Standard Neutron Irradiation Facility for Calibration of Radiation Protection Instruments by Radioactive Neutron Sources (방사성 중성자선원에 의한 방사선방어측정기의 교정을 위한 표준 중성자 조사장치 연구)

  • Choi, Kil-Oung;Lee, Kyung-Ju;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.1
    • /
    • pp.66-70
    • /
    • 1989
  • In routine testing, the radioactive neutron sources are particularly suitable for producing standard. neutron fields. The ISO TC-85 has proposed neutron reference radiation for the calibration of neutron measuring devices used for radiation protection purposes. Radiation laboratory of KSRI has installed a standard irradiation facility using $^{252}Cf$ and $^{241}Am-Be$ sources for calibrating personal dosimeters according to the recommendations given in ISO TC-85. In this study, correction factors for calibration related to neutron scattering and anisotropy are obtained by experiments with commercial rem meter for demonstration purposes.

  • PDF

Neutron Calibration Field of a Bare 252Cf Source in Vietnam

  • Le, Thiem Ngoc;Tran, Hoai-Nam;Nguyen, Khai Tuan;Trinh, Giap Van
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.277-284
    • /
    • 2017
  • This paper presents the establishment and characterization of a neutron calibration field using a bare $^{252}Cf$ source of low neutron source strength in Vietnam. The characterization of the field in terms of neutron flux spectra and neutron ambient dose equivalent rates were performed by Monte Carlo simulations using the MCNP5 code. The anisotropy effect of the source was also investigated. The neutron ambient dose equivalent rates at three reference distances of 75, 125, and 150 cm from the source were calculated and compared with the measurements using the Aloka TPS-451C neutron survey meters. The discrepancy between the calculated and measured values is found to be about 10%. To separate the scattered and the direct components from the total neutron flux spectra, an in-house shadow cone of 10% borated polyethylene was used. The shielding efficiency of the shadow cone was estimated using the MCNP5 code. The results confirmed that the shielding efficiency of the shadow cone is acceptable.

Uncertainty of Total Alkaloids and Reducing Sugar Determination in Flue-cured Tobacco (황색종 담배중 전알카로이드와 환원당 분석에 대한 불확도 측정)

  • 백순옥;장기철;이운철;한상빈
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.23 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • This study was carried out to evaluate the uncertainty in the analysis of total alkaloids and reducing sugar content in flue-cured tobacco. The sources of uncertainty associated with the analysis of total alkaloids and reducing sugar were the weighing of sample, the preparation of extracting solution, the addition of extracting solution into the sample, the preparation of standard solution, the precision of calibration curve for standard solution, the reproducibility of analysis, and the determination of water content in tobacco, etc. For the calculating uncertainties, Type A of uncertainty was evaluated by the statistical analysis of a series of observation, and Type B by the information based on supplier’s catalogue and/or certificated of calibration. It was shown that the main source of uncertainty was caused by the calibration curve of standard solution, the reproducibility of analysis, the volume measurement of 1$m\ell$, and the purity of nicotine reference material in the preparation of standard solution. The uncertainty in the addition of extracting solution, the sample weighing, the volume measurement of 100$m\ell$, and the determination of water content of tobacco contributed relatively little to the overall uncertainty. The expanded uncertainty of total alkaloids and reducing sugar in flue-cured tobacco at 95% level of confidence was $\pm$0.12% and $\pm$0.54%, respectively.

  • PDF

Identification and Correction of Microlens-array Error in an Integral-imaging-microscopy System

  • Imtiaz, Shariar Md;Kwon, Ki-Chul;Alam, Md. Shahinur;Hossain, Md. Biddut;Changsup, Nam;Kim, Nam
    • Current Optics and Photonics
    • /
    • v.5 no.5
    • /
    • pp.524-531
    • /
    • 2021
  • In an integral-imaging microscopy (IIM) system, a microlens array (MLA) is the primary optical element; however, surface errors impede the resolution of a raw image's details. Calibration is a major concern with regard to incorrect projection of the light rays. A ray-tracing-based calibration method for an IIM camera is proposed, to address four errors: MLA decentering, rotational, translational, and subimage-scaling errors. All of these parameters are evaluated using the reference image obtained from the ray-traced white image. The areas and center points of the microlens are estimated using an "8-connected" and a "center-of-gravity" method respectively. The proposed approach significantly improves the rectified-image quality and nonlinear image brightness for an IIM system. Numerical and optical experiments on multiple real objects demonstrate the robustness and effectiveness of our proposed method, which achieves on average a 35% improvement in brightness for an IIM raw image.

Vision Aided Inertial Sensor Bias Compensation for Firing Lane Alignment (사격 차선 정렬을 위한 영상 기반의 관성 센서 편차 보상)

  • Arshad, Awais;Park, Junwoo;Bang, Hyochoong;Kim, Yun-young;Kim, Heesu;Lee, Yongseon;Choi, Sungho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.9
    • /
    • pp.617-625
    • /
    • 2022
  • This study investigates the use of movable calibration target for gyroscopic and accelerometer bias compensation of inertial measurement units for firing lane alignment. Calibration source is detected with the help of vision sensor and its information in fused with other sensors on launcher for error correction. An algorithm is proposed and tested in simulation. It has been shown that it is possible to compensate sensor biases in firing launcher in few seconds by accurately estimating the location of calibration target in inertial frame of reference.

An Accurate Current Reference using Temperature and Process Compensation Current Mirror (온도 및 공정 보상 전류 미러를 이용한 정밀한 전류 레퍼런스)

  • Yang, Byung-Do
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.8
    • /
    • pp.79-85
    • /
    • 2009
  • In this paper, an accurate current reference using temperature and process compensation current mirror (TPC-CM) is proposed. The temperature independent reference current is generated by summing a proportional to absolute temperature (PTAT) current and a complementary to absolute temperature (CTAT) current. However, the temperature coefficient and magnitude of the reference current are influenced by the process variation. To calibrate the process variation, the proposed TPC-CM uses two binary weighted current mirrors which control the temperature coefficient and magnitude of the reference current. After the PTAT and CTAT current is measured, the switch codes of the TPC-CM is fixed in order that the magnitude of reference current is independent to temperature. And, the codes are stored in the non-volatile memory. In the simulation, the effect of the process variation is reduced to 0.52% from 19.7% after the calibration using a TPC-CM in chip-by-chip. A current reference chip is fabricated with a 3.3V 0.35um CMOS process. The measured calibrated reference current has 0.42% variation for $20^{\circ}$C${\sim}$100$^{\circ}$C.

Solar Radiation Measurement and Data Quality Management (태양자원 측정 및 데이터 품질관리)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.63.2-63.2
    • /
    • 2010
  • Solar radiation data are used in several forms and for a variety of purposes. The most detailed information we have is beam and diffuse solar radiation on a horizontal surface, by hours, which is useful in simulations of solar processes. Daily data are more often available and monthly total solar radiation on horizontal surface can be used in some process design methods. However, as performance is generally not linear with solar radiation, the use of average may lead to serious errors if non-linearities ara not taken into account. It is also possible to reduce radiation data to more manageable forms by statistical methods. The control of the quality of most measurements is relegated to the control of the measuring instruments and measuring processes themselves. An accurate measurement will usually result from the use of a high-quality instrument that has been accurately calibrated and is properly used by a qualified individual.

  • PDF

Calibration and Uncertainty Measurement of Differential Mobility Analyzer Using 100 nm NIST SRM 1963 (100 nm NIST 표준입자를 이용한 미분형 전기 이동도 분석기의 교정 및 불확실도 측정)

  • Lee, Snag-Jin;Ahn, Jin-Hong;Ahn, Kang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1766-1771
    • /
    • 2003
  • House made differential mobility analyzer(DMA) is calibrated with NIST SRM 1691(300 nm PSL). Then the particle size and uncertainty for differential mobility analyzer(DMA) using the NIST SRM 1963(100 nm PSL). In result, calibration of prototype DMA is measured using 300 nm NIST SRM 1691, then sheath air flow was corrected 126.67 ㎤/s. Corrected sheath air flow is used in uncertainty measurement of prototype DMA. Uncertainty analysis is performed using NIST SRM 1963(100 nm PSL). The experimental result shows that NIST SRM 1963 is measured as 102.17 nm with a type A uncertainty of 0.33 nm.

Development of Error Compensation Algorithm for Image based Measurement System (미세부품 영상 측정시 진동에 의한 오차 보상 알고리즘 개발)

  • Pyo Chang Ryul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.10
    • /
    • pp.102-108
    • /
    • 2004
  • In this paper, we studied a vibration problem that is critical and common to most precision measurement systems. For micro mechanical part measurements, results obtained from the vision-based precision measurement system may contain errors due to the vibration. In order to defeat this generic problem, for the current study, a PC based image processing technique was used first, to assess the effect of the vibration to the precision measurement and second, to develop an in-situ calibration algorithm that automatically compensate the measurement results in real time. We used a set of stereoscopic CCD cameras to acquire the images for the dimensional measurement and the reference measurement. The mapping function was obtained through the in-situ calibration to compensate the measurement results and the statistical analysis for the actual results is provided in the paper. Based on the current statistical study, it is expected to obtain high precision results for the micro measurement systems.

The Levitation Mass Method: A Precision Mass and Force Measurement Technique

  • Fujii, Yusaku
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.46-50
    • /
    • 2008
  • The present status and future prospects of the levitation mass method (LMM), a technique for precision mass and force measurement, are reviewed. In the LMM, the inertial force of a mass levitated using a pneumatic linear bearing is used as the reference force applied to the objects being tested, such as force transducers, materials, or structures. The inertial force of the levitated mass is measured using an optical interferometer. We have modified this technique for dynamic force calibration of impact, oscillation, and step loads. We have also applied the LMM to material testing, providing methods for evaluating material viscoelasticity under an oscillating or impact load, evaluating material friction, evaluating the biomechanics of a human hand, and generating and measuring micro-Newton-level forces.