• 제목/요약/키워드: reduction DC voltage

검색결과 270건 처리시간 0.025초

단상 액티브 파워 필터를 위한 새로운 전류 보상 방법 (A New Current Compensation Estimation Method For Single Phase Active Power Filter)

  • 곽상신;이무영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.819-822
    • /
    • 1998
  • A new active power filter (APF) circuit with a current compesation estimation method is proposed. The current compensation estimation method replaces a current sensor with an estimating circuit and therefore reduces the implementation cost In addition, a simple control scheme, based on the energy balance concept, is adopted to control the voltage of a DC capacitor. Therefore energy change in the DC capacitor can be compensanted in the next cycle. Since a sampling technique is used, a larger DC capacitor voltage ripple can be permissible and a relatively smaller DC capacitor can be used. The proposed method has advantages of the reduction of one current sensor, low implementation cost, and fast transient responses. The theoretical analysis and simulation results are given. The proposed control method is successfully verified by computer simulation.

  • PDF

전류형 인버터의 리액터 경감을 위한 태양광발전시스템 (Photovoltaic System for the DC Reactor Reduction of the Current Source Inverter)

  • 박인덕;성낙규;이승환;강승욱;이훈구;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.484-486
    • /
    • 1997
  • In this paper, we compose of the utility phovoltaic system with the stepdown chopper and the current source inverter to reduce pulsation of dc current and dc reactor. We study that control several ways(twice frequency of utility voltage square pulse and without the chopper) of chopper part. Therefore if voltage across the dc reactor equal to zero, it is decreased. And we control modulation factor of the chopper to operate at maximum power point around of solar cell.

  • PDF

계통 연계형 풍력 발전 시스템의 LVRT 제어 전략 (LVRT Control Strategy of Grid-connected Wind Power System)

  • 신호준;설승기
    • 전력전자학회논문지
    • /
    • 제16권2호
    • /
    • pp.182-190
    • /
    • 2011
  • 본 논문은 계통 전압 사고 상황에서 계통 연계형 풍력 발전 시스템이 만족시켜줘야 할 LVRT(Low Voltage Ride Through) 제어 전략을 제안한다. LVRT 규정은 계통 전압 사고 시 풍력 발전 시스템이 지켜야 할 부분들을 전압 감소율과 사고 시간에 대해 나타내고 있다. 특히 전압 감소율이 10% 이상일 경우에는 풍력 발전 시스템은 규정된 무효 전류를 전력 계통에 제공하여 계통 전압 확보에 이바지해야 한다. 본 논문에서의 LVRT 규정은 세계적으로 가장 엄격한 규정인, 독일 계통 연계 규정(German Grid Code)을 기준으로 하고 풀 스케일(Full-scale) 가변 속도 전력 변환 시스템을 고려하여 제어 전략을 수립한다. 본 LVRT 제어 전략은 계통 사고 시 LVRT 규정을 모두 만족시킴과 동시에 직류단 전압 제어의 추가적인 알고리즘으로 직류단 전압의 제어를 통하여 전체 풍력 발전 시스템의 전력 균형을 기할 수 있다. 3상 전압 지락 사고의 경우 계통으로의 전력 제어가 불가능하여 계통 측 컨버터가직류단 전압을 제어할 수 없으므로, 전력 제어의 기능을 발전기 측 인버터로 이행 시켜 상황에 따라 유연한 직류단 전압 제어가 가능함을 보였다. 시뮬레이션과 실험을 통해 LVRT 제어 전략의 타당성을 검증하였다.

13kW급 고주파 ZVS FB DC-DC 콘버터 개발 (A Study on the Development of A 13kW High Frequency ZVS FB DC-DC Converter)

  • 김은수;조기연;이재훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.542-546
    • /
    • 1994
  • The objective of the study is to design and develope a 13kW zero voltage switching DC-DC Converter far high power application. Due to using the snubber capacitor in the right leg instead of increasing transformer leakage inductance, DC characteristics and the total efficiency in the proposed ZVS DC-DC converter is increased mere than in the conventional ZVS DC-DC converter by reduction of the circulating current when the load current is large. Also, this paper includes simulation and experimental results of the proposed ZVS FB DC-DC converter.

  • PDF

고주파 소프트 스위칭 Forward DC/DC 컨버터 (High Frequency Soft Switching Forward DC/DC Converter)

  • 김은수;최해영;조기연;김윤호
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.19-25
    • /
    • 1999
  • 본 연구는 새로운 영전압, 영전류 스위칭 Forward 컨버터에 관한 것으로 종래의 하드 스위칭(Hard-Switching) Forward 컨버터에 있어서 Turn-off 및 Turn-off시 발생되는 스위칭 손실 및 출력 다이오드 역회복 특성에 따른 손실증가와 스위칭시 발생되는 기생진동을 Forward 컨버터에 있어서 1차측 주 스위칭소자 및 2차측 출력 정류다이오드와 병렬로 무손실 스너버를 적용함으로써 Forward 컨버터의 1차측 스위칭 소자의 Turn-off 및 Turn-on시 영전압, 영전류 스위칭을 이룰 수 있고, 출력 정류다이오드도 영전압, 영전류 스위칭 됨으로 다이오드의 역회복손실 및 기생 진동에 따른 EMI(Electro-Magnetic Interference)를 줄일 수 있는 무손실 스너버 적용 영전압, 영전류 스위칭 Forward 컨버터에 관한 것이다.

계통 연계형 풍력발전 시스템의 고조파 저감 및 무효전력 보상 (Reduction of Harmonics and Compensation of Reactive Power about Wind Power Generation System Connected to Grid)

  • 김영민;황종선;김종만;박현철;송승호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.1093-1096
    • /
    • 2002
  • In this paper, a novel multi voltage inverter system is proposed for reductions of harmonics, which can compensate reactive power. At first, we remove capacitor at input side for reactive power compensation. Secondly, by adding DC voltage to the filter capacitor, it can control power factors as lead-phase according to alterations of loads at power reception. Thirdly, if winding and single phase-bridge inverter(auxiliary circuit) is installed to DC power for reduction of harmonic, waveform of output voltages become to 36-steps. Thus, SVC(static var compensator) systems which can reduce harmonics are designed.

  • PDF

개선된 전압제어를 이용한 BLDC 전동기의 토크맥동저감 (Reduction of Torque Ripple in a BLDC Motor Using an Improved Voltage Control)

  • 송정현;장진석;김병택
    • 제어로봇시스템학회논문지
    • /
    • 제16권2호
    • /
    • pp.145-150
    • /
    • 2010
  • This paper deals with reduction of torque ripple in a brushless DC motor with input voltage control. The commutation torque ripple can be controlled with varying input voltage, but cogging torque is independent on it. So, in this paper a strategy for minimizing torque ripple is proposed by offsetting the cogging torque with deliberate voltage control. The optimal condition is determined with variable voltage levels and advance angles. As results, it is shown that the method causes 63% decrease of torque ripple.

DC링크 전류센서를 이용한 삼상전류 측정 방식에서 최소 스위칭 시간의 단축 (Reduction of Minimum Switching Duration in the Measurement of Three Phase Current with DC-Link Current Sensor)

  • 김경서
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권12호
    • /
    • pp.649-654
    • /
    • 2003
  • The simplest method for measuring output currents of the three phase inverters is to measure them with three current sensors such as hall sensors. This method requires at least two current sensors, and these types of sensors are somewhat expensive. More economical method is measuring DC link current with a simple shunt resistor, then, reconstructing output current using the DC link current value and the switching status. However, in low speed region, the measurement becomes difficult and even impossible due to the requirement of minimum switching duration for A/D conversion. These problems can be overcome by limitation of switching duration. Limitation of switching, however, causes voltage and current distortion. Owing to compensation, distortion can be effectively suppressed. However these increase acoustic noise due to increment of current ripple. In this paper, a current measurement method is proposed, which can reduce minimum switching duration resulting in reduction of acoustic noise. The validity of proposed method is confirmed through experiment.

다상 DC-DC 컨버터의 입력 전류 리플 저감 제어 알고리즘 (Input Current Ripple Reduction Algorithm for Interleaved DC-DC Converter)

  • 주동명;김동희;이병국
    • 전력전자학회논문지
    • /
    • 제19권3호
    • /
    • pp.220-226
    • /
    • 2014
  • Input current ripple and harmonic components of the power device are main causes of electromagnetic interference (EMI). Although the discontinuous conduction mode (DCM) operation can reduce harmonic components of the power device by reducing reverse recovery current of diode and turn-off voltage spikes of the switch, input current ripple increases due to high peak to peak inductor current. Therefore, in this paper, frequency control algorithm is proposed to reduce the input current ripple of DCM operated interleaved boost converter. In the proposed algorithm, duty ratio is fixed either 0.33 or 0.67 to minimize the input current ripple and the switching frequency is controlled according to operating conditions. 600 W 3-phase interleaved boost converter prototype system is built to verify proposed algorithm.

3-레벨 인버터의 DC 링크 전압 밸런싱과 누설전류 저감을 위한 PWM 제어방법 (PWM Control Method for DC link Voltage Balancing and Leakage Current Reduction in 3-level Inverter)

  • 최남섭;이은철;안강순
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 추계학술대회 논문집
    • /
    • pp.137-138
    • /
    • 2015
  • 본 논문에서는 3-레벨 인버터 시스템의 DC 링크 전압 밸런싱과 동시에 공통모드 전압의 변동주파수를 최소화 하여 누설 전류를 저감하는 새로운 PWM 방법을 제안한다. 제안된 PWM은 공통모드전압과 중간점 제어능력에 따라 공간벡터를 분류하고 중간점 전압을 제어하면서 공통모드 전압의 변동이 최소화되는 벡터를 선택하도록 구성한다. 본 논문에서는 시뮬레이션을 통하여 제안된 PWM의 동작을 입증하였다.

  • PDF