• Title/Summary/Keyword: recycling water

Search Result 1,065, Processing Time 0.029 seconds

Practical Use of Activated Recycling Water Sludge for Admixture of Concrete (활성도를 부여한 회수수 슬러지의 콘크리트 혼화재 활용)

  • Kim, Ho-Su;Baek, Chul-Woo;Park, Cho-Bum;Jeun, Jun-Young;Ryu, Deug-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.777-780
    • /
    • 2008
  • There were some attempt to reuse water with sludge combinative water for ready mixed concrete. But recycling water consist of cement, aggregate and chemical admixture. So it caused deterioration of concrete. The object of this study was to search for recycling method of the recycling water sludge as mineral admixture. This experiment dealed with the effect of $2.5{\sim}12.5$% range of the recycling sludge which can be used for admixture binder(BFS, FA, BFS+FA) on properties of activated recycling water sludge for admixture of concrete. As a result, Although the slump levels reduced and air contents increased as sludge replacement levels increased, it didn't change highly. The compression strength of concrete slightly increased with an increasing amount of recycling water sludge replacement.

  • PDF

The Fluidity and Comprssive Strength Properties of Lightweight Mortar Using Recycling Water according to Blast Furnace Slag Powder Ratio (고로슬래그미분말 혼입율에 따른 회수수 사용 경량모르타르의 유동성 및 강도특성)

  • Bae, Sung Ho;Lee, Jae In;Kim, Ji Hwan;Oh, Tae Gue;Choi, Se Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.136-137
    • /
    • 2020
  • This study compared and analyzed the fluidity and strength characteristics of mortar using the recycling water, indicates strong alkali properties, as pre-wetting water of artificial light aggregate to increase usage ratio of recycling.

  • PDF

Recycling of Wastepaper(Ⅷ)-Contamination of Process WAter by System Closure (고지재생연구(제 8보) -제지 공정수 폐쇄화에 따른 오여-)

  • 여성국;류정용;신종호;송봉근;오세균
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.31 no.4
    • /
    • pp.1-7
    • /
    • 1999
  • This study was carried out to simulate the change of various properties of recycled water when zero-discharge system was applied to a KOCC recycling process. contaminants such as chemical oxygen demand, anionic trash, and calcium hardness were gradually increased in the process water as the recycling was repeated . Especially, the increase of anionic trash and COD were closely related to the starch derived from corrugating adhesive in KOCC. Four kinds of water were compared in the preparation of handsheet to evaluate the performance of retention program. Waters used in this work were laboratory tab water, process water from Dong-II mill and the same one treated by UASB process, and closed white water prepared by KRICT. The result revealed that one the major factors fro reducing a retention power was the anioni trash accumulated in the recycled water.

  • PDF

A Study on the Effect of the Perception of Water Reuse on Water Reuse Practice Intention (물 재이용에 대한 인식이 물 재이용 실천의도에 미치는 영향)

  • Lim, Sang-Ho;Han, Moo-Young
    • Industry Promotion Research
    • /
    • v.1 no.1
    • /
    • pp.137-142
    • /
    • 2016
  • This study verified the effect of the perception of water reuse on water reuse practice intention. The study results showed that the perception of water reuse practice necessity, the effect of water recycling toilet(p<.01), compulsory installation of water recycling product in public institution, expansion of compulsory installation of water recycling product, the law of water reuse promotion and support(p<.05). Also, monthly household income, occupation and monthly water rate significantly affected the between-group differences of water reuse practice intention. This study provided implications for operating water reuse policy by analyzing the effect of the perception of water reuse on water reuse practice intention to enhance water reuse practice.

Application and evaluation for effluent water quality prediction using artificial intelligence model (방류수질 예측을 위한 AI 모델 적용 및 평가)

  • Mincheol Kim;Youngho Park;Kwangtae You;Jongrack Kim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.1
    • /
    • pp.1-15
    • /
    • 2024
  • Occurrence of process environment changes, such as influent load variances and process condition changes, can reduce treatment efficiency, increasing effluent water quality. In order to prevent exceeding effluent standards, it is necessary to manage effluent water quality based on process operation data including influent and process condition before exceeding occur. Accordingly, the development of the effluent water quality prediction system and the application of technology to wastewater treatment processes are getting attention. Therefore, in this study, through the multi-channel measuring instruments in the bio-reactor and smart multi-item water quality sensors (location in bio-reactor influent/effluent) were installed in The Seonam water recycling center #2 treatment plant series 3, it was collected water quality data centering around COD, T-N. Using the collected data, the artificial intelligence-based effluent quality prediction model was developed, and relative errors were compared with effluent TMS measurement data. Through relative error comparison, the applicability of the artificial intelligence-based effluent water quality prediction model in wastewater treatment process was reviewed.

Analysis of Operational Plan and Economical Validity in Aquacultural for Contingency Red Tide (적조 대응 육상양식장 운영방안 및 경제적 타당성 분석)

  • Lee, Kwang-Nam
    • The Journal of Fisheries Business Administration
    • /
    • v.47 no.3
    • /
    • pp.35-52
    • /
    • 2016
  • This paper analyzed economic feasibility of aquacultural construction which of large-scale. The results of the economic analysis, cage cultural and water recycling cultural by post-water treatment were analyzed that NPV is 2,083,685 thousand won and -14,105,896 thousand won and B/C ratio is 0.590 and 0.855, respectively. These were shown economic infeasibility. But, running water culture by pre-water treatment(small scale) and running water culture by pre-water treatment(large scale) were analyzed that the one is 5,555,747 thousand won and 15,048,589 thousand won and the other is 1,154 and 1,1221, respectively. these were shown economic feasibility. In addition, measurement of B/C ratio through a sensitivity analysis on running water cultural by pre-water treatment(small scale) and running water cultural by pre-water treatment(large scale) is economic feasibility in all cases. However, these were analyzed when the selling price was falling to 20 percent, it has shown economic infeasibility and when the selling price rises to 20 percent, water recycling culture by post-water treatment has economic feasibility. The significance of the study analyzed a sensibility as well as economic feasibility by methods and scales. It is expected that used as basic materials when constructing and operating of land aquaculture in order to minimize the damage from natural disasters.

Control of Soybean Sprout Rot Caused by Pythium deliense in Recirculated Production System

  • Yun, Sung-Chul
    • The Plant Pathology Journal
    • /
    • v.19 no.6
    • /
    • pp.280-283
    • /
    • 2003
  • A soybean-sprout rot epidemic occurred in a mass production soybean sprout factory in 2000 and 2001 in Korea, which caused up to 20% production loss. Among the causal pathogenic bacteria and fungi, Pythium deliense was found to be the dominant pathogen of severe root and hypocotyls rot, particularly in recirculating water system. An average of 90% of the isolated fungi from the rotted sprout on potato dextrose agar were Pythium sp. The fungal density of Pythium in the sampled water was monitored in the recycled water system for 1 year using a selective medium (com meal agar with Pimaricin, 10 mg; Rifampicin, 10 mg; and Ampicillin, 100 mg per 1 liter). The drained water from the soybean-sprout cultivation always had a certain amount of fungus in it. The removal of Pythium from the recycling water system must be thorough, safe, and environment friendly. However, the pathogen in the water was easily found even after ozone and chlorine treatments, which were devised on the recycling system for the removal of microorganisms. 5-$\mu\textrm{m}$ pore size filter was applied and was able to successfully control the disease. As the sprout industry increasingly shifts into mass production, the demand for water will increase continuously. Recycling water for sprout production is eco-friendly. However, a process must be devised to be able to first decompose organic matters before Pythium zoospores are filtered.

Biodegradation Rate of Recycling Soap Prepared from Non-Cooking Oils (폐식용유로 제조된 재생비누의 생분해 속도)

  • 신춘환;김희숙;허근태
    • Journal of Environmental Science International
    • /
    • v.5 no.1
    • /
    • pp.83-91
    • /
    • 1996
  • A recycling soap was prepared from non-cooking oils. The effects of physlcal and chemical properties of the recycling soap on biodegradation are expected to be different due to the thermal histories of the non-cooking oils. Therefore, the biodegradation rate of the recycling soap was studied by using Klebssella Pneumoniae(K. pneumoniae), and the growth rate of K. pnewoniae in soap solution was observed. The biodegradation rate of the recycling soap appeared to be slower as the thermal histories of the non-cooking oils became larger. This might be resulted from hydrolysis, in which the ester bonds in the oils are broken to produce hydroxyl group. It was also observed that the growth rate of the microorganism decreased with the increase in the thermal histories of the oils. As a result, it is desired that recycling soap should be produced from the non-cooking oils with the prober ranges of thermal histories to reduce water contamination. The non-cooking oils with larger thermal histories are considered to be recycling through the cracking process before used. Key Words : non-cooking oils, recycling soap, thermal history, biodegradation, microorganism growth.

  • PDF

Effluents from copper industry: Improvised techniques

  • Duraisamy, Sankar;Saminathan, Rajagopal;Narsimman, Deepa
    • Membrane and Water Treatment
    • /
    • v.6 no.2
    • /
    • pp.103-112
    • /
    • 2015
  • In India, recycling of treated effluent plays a major role in the industry. Particularly in copper industry, recycling techniques for treated effluents adopt conventional technologies which are not energy efficient and recovery of high quality process water, free flowing salts and sludge's is very low. This paper presents an overview of enhanced modern technology for treated effluents in copper industry making it more efficient with high recovery of high quality process water and free flowing salts. Life cycle cost (LCC) would be 15-20% lower than the conventional technologies. The conventional technology can be replaced with this proposed technique in the existing and upcoming copper industries.

Recovery Increase by Recycling Backwash Residuals in Microfiltration System

  • Yu, Myong-Jin;Pak, Hong-Kyoung;Sung, Il-Wha
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.13-21
    • /
    • 2008
  • With the rise in membrane applications, residuals management has become a growing challenge for membrane system. The primary residuals of MF/UF (microfiltration/ultrafiltration) system results from the wastes generated during backwashing. Many regulatory agencies, utilities, and water process engineers are unfamiliar with the characteristics and methods for treatment and disposal of membrane residuals. Therefore, this study was performed to investigate the backwash residuals water quality from the pressurized system with and without pre-coagulation, and to suggest approaches for the backwash residuals treatment. Pressurized MF system was installed at Guui water intake pumping station and operated with raw water taken from the Han River. We compared performances with and without the recycling backwash residuals at flux conditions, 50 LMH and 90 LMH with and without pre-treatment (coagulation). Based on the results, recycling of backwash residuals in pressurized system with pre-coagulation showed applicability of backwash residuals managements. Moreover, the recovery rate also increased up to over 99%.