물질에 포함된 Reference Sheet에는 비방사면역측정을 이용한 검사방법과 검사장비별로 각 측정물질의 Acceptable Range가 기재되어 있다. 그러나 방사면역측정법을 이용하여 검사하는 측정kit나 기기에 대해서는 실무에 적용할 만한 Acceptable Range에 대한 언급이 다소 부족한 것이 현실이다. 방사면역측정검사에 대한 Acceptable Range를 설정하여 검사결과의 객관성을 높이고 누적된 데이터를 제조사에 권고하여 발행되는 Reference Sheet에 기재하고자 한다. 본원에서는 2009년부터 부분적으로 BIO-RAD 정도관리 물질을 사용하여 2011년에는 일부 특정 항목을 제외한 대부분의 검사종목에 BIO-RAD 제 3자 정도관리물질을 사용하고 있다. 따라서 측정된 내부정도관리 데이터를 BIO-RAD사의 Unity Real Time program (version 1.0.9.27)을 이용하여 Acceptable Range를 설정하였다. BIO-RAD 정도관리 물질을 사용하는 약 50가지 검사종목의 20개 Point Data의 평균값, 표준편차, 변이계수를 구하여 측정kit별 Acceptable Range를 산출하였으며, 자동화 면역 측정기기인 Roche Elecsys/ E170/ cobas e Systems의 측정값과 비교하였다. 현재 시행하고 있는 외부정도관리 프로그램과 같이 BIO-RAD 정도관리 물질을 공통으로 사용하는 병원과 peer group을 설정하여 측정 kit별, 기기별 Acceptable Range를 제조사에 권고하여 Reference Sheet에 방사면역검사실에 적합한 Acceptable Range를 기재하여 검사결과의 객관성을 높이고 국내외적으로 방사면역측정법에 대한 인지도를 높이고자 한다.

  • PDF

Measurement of Cortisol in Human Serum by Isotope Dilution Liquid Chromatography/Mass Spectrometry and a Comparison through a Proficiency Testing

  • Lee, Hwa-Shim;Shin, Hye-Sun;Park, Sang-Ryoul;Park, Chang-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권5호
    • /
    • pp.1149-1154
    • /
    • 2010
  • Liquid chromatography/mass spectrometry using isotope dilution method has been established as a primary method for the measurement of cortisol in human serum. Verification of this method was accomplished by the participation in Consultative Committee for Amount of Substance-Metrology in Chemistry (CCQM) pilot study. Two levels of cortisol certified reference materials were prepared and certified by the established method. They were used as sample materials for the proficiency testing. The expanded uncertainty in the measurement of cortisol in human serum was approximately 1.2% at 95% confidence level. The results of the proficiency testing showed a good precision among the participants, but some bias to the certified values. This means that commercial field laboratories should keep traceability chain to SI unit through available reference measurement procedures and/or available reference materials.

흑요암을 이용한 유리 지질 표준물질에 대한 예비 연구 (A Preliminary Study for a Glass Geological Reference Material Using Obsidian)

  • 진미은;좌용주;박상구;선광민
    • 광물과 암석
    • /
    • 제33권1호
    • /
    • pp.65-71
    • /
    • 2020
  • 유리 표준물질은 정밀 지구화학 분석법에 필수적으로 이용되는 표준물질이다. 기존의 합성 유리 표준물질의 단점인 자연 암석과의 조성 차이로 인한 높은 불확실성을 보완하기 위해, 자연산 암석을 이용하여 유리 표준물질을 제작하였다. 백두산 흑요암인 NK-B1G 시료는 미세결정이나 포유물 등의 결정을 포함하지 않는 자연 유리질 암석으로, EPMA나 LA-ICPMS 분석 등의 미세분석을 위한 표준물질로서의 적합성을 확인하였다.

공간주파수대역에서 기저대역 확장을 통한 원전 대비시험편과 대비 보정 시험편의 초음파 영상 개선 (Ultrasonic Images Enhancement of the SS Reference Specimen and the Reference Calibration Block for NPPs by the Combining Bases of Support for Spatial Frequency)

  • 박치승;김선진
    • 한국재료학회지
    • /
    • 제13권10호
    • /
    • pp.651-657
    • /
    • 2003
  • Ultrasonic microscope has been used to detect the defects on surface or inner solid. Conventionally, it has used at a single operating frequency. The resolution and quality of the measured images are determined by a characteristic of the transducer of the ultrasonic microscope. The conventional ultrasonic microscope has been used envelope detector to detect the amplitude of reflected signal, but the changes in amplitude is not sensitive enough for specimen with microstructure that in phase. In this paper, we have studied multi-frequency depth resolution enhancement with ultrasonic reflection microscope for the reflectors of a stainless steel reference specimen and a reference calibration block to be used as the material in nuclear power plants for ISI, PSI. Increased depth resolution can be obtained by taking two, three-dimensional images at more that one frequency and numerically combining the results. As results of the experiment, we could get enhanced images with the rate of contrast in proportion and high quality signal distribution for the image to the changing rate of depth for the reflectors of the two kinds of specimens.

기준표적상의 미세구조가 초음파 후방산란에 미치는 영향 (Influence of Microstructure on Reference Target on Ultrasonic Backscattering)

  • 김호철;김용태
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권1E호
    • /
    • pp.38-44
    • /
    • 2010
  • This paper is based on our comments and proposed amendments to the documents, Annex A, Phantom for determining Maximum Depth of Penetration, and Annex B, Local Dynamic Range Using Acoustical Test Objects 87/400/CDV. IEC 61391-2 Ed. 1.0 200X, prepared by IEC technical Committee 87; Ultrasonics. The documents are concerned with the influence of microstructure of reference target material on the ultrasonic backscattering. Previous works on the attenuation due to backreflection and backscattering of reference target materials are reviewed. The drawback to the use of ungraded stainless steel and metallic materials without microstructural data such as, crystal structure, basic acoustic data of sound velocity and attenuation, grain size, roughness and elastic constants has been discussed. The analysis suggested that the insightful conclusion can be made by differentiating the influence arising from target size and microstructure on the backscattering measurements. The microstructural parameters are associated with physical, geometrical, acoustical and mechanical origins of variation with frequency. Further clarification of such a diverse source mechanisms for ultrasonic backscattering would make the target material and its application for medical diagnosis and therapy simpler and more reliable.

Development of Methyl 2-aminobenzoate Reference Material in a Biocidal Product Matrix

  • So Yeon Lee;Kyungmin Kim;Junghyun Kim;Wooil Kim;Han Bin Oh
    • Mass Spectrometry Letters
    • /
    • 제14권4호
    • /
    • pp.166-172
    • /
    • 2023
  • The utilization of methyl 2-aminobenzoate as a biocide and pesticide has raised concerns regarding its potential toxicity. To assess its safety, it is crucial to determine its quantity and related toxicity using reference materials (RMs) or certified reference materials (CRMs). As an RM and CRM containing methyl 2-aminobenzoate within a biocidal product matrix is currently unavailable, this study aimed to produce a high-quality RM containing methyl 2-aminobenzoate, ensuring its homogeneity and stability, following the ISO Guide 35 and ISO 17034. The study determined that the produced RM exhibited homogeneity, as indicated by a calculated F-value (1.91) smaller than the critical F-value (3.02). In the assessment of isochronous short-term stability, the slope of the linear regression for the RM showed no statistically significant difference from zero when stored at temperatures of 4, 18, and 60 ℃ for 4 weeks. Regarding classical long-term stability, the RM demonstrated sustained stability over the course of one year when stored at 4 ℃. This study has successfully developed an RM for monitoring methyl 2-aminobenzoate in biocides and pesticides. Its quality underwent rigorous evaluation, confirming both homogeneity and stability.

정보 및 참고봉사상의 의사통신과정(意思通信過程) -참고과목을 위한 제언(提言)- (Communication Process in Reference/Information Service; Its Implication for Reference Teaching)

  • 노옥순
    • 한국비블리아학회지
    • /
    • 제2권1호
    • /
    • pp.66-87
    • /
    • 1974
  • It is the prime importance of the information and the reference-librarians to better understand the communication functions of the library since they are the ones to whom the library users come first with their informational needs. Reference librarians often have the problem of providing information to those who may have little experience with, or interest in the library. There is also a problem of finding out what the person really wants, not what he says he wants. Therefore, the interaction between the librarian and the user involves a highly complex activity of communication with each other even before the actual search begins. Reference librarians cannot perform to any degree of success without comprehension of the general patterns and processes of communication in information seeking. Nonverbal as well as verbal transmittal process on the part of both librarians and patrons should not be overlooked. Some of the difficulties and barriers of library communication are brought so that possible cures and improvement may be sought. The basic purpose of the reference interview through which this interpersonal communication takes place is for the reference specialist to enable to link the needs of the patron with potential resource of the library. The writer firmly believes that this importance of the process be taught as well as the materials in reference service regardless of the level of the course offered in library science department.

  • PDF

참조응력법에 입각한 T-배관 국부 크리프 파단 평가를 위한 응력해석 사례연구 (Reference Stress Based Stress Analysis for Local Creep Rupture of a T-pipe)

  • 신규인;윤기봉;김윤재
    • 대한기계학회논문집A
    • /
    • 제30권8호
    • /
    • pp.873-879
    • /
    • 2006
  • To investigate applicability of the reference stress approach as simplified inelastic stress analysis to estimate local creep rupture, detailed finite element stress analyses of a T-piece pipe with different inner pressure and system loading levels are performed. The reference stresses are obtained from the finite element (FE) limit analysis based on elastic-perfectly-plastic materials, from which the local reference stress for creep rupture is determined from R5. The resulting inelastic stresses are compared with elastic stresses resulting from linear elastic FE calculations. Furthermore they are also compared with the stresses from full elastic-creep FE analyses. It shows that the stresses estimated from the reference stress approach compare well with those from full elastic-creep FE analysis, which are significantly lower than the elastic stress results. Considering time and efforts for full inelastic creep analysis of structures, the reference stress approach is shown to be a powerful tool for creep rupture estimates and also to reduce conservatism of elastic stress analysis significantly.

Benzo[a]pyrene 분석용 토양 숙련도 표준시료 개발에 관한 연구 - 후보 표준물질의 인증을 위한 균질성, 안정성 평가를 중심으로 - (A Study on the Development of Soil-based PTMs for Analysis of Benzo[a]pyrene - Focusing on the Evaluation of Homogeneity and Stability for the Certification of Benzo[a]pyrenecandidate Reference Materials -)

  • 이민효;이군택;주창규;김용훈;이법열;최성헌;김명옥;홍석영;김금희;이원석
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권6호
    • /
    • pp.49-58
    • /
    • 2014
  • This study was implemented as a part of the experiment to develop two kinds of soil-based Benzo[a]pyrene (BaP) proficiency testing materials (PTMs) for soil analysis. A test was carried out for the check of solubility of the reference material (high purity reagent) using several solvents. Another test was also conducted for the evaluation of homogeneity and stability of two kinds of candidate soil reference materials. The test analysis of BaP in terms of the candidate materials was conducted according to the Standard Soil Analytical Methods by Ministry of Environment. Dissolution of the reference material was shown to vary depending on solvent type and was higher in the order of Dichloromethane > Acetone > Acetone/MeOH (9 : 1) > N-hexane. In addition, the slope on calibration curve for BaP standard solutions was largest on BaP standard solutions prepared with dichloromethane of the tested solvents. Such tendency appeared egually in the commercial BaP standard solution. Therefore, it is thought to be reasonable to use dichloromethane as the solvent in case of the standard stock solution that is used for the measurement of BaP concentration in soil. ISO 13528 and IUPAC protocol were used for verification of homogeneity on the two kinds of soil candidate materials, Both candidate materials were sufficiently homogeneous. Stability assessment of the two candidate materials was made according to ISO Guide 35 and the result showed that both batches did not have any long-term and short term stability issues that might occur during shipping. However, monitoring results of BaP concentration in soil showed that BaP concentration of the two batches measured at 15 days after the sample preparation was reduced by about 24~37% compared with that of the samples measured on 0 day of the sample preparation. Identification was done with several treatments such as irradiation and sterilization etc. The major cause was shown to be irradiation to the samples.