• 제목/요약/키워드: recovery temperature

검색결과 1,659건 처리시간 0.027초

Irradiation damage and recovery in gold-coated fiber optics

  • Jacy K. Conrad;Michael E. Woods
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.685-687
    • /
    • 2024
  • Fiber optic cables are used extensively for remote monitoring in applications under extreme conditions, such as at high temperatures or in ionizing radiation fields. When high temperature fiber optic cables were subjected to gamma irradiations, there was a significant loss in transmission at wavelengths < 350 nm after only 1 minute of irradiation. Negligible recovery of the fiber optic transmission with time was observed over 2 years, but the irradiation damage was almost completely reversed by high temperature annealing at 400 ℃.

Control of Water Heat Recovery Chiller Using Split Condenser Templifier Application

  • Cho, Haeng-Muk;Mahmud, Iqbal
    • 에너지공학
    • /
    • 제18권1호
    • /
    • pp.17-21
    • /
    • 2009
  • By using the heat recovery of water-cooled chillers, it is possible to reduce the energy operating costs positively and at the same time it could fulfill the heating re-heat air conditioning system as well as the hot water requirements. Basically templifiers are designed to economically to turn the waste heat into useful heat. Waste heat is extracted from a fluid stream by cooling it in the evaporator, the compressor amplifies the temperature of the heat and the condenser delivers the heat to heating loads such as space heating, kitchens and domestic hot water. Design of higher water temperature requirements and split condenser heat recovery chiller system (using of templifiers) produced hotter condenser water approximately up to $60^{\circ}C$ and control the entire heat recovery system.

Effects of Process Variables on The Electrochemical Recovery of Palladium in A HCl Solution

  • Kim, Min-Seuk;Lee, Jae-Chun;Kim, Won-Baek
    • 자원리싸이클링
    • /
    • 제14권1호
    • /
    • pp.55-63
    • /
    • 2005
  • This study investigated the electrochemical recovery of palladium in a HCl solution that is used for palladium leaching. The high acidity of HCl solution and the low concentration of Pd ions increased the cathodic overpotential and reduced the limiting current density. Lowering the current density produced dense deposits; however, they were under high tensile stress. Raising the temperature affected both the densification and the stress, which enabled the attainment of dense Pd deposits under low stress. Lowering the current density and raising the temperature up to 70$^{\circ}C$ was recommended for the recovery of palladium as sound bulk Pd deposits. Current efficiency was over 85% at the initial stage of recovery may decrease the current efficiency, since a low Pd ion concentration results in a low limiting current density.

CNC 공작기계에서 열변형 오차 보정 시스템의 고장진단 및 복구 (Fault Diagnosis and Recovery of a Thermal Error Compensation System in a CNC Machine Tool)

  • 황석현;이진현;양승한
    • 한국정밀공학회지
    • /
    • 제17권4호
    • /
    • pp.135-141
    • /
    • 2000
  • The major role of temperature sensors in thermal error compensation system of machine tools is improving machining accuracy by supplying reliable temperature data on the machine structure. This paper presents a new method for fault diagnosis of temperature sensors and recovery of faulted data to establish the reliability of thermal error compensation system. The detection of fault and its location is based on the correlation coefficients among temperature data from the sensors. The multiple linear regression model which is prepared using complete normal data is also used fur the recovery of faulted data. The effectiveness of this method was tested by comparing the computer simulation results and measured data in a CNC machining center.

  • PDF

전열교환기가 설치된 기류전환형 히트펌프의 동계운전성능에 관한 실험적 연구 (An Experimental Study on the Operating Performance of an Air Shift type Heat Pump with Heat Exchanger)

  • 장영근
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.567-572
    • /
    • 2010
  • Air shift type heat pump is combined heat recovery ventilator and refrigerator, and it is installed an air shifter changing air flow. And so it is an perfect AHU(Air Handling Unit) capable to cooling, heating, ventilation and heat recovery. Therefore, an experimental study has been carried out to investigate the operating performance in winter for this system. An experimental data are room temperature, inlet/outlet temperature of condenser, evaporator and heat exchanger. They have been measured as the variation of outdoor temperature. The results, in case of rising above freezing, the air shift type heat pump system is operated normally, and the heating COP is 3.0~4.2 by varying outdoor temperature from $-3^{\circ}C$ to $15^{\circ}C$.

NR, SBR, BR 가황물의 원형 변형으로부터의 회복 거동 (Recovery Behaviors of NR, SBR and BR Vulcanizates from Circular Deformation)

  • 장중희;최성신
    • Elastomers and Composites
    • /
    • 제44권4호
    • /
    • pp.442-446
    • /
    • 2009
  • 충전제의 영향을 막기 위해 비보강 NR, BR, SBR 고무 가황물을 원형 변형시켜 노화시킨 후 회복 거동을 비교하였다. 시료는 상온, 50, 70, $90^{\circ}C$에서 10일간 노화시켰다. 측정 시간이 증가함에 따라 회복률은 증가하였다. 노화 후 측정 시간에 따른 회복률의 변화로부터 1.0 초 미만의 순간회복률을 구하였다. 상온 노화에서는 노화 기간이 짧아 고무 간의 회복률 차이가 거의 나타나지 않았다. 하지만 50, 70, $90^{\circ}C$에서의 가속 노화 실험 결과에서는 각 고무 간의 회복률 차이가 뚜렷하게 나타났다. BR의 회복률이 가장 우수하였고, SBR의 회복률이 가장 적었다. 그러나 $90^{\circ}C$ 가속 노화 에서는 NR의 회복률이 BR보다 높게 나타났다. 노화 온도가 높아 질수록 초기 회복률이 감소하였으며, 그 감소 폭은 SBR이 가장 크게 나타났다. 실험 결과는 고무의 반발 특성과 노화에 의한 가교밀도 변화로 설명하였다.

Superconductivity recovery of vacuum annealed HTS GdBCO CC

  • You, Jong Su;Yang, Jeong Hun;Song, Kyu Jeong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.41-46
    • /
    • 2022
  • The superconducting properties of high temperature superconducting (HTS) GdBCO coated conductor (CC) tape (Ag/GdBCO/Buffer-layers/Stainless Steel) were investigated, specifically a series of samples prepared by vacuum heat treatment (200℃ to 600℃), using a Quantum Design PPMS-14. The critical current density Jc value was obtained by applying the modified Bean model to the irreversible magnetization ∆Mirr(H) data which was estimated from the magnetization M(H) loop. The reduction rates of lnJc and Tc values according to the increase of the vacuum annealing temperature Tan were d(lnJc)/dTan = - 0.016 A/(cm2∙℃) and dTc/dTan = - 0.24, respectively. We examined the effect of recovery temperature Tre (475℃ to 700℃) and recovery duration time t (0.5 h to 24 h) on the restoration of previously completely lost superconductivity in samples that subsequently received heat treatment in an O2 gas flow space. All samples were fully restored to superconductivity by heat treatment in an O2 gas flow space. The recovery temperatures Tre (475℃ to 700℃) and recovery duration times t (0.5 h to 24 h) were both independent of the superconductivity recovery characteristics.

Study on Performance Evaluation of Oscillating Heat Pipe Heat Exchanger for Low Temperature Waste Heat Recovery

  • Bui, Ngoc-Hung;Kim, Ju-Won;Jang, In-Seung;Kang, Jeong-Kil;Kim, Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권2호
    • /
    • pp.73-81
    • /
    • 2003
  • The performance of heat exchanger using oscillating heat pipe (OHP) for low temperature waste heat recovery was evaluated. OHP used in this study was made from low finned copper tubes connected by many turns to become the closed loop of serpentine structure. The OHP heat exchanger was formed into shell and tube type. R-22 and R-141b were used as the working fluids of OHP with a fill ratio of 40 vol.%. Water was used as the working fluid of shell side. As the experimental parameters, the inlet temperature difference between heating and cooling water and the mass velocity of water were changed. The mass velocity of water was changed from 30 kg/$m^2$s to 92 kg/$m^2$s. The experimental results showed that the heat recovery rate linearly increased as the mass velocity and the inlet temperature difference of water increased. Finally, the performance of OHP heat exchanger was evaluated by $\varepsilon$-NTU method. It was found that the effectiveness would be 80% if NTU were about 1.5.

Influence of Working Fluids to Heat Transfer Characteristics of Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery

  • Lee, Wook-Hyun;Im, Yong-Bin;Kim, Ju-Won;Kim, Jeung-Hoon;Kim, Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.27-35
    • /
    • 2001
  • Heat transfer characteristics of a heat exchanged for low temperature waste heat recovery using oscillating capillary tube heat pipe (OCHP) were evaluated against the charging ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working a 2.6mm in outside diameter, 1.44mm in inside diameter with 101m length and 140 turns. Charging ratio of working fluid was 40% and 50%. water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and 9~27 $4kg/m^2s$, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-142b and R-290 and it was proportional to Figure of Merit for thermosyphon. As a result, it was thought that R-22 was the most reasonable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF

저온 폐열회수용 진동세관형 히트파이프 열교환기의 작동 유체에 따른 열전달 특성 (Influence of Working Fluids to Heat Transfer Characteristics of the Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery)

  • 이욱현;임용빈;김정훈;김종수
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.659-666
    • /
    • 2000
  • Heat transfer characteristics of a heat exchanger for low temperature waste heat recovery using oscillating capillary tube heat pipe were evaluated against the charge ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working fluids. The heat exchanger was composed of heat pipe with capillary tube bundles, having a 2.6mm in outer diameter, 1.4mm in inner diameter with 101m long, and 40 turns. Charge ratio of working fluid was 40% and 50%. Water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and9~27 kg /$m^2s$,, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-l42b and R-290 and it was proportional to Figure of merit for thermosyphons. As a result, it was thought that R-22 was the most suitable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF