• Title/Summary/Keyword: reed switch

Search Result 20, Processing Time 0.027 seconds

A Electrical Fire Disaster Prevention Device of High Speed and High Precision by using Semiconductor Switching Devices (반도체 스위칭 소자를 이용한 고속 고정밀의 전기화재 방재장치)

  • Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.423-430
    • /
    • 2009
  • Recently as the inactive response characteristics of the existing RCD used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper confirms the unreliability of the existing RCD by electrical fault simulator and proposes a EFDPD by using semiconductor switching devices and a high precision current sensor (namely, reed switch) for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The sensitive reed switch in the proposed EFDPD exactly detects the increased magnetic flux with the overload or the short current caused by a number of electrical faults, and the following, the self circuit breaker in EFDPD rapidly cuts off the system. The proposed EFDPD confirms the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker through various operation performance analysis. The proposed EFDPD can also prevent electrical disasters, like as electrical fires, which resulted from the malfunction and inactive response characteristics of the existing RCD.

Design and Manufacture of Position Indicator for Cryogenic Valve (극저온 밸브용 위치지시기 설계 및 제작)

  • Koh, Hyeon-Seok;Han, Sang-Yeop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.850-853
    • /
    • 2011
  • The position indicator for cryogenic valves used in space launch vehicle should have high reliability and accuracy. Because the valves operate in cryogenic environment, the position indicator has to measure the valve status independently of the environmental factor, such as moisture and external contamination. We have developed the position indicator using a permanent magnet and reed switches to satisfy these requirements. We analyzed the characteristics of a permanent magnet and reed switches, then selected the appropriate components for cryogenic temperature. The shape and position of components were also considered to measure the open/close information of valve accurately Finally, the position indicator was applied to the valve prototype model, and verified the feasibility of design parameters.

  • PDF

Electrical Fire Disaster Prevention Device of Double Protection using a High Precision Current Sensor in Low Voltage Distribution System (고정밀 전류센서를 이용한 저압배전계통 이중 보호용 전기화재 방재장치)

  • Kwak, Dong-Kurl;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.40-47
    • /
    • 2009
  • Nowadays the diversity and large-capacity of electric appliances are strong effect on electrical fires augment in an alarming way. But, as the inactive response characteristics of the existing RCD (Residual Current protective Device) used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper is confirmed the unreliability of the existing RCD by electrical fault simulator and is proposed a Electrical Fire Disaster Prevention Device (EFDPD) by using a high precision current sensor (namely, reed switch) for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The sensitive reed switch in the proposed EFDPD exactly detects the increased magnetic flux with the overload or the short current caused by a number of electrical faults, and the following, the EFDPD has double protection function which operates self circuit breaker or rapidly cuts off the existing RCD. The proposed EFDPD is confirmed the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker through various operation performance analysis. The proposed EFDPD can also prevent electrical disaster, like as electrical fires, which resulted from the malfunction and inactive response characteristics of the existing RCD.

Considerations on Improvement of Moving Properties for Magnetic Actuator Capable of Movement in Pipe

  • Izumikawa, Tomohiro;Yaguchi, Hiroyuki
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.263-267
    • /
    • 2011
  • The present paper proposes a novel cableless magnetic actuator with a new propulsion module that exhibits a very high thrusting force. This actuator contains an electrical inverter that directly transforms DC from button batteries into AC. The electrical DC-AC inverter incorporates a mass-spring system, a reed switch, and a curved permanent magnet that switches under an electromagnetic force. The actuator is moved by the inertial force of the mass-spring system due to mechanical resonance energy. The experimental results show that the actuator is able to move upward at a speed of 33 mm/s when using 10 button batteries when pulling a 10 g load mass. This cableless magnetic actuator has several possible applications, including narrow-pipe inspection and maintenance.

A Study on the Leakage Current Detection System of Lighting Installation Using IoT Technology (IoT를 기반한 조명설비 누전사고 감지시스템에 관한 연구)

  • Park, Kun-Young;Kwak, Dong-Kurl;Lee, Bong-Seob;Kim, Choon-Sam;Jeon, Ho-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.7-8
    • /
    • 2018
  • In this study, we develop a leakage current detection device of lighting installation. The reed switch using in proposed device is activated when the leakage current is generated. We also design a GUI system of a management computer using LabVIEW and administrator's mobile phone app based on IoT. As results, this study is to build an IoT convergence system and it aims to protect people and property by coping with leakage current fault in real time.

  • PDF

ANALYSIS AND OPTIMIZATION of INJECTION TIMING for AN ADVANCED COMPRESSED AIR ENGINE KIT

  • Kumar, Akshay;Kumar, Vasu;Gupta, Dhruv;Kumar, Naveen
    • International journal of advanced smart convergence
    • /
    • v.4 no.1
    • /
    • pp.54-63
    • /
    • 2015
  • Increasing air pollution levels and the global oil crisis has become a major hindrance in the growth of our automobile sector. Traditional Internal Combustion engines running on non-renewable fuels are proving to be the major culprit for the harmful effects on environment. With few modifications and also with assistance of few additional components current small SI engines can be modified into a pneumatic engine (commonly known as Compressed Air Engines) without much technical complications where the working fluid is compressed air. The working principle is very basic as adiabatic expansion of the compressed air takes place inside the cylinder pushing the piston downwards creating enough MEP to run the crank shaft at decent RPM. With the assistance of new research and development on pneumatic engines can explore the potential of pneumatic engines as a viable option over IC engines. The paper deals with analysis on RPM variation with corresponding compressed air injection at different crank angles from TDC keeping constant injection time period. Similarly RPM variation can also be observed at different injection pressures with similar injection angle variation. A setup employing a combination of magnetic switch (reed switch), magnets and solenoid valve is used in order to injection timing control. A conclusive data is obtained after detailed analysis of RPM variation that can be employed in newly modified pneumatic engines in order to enhance the running performance. With a number of benefits offered by pneumatic engine over IC engines such as no emissions, better efficiency, low running cost, light weight accompanied by optimized injection conditions can cause a significant development in pneumatic engines without any major alteration.

Development of Ubiquitous Telemetry Water Reading System Using RF and CDMA (RF와 CDMA를 활용한 상수도 원격검침시스템 개발)

  • Lho, Tae-Jung;Kim, Hwa-Il;Lee, Wook-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.2
    • /
    • pp.215-221
    • /
    • 2009
  • In recent, there has been progressed in various ways of research and development about a ubiquitous telemetry reading, but several problems are arising the reliability of reading value, power supply and so on. These issues were solved by using the RF module and digital pulse meter with photocoupler. Realized by this study, a telemetry reading system, utilizing RF and CDMA telecommunication, and check in real time the state of water leakage by managing the distinct usage data. In addition, the users can check it in person, and it can minimize the public enmities. Further, as a part of the silver industry fur constantly growing senior population, it might be introduced as safety supervision system.

Design and Fabrication of Digital Water Meter Using a Variable Capacitor (가변 콘덴서를 이용한 디지털 수도미터의 설계 및 제작)

  • Park, Keun-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.3
    • /
    • pp.141-146
    • /
    • 2016
  • The AMR(automatic meter reading) system has been increasingly and widely used for its efficient and intelligent management, which is a technology that automatically collects consumption data from a water meter or energy metering device. The digital meter instead of the mechanical meter should be used in the system. Up to now, various types of sensor to measure the water flow rate have been used in the digital water meter, for example, reed switch, photo IR approximate sensor, ultrasonic sensor, electromagnetic sensor, etc. In this paper, a new sensing technology, where a variable capacitor and digital circuit were used for sensing the water flow rate, was proposed. The circuit was designed and verified by Pspice simulation. And a PCB board for the circuit was fabricated. After then, a prototype of digital water meter using a variable capacitor to measure the water flow rate was fabricated. The function tests of the fabricated digital water meter were performed, and it was found that the meter worked properly. Since the new technology has much better properties in terms of cost and power consumption compared to conventional technologies, it should be one of the major digital water meter technologies in the future.

A study on AC over-current breaker using thyristor (Thyristor를 이용한 교류과전류 차단에 관한 연구)

  • 박민호;심재명
    • 전기의세계
    • /
    • v.28 no.7
    • /
    • pp.49-55
    • /
    • 1979
  • This paper describes the mechanisms which breaks A.C. over-current protection in low voltage load. For the high speed over-current protection, it consists of thyristor switching circuit by forced commutation, IC logic gate controlled circuit and over-current detector with reed switch. Under various duty conditions, breacker was carried out several experiments and discussions. The results are as follows; (1) over-current cut off is possible within a quarter cycle (4ms at 60Hz) and clear is at least ten times faster than its electromechanical equivalent. (2) as the forced commutation thyristor circuit breaker has capability of high speed break, equivalent surgy current capacity of switching thyristor is increased more than twenty times of its rated current. (3) breaker using solid state dose not produce any harmful arc during switching period. Therefore the breaker above described may be considered an effective over-current protector for soli state power devices in industrial applications.

  • PDF

Identifiable life vest signal generator in case of marine accident (해양사고 시 식별 가능한 구명조끼용 신호발생 장치)

  • Bang, Gul-Won
    • Journal of Digital Convergence
    • /
    • v.20 no.5
    • /
    • pp.317-322
    • /
    • 2022
  • In general, life jackets are worn by people in critical situations on the water to rise to the surface without falling into water, and life jackets simply serve to prevent sinking, but do not actively help rescue disaster areas in critical situations early. In order to solve this problem, a device that automatically generates a distress signal in an emergency situation was developed. When the survivor is in hand for a while, the distress signal generator is automatically separated from the life jacket, allowing information such as location values and other information to be transmitted wirelessly and a rescue signal using LED light. As a result of the experiment, when submerged in water, the life jacket and the distress signal generator were automatically separated, and the result of wireless transmission of the coordinate value of the location received by the GPS was confirmed. By using this, the location of the distress or missing person can be identified, which can be quickly replaced in case of an emergency