• Title/Summary/Keyword: reduction cleaning

Search Result 229, Processing Time 0.022 seconds

Cleaning Interval Selection for SCR Considering Endurance Reliability and Emissions Reduction Efficiency in Heavy Duty Commercial Engine (대형 상용 엔진에서 SCR의 클리닝 주기 선정 및 저감효율에 따른 내구신뢰성 특성 연구)

  • Shin, Jaesik;Kang, Jungho;Kim, Hyongjun
    • Journal of Applied Reliability
    • /
    • v.18 no.1
    • /
    • pp.66-71
    • /
    • 2018
  • Purpose: Performance recovered from SCR through cleaning was studied, measuring differential pressure, NOx reduction efficiency, fuel consumption and engine power before and after cleaning. Ideal cleaning intervals are proposed based on SCR mileage and differential pressure. SCR endurance and reliability improvements through cleaning were studied through physicochemical testing of SCR durability at 43,000km 50,000km, and 110,000km respectively. Methods: Engine power, fuel consumption and exhaust gas were measured using engine full load tests and ND-13 MODE by installing the SCR before cleaned at total engine mileages of 400,000 km, 300,000km and 200,000km. The same tests were performed after cleaning the SCR catalytic converter. Endurance and reliability of the SCR cleaning was studied through the same test by SCR catalyst after each 43,000km 50,000km, 110,000km, durability test on SCR cleaning. Conclusion: We confirmed the low-performance of the SCR due to clogging is restored by SCR cleaning technology. The NOx reduction efficiency was restored to 82%, 86% and 88% from 69%, 72% and 79%. As well as the NOx reduction efficiency, it was confirmed that the engine power, fuel consumption and back pressure was restored to fresh SCR levels. As a result of the durability and reliability achieved through SCR cleaning, we confined the appearance and reduction efficiency through visual inspection and ND-13 MODE are similar to new SCR catalysts. Finally, it was judged that there was no change in performance even when driving the SCR without cleaning throughout the 100,000 km mileage warranty.

Reduction Cleaning and Thermomigration Effects on Micro Polyester SUEDE (극세 폴리에스테르 스웨드의 환원세정과 열이행의 영향)

  • Choi, Kyung-Yeon;Han, Sam-Sook;Lee, Mun-Cheul
    • Textile Coloration and Finishing
    • /
    • v.21 no.6
    • /
    • pp.12-21
    • /
    • 2009
  • The dyeing property of direct-spinning type and seaisland type 0.2D micro polyester nonwoven fabrics was characterized by three disperse dyes (Dorosperse Red KFFB, Blue KGBR, Yellow KRL) at $120^{\circ}C$ and $130^{\circ}C$. Before and after reduction cleaning, dyeing fastness was evaluated and the thermomigaration after heat setting at $180^{\circ}C$ for 60 min were also evaluated. Direct-spinning type fabric showed better dyeing property, wash fastness, and light fastness, but worse rub fastness than seaisland type fabric. The dyeing property and fastness of direct-spinning type fabric increased at higher dyeing temperature, whereas seaisland type fabric exhibited lower dyeing fastness and the increase of thermomigration at higher dyeing temperature. Non-fixed dye in fiber surface was removed by reduction cleaning process, then dyeing fastness was improved and thermomigration decreased. The higher dye uptake of direct-spinning type non-woven fabric caused the increase of dye molecule migration from fiber internal to fiber surface, so this fabric showed larger thermomigration than seaisland type non-woven fabric.

Field Application of an Alternative Cleaning Agent to Methylene Chloride (Methylene Chloride의 대체세정제 적용 사례 연구)

  • 배재흠;신민철;이통영;조기수
    • Journal of Surface Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.109-124
    • /
    • 1999
  • A study for replacing methylene chloride for an alternative cleaning agent which can be utilized for cleaning aluminium parts of hard disk drives was carried out at Suwon factory of Samsung Electro-mechanics Co. Ltd. As a result, quite a good cleaning agent was selected through data collection of alternative cleaning agents, their analysis of environment effects and safty factors and testing of their cleaning power. As compared with methylene chloride, the selected cleaning agent has better cleaning power. It is also more environmental-friendly, less toxic and more economical. And the operating cost reduction due to adoption of this alternative cleaning agent in Samsung Electro-mechanics Co. Ltd. was more than ₩l46,000,000 annually without any capital instrument in addition to improvement of environmental and safty conditions in the plant.

  • PDF

A Study on the removal of Metallic Impurities on Si-wafer using Electrolyzed Water (전해수를 이용한 실리콘 웨이퍼 표면의 금속오염 제거)

  • Yoon, Hyo-Seob;Ryoo, Kun-Kul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.1-5
    • /
    • 2000
  • As the semiconductor devices are miniaturized, the number of the unit cleaning processes increases. In order to processes by conventional RCA cleaning process, the consumption of volume of liquid chemical and DI water became huge. Therefore, the problem of environmental issues are evolved by the increased consumption of chemicals. To resolve this matter, an advanced cleaning process by Electrolyzed Water was studied in this work. The electrolyzed water was made by an electrolysis equipment which was composed of three chambers of anode, cathode, and middle chambers. In the case of electrolyzed water with electrolytes in the middle chamber, oxidatively acidic water of anode and reductively alkaline water of cathode were obtained. The oxidation/reduction potentials and pH of anode water and cathode water were measured to be +l000mV and 4.8, and -530mV and 6.3, respectively. The Si-wafers contaminated with metallic impurities were cleaning with the electrolyzed water. To analysis the amounts of metallic impurities on Si-water surfaces, ICP-MS(Inductively Coupled Plasma-Mass spectrometer) was introduced. From results of ICP-MS measurements, it was concluded that the ability of electrolyzed water was equivalent to that of the conventional RCA cleaning.

  • PDF

The Effect on Fouling Reduction by the Ball Cleaning System in a Compressed Type Refrigerator

  • Lee, Yoon-Pyo;Karng, Sarng-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.2
    • /
    • pp.88-96
    • /
    • 2002
  • The present study was conducted to estimate the effect on fouling reduction in tubes of the condenser. It shows in detail how to calculate the fouling factor from the experimental results of refrigeration systems with or without the automatic cleaning system using sponge balls and to predict the variation of the factor with time. It also represents how to calculate the temperature and pressure decrease of the refrigerant vapor in the condenser and the load decrease of the compressor in the refrigeration system by fouling reduction.

Improving the Fading of Reusable Surgical Gown by Repeated Severe Laundering and Sterilization Condition (반복되는 고온 세탁 및 멸균 환경에 대한 Reusable 수술가운 원단의 퇴색 저항성 개선 연구)

  • Kim, Ji Yeon;Min, Mun Hong;Yeum, Jeong Hyun
    • Textile Coloration and Finishing
    • /
    • v.25 no.3
    • /
    • pp.215-222
    • /
    • 2013
  • The purpose of this study is to minimize fading fabrics of surgical gown by repeated severe laundering and sterilization condition. The study showed that the best conditions were reduction cleaning using sulphinic acid derivatives or glucose organic chemicals at $98^{\circ}C$ alkaline solutions. In these conditions, color difference values(dE) were below 1.0 that means unrecognizable color change by repeated laundering and sterilization. If it treated with only laundering, reduction cleaning conditions may adjust over $80^{\circ}C$ alkaline solution. In conclusion, it is needed to select the high-washing fastness dye and reduction cleaning using sulphinic acid derivatives or glucose organic chemicals at $98^{\circ}C$ alkaline solutions for removal unfixed dyes.

Leakage Current Reduction of Ni-MILC Poly-Si TFT Using Chemical Cleaning Method

  • Lee, Kwang-Jin;Kim, Doyeon;Choi, Duck-Kyun;Kim, Woo-Byoung
    • Korean Journal of Materials Research
    • /
    • v.28 no.8
    • /
    • pp.440-444
    • /
    • 2018
  • An effective cleaning method for Ni removal in Ni-induced lateral crystallization(Ni-MILC) poly-Si TFTs and their electrical properties are investigated. The HCN cleaning method is effective for removal of Ni on the crystallized Si surface, while the nitric acid treatment results decrease by almost two orders of magnitude in the Ni concentration due to effective removal of diffused Ni mainly in the poly-Si grain boundary regions. Using the HCN cleaning method after the nitric acid treatment, re-adsorbed Ni on the Si surfaces is effectively removed by the formation of Ni-cyanide complexions. After the cleaning process, important electrical properties are improved, e.g., the leakage current density from $9.43{\times}10^{-12}$ to $3.43{\times}10^{-12}$ A and the subthreshold swing values from 1.37 to 0.67 mV/dec.

Fouling and cleaning of a tubular ultrafiltration ceramic membrane

  • Siddiqui, Farrukh Arsalan;Field, Robert W.
    • Membrane and Water Treatment
    • /
    • v.7 no.5
    • /
    • pp.433-449
    • /
    • 2016
  • The successful application of cleaning protocols is vital for optimized filtration processes. A series of experiments with an ultrafiltration ceramic tubular membrane were carried out for the foulants dextran and carboxymethyl cellulose. Firstly, the impact on fouling of concentration changes was investigated with the increase in resistance being used as the key parameter. In the second phase, removal of reversible fouling was also investigated by employing intermittent rinsing consisting of a cold water rinse followed by a hot one. A comparative analysis for both foulants is reported. Across a range of concentrations and for both foulants, the reduction in resistance due to rinsing was found to depend upon concentration (C); it changed as $C^n$ where n was found to be 0.3. A plausible semi-theoretical explanation is given. Thirdly, for both foulants, the application of a combination of strong alkaline solutions with oxidizing agent (mainly sodium hypochlorite) followed by acid was found to be appropriate for cleaning of the ceramic membrane. The effect of increased temperature for cleaning agents followed by a warm water rinse contributed positively to the cleaning capability.

Optimization of chemical cleaning of discarded reverse osmosis membranes for reuse

  • Jung, Minsu;Yaqub, Muhammad;Lee, Wontae
    • Membrane and Water Treatment
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • This study optimized the chemical cleaning process of discarded RO membranes for reuse in less demanding separation processes. The effect of physicochemical parameters, including the temperature, cleaning time, pH of the cleaning solution, and addition of additives, on the cleaning process was investigated. The membrane performance was evaluated by testing the flux recovery rate and salt rejection before and after the cleaning process. High temperatures (45-50 ℃) resulted in a better flux recovery rate of 71% with more than 80% salt rejection. Equal time for acid and base cleaning 3-3 h presented a 72.43% flux recovery rate with salt rejection above 85%. During acid and base cleaning, the best results were achieved at pH values of 3.0 and 12.0, respectively. Moreover, 0.05% concentration of ethylenediaminetetraacetic acid presented 72.3% flux recovery, while 69.2% flux was achieved using sodium dodecyl sulfate with a concentration of 0.5%; both showed >80% salt rejection, indicating no damage to the active layer of the membrane. Conversely, 0.5% concentration of sodium percarbonate showed 83.1% flux recovery and 0.005% concentration of sodium hypochlorite presented 85.2% flux recovery, while a high concentration of these chemicals resulted in oxidation of the membrane that caused a reduction in salt rejection.

Feasibility Study for Introducing Window Cleaning Device (유리창 청소작업의 자동화 장비 도입에 대한 타당성 분석)

  • Kim, Kyoon-Tai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.612-618
    • /
    • 2020
  • In recent years, the demand for external window cleaning has increased, but the process is a very dangerous manpower-dependent operation. In addition, it is difficult to clean at the desired frequency in a business that values cleanliness. Therefore, there is a need to automate this work. This paper presents the concept of a device that can be attached to a specific window and clean the window continuously. The economic feasibility of this device was analyzed. The estimated manufacturing cost of the equipment was approximately 10 million won, but the possible investment cost was at least 9.8 million won for five years of endurance and 103 million won for 10 years of endurance. Therefore, the expected savings well exceed the equipment cost, and it was evaluated as having economic feasibility. Since this study analyzed only quantitative indicators, the expected cost reduction due to a reduction in safety accidents, productivity improvement, construction time reduction, and quality improvement was not considered. Therefore, it is expected that the calculated economic feasibility will be more accurate if the cost reduction effect by the automation equipment is calculated by adding the expected values not considered in this study.