• 제목/요약/키워드: recovery of set

검색결과 379건 처리시간 0.023초

터보과급 디젤기관의 과도운전시 응답성능에 관한 연구 (A Study on the Response Performances under Transient Operating Conditions in a Turlblocharged Diesel Engine)

  • 최낙정;이창식
    • 대한기계학회논문집
    • /
    • 제16권8호
    • /
    • pp.1575-1582
    • /
    • 1992
  • 본 연구에서는 정상운전 중인 4사이클 6실린더 터보과급 디젤기관에 갑자기 큰 부하가 작용하였을 경우, 기관 및 과급기 관성 모멘트의 변화가 기관과 과급기의 실제 회전속도, 압축기 압력비, 실린더내 공기유량, 연소효율, 배기온도 등의 과도 응 답성능에 미치는 영향을 시뮬레이션해석과 실험을 통하여 규명하였다.

Quantification of Bacterial Attachment-related Parameters in Porous Media

  • Park, Seong-Jik;Lee, Chang-Gu;Kim, Song-Bae
    • Environmental Engineering Research
    • /
    • 제13권3호
    • /
    • pp.141-146
    • /
    • 2008
  • Transport of Escherichia coli ATCC 11105 through porous media was investigated in this study using two sets of column experiments to quantify the attachment-related parameters (sticking efficiency, attachment rate coefficient and filter factor). The first set of experiments was performed in quartz sand under different ionic strength conditions (1, 20, 100, 200 mM) while the second experiments were carried out in quartz sand mixed with metal oxyhydroxide-coated sand (0, 5, 10, 25%). The breakthrough curves of bacteria were obtained by monitoring effluent, and then bacterial mass recovery and attachment-related parameters were quantified from these curves. The first experiments showed that the mass recoveries were in the range of 13.3 to 64.7%, decreasing with increasing ionic strength. In the second experiments, the mass recoveries were in the range of 15.0 to 43.4%, decreasing with increasing coated sand content. The analysis indicated that the sticking efficiency, attachment rate coefficient and filter factor increased with increasing ionic strength and coated sand content. The value of filter factor in the first experiments ranged from 1.45 e-2 to 6.72 e-2 1/cm while in the second experiments it ranged from 2.78 e-2 to 6.32 e-2 1/cm. Our filter factor values are one order of magnitude lower than those from other studies. This discrepancy can be attributed to the size of sand used in the experiment. The analysis demonstrated that the travel distance of bacteria estimated using the filter factor can be varied greatly depending on the solution chemistry and charge heterogeneity of porous media.

새로운 DFT 비교기를 이용한 자동 다전원 동기절체 스위치에 관한 연구 (A Study on Automatic Multi-Power Synchronous Transfer Switch using New DFT Comparator)

  • 곽아림;박성미;손경종;박성준;김종철
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.423-431
    • /
    • 2022
  • The UPS(Uninterruptible Power Supply) system operates in the battery charging mode when the grid is normal, and in the UPS mode, which is the battery discharge mode when a grid error occurs. Since the UPS must supply the same voltage as the grid to the load within 4 [ms] in case of a grid error, the switching time and power recovery time should be short when controlling the output voltage and current of the UPS, and the power failure detection time is also important. The power outage detection algorithm using DFT(Discrete Fourier Transform) proposed in this paper compares the grid voltage waveform with the voltage waveform including the 9th harmonic generated through DFT using Schmitt trigger to detect power outage faster than the existing power outage monitoring algorithm. There are advantages. Therefore, it is possible to supply instant and stable power when switching modes in the UPS system. The multi-power-applied UPS system proposed in this paper uses DFT, which is faster than the conventional blackout monitoring algorithm in detecting power failure, to provide stable power to the load in a shorter time than the existing power outage monitoring algorithm when a system error occurs. The detection method was applied. The changeover time of mode switching was set to less than 4 [ms], which is 1/4 of the system cycle, in accordance with KSC 4310 regulation, which was established by the Industrial Standards Council on the regulation of uninterruptible power supply. A 10 [kW] UPS system in which commercial voltage, vehicle generator, and auxiliary diesel generator can be connected to each of the proposed transfer devices was constructed and the feasibility was verified by conducting an experiment.

Induction of antiviral mechanisms by interferon-related genes in rock bream (Oplegnathus fasciatus) infected with rock bream iridovirus (RBIV)

  • Myung-Hwa Jung
    • 한국어병학회지
    • /
    • 제36권2호
    • /
    • pp.213-228
    • /
    • 2023
  • We evaluated the transcriptional response of interferon (IFN)-related genes in rock bream iridovirus (RBIV)-infected rock bream under high-, low-, or no-mortality conditions induced by different stocking water temperatures. Under the high susceptibility condition (group A, water temperature 26℃, 100% mortality), only the Mx gene was expressed early, with prolonged expression, and with heavy viral loads of approximately 106~107 major capsid protein gene copies/μL from 4 to 10 days post infection (dpi). However, IRF1, IRF3, IRF8, STAT1, ISG15, PKR, Viperin, GVIN1, IFI44, and ISG56 were activated at later time points (8 dpi) and then quickly decreased (10 dpi). For the low susceptibility condition, the water temperature was set at 23℃ for 7 days (group B) and then reduced to 17℃. Group B exhibited a 28% mortality rate, in which persistent and effective antiviral responses were observed for long periods of time. In particular, at 20 and 22 dpi, when virus replication was peaked at approximately 107/μL, the expressions of most of the IFN-related genes (IRF1, IRF3, IRF8, Mx, STAT1, ISG15, PKR, Viperin, GVIN1, IFI44, and ISG56) were significantly higher in group B than in the control group. Moreover, prolonged and higher levels of IRF3 (at least 30 dpi), IRF8 (at least 30 dpi), ISG15 (at least 30 dpi), PKR (at least 28 dpi), Viperin (at least 30 dpi), and IFI44 (at least 30 dpi) were also observed in the recovery stage of infection. Under the no-susceptibility condition at 17℃ (0% mortality), significantly elevated levels of IRF3, Mx, ISG15, and PKR were observed mostly until 20 dpi. The findings indicate that RBIV infection can induce an efficient IFN-mediated antiviral immune response in low- and no-susceptibility conditions. The findings could be valuable for effective control of viral pathogens in fish.

혈액투석환자의 피로와 자기효능감, 가족지지 및 수면요인과의 관계 (The Relationship of Fatigue, Self Efficacy, Family Support and Sleep Factor in Hemodialysis Patients)

  • 최은영;이향련
    • 성인간호학회지
    • /
    • 제17권3호
    • /
    • pp.435-443
    • /
    • 2005
  • Purpose: This study investigated the degree of fatigue of hemodialysis patients, and finds the relationship between fatigue and self-efficacy, family support, and sleep factor. Also, this study was purposed to provide fundamental data to help set up a nursing plan and intervention for recovery and mitigation of hemodialysis patient's fatigue. Method: The subjects in this study were patients treated as hemodialysis patients in Kwangjoo City. Data, subjects are 143 patients. Fatigue was measured using Lee's scale(1991), Self-efficacy using Kim's scale(1995), and Family support using Kim's scale(1993). For the analysis of collected data, Cronbach alpha, descriptive statistics, t-test, ANOVA, Pearson's correlation coefficient, Stepwise multiple regression were used for statistical analysis by SPSSwin(version 11.0) program. Result: Fatigue degree of hemodialysis patients averaged 4.22. Among 143 hemodialysis patients, 70.63% patients answered that they had felt fatigue as noted in this study. The weariest time was after hemodialysis for 21.0% patients. There was significant difference according to the diagnosis period. The patients who were diagnosed over one year had felt more fatigue than ones who were diagnosed within one year. Fatigue was significantly associated with self-efficacy, family support, and sleep factor. Self-efficacy could explain 14.6% of fatigue. Conclusion: The fatigue degree relates with all, self-efficacy, family support, and sleep factor. Especially, it is affected by self-efficacy among them. Thus, the program should be developed to mitigate fatigue as the self-efficacy of hemodialysis is enhanced.

  • PDF

HPLC-PDA를 이용한 오약순기산 중 6종 성분의 동시분석 (Simultaneous Analysis of Six Constituents in Oyaksungi-san using HPLC-PDA)

  • 서창섭;김정훈;신현규
    • 대한한의학방제학회지
    • /
    • 제20권2호
    • /
    • pp.37-46
    • /
    • 2012
  • Objectives : Oyaksungi-san(Wuyaoshunqisan) has been used for treatment of stroke and rheumatoid arthritis in Korea. In this study, a simple and accurate high-performance liquid chromatography(HPLC) method was established for simultaneous determination of six main components, liquiritin, ferulic acid, naringin, hesperidin, neohesperidin, and glycyrrhizin in Oyaksungi-san, a traditional Korean herbal prescription. Methods : The analytical column for separation of six constituents was used a Gemini $C_{18}$ column maintained at $40^{\circ}C$. The mobile phase consisted of two solvent systems, 1.0% (v/v) acetic acid in $H_2O$ (A) and 1.0% (v/v) acetic acid in acetonitrile (B) by gradient flow. The flow rate was 1.0 mL/min and the detector was a photodiode array (PDA) set at 254 nm for glycyrrhizin, 280 nm for liquiritin, naringin, hesperidin, and neohesperidin, and 320 nm for ferulic acid. Results : Calibration curves were acquired with $r^2$ values ${\geq}0.9998$. The results of recovery test were 91.58%-105.90% with a relative standard deviations (RSDs, %) value less than 2.0%. The values of RSD for intra- and inter-day precision were 0.03%-1.72% and 0.03%-1.63%, respectively. The contents of the six compounds in Oyaksungi-san were 0.33-9.30 mg/g. Conclusions : The newly established HPLC method will be helpful to improve quality control of Oyaksungi-san.

확장된 Relief-F 알고리즘을 이용한 소규모 크기 문서의 자동분류 (Document Classification of Small Size Documents Using Extended Relief-F Algorithm)

  • 박흠
    • 정보처리학회논문지B
    • /
    • 제16B권3호
    • /
    • pp.233-238
    • /
    • 2009
  • 자질 수가 적은 소규모 크기 문서들의 자동분류는 좋은 성능을 얻기 어렵다. 그 이유는 문서집단 전체의 자질 수는 크지만 단위 문서 내 자질 수가 상대적으로 너무 적기 때문에 문서간 유사도가 너무 낮아 우수한 분류 알고리즘을 적용해도 좋은 성능을 얻지 못한다. 특히 웹 디렉토리 문서들의 자동분류에서나, 디스크 복구 작업에서 유사도 평가와 자동분류로 연결되지 않은 섹터를 연결하는 작업에서와 같은 소규모 크기 문서의 자동분류에서는 좋은 성능을 얻지 못한다. 따라서 본 논문에서는 소규모 크기 문서의 자동분류에서의 문제점을 해결하기 위해 분류 사전작업으로, 예제기반 자질 필터링 방법 Relief-F알고리즘을 소규모 문서 내 자질 필터링에 적합한 ERelief-F 알고리즘을 제시한다. 또 비교 실험을 위해, 기존의 자질 필터링 방법 중 Odds Ratio와 정보이득, 또 Relief-F 알고리즘을 함께 실험하여 분류결과를 비교하였다. 그 결과, ERelief-F 알고리즘을 사용했을 때의 결과가 정보이득과 Odds Ratio, Relief-F보다 월등히 우수한 성능을 보였고 부적절한 자질도 많이 줄일 수 있었다.

A Study on the Recovery of Li2CO3 from Cathode Active Material NCM(LiNiCoMnO2) of Spent Lithium Ion Batteries

  • Wang, Jei-Pil;Pyo, Jae-Jung;Ahn, Se-Ho;Choi, Dong-Hyeon;Lee, Byeong-Woo;Lee, Dong-Won
    • 한국분말재료학회지
    • /
    • 제25권4호
    • /
    • pp.296-301
    • /
    • 2018
  • In this study, an experiment is performed to recover the Li in $Li_2CO_3$ phase from the cathode active material NMC ($LiNiCoMnO_2$) in waste lithium ion batteries. Firstly, carbonation is performed to convert the LiNiO, LiCoO, and $Li_2MnO_3$ phases within the powder to $Li_2CO_3$ and NiO, CoO, and MnO. The carbonation for phase separation proceeds at a temperature range of $600^{\circ}C{\sim}800^{\circ}C$ in a $CO_2$ gas (300 cc/min) atmosphere. At $600{\sim}700^{\circ}C$, $Li_2CO_3$ and NiO, CoO, and MnO are not completely separated, while Li and other metallic compounds remain. At $800^{\circ}C$, we can confirm that LiNiO, LiCoO, and $Li_2MnO_3$ phases are separated into $Li_2CO_3$ and NiO, CoO, and MnO phases. After completing the phase separation, by using the solubility difference of $Li_2CO_3$ and NiO, CoO, and MnO, we set the ratio of solution (distilled water) to powder after carbonation as 30:1. Subsequently, water leaching is carried out. Then, the $Li_2CO_3$ within the solution melts and concentrates, while NiO, MnO, and CoO phases remain after filtering. Thus, $Li_2CO_3$ can be recovered.

Evaluation of Matrix Effects in Quantifying Microbial Secondary Metabolites in Indoor Dust Using Ultraperformance Liquid Chromatographe-Tandem Mass Spectrometer

  • Jaderson, Mukhtar;Park, Ju-Hyeong
    • Safety and Health at Work
    • /
    • 제10권2호
    • /
    • pp.196-204
    • /
    • 2019
  • Background: Liquid chromatography-tandem mass spectrometry (LC-MSMS) for simultaneous analysis of multiple microbial secondary metabolites (MSMs) is potentially subject to interference by matrix components. Methods: We examined potential matrix effects (MEs) in analyses of 31 MSMs using ultraperformance LC-MSMS. Twenty-one dust aliquots from three buildings (seven aliquots/building) were spiked with seven concentrations of each of the MSMs ($6.2pg/{\mu}l-900pg/{\mu}l$) and then extracted. Another set of 21 aliquots were first extracted and then, the extract was spiked with the same concentrations. We added deepoxy-deoxynivalenol (DOM) to all aliquots as a universal internal standard. Ten microliters of the extract was injected into the ultraperformance LC-MSMS. ME was calculated by subtracting the percentage of the response of analyte in spiked extract to that in neat standard from 100. Spiked extract results were used to create a matrix-matched calibration (MMC) curve for estimating MSM concentration in dust spiked before extraction. Results: Analysis of variance was used to examine effects of compound (MSM), building and concentration on response. MEs (range: 63.4%-99.97%) significantly differed by MSM (p < 0.01) and building (p < 0.05). Mean percent recoveries adjusted with DOM and the MMC method were 246.3% (SD = 226.0) and 86.3% (SD = 70.7), respectively. Conclusion: We found that dust MEs resulted in substantial underestimation in quantifying MSMs and that DOM was not an optimal universal internal standard for the adjustment but that the MMC method resulted in more accurate and precise recovery compared with DOM. More research on adjustment methods for dust MEs in the simultaneous analyses of multiple MSMs using LC-MSMS is warranted.

Study on the Separation of MAs from HLLW and Their Extraction Behavior Using New Extractants of Amido Podand

  • An, Ye-Guo;Luo, Fang-Xiang;Zhu, Zhi-Xuan;Zhang, Xiang-Ye;Zhu, Wen-Bin
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 Proceedings of the 4th Korea-China Joint Workshop on Nuclear Waste Management
    • /
    • pp.245-256
    • /
    • 2004
  • The extraction of three kinds of amido podands, N,N,N'N'-tetrabutyl-3-oxa-pentanedi- amide (TBDGA), N,N,N'N'-tetra-isobutyl-3-oxa-pentanediamide(TiBDGA) and N,N,N'N'-tetra- butyl-3,6-dioxa-oct-anediam- ide(TBDOODA) on U(VI),Pu(IV), Am(III), Eu(III) and other metal ions is studied in nitric acid solutions. 40%octanol-kerosene is chosen as diluents to eliminate third phase and emulsion. TBDGA and TiBDGA show extraction selectivity to An(III) and Ln(III) much higher than to U(VI) and Pu(IV). Fe, Ru and Mo is poorly extracted by the three kinds of amid podands in 2~3mol/L $HNO_3$ solutions. Aiming to eliminate interface crude when using simulated HLLW solution in the system of 0.2mol/L TBDGA/Octanol+kerosene, acetohydroxyamic acid was adapted. Distribution ratio of zirconium was decreased when adding acetohydroxyamic acid in aqueous solution, and interface crude disappeared as mixing extractant with HLLW. The counter-current extraction test is carried out in a set of miniature mixer-settler, with 0.2mol/L TBDGA/ 40% octanol-kerosene as extractant to separate U(VI), Pu(IV), Am(III) and Eu(III) from simulated high level liquid waste(HLLW) solution. In battery A, lanthanides and actinides are coextracted into organic phase with the recovery of 99.98% for U(Ⅵ), >99.99% for Pu(IV), and >99.99% for Am(III) and Eu(III) respectively. In battery R1, 99.99% U, 86.2% Pu and a part of Am or Eu are stripped into aqueous phase by 0.2mol/L acetohydroxyamic acid (AHA) in 0.01mol/L $HNO_3$ solution. In battery $R_2$, Am, Eu and remained Pu are completely back-extracted by 0.2mol/L AHA. This separation process contains no salt reagent, and it is not necessary to dilute HLLW feed.

  • PDF