Abstract
In spite of 6.8 magnitude and the neighborhood of the epicenter, the steel moment frame survived after Northridge earthquake without collapse or casualties. However, following investigation revealed that there were severe damages at the column-weld interface of welded flange-bolted web (WFBW) steel moment connection, which was believed to be economic and safe from earthquakes based on experience and past tests. In this paper, this unexpected brittle fracture of the steel moment connection is explored using linear elastic fracture mechanics and post-Northridge tests. A method to predict the brittle fracture strength of the steel moment connection is proposed. Using this method, the failure mode of the WFBW connection and reduced beam section (RBS) connection are presented.
캘리포니아의 강구조 모멘트프레임은 1994년 노스리지 지진시 6.8의 규모와 진앙지에서 근접한 지리적인 악조건에도 불구하고 붕괴나 인명피해 없이 잘 견뎌냈다. 그러나 이후 시행된 조사에서 경제적으로 지진시 안전하다고 믿어져 널리 쓰인 welded flange-bolted web(WFBW) 강접합부(moment connection)의 기둥과 용접의 경계면에서 취성 파괴가 다수 발견되었다. 이논문은 선형파괴역학과 노스리지진이후의 WFBW 강접합부 실험을 이용하여 WFBW 강접합부와 노스리지지진이후 기존 강접합부의 대안으로 추천되고 있는 reduced beam section (RBS) 강접합부의 취성 파괴강도를 결정하는 수치적인 방법을 제안하고 이를 이용하여 이들 강접합부의 취성 파괴모드를 추정하였다.