• Title/Summary/Keyword: reference based

Search Result 7,520, Processing Time 0.038 seconds

A 10b 25MS/s $0.8mm^2$ 4.8mW 0.13um CMOS ADC for Digital Multimedia Broadcasting applications (DMB 응용을 위한 10b 25MS/s $0.8mm^2$ 4.8mW 0.13um CMOS A/D 변환기)

  • Cho, Young-Jae;Kim, Yong-Woo;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.37-47
    • /
    • 2006
  • This work proposes a 10b 25MS/s $0.8mm^2$ 4.8mW 0.13um CMOS A/D Converter (ADC) for high-performance wireless communication systems such as DVB, DAB and DMB simultaneously requiring low voltage, low power, and small area. A two-stage pipeline architecture minimizes the overall chip area and power dissipation of the proposed ADC at the target resolution and sampling rate while switched-bias power reduction techniques reduce the power consumption of analog amplifiers. A low-power sample-and-hold amplifier maintains 10b resolution for input frequencies up to 60MHz based on a single-stage amplifier and nominal CMOS sampling switches using low threshold-voltage transistors. A signal insensitive 3-D fully symmetric layout reduces the capacitor and device mismatch of a multiplying D/A converter while low-noise reference currents and voltages are implemented on chip with optional off-chip voltage references. The employed down-sampling clock signal selects the sampling rate of 25MS/s or 10MS/s with a reduced power depending on applications. The prototype ADC in a 0.13um 1P8M CMOS technology demonstrates the measured DNL and INL within 0.42LSB and 0.91LSB and shows a maximum SNDR and SFDR of 56dB and 65dB at all sampling frequencies up to 2SMS/s, respectively. The ADC with an active die area if $0.8mm^2$ consumes 4.8mW at 25MS/s and 2.4mW at 10MS/s at a 1.2V supply.

The Etiologic Agents and Clinical Outcomes of Adult Community-acquired Pneumonia in Jeju (제주지역 성인 지역사회획득 폐렴의 원인균 및 임상양상)

  • Jeon, Bong-Hee;Kim, Miok;Kim, Jeong Hong;Shin, Sang Yop;Lee, Jaechun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.5
    • /
    • pp.358-364
    • /
    • 2009
  • Background: The appropriate empirical antimicrobial choice in the treatment of community-acquired pneumonia (CAP) should be advocated by community-based information on the etiologic pathogens, their susceptibility to antimicrobials, clinical characteristics and outcomes. Jeju is a geographically isolated and identical region in Korea. However, there is no regional reference on adult CAP available. This study investigated the etiologic agents and clinical outcomes of adult patients diagnosed with CAP in Jeju, Korea, to help guide the empirical antimicrobial choice. Methods: A prospective observational study for one year in a referral hospital in Jeju, Korea. Patients diagnosed with CAP were enrolled with their clinical characteristics. Microbiological evaluations to identify the etiologic agents in the adult patients with CAP were performed with blood culture, expectorated sputum smear and culture, antibody tests for mycoplasma, chlamydophila, and antigen tests for legionella and pneumococcus. The clinical outcomes of the initial empirical treatment were analyzed. Results: Two hundred and three patients with mean age of 64 and 79 females were enrolled. Ten microbials from 90 cases (44.3%) were isolated and multiple isolates were confirmed in 30. Among the microbial isolates, S. pneumoniae (36.3%) was the most common, followed by M. pneumoniae (23.0%), C. pneumoniae (17.0%), S. aureus (9.6%) and P. aeruginosa (5.9%). The initial treatment failure (23.8%) was related to the isolation of polymicrobial pathogens, elevated inflammatory markers, and the presence of pleural effusion. Among the 30 isolates of S. pneumoniae, 16 (53.3%) were not susceptible to penicillin, and 19 isolates (63.3%) to erythromycin and clarithromycin. However, 29 isolates (96.7%) were susceptible to levofloxacin and ceftriaxone. Conclusion: S. pneumoniae, M. pneumoniae, S. aureus, and P. aeruginosa are frequent etiologic agents of adult CAP in Jeju, Korea. The clinical characteristics and antibiotic resistance should be considered when determining the initial empirical antimicrobial choice. Respiratory quinolone or ceftriaxone is recommended as an empirical antimicrobiotic in the treatment of adult CAP in Jeju, Korea.

The Cut-off Values and Related Factors for Serum Total Cholesterol in Normal Korean Adults (정상 성인에서 총콜레스테롤의 분별치와 관련 요인)

  • 홍인선;김지식;여영규
    • Biomedical Science Letters
    • /
    • v.2 no.2
    • /
    • pp.187-198
    • /
    • 1996
  • The cut-off values and related factors for total cholesterol of serum in normal Korean adults were studied from March to October, 1995, based on the data of 1,818 healthy adults of human involved the male and female. The comparisons of the serum total cholesterol levels were analyzed by sex, age, systolic blood pressure, diastolic blood pressure, body weight, height, PIBW, BMI and other biochemical tests. 1. The serum total cholesterol level were 194.4 mg/dl in total group, 186.9 mg/dl for male, and 197.6 mg/dl for female. 2. There was no significant differences by sex among the 21 to 50 ages group, but significantly higher in women than in men over 51 years old. 3. In general, the levels of serum total cholesterol were increased with age, the highest level in men was 192.7 mg/ dl in 51 to 60 years old, and 210.5 mg/dl in more than 60 years old in women. 4. The cut-off values of serum total cholesterol for moderate risk were 191 mg/dl in 21 to 30 years group, 195 mg/dl in 31 to 40 years,214 mg/dl in 41 to 50 years, 227 mg/dl in 51 to 60 years, and 222 mg/dl in more than 61 years. The cut-off values of serum total cholesterol for high risk were 214 mg/dl dl in 21 to 30 years group, 214 mg/dll in 31 to 40 years, 239 mg/dl in 41 to 50 years, 213 mg/dl in 51 to 60 years, and 248 mg/dl in more than 61 years. 5. The mean values of serum total cholesterol were showed positive correlation with age, PIBW, BMI, systolic blood pressure and diastolic blood pressure. 6. Serum total cholesterol level of drinking group(188.9$\pm$34.85mg/dl) was showed love. than those of non-drinking group(196.0$\pm$36.0 mg/dl). 7. Serum total cholesterol levels of regular excercise group(192.1$\pm$33.3 mg/dl) was significantly lower than those of non regular excercise group(195.8$\pm$37.0 mg/dl).

  • PDF

The Dose Attenuation according to the Gantry Angle and the Photon Energy Using the Standard Exact Couch and the 6D Robotic Couch (Standard Exact Couch와 6D Robotic Couch를 이용한 광자선의 조사각에 따른 선량 감쇠에 대한 연구)

  • Kim, Tae Hyeong;Oh, Se An;Yea, Ji Woon;Park, Jae Won;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.79-85
    • /
    • 2016
  • The objective of this study is to increase the accuracy of dose transmission in radiation therapy using two types of treatment tables, standard exact couch (Varian 21EX, Varian Medical Systems, Milpitas, CA) and 6D robotic couch (Novalis, BrainLAB A.G., Heimstetten, Germany)). We examined the dose attenuation based on the two types of treatment tables and studied the dose of attenuation using the phase (In/Out) for the standard exact couch. We measured the relative dose according to the incident angle of a penetrative photon beam under a treatment table. The incident angle of the photon beam was from $0^{\circ}$ to $360^{\circ}$ in the increments of $5^{\circ}$. The reference angle was set to $0^{\circ}$. Furthermore, the relative dose of the 6D robotic couch was measured using 6 MV and 15 MV, and that of the standard exact couch was measured at the sliding rail position (In-Out) using 6 MV and 10 MV. In the case of the standard exact couch, the measured relative dose was 16.53% (rails at the "In position," $175^{\circ}$, 6 MV), 12.42% (rails at the "In position," $175^{\circ}$, 10 MV), 13.13% (rails at the "Out position," $175^{\circ}$, 6 MV), and 9.96% (rails at the "Out position," $175^{\circ}$, 10 MV). In the case of the 6D robotic couch, the measured relative dose was 6.82% ($130^{\circ}$, 6 MV) and 4.92% ($130^{\circ}$, 15 MV). The photon energies were surveyed at the same incident angle. The dose attenuation for an energy of 10 MV was 4~5% lower than that for 6 MV. This indicated that the higher photon energy, lesser is the attenuation. The results of this study indicated that the attenuation rate for the 6D robotic couch was confirmed to be 1% larger than that for the standard exact couch at 6 MV and $180^{\circ}$. In the case of the standard exact couch, the dose attenuation was found to change rapidly in accordance with the phase ("In position" and "Out position") of the sliding rail.

Suggestion for Comprehensive Quality Assurance of Medical Linear Accelerator in Korea (국내 선형가속기의 포괄적인 품질관리체계에 대한 제언)

  • Choi, Sang Hyoun;Park, Dong-wook;Kim, Kum Bae;Kim, Dong Wook;Lee, Jaiki;Shin, Dong Oh
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.294-303
    • /
    • 2015
  • American Association of Physicists in Medicine (AAPM) Published Task Group 40 report which includes recommendations for comprehensive quality assurance (QA) for medical linear accelerator in 1994 and TG-142 report for recommendation for QA which includes procedures such as intensity-modulated radiotherapy (IMRT), stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) in 2010. Recently, Nuclear Safety and Security Commission (NSSC) published NSSC notification no. 2015-005 which is "Technological standards for radiation safety of medical field". This notification regulate to establish guidelines for quality assurance which includes organization and job, devices, methods/frequency/tolerances and action levels for QA, and to implement quality assurance in each medical institution. For this reason, all of these facilities using medical machine for patient treatment should establish items, frequencies and tolerances for proper QA for medical treatment machine that use the techniques such as non-IMRT, IMRT and SRS/SBRT, and perform quality assurance. For domestic, however, there are lack of guidelines and reports of Korean Society of Medical Physicists (KSMP) for reference to establish systematic QA report in medical institutes. This report, therefore, suggested comprehensive quality assurance system such as the scheme of quality assurance system, which is considered for domestic conditions, based the notification of NSSC and AAPM TG-142 reports. We think that the quality assurance system suggested for medical linear accelerator also help establishing QA system for another high-precision radiation treatment machines.

Improved Acroparesthesia During Enzyme Replacement Therapy in a Patient Lately Diagnosed with Fabry Disease (진단이 지연된 Fabry 병 환자에서 효소대체요법을 통한 사지 말단 동통의 호전을 보인 1례)

  • Yang, Aram;Kim, Jinsup;Cho, Sung Yoon;Jin, Dong-Kyu
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.17 no.3
    • /
    • pp.92-95
    • /
    • 2017
  • Fabry disease (FD) is an X-linked lysosomal storage disorder caused by an ${\alpha}$-galactosidase A (GLA, MIM 300644) enzyme deficiency due to pathogenic variants in the ${\alpha}$-galactosidase A gene (GLA). The disease leads to accumulation of globotriaosylceramide (Gb3) and related glycophospholipids affecting nearly all major organ systems, with the primary sites damaged by Gb3 including renal glomeruli, myocardium, neurons of the dorsal ganglion and autonomic nervous system, and vascular endothelial and smooth muscle. Progressive deposition in these organ systems present with various clinical manifestations including acroparesthesia, renal failure and heart failure. Here, we report a Chinese male diagnosed with Fabry disease in his late $4^{th}$ decades showing improvement of acroparesthesia during enzyme replacement therapy (ERT). A 48-year-old Chinese man who presented with chronic recurrent severe burning pain in his fingers and toes since the age of 10, with worse involvement of the former visited to our clinic for further evaluation. His medical history included a transient ischemic attack aged 40 and diagnosed with stage 4-5 chronic kidney disease aged 47. In the family history, the patient's brother was found to be have Fabry disease 1 month before his visit. Except for his brother, all other members of the family are healthy. Based on his medical history and family history, he was strongly suspicious for Fabry disease. He was found to have a galactose-alpha-1,3-galactose level 4.96 (Reference range, 42.5-67.9) suggestive of Fabry disease. The followed sequencing of GLA coding region in our patient revealed hemizyosity for the mutation c.988C>T (Q330X) in Exon 7. Since ERT start, he showed significant improvement in his symptoms of burning sensation of fingers and toes. On the contrary, due to deteriorating kidney function even with ERT, he is considered for kidney transplantation. Despite of diagnostic delay until late 4th decades, ERT showed a potential improvement of acroparesthesia in our patient. However, late start of ERT can lead to poor outcome in multiorgan function. Therefore, early diagnosis with high index of suspicion followed by continuous ERT with regular monitoring have an impact on quality of life in Fabry disease.

  • PDF

Effect of Antihypertensive Peptides Originated from Various Marine Proteins on ACE Inhibitory Activity and Systolic Blood Pressure in Spontaneously Hypertensive Rats (어육단백질로부터 분리된 항고혈압 펩타이드가 ACE 저해활성과 본태성 고혈압쥐의 혈압에 미치는 영향)

  • Do, Jeong-Ryong;Heo, In-Sook;Jo, Jin-Ho;Kim, Dong-Su;Kim, Hyun-Ku;Kim, Seong-Su;Han, Chan-Ku
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.4
    • /
    • pp.567-570
    • /
    • 2006
  • This study was carried out to investigate the effect of antihypertensive peptides originating from marine proteins on ACE inhibitory activity and systolic blood pressure in spontaneously hypertensive rats (SHR). Sixteen male SHR (SHR/NCrj) weighing approximately 270 g were randomly divided into few experimental groups based on diet: C (control), A (anchovy), P (pollack) and M (mackerel). The final body weights of P and M groups were higher, than those of C and A groups, but difference was not significant. Average reference blood pressure (RBP) was 224 mmHg at 12 weeks old. Compared with RBP, final systolic blood pressure of the marine peptide oops after 28 days of feeding with anchovy, pollack and mackerel fractions by gavage was decreased by 9.0% (A), 10.2% (P) and 14.3% (M), respectively, but was not different in C. Especially, final blood pressure of M was lower by 32 mmHg than RBP. These results suggested that peptide originated from mackerel hydrolysate was considered to have an antihypertensive fraction as effective lowering of blood pressure in SHR.

A 0.31pJ/conv-step 13b 100MS/s 0.13um CMOS ADC for 3G Communication Systems (3G 통신 시스템 응용을 위한 0.31pJ/conv-step의 13비트 100MS/s 0.13um CMOS A/D 변환기)

  • Lee, Dong-Suk;Lee, Myung-Hwan;Kwon, Yi-Gi;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.3
    • /
    • pp.75-85
    • /
    • 2009
  • This work proposes a 13b 100MS/s 0.13um CMOS ADC for 3G communication systems such as two-carrier W-CDMA applications simultaneously requiring high resolution, low power, and small size at high speed. The proposed ADC employs a four-step pipeline architecture to optimize power consumption and chip area at the target resolution and sampling rate. Area-efficient high-speed high-resolution gate-bootstrapping circuits are implemented at the sampling switches of the input SHA to maintain signal linearity over the Nyquist rate even at a 1.0V supply operation. The cascode compensation technique on a low-impedance path implemented in the two-stage amplifiers of the SHA and MDAC simultaneously achieves the required operation speed and phase margin with more reduced power consumption than the Miller compensation technique. Low-glitch dynamic latches in sub-ranging flash ADCs reduce kickback-noise referred to the differential input stage of the comparator by isolating the input stage from output nodes to improve system accuracy. The proposed low-noise current and voltage references based on triple negative T.C. circuits are employed on chip with optional off-chip reference voltages. The prototype ADC in a 0.13um 1P8M CMOS technology demonstrates the measured DNL and INL within 0.70LSB and 1.79LSB, respectively. The ADC shows a maximum SNDR of 64.5dB and a maximum SFDR of 78.0dB at 100MS/s, respectively. The ABC with an active die area of $1.22mm^2$ consumes 42.0mW at 100MS/s and a 1.2V supply, corresponding to a FOM of 0.31pJ/conv-step.

A Study on the Unified Operation and Maintenance System of Irrigation Facilities in Korea - With Reference to the Survey Results on the Activities of Irrigation Fraternities in Chungnam Province - (농업용수리시설의 유지관리체제일원화에 관한 연구 - 충남지역 수리계 운영실태조사결과를 중심으로 -)

  • Kim, Sung-Min;Lim, Jae-Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.31 no.1
    • /
    • pp.53-75
    • /
    • 2004
  • This study is aimed at identifying the national economic value of the irrigation facilities by reviewing the existing papers on economic values of the irrigation facilities and presenting current status of dual O & M problems of the irrigation facilities. This study suggested the unified O & M system rather than continuing the existing dual O & M system of irrigation facilities based on the surveyed results of the activities of irrigation fraternities in Chungnam Province. The findings and proposals for the successful unified and mono O & M system of the irrigation facilities are as follows: (1) Total number of irrigation facilities in the nation accounts for 67,582, while the total length of irrigation and drainage canals amounted to about 174,259km. On account of the total length of structural canals was estimated at 31%, much losses of water and much O & M costs have been inevitable for the full irrigation rice culture. In spite of the past heavy investment for irrigation facilities, the ratio of rain-fed and partially irrigated paddy fields accounts for 23% in 2003. Both Korea Agricultural and Rural Infrastructure Corporation (KARICO) and the city and Gun Governments have managed the irrigation facilities separately by irrigation fraternities. The KARICO have commanded 59% of irrigation paddy area with 18% of the total irrigation facilities, while the city and Gun governments covered 41% of irrigation paddy area with 82% of the existing number of irrigation facilities representing small and medium scale. (2) The 1999 demand prices of irrigation water per ton expressed in 2000 constant market price was estimated at 388 won, the supply price was amounted to 184 won per ton. Considering the supply and demand curve of the irrigation water, the existing irrigation facilities could not satisfy the demand of irrigation water. (3) In 1999, total present added value of the irrigation facilities during the economic life accounted for 48 trillion won, while total supply cost was 44.7 trillion won. The marginal benefit and cost ratio of irrigation water was 1.08. (4) The total O & M cost per year amounting to 681.1 billion won have been required to maintain and repair the existing irrigation facilities in Korea. For the successful unified O & M of irrigation facilities covering whole irrigated paddy field in Korea, 950 billion won of O & M costs are required to keep up the marginal benefit of irrigation water as 2,800 billion won per year. The total O & M cost as 950 billion won should be allocated 40%, 380 billion won for O & M costs of irrigation facilities and 60%, 570 billion won for improvement of irrigation facilities. (5) The study investigated and reviewed the present O & M status of the irrigation facilities by small and medium irrigation fraternities. Most of the farmers belong to the irrigation fraternities preferred not only unified O & M but also KARICO take-over of the whole O & M activities of the irrigation facilities. The prevailing O & M cost per 10a expended by the Corporation was amounted to 104,890 won, while that of city and Gun governments was only amounted to 4,600 won per 10a. regarding the small amount of O & M cost expended by city and Gun governments, it is evident that the existing irrigation system have been managed ineffectively and deteriorated the facilities comparing that of KARICO. In conclusion, the Government could not satisfied the demand of irrigation water by suppling water with existing irrigation facilities. Therefore new additional investment and financial support for irrigation water development should be made to convert rain-fed and partially irrigated paddy fields into fully irrigated ones. The operation and maintenance cost should be supported to keep the marginal values of rice production of existing irrigation facilities in the national economy and to modernize the obsolete irrigation facilities. By unifying the existing dual O & M systems, all the farmers belong to the irrigated paddy fields have to be equally benefited and could be increased their farm income and be stabilized their rural lives.

  • PDF

Economic Analysis of the Livestock Manure Treatment System Using Life-Cycle Cost Technique (LCC 기법을 통한 가축분뇨처리시설의 경제성 분석)

  • Kim, J.H.;Cho, S.H.;Kwag, J.H.;Choi, D.Y.;Jeong, K.H.;Chung, U.S.;Chung, M.S.;Park, S.K.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.sup
    • /
    • pp.61-68
    • /
    • 2011
  • To assess the total cost with all stages of facilities, the feasibility of Life Cycle Cost (LCC) analysis was examined in this study to estimate the livestock manure treatment system and optimal decision making process. For the economic evaluation, the plant/equipment investment and annual operation cost of four Public Livestock Recycling Facilities, whose treatment capacity is 100 ton piggery manure per day, was compared. The initial cost was in the range of 2,699 million won to 3,202 million won, where T and E methods were highest and lowest, respectively. The annual operation cost was in the level of 378 million to 498 million won, which decreased in the following order : T method > J method > E method > B method. For the LCC analysis, 4.7% of interest rate, 3.13% of inflation rate, and 1.52% of net discount rate was considered by the data received from Bank of Korea and Statics Korea in the period of 2000 to 2009. Also, for the calculation of present value factor, the durable years of civil engineering & construction, machinery and electric instrument was 30 years, 10 years and 15 years, respectively. Based on these consideration, operation cost was in the range of 17,570 won/ton to 20,661 won/ton, and E method (17,570 won/ton) was economical and B method (20,661 won/ton) was non-economical. Though initial cost of T method was higher than that of B method, LCC analysis of T method was lower than that of T method due to the lower operation cost. Therefore, LCC analysis, which considers both initial cost and operation cost, is more reasonable evaluation method than either initial cost or annual operation cost. For the change of LCC analysis according to the uncertainty, the sensitivity analysis was carried out using fluctuation magnitude of discount rate in the period of 2000 to 2009. As a result, LCC analysis evaluated by discount rate was stable for the uncertain factors since the cost leadership did not change even though the sensitivity analysis varied. In summary, the economic evaluation using LCC analysis could be an efficient reference to choose the suitable livestock manure treatment plants. Furthermore, standardization of statement calculation for the actual cost analysis should be conducted and more detailed study is necessary to validate this summary. Therefore, the application of comprehensive technology evaluation, which considers LCC analysis, should contribute in obtaining objectivity and enhancing reliability for the 'Evaluation of Livestock Manure Treatment System and its Technology'.