0.57의 L/D 비를 가지는 폭발챔버에서 전파하는 화염과 다중 장애물의 상호작용에 관한 실험적 연구 (Experimental Studies on the Interactions between Propagating Flames and Different Multiple Obstacles in an Explosion Chamber with a L/D Ratio of 0.57)

  • 박달재
    • 한국안전학회지
    • /
    • 제27권6호
    • /
    • pp.70-77
    • /
    • 2012
  • Experimental investigations were performed to examine the characteristics of propagating flame fronts around multiple bars within a rectangular chamber. The explosion chamber is 400 mm in height, $700{\times}700mm^2$ in cross-section and has a large top-venting area, $A_v$, of $700{\times}210mm^2$. This results in a value of 0.44 for $A_v/V^{2/3}$ and a L/D value of 0.57. The multiple obstacles of length 700 mm with a blockage ratio of 30 % were placed within the chamber. Temporally resolved flame front images were recorded by a high speed video camera to investigate the interaction between the propagating flame and the obstacles. Results showed that the flame propagation speeds before the flame impinges onto the obstacle almost equal to the laminar burning velocity. As the propagating flame impinged on the obstacle, the central region of flame began to become concave, this resulted in the flame deceleration in the region. As the flame interacted with the modified flow filed generated behind the central obstacle, the probability density functions(PDFs) of the local flame displacement speed were extensively distributed toward higher speeds.

박리가 발생된 적층평판의 압축 거동에 관한 연구 (A Study on compressive behavior of laminated plates with initial delamination)

  • 이남주;조용욱
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제5회(2016년)
    • /
    • pp.167-174
    • /
    • 2016
  • Recently laminated plates like composite materials has been used in a various field to grow the specific strength of the composition. However, delamination area caused by barely visible impact damage has potential risk that it can raise buckling of the delaminated plate. Because it can interrupt compressive behavior of laminated plates and reduce their strength, the whole structure can't be constituted by these materials. Many studies assume that behavior of the delaminated plate which is in lamanated plates equals theoretical buckling but their actual motion doesn't coincide because of initial imperfections of materials like deflection, residual stress, eccentricity and so on. In this paper, we change laminated plates with initial delamination into a beam of rectangular cross section with the initial crack and analyze compressive behavior according to initial imperfections through finite element method(FEM). Consequently analysis results show that behavior of laminated plates involving delamination differs from ideal buckling of the delaminated plate in actual conditions and we can predict its motion through imperfections relationship.

  • PDF

연속주조 압출 ZK60A 합금의 고온 기계적 특성 (High Temperature Mechanical Properties of Continuous Cast and Extruded ZK60A Alloy)

  • 안병민
    • 소성∙가공
    • /
    • 제23권3호
    • /
    • pp.178-183
    • /
    • 2014
  • Continuous casting is a process where molten metal is solidified into a semi-finished billet on a large scale with either a rectangular or round cross section for subsequent processing. The use of continuous casting provides an opportunity for producing material on a practical industrial scale with lower cost than conventional casting. In the current study, the material was fabricated by continuous casting and subsequent extrusion. Tensile tests were conducted on continuous cast ZK60A after extrusion over a range of strain rates at temperatures from 473K to 623K. The alloy exhibits a quasi-superplastic behavior with a maximum recorded elongation of ~250% at 523K when tested with an initial strain rate of $10^{-5}/s$. The experiments give a strain rate sensitivity exponent of 0.3~0.4 and an activation energy of 108 kJ/mol. From the current investigation, it was found that the high-temperature plastic flow of the ZK60A is controlled by a dislocation viscous glide mechanism.

四角리브를 갖는 傳熱面에 衝突하는 2次元 噴流의 熱傳達에 관한 硏究 (Heat Transfer of a Two-Dimensional Jet Impinging on the Wall with Transverse Repeated Ribs of Square Cross-Section)

  • 김상필;서정윤
    • 대한기계학회논문집
    • /
    • 제11권2호
    • /
    • pp.214-221
    • /
    • 1987
  • 본 논문에서는 2차원충돌분류에서 사각리브(rib)를 갖는 요철형전열면에 대한 실험에 관한 것이며, 리브의 높이를 (e=5nm) 일정하게 하고 리브의 피치(p=25,35,50 nm) 변화, 노즐출구와 전열면간 거이(H/B=1~14) 및 노즐출구유속(u$_{e}$=12.30~ 18.07m/s)의 변화에 따른 전열특성을 실험적으로 구명하고 평판전열면의 경우와 비교 검토한다. 또한 스모크와이어(smoke-wire)법으로 평판 및 리브판에서의 유체의 거동 을 가시화하여 전열기구의 정성적 특성을 검토하는데 목적이 있다.

2차원(次元) 충돌분류(衝突噴流)의 열전달(熱傳達) 증진(增進)에 관(關)한 실험적(實驗的) 연구(硏究) (사각(四角) Rib폭(幅)의 효과(效果)) (Augmentation of Heat Transfer by two Dimensional Impinging Air Jet (Effect of Square Rib Width))

  • 이용화;이관석;서정윤
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.350-356
    • /
    • 1988
  • The impinging air jet system is still being used in the various fields with its inherent merits, that is, the easiness in engineering application and high heat transfer coefficients at stagnation point. The purpose of this study is augmentation of heat transfer without additional power in the rectangular air jet which impinges vertically to the heating surface. As a method of passive heat transfer augmentation in a two-Dimensional impinging jet, the transverse-repeated surface roughness of square cross-section is used. This paper deals with the experimental study on the characteristics of heat transfer at the x-direction in between nozzle exit and heating surface of flat plate, and that of ribbed plate. And this study also investigates the effect of square rib widths. The integral average heat transfer coefficient of ribbed plate is about 2.2 times larger than that of flat plate.

  • PDF

REDUCED DIFFERENTIAL TRANSFORM FOR THERMAL STRESS ANALYSIS UNDER 2-D HYPERBOLIC HEAT CONDUCTION MODEL WITH LASER HEAT SOURCE

  • SUTAR, CHANDRASHEKHAR S.;CHAUDHARI, KAMINI K.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제25권2호
    • /
    • pp.54-65
    • /
    • 2021
  • In this study, a two-dimensional thermoelastic problem under hyperbolic heat conduction theory with an internal heat source is considered. The general solution for the temperature field, stress components and displacement field are obtained using the reduced differential transform method. The stress and displacement components are obtained using the thermal stress function in the reduced differential transform domain. All the solutions are obtained in the form of power series. The special case with a time-dependent laser heat source has been considered. The problem is considered for homogeneous material with finite rectangular cross-section heated with a non-Gaussian temporal profile. The effect of the heat source on all the characteristics of a material is discussed numerically and graphically for magnesium material taking a pulse duration of 0.2 ps. This study provides a powerful tool for finding the solution to the thermoelastic problem with less computational work as compared to other methods. The result obtained in the study may be useful for the investigation of thermal characteristics in engineering and industrial applications.

유한 요소법에 의한 구형단면의 온도분포와 Computational Effort에 관한 연구 (A Study on the Temperature Distribution and Computational Effort of Rectangular Cross-Section by the Finite Dynamic Element Method)

  • 용호택
    • 대한설비공학회지:설비저널
    • /
    • 제13권2호
    • /
    • pp.10-15
    • /
    • 1984
  • The aims of this study are to obtain a suitable method and a proper mesh for investigation of the temperature distribution and heat transfer. The relative errors of temperature distribution and heat transfer for each mesh are acquired in accordance with linear finite element (FEM 3), square finite element (FEM 6), cubic finite element (FEM 10), and finite difference method (FDM). It has been found that FEM 10 is the most accurate measure to obtain the temperature distribution and heat transfer. However, no significant results have been obtained successfully, because when higher order finite element methods are used the more computational efforts are necessary due to the distribution of elements. The results of this study are as follows ; 1 . In case of a=b=L, meshes for less than $1\%$ relative errors (temperature distribution) acquired in various methods to exact solution are $2\times2,\;4\times4,\;8\times8\;and\;8\tiems8$ for each FEM 10, FEM 6, FEM 3 and FDM and a=L, b=1/2L are $10\times5$ for each FEM 3 and FDM. And the tendency of results acquired of heat transfer is similar to those above. 2 . In computational efforts (a=b=L), FEM 6 has taken 21 times. and FEM 10 154times FEM 3 and FDM and FEM 3 is the sane as FDM.

  • PDF

Influences of hygrothermal environment and fiber orientation on shear correction factor in orthotropic composite beams

  • Soumia Benguediab;Fatima Zohra Kettaf;Mohammed Sehoul;Fouad Bourada;Abdelouahed Tounsi;Mohamed Benguediab
    • Coupled systems mechanics
    • /
    • 제12권2호
    • /
    • pp.151-165
    • /
    • 2023
  • In this study, a simple method for the determination of the shear correction factor for composites beam with a rectangular cross section is presented. The plane stress elasticity assumption is used after simplifications of the expression of the stress distribution in the beam. The different fiber orientation angle and volume fraction are considered in this work. The studied structure is subjected to various loading type (thermal and hygrothermal). The numerical results obtained show that there is a dependence of the shear coefficient on the orientation of the fibers. The evolution of the shear correction factors depends not only on the orientation of the fibers and also on the volume fraction and the environment. the advantage of this developed formula of the shear correction factor is to obtain more precise results and to consider several parameters influencing this factor which are neglected if the latter is constant.

Experimental and numerical investigations on reinforcement arrangements in RC deep beams

  • Husem, Metin;Yilmaz, Mehmet;Cosgun, Suleyman I.
    • Advances in concrete construction
    • /
    • 제13권3호
    • /
    • pp.243-254
    • /
    • 2022
  • Reinforced concrete (RC) deep beams are critical structural elements used in offshore pile caps, rectangular cross-section water tanks, silo structures, transfer beams in high-rise buildings, and bent caps. As a result of the low shear span ratio to effective depth (a/d) in deep beams, arch action occurs, which leads to shear failure. Several studies have been carried out to improve the shear resistance of RC deep beams and avoid brittle fracture behavior in recent years. This study was performed to investigate the behavior of RC deep beams numerically and experimentally with different reinforcement arrangements. Deep beams with four different reinforcement arrangements were produced and tested under monotonic static loading in the study's scope. The horizontal and vertical shear reinforcement members were changed in the test specimens to obtain the effects of different reinforcement arrangements. However, the rebars used for tension and the vertical shear reinforcement ratio were constant. In addition, the behavior of each deep beam was obtained numerically with commercial finite element analysis (FEA) software ABAQUS, and the findings were compared with the experimental results. The results showed that the reinforcements placed diagonally significantly increased the load-carrying and energy absorption capacities of RC deep beams. Moreover, an apparent plastic plateau was seen in the load-displacement curves of these test specimens in question (DE-2 and DE-3). This finding also indicated that diagonally located reinforcements improve displacement ductility. Also, the numerical results showed that the FEM method could be used to accurately predict RC deep beams'behavior with different reinforcement arrangements.

Parametric study of shear capacity of beams having GFRP reinforcement

  • Vora, Tarak P.;Shah, Bharat J.
    • Advances in concrete construction
    • /
    • 제13권 2호
    • /
    • pp.183-190
    • /
    • 2022
  • A wide range of experimental bases and improved performance with different forms of Fiber Reinforced Polymer (FRP) have attracted researchers to produce eco-friendly and sustainable structures. The reinforced concrete (RC) beam's shear capacity has remained a complex phenomenon because of various parameters affecting. Design recommendations for the shear capacity of RC elements having FRP reinforcement need a more experimental database to improve design recommendations because almost all the recommendations replace different parameters with FRP's. Steel and FRP are fundamentally different materials. One is ductile and isotropic, whereas the other is brittle and orthotropic. This paper presents experimental results of the investigation on the beams with glass fiber reinforced polymer (GFRP) reinforcement as longitudinal bars and stirrups. Total twelve beams with GFRP reinforcement were prepared and tested. The cross-section of the beams was rectangular of size 230 × 300 mm, and the total length was 2000 mm with a span of 1800 mm. The beams are designed for simply-supported conditions with the two-point load as per specified load positions for different beams. Flexural reinforcement provided is for the balanced conditions as the beams were supposed to test for shear. Two main variables, such as shear span and spacing of stirrups, were incorporated. The beams were designed as per American Concrete Institute (ACI) ACI 440.1R-15. Relation of VExp./VPred. is derived with axial stiffness, span to depth ratio, and stirrups spacing, from which it is observed that current design provisions provide overestimation, particularly at lower stirrups spacing.