• 제목/요약/키워드: reduced beam section

검색결과 120건 처리시간 0.028초

깊이 1200mm급 변단면보의 중간모멘트골조용 내진접합부 개발 (Beam-Column Connection with 1200mm Deep Multi-Reduced Taper Beam for Intermediate Moment Frame)

  • 정시화;알미아이유 로벨 원디므;박만우;주영규
    • 대한건축학회논문집:구조계
    • /
    • 제35권4호
    • /
    • pp.135-146
    • /
    • 2019
  • Deep beam has high section modules compared with shallow beam of the same weight. However, deep beam has low rotational capacity and high possibility of brittle failure so it is not possible to apply deep beams with a long span to intermediate moment frames, which should exhibit a ductility of 0.02rad of a story drift angle of steel moment frames. Accordingly, KBC and AISC limit the beam depth for intermediate and special moment frame to 750mm and 920mm respectively. The purpose of this paper is to improve the seismic performance of intermediate moment frame with 1200mm depth beam. In order to enhance vulnerability of plastic deformation capacity of deeper beam, Multi-Reduced Taper Beam(MRTB) shape that thickness of beam flange is reinforced and at the same time some part of the beam flange width is weakened are proposed. Based on concept of multiple plastic hinge, MRTB is intended to satisfy the rotation requirement for intermediate moment frame by dividing total story drift into each hinge and to prevent the collapse of the main members by inducing local buckling and fracture at the plastic hinge location far away from connection. The seismic performance of MRTB is evaluated by cyclic load test with conventional connections type WUF-W, RBS and Haunch. Some of the proposed MRTB connection satisfies connection requirements for intermediate moment frame and shows improved the seismic performance compared to conventional connections.

Rotation capacity of composite beam connected to RHS column, experimental test results

  • Eslami, Mohammadreza;Namba, Hisashi
    • Steel and Composite Structures
    • /
    • 제22권1호
    • /
    • pp.141-159
    • /
    • 2016
  • Commonly in steel frames, steel beam and concrete slab are connected together by shear keys to work as a unit member which is called composite beam. When a composite beam is subjected to positive bending, flexural strength and stiffness of the beam can be increased due to "composite action". At the same time despite these advantages, composite action increases the strain at the beam bottom flange and it might affect beam plastic rotation capacity. This paper presents results of study on the rotation capacity of composite beam connected to Rectangular Hollow Section (RHS) column in the steel moment resisting frame buildings. Due to out-of-plane deformation of column flange, moment transfer efficiency of web connection is reduced and this results in reduction of beam plastic rotation capacity. In order to investigate the effects of width-to-thickness ratio (B/t) of RHS column on the rotation capacity of composite beam, cyclic loading tests were conducted on three full scale beam-to-column subassemblies. Detailed study on the different steel beam damages and concrete slab damages are presented. Experimental data showed the importance of this parameter of RHS column on the seismic behavior of composite beams. It is found that occurrence of severe concrete bearing crush at the face of RHS column of specimen with smaller width-to-thickness ratio resulted in considerable reduction on the rate of strain increase in the bottom flange. This behavior resulted in considerable improvement of rotation capacity of this specimen compared with composite and even bare steel beam connected to the RHS column with larger width-to-thickness ratio.

언더텐션 시스템이 적용된 축소 실험체의 구조적 성능에 대한 연구 (Experimental Investigation of Large-Span Girder with Under-Tension System)

  • 김영민;박대하;이기학;이재홍
    • 한국강구조학회 논문집
    • /
    • 제22권4호
    • /
    • pp.345-354
    • /
    • 2010
  • 기존의 빔과 거더로 이루어진 장스팬 구조물의 경우 기둥 사이의 거리가 길기 때문에 부재의 크기와 수직 처짐이 증가하게 된다. 효과적인 장스팬 구조물의 실현을 위하여 구조물 하부에 스트럿과 케이블로 구성된 언더텐션시스템을 적용하였다. 이는 거더의 휨모멘트를 효과적으로 분산시키기 때문에 부재의 크기를 줄이고 경제적인 효과를 기대할 수 있다. 또한 급속시공을 위한 폐단면 신형상의 모듈화 PF500단면을 사용하여 성능을 검증하고자 하였다. 언더텐션 시스템의 성능검증을 위하여 가로 10m, 세로 2.4m의 실험체 두개를 대상으로 가력실험을 실시하였고 언더텐션 시스템 유무와 케이블 장력변화에 따른 거동을 확인하였다. 실험으로부터 케이블 장력이 증가함에 따라 실험체의 거동이 작아졌으며 언더텐션 시스템이 하중분배 역할을 수행하는 것으로 나타났고 PF500단면의 성능이 우수함을 나타내었다.

Numerical cyclic behavior of T-RBS: A new steel moment connection

  • Ataollahi, Saeed;Banan, Mohammad-Reza;Banan, Mahmoud-Reza
    • Steel and Composite Structures
    • /
    • 제21권6호
    • /
    • pp.1251-1264
    • /
    • 2016
  • After observing relatively poor performance of bolted web-welded flange beam-to-column connections during 1994 Northridge earthquake, various types of connections based on two concepts of: (i) strengthening the connection; and (ii) weakening the beam ends were proposed. Among these modified or newly proposed connections, bolted T-stub connection follows the concept of strengthening. One of the connections with the idea of weakening the beam ends is reduced beam section (RBS). In this paper, finite element simulation is used to study the cyclic behavior of a new proposed connection developed by using a combination of both mentioned concepts. Investigated connections are exterior beam-to-column connections designed to comply with AISC provisions. The results show that moment capacity and dissipated energy of the new proposed connection is almost the same as those computed for a T-stub connection and higher than corresponding values for an RBS connection.

Seismic behavior of coupled wall structure with innovative quickly replaceable coupling beams

  • Li, Yong;Yu, Haifeng;Liang, Xiaoyong;Yu, Jianjun;Li, Pengcheng;Wang, Wei;Wang, Qizhi
    • Steel and Composite Structures
    • /
    • 제45권2호
    • /
    • pp.293-303
    • /
    • 2022
  • In order to improve the seismic resilience of coupled wall structure, coupling beam with fuse has been developed to reduce the post-earthquake damage. However, the fuses often have a build-up I-shaped section and are relatively heavy to be replaced. Moreover, the fuse and the beam segments are usually connected by bolts and it is time-consuming to replace the damaged fuse. For reducing the repair time and cost, a novel quickly replaceable coupling beam with buckling-restrained energy dissipaters is developed. The fuse of the proposed coupling beam consists of two chord members and bar-typed energy dissipaters placed at the corners of the fuse. In this way, the weight of the energy dissipater can be greatly reduced. The energy dissipaters and the chords are connected with hinge and it is convenient to take down the damaged energy dissipater. The influence of ratio of the length of coupling beam to the length of fuse on the seismic performance of the structure is also studied. The seismic performance of the coupled wall system with the proposed coupling beam is compared with the system with reinforced concrete coupling beams. Results indicated that the weight and post-earthquake repair cost of the proposed fuse can be reduced compared with the typical I-shaped fuse. With the increase of the ratio of the beam length to the fuse length, the interstory drift of the structure is reduced while the residual fuse chord rotation is increased.

Cone Beam형 CT와 파노라마 영상에서 하악궁의 영상 왜곡 분석 (Analysis of Image Distortion by Mandibular Arch Form in Cone Beam CT and Panoramic Image)

  • 정천수;이기흔
    • 한국방사선학회논문지
    • /
    • 제7권4호
    • /
    • pp.301-305
    • /
    • 2013
  • Cone Beam CT 데이터를 3차원 컴퓨터 프로그램을 이용하여 기존의 파노라마 영상과 재구성된 파노라마 영상을 재현해서 악궁형태에 따른 치아의 왜곡을 분석하고자 하였다. Cone Beam CT의 횡단면 영상과 재구성 파노라마에서 측정된 치아의 직경은 전치부에서 구치부로 갈수록 큰 변화없이 일치되는 것을 알 수 있었다. 하지만 파노라마는 전치부에서 약간의 왜곡이 보이다가 구치부로 갈수록 왜곡이 더 심한 것을 알 수 있었다. 환자 개개인의 악궁에 맞게 재구성된 파노라마가 일반적으로 사용되는 파노라마 촬영보다 왜곡이 더 감소한다는 것을 알 수 있었다. 또한 파노라마는 전치부에서 구치부로 갈수록 왜곡이 더 심해지는 것을 알 수 있었는데, 이 또한 재구성된 파노라마 영상에서는 왜곡이 감소한다는 것을 알 수 있었다.

반력모멘트를 이용한 라멘형 철골구조물의 거동분석 (Behavior Analysis of RMPM Applied Steel Frame Structures)

  • 안진희;김준환;김태연;김상효;이상우
    • 한국강구조학회 논문집
    • /
    • 제19권6호
    • /
    • pp.611-620
    • /
    • 2007
  • 일반적인 중력하중 재하상태의 라멘구조에서는 보-기둥의 이음부에 최대 부모멘트가 발생하며, 일반적으로 이음부의 최대 부모멘트가 보 중앙의 최대 정모멘트보다 크게 나타나므로 보와 기둥의 이음부에서의 모멘트에 의하여 보의 단면이 결정된다. 그러나 보와 기둥의 이음부에 의하여 라멘구조물의 단면을 설계하면 보의 중앙부는 단면과대설계가 되어 단면의 효율성이 낮아지므로, 이음부의 부모멘트를 감소시켜 보 전체의 응력을 고르게 분포시키면 보다 효율적인 단면설계가 가능하게 된다. 본 연구에서는 라멘구조물의 최대 부모멘트 구간에 부재력 재분배 효과로써 보 전체의 응력을 고르게 분포시키고 단면을 감소시킬 수 있는 새로운 시공방법으로써 반력모멘트를 이용한 라멘구조물의 프리스트레싱 공법을 제안하고자 한다. 반력모멘트는 프리스트레싱에 의하여 휨모멘트가 도입된 보부재를 기둥과 연결한 후, 도입된 프리스트레스를 제거할 시에 라멘구조물에 발생하는 반력을 이용하여 보와 기둥의 이음부에서 발생하는 최대 부모멘트를 감소시키고 부재력을 보 전체에 고르게 분배하여 구조물의 내하성능을 증진시키는 공법이다. 본 연구에서는 제안된 반력모멘트를 이용한 철골구조물의 프리스트레싱 도입 공법의 검증을 위하여 실험적 검증 및 구조해석을 실시하여, 반력모멘트에 의한 라멘구조물의 부재력 재분배 효과 및 효율성을 확인하였다.

RBS 철골모멘트접합부의 내진거동평가를 위한 반복재하 실물대(實物大) 시험 (Cycllic Seismic Testing of Full-Scale RBS (Reduced Beam Section) Steel Moment Connections)

  • 이철호;전상우;김진호
    • 한국강구조학회 논문집
    • /
    • 제14권4호
    • /
    • pp.557-566
    • /
    • 2002
  • 본 논문은 4개의 철골모멘트 접합부에 대한 반복재하 실물대(實物大) 실험결과를 요약한 것이다. 주요 실험변수는 기둥과 보의 접합방식 (볼트접합 대 용접) 및 패널존의 강도 (강한 패널존 대 중간강도 패널존)이다. 중간 패널존 강도를 갖는 시험체는 패널존과 RBS 영역 모두에서 균형잡힌 방식으로 에너지가 소산되도록 고려하여 설계된 것으로 패널존 보강비용을 줄이고자 시도한 경우이다. 보웨브가 용접으로 접합된 경우의 시험체들은 특별연성모멘트골조에 요구되는 충분한 접합부 회전성능을 보여 주었지만, 웨브를 볼트로 접합한 시험체들은 스캘럽을 가로지르는 보플랜지의 조기 취성파괴로 인해 열등한 내진성능을 노출하였다. 보웨브를 볼트로 접합하면 비용을 줄일 수 있으나 원래 보단면의 전소성모멘트를 기둥에 전달하기 어려운 것으로 나타났다. 본 연구에서 적용된 것과 같이 양질의 용접시공에 의해 일단 그루브 용접부 자체의 취성파괴 문제가 해결되고 나면, 용접접근공내에 위한 보플랜지 모재의 파단이 다음의 문제로 대두됨을 알 수 있다. 용접접근공 내의 보 플랜지 파단문제를 역학적인 측면에서 이해하는데 도움이 되는 해석적 연구도 수행되었다.

Welded Flange-Bolted Web 강접합부의 파괴모드 추정을 위한 유한요소해석 (Finite Element Analysis for the Failure Mode of Welded Flange-Bolted Web Connection)

  • 조창빈
    • 한국지진공학회논문집
    • /
    • 제3권4호
    • /
    • pp.33-46
    • /
    • 1999
  • 캘리포니아의 강구조 모멘트프레임은 1994년 노스리지 지진시 6.8의 규모와 진앙지에서 근접한 지리적인 악조건에도 불구하고 붕괴나 인명피해 없이 잘 견뎌냈다. 그러나 이후 시행된 조사에서 경제적으로 지진시 안전하다고 믿어져 널리 쓰인 welded flange-bolted web(WFBW) 강접합부(moment connection)의 기둥과 용접의 경계면에서 취성 파괴가 다수 발견되었다. 이논문은 선형파괴역학과 노스리지진이후의 WFBW 강접합부 실험을 이용하여 WFBW 강접합부와 노스리지지진이후 기존 강접합부의 대안으로 추천되고 있는 reduced beam section (RBS) 강접합부의 취성 파괴강도를 결정하는 수치적인 방법을 제안하고 이를 이용하여 이들 강접합부의 취성 파괴모드를 추정하였다.

  • PDF

층고 절감을 위한 하이브리드 보의 휨 거동에 관한 실험적 연구 (Flexural Behavior of Hybrid Beam of Reduced Story Height)

  • 홍성걸;양동현;정종현;임병호
    • 콘크리트학회논문집
    • /
    • 제19권5호
    • /
    • pp.557-567
    • /
    • 2007
  • 아파트의 지하주차장은 보 아래로 각종 설비 배관이 배치되기 때문에 층고가 $300{\sim}400mm$ 정도 추가로 필요하다. 본 연구에서는 설비 배관에 의한 층고 증가를 방지할 수 있도록 설비 배관이 배치되는 부분의 깊이를 줄이고 대신 강재 보를 매입하여 보강한 PC 보의 상부를 현장콘크리트로 타설하여 마무리하는 하이브리드 보 (hybrid beam)를 제안하였다. 그리고 이 하이브리드 보의 휨 거동을 검토하기 위해서 강재 의의 형상, 보의 깊이를 줄인 부분의 길이, 시공 단계 및 콘크리트 양생 후인 합성 단계, 슬래브 및 전단연결재 포함 여부 등을 주요 실험 변수로 실물 실험체 9개를 제작하고 휨 실험을 수행하였다. 그 결과, 본 연구에서 제안한 하이브리드 보는 합성 단계인 경우 강재 보의 형상, 보의 깊이를 줄인 부분의 길이, 슬래브 및 전단연결재의 포함 여부에 관계없이 설계 내력을 상회하는 우수한 휨 거동을 보여주는 것을 확인하였다. 시공 단계에서는 구조적 안정성 및 시공 품질의 확보를 위하여 가설 지지대 (support)가 필요한 것으로 판단된다.