• Title/Summary/Keyword: reduction to the pole

Search Result 144, Processing Time 0.021 seconds

A Study on the Pole-Q Reduction of Chebyshev Function Using Trade-off (트레이드 오프를 이용한 Chebyshev 함수의 극점-Q 감소에 관한 연구)

  • 윤창훈;최석우
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.79-83
    • /
    • 2000
  • When passband ripple α/sub p/ and stopband attenuation α/sub s/ at the w/sub s/ where the stopband begins are specified in filter design, △α/sub s/ usually exceeds the specification by △α/sub s/ due to the necessity that the order n of the filter function be an integer. In this paper, we apply a trade-off method to remove the excess stopband attenuation △α/sub s/ for reducing the value of pole-Q and improving the characteristics of the Chebyshev filter function. We also apply the trade-off method of pole-Q reduction to the modified Chebyshev function, and then the 4 types of function have been analyzed to compare in frequency and time domain characteristics. The trade-off method reduces the pole-Q which influences the filter characteristics to maximum 49.6% without increase of the order n. Thus implies that they have the improved characteristics such as the reduced passband ripple and flatter delay characteristics as compared Chebyshev filter function before trade-off. And the unit step response shows shorter delay time and settling time in time domain performance.

  • PDF

A Study of the Pole Change Method of the Single-Phase Induction Motor for Capability Variation (능력가변을 위한 단상유도전동기의 극수변환 방법에 관한 연구)

  • Kim, Gyu-Heon;Jung, Tae-Uk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.499-505
    • /
    • 2020
  • Capacitor-run single-phase induction motor is cheaper than motors that use permanent magnets and is widely used in home appliances and industries based on relatively high durability and productivity. It can also be operated by line. However speed cannot be controlled because the line frequency is free. In this paper we dealt pole change method one of the method controlling speed of capacitor-run single-phase induction motor. The conventional pole change method is difficult to improve the power and efficiency of the motor because the composition of the pole change device is complex and do not have enough area of the windings because of windings not used according to the driving conditions. In this paper, we proposed the pole change method that is used main windings and auxiliary windings at 4 poles operation and used auxiliary windings as compensation windings at 2 poles operation. The proposed method was verified through finite element analysis.

Rotor Pole Design and Characteristics Analysis of the Bearingless Switched Reluctance Motor Considering Fringing Flux (프린징 자속을 고려한 베어링리스 SRM 회전자극 설계 및 특성분석)

  • Lee, Chan-Kyo;Oh, Ju-Hwan;Shin, Kwang-Chul;Kwon, Byung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.57-64
    • /
    • 2010
  • In this paper, a novel Bearingless Switched Reluctance Motor(BLSRM) with the shoe rotor pole in order to minimize the torque ripple and the suspension force ripple at an overlap position is proposed. For reduction the torque ripple and the suspension force ripple at an overlap position, the fringing flux is used for the main flux. This configuration of the rotor pole results in more average torque with high suspension force. In addition, this paper is compared the transient characteristics using the inductance look-up table. The torque, radial force and flux density are analyzed by finite element method.

Optimal Design of a PMLSM with 9 Pole 10 Slot for Detent Force Reduction (9극 10슬롯 구조의 영구자석 선형 동기 전동기의 디텐트력 저감을 위한 최적설계)

  • Hwang, In-Sung;Yoon, Hee-Sung;Koh, Chang-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.589-595
    • /
    • 2008
  • Detent force of a permanent magnet linear motor(PMLSM) consist of cogging and drag forces, and should be minimized for high precision control purpose applications. This paper shows that the cogging force can be reduced effectively by employing 9 pole 10 slot structure. The drag force is minimized by optimizing the total length and shape of the exterior teeth of armature core simultaneously by using($1+{\lambda}$) evolution strategy coupled with response surface method. After optimization, the optimized PMLSM is proven to reduce 95% and 92.6% of the cogging and total detent forces, respectively, and give 12% and 6.4% higher Back-emf and thrust force, respectively, compared with a conventional 12 pole 9 slot structure under the same condition. Additionally, Simulation results by the proposed optimum design are verified by the experiment results.

Study of the Reduction of Torque Ripples for Multi-pole Interior Permanent Magnet Synchronous Motors using Rotor Saliency (회전자 돌극 설계를 이용한 다극 매입형 영구자석 동기전동기의 토크리플 저감 연구)

  • Kim, Ki-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.6270-6275
    • /
    • 2014
  • The paper reports an improvement method on torque ripples of multi-pole interior permanent magnet synchronous motor (IPMSM) applied to a traction motor for hybrid electric vehicles. In the case of multi-pole IPMSM, the magnetic flux generated by a permanent magnet tends to leak through the bridge of the rotor without a link with stator windings. The slit design on the rotor surface was proposed to reduce torque rippling and increase the output power by reducing the leakage flux. Two design parameters for the slit are suggested for optimal design using the response surface method. As an analysis method, the 2D finite element method (FEM) was applied to consider magnetic saturation effect.

A study on the Development of the Shell-type Pole Transformer Using the Zig-Zag Winding (Zig-Zag 귄선에 의한 내철형 주상변압기 개발에 관한 연구)

  • Min, Yun-Hong;Shin, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.121-128
    • /
    • 2007
  • In this thesis, we would show how to lay out and produce the shell-type transformer using the world's first Zig-Zag winding way, instead of a general winding. Also, we omit the progress of varnish-impregnation, so that we could develop the new shell-type transformer winding which improves the short-circuit characteristics and dielectric strength. It has a copernican effect to reduce the thickness and the number of insulation papers, as compared with a general winding transformer. We would prove that it is far superior in cost reduction, loss reduction, and mechanical force of short-circuit. And eventually you must find it useful in the pole transformer for power distribution in the domestic power companies.

Design of Cogging Torque and Torque Ripples Reduction for High Precision Controlled SPMSM (정밀제어용 표면부착형 영구자석 동기전동기의 코깅토크 및 토크리플 저감 설계)

  • Kim, Chang-Ki;Lee, Sang-Gon;Jung, Sang-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1923-1929
    • /
    • 2009
  • The design of SPMSM(surface mounted permanent magnet synchronous motor) has been performed to reduce cogging torque and torque ripples. In general, cogging torque and torque ripples are affected by the shapes of teeth width, yoke depth, magnet pole arc, etc. Particularly, the minimum design point of cogging torque and torque ripples are different so that the design of SPMSM should be done to compromise both of them for precision application. In this paper, the design of PMSM for EPS(electric power steering) system is performed to verify the validity, and the design characteristics versus teeth width, yoke depth, and magnet pole arc are investigated in order to find out the minimum point of cogging torque and torque ripples. In addition, skew of PM is applied for cogging torque reduction.

Seismic response of active or semi active control for irregular buildings based on eigenvalues modification

  • Pnevmatikos, Nikos G.;Hatzigeorgiou, George D.
    • Earthquakes and Structures
    • /
    • v.6 no.6
    • /
    • pp.647-664
    • /
    • 2014
  • A reduction of the response of irregular structures subjected to earthquake excitation by control devices equipped by suitable control algorithm is proposed in this paper. The control algorithm, which is used, is the pole placement one. A requirement of successful application of pole placement algorithm is a definition-selection of suitable poles (eigen-values) of controlled irregular structures. Based on these poles, the required action is calculated and applied to the irregular structure by means of control devices. The selection of poles of controlled irregular structure, is a critical issue for the success of the algorithm. The calculation of suitable poles of controlled irregular structure is proposed herein by the following procedure: a fictitious symmetrical structure is considered from the irregular structure, adding vertical elements, such as columns or shear walls, at any location where is necessary. Then, the eigen-values of symmetrical structure are calculated, and are forced to be the poles of irregular controlled structure. Based on these poles and additional damping, the new poles of the controlled irregular structure are calculated. By pole placement algorithm, the feedback matrix is obtained. Using this feedback matrix, control forces are calculated at any time during the earthquake, and are applied to the irregular structure by the control devices. This procedure results in making the controlled irregular structure to behave like a symmetrical one. This control strategy can be applied to one storey or to multi-storey irregular buildings. Furthermore, the numerical results were shown that with small amount of control force, a sufficient reduction of the response of irregular buildings is achieved.

Influence of time delay and saturation capacity to the response of controlled structures under earthquake excitations

  • Pnevmatikos, Nikos G.;Gantes, Charis J.
    • Smart Structures and Systems
    • /
    • v.8 no.5
    • /
    • pp.449-470
    • /
    • 2011
  • During the last thirty years many structural control concepts have been proposed for the reduction of the structural response caused by earthquake excitations. Their research and implementation in practice have shown that seismic control of structures has a lot of potential but also many limitations. In this paper the importance of two practical issues, time delay and saturation effect, on the performance of controlled structures, is discussed. Their influence, both separately and in interaction, on the response of structures controlled by a modified pole placement algorithm is investigated. Characteristic buildings controlled by this algorithm and subjected to dynamic loads, such as harmonic signals and actual seismic events, are analyzed for a range of levels of time delay and saturation capacity of the control devices. The response reduction surfaces for the combined influence of time delay and force saturation of the controlled buildings are obtained. Conclusions regarding the choice of the control system and the desired properties of the control devices are drawn.

Discrete model reduction over disc-type analytic domains (디스크형태의 해석적영역을 가지는 이산모델 차수축소)

  • 오도창;정은태;이갑래;박홍배
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.5
    • /
    • pp.27-34
    • /
    • 1998
  • This paper is on the discrete model reduction method over disc-type analytic domains. We define hankel singular value over the disc that is mapped by standard bilinear mapping. And the generalized singular perturbation approximation and the direct truncation are generalized to GSPA and DT over a disc. Furthermore, it is shown that the reduced order model over a smaller domaing has a smaller .inf.-norm error bound. And the poposed reduction method is used to obtain the regional pole placement property.

  • PDF