• Title/Summary/Keyword: recovery cost

Search Result 608, Processing Time 0.031 seconds

HEAT PIPE TYPE EXHAUST HEAT RECOVERY SYSTEM FOR HOT AIR HEATER

  • Kang, G.C.;Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.654-661
    • /
    • 2000
  • Area of greenhouse increases rapidly up to 45,265ha by the year of 1998 in Korea. Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season. However, exhaust gas heat discharged to atmosphere through chimney reaches up to 10~20% of total heat of the oil combusted in the furnace. In order to recapture the heat of this exhaust gas and to recycle for greenhouse heating, the heat pipe type exhaust heat recovery system was manufactured and tested in this experiment. The exhaust heat recovery system was made for space heating in the greenhouse. The system consisted of a heat exchanger made of heat pipes, ${\emptyset}15.88{\times}600mm$ located in the rectangular box of $600{\times}550{\times}330mm$, a blower and air ducts. The rectangular box was divided by two compartments where hot chamber exposed to exhaust gas in which heat pipes could pick up the heat of exhaust gas, and by evaporation of the heat transfer medium in the pipes it carries the heat to the cold compartment, then the blower moves the heat to greenhouse. The number of heat pipe was 60, calculated considering the heat exchange amount between flue gas and heat transfer capacity of heat pipe. The working fluid of heat pipe was acetone because acetone is known for its excellent heat transfer capacity. The system was attached to the exhaust gas path. According to the performance test it could recover 53,809 to 74,613kJ/hr depending on the inlet air temperature of 12 to $-12^{circ}C$ respectively when air flow rate $1,100\textrm{m}^3/hr$. The exhaust gas temperature left the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the air and the flue gas, the temperature difference was collected by the air and the warm air temperature was about $60^{circ}C$ at the air flow rate of $1,100\textrm{m}^3/hr$. This heat pipe type exhaust heat recovery system can reduce fuel cost by 10% annually according to the economic analysis.

  • PDF

Outcome of Febrile Neutropenic Patients on Granulocyte Colony Stimulating Factor in a Tertiary Care Hospital

  • Osmani, Asif Husain;Ansari, Tayyaba Zehra;Masood, Nehal;Ahmed, Bilal
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2523-2526
    • /
    • 2012
  • Introduction: Febrile neutropenia is a relatively frequent event in cancer patients treated with chemotherapy and improvement in absolute neutrophil count (ANC) has been linked directly to improved outcome. Evaluation of granulocyte colony stimulating factors (GCSFs) for treatment has shown reduced incidences of episodes of prolonged neutropenia and protracted hospitalization. To determine absolute neutrophil counts with GCSF in febrile neutropenic cancer patients admitted to a tertiary care centre and to co-relate the improvement in ANC with mortality and hospital discharge. Methods: A prospective cross sectional study was carried at an oncology ward at Aga Khan University hospital from January 2010 to June 2011. All adult patients who were admitted and treated with GCSF for chemotherapy induced febrile neutropenia were included. Multivariable regression was conducted to identify the factors related with poor outcomes. Results: A total of 131 patients with febrile neutropenia were identified with mean age of 43.2 (18-85) years, 79 (60%) being ${\leq}50$. Seventy-five (57%) had solid tumors and 56 (43%) hematological malignancies, including lymphoma. Fifty seven (43.5%) had an ANC less 100 cells/$mm^3$, 34 (26%) one between 100-300 cells/$mm^3$ and 40 (31%) an ANC greater than 300 cells/$mm^3$. Thirty (23%) patients showed ANC recovery in 1-3 days, and 74(56%) within 4-7 days. Thirteen (10%) patients showed no recovery. The overall mortality was 18 (13.7%) patients. The mean time for ANC recovery seen in hematological malignancies was 6.34 days whereas for solid tumors it was 4.88 days. Patients with ANC <100 cells/$mm^3$ were more likely to die than patients with ANC >300 cells/$mm^3$ by a factor of 4.3. Similarly patients >50 years of age were 2.7 times more likely to die than younger patients. Conclusion: Our study demonstrated that use of GCSF, in addition to intravenous antibiotics, in treatment of patients with chemotherapy induced febrile neutropenia accelerates neutrophil recovery, and shortens antibiotic therapy and hospitalization. We propose to risk classify the patients at the time of admission to evaluate the cost effectiveness of this approach in a resource constrained setup.

Heat Integration and Economic Analysis of Dry Flue Gas Recirculation in a 500 MWe Oxy-coal Circulating Fluidized-bed (CFB) Power Plant with Ultra-supercritical Steam Cycle (순환 유동층 보일러와 초초임계 증기 사이클을 이용한 500 MWe급 순산소 화력발전소의 건식 재순환 흐름의 열 교환 및 경제성 분석)

  • Kim, Semie;Lim, Young-Il
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.60-67
    • /
    • 2021
  • This study presented techno-economic analysis of a 500 MWe oxy-coal power plant with CO2 capture. The power plant included a circulating fluidized-bed (CFB), ultra-supercritical steam turbine, flue gas conditioning (FGC), air separation unit (ASU), and CO2 processing unit (CPU). The dry flue gas recirculation (FGR) was used to control the combustion temperature of CFB. One FGR heat exchanger, one heat exchanger for N2 stream exiting ASU, and a heat recovery from CPU compressor were considered to enhance heat efficiency. The decrease in the temperature difference (ΔT) of the FGR heat exchanger that means the increase in heat recovery from flue gas enhanced the electricity and exergy efficiencies. The annual cost including the FGR heat exchanger and FGC cooling water was minimized at ΔT = 10 ℃, where the electricity efficiency, total capital cost, total production cost, and return on investment were 39%, 1371 M$, 90 M$, and 7%/y, respectively.

Shared Protection of Lightpath with Guaranteed Switching Time over DWDM Networks

  • Chen Yen-Wen;Peng I-Hsuan
    • Journal of Communications and Networks
    • /
    • v.8 no.2
    • /
    • pp.228-233
    • /
    • 2006
  • Survivability is a very important requirement for the deployment of broadband networks because out of service links can affect volumes of traffic even if it is a very short time. And the data paths of broadband networks, which are critical for traffic engineering, are always necessary to be well protected. The procedure of protection or restoration for a path is initiated when failure is detected within the working path. In order to minimize the influence on transmission quality caused by the failure of links and to provide a definite time for the recovery from the failure, the protection switching time (PST) should be carefully considered in the path arrangement. Several researches have been devoted to construct the protection and restoration schemes of data paths over dense wavelength division multiplexing (DWDM) networks, however, there was rare research on the design of data paths with guaranteed protection switching time. In this paper, the PST-guaranteed scheme, which is based on the concept of short leap shared protection (SLSP), for the arrangement of data paths in DWDM networks is proposed. The proposed scheme provides an efficient procedure to determine a just-enough PST-guaranteed backup paths for a working path. In addition to selecting the PST-guaranteed path, the network cost is also considered in a heuristic manner. The experimental results demonstrate that the paths arranged by the proposed scheme can fully meet the desired PST and the required cost of the selected path is competitive with which of the shared path scheme.

A Remote Rehabilitation System using Kinect Stereo Camera (키넥트 스테레오 영상을 이용한 원격 재활 시스템)

  • Kim, Kyungah;Chung, Wan-Young;Kim, Jong-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.196-201
    • /
    • 2016
  • Rehabilitation exercises are the treatments designed to help patients who are in the process of recovery from injury or illness to restore their body functions back to the original status. However, many patients suffering from chronic diseases have found difficulties visiting hospitals for the rehabilitation program due to lack of transportation, cost of the program, their own busy schedules, etc. Also, the program usually contains a few medical check-ups which can cause patients to feel uncomfortable. In this paper, we develop a remote rehabilitation system with bio-signals by a stereo camera. A Kinect stereo camera manufactured by Microsoft corporation was used to recognize the body movement of a patient by using its infrared(IR) camera. Also, we detect the chest area of a user from the skeleton data and process to gain respiratory status. ROI coordinates are created on a user's face to detect photoplethysmography(PPG) signals to calculate heart rate values from its color sensor. Finally, rehabilitation exercises and bio-signal detecting features are combined into a Windows application for the cost effective and high performance remote rehabilitation system.

A Study on the Introduction of Home-Based Physical Therapy for Patients with Cerebrovascular Disease

  • Kim, Gyu-Yong;Ahn, Chang-Sik;Jeon, Hye-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.2
    • /
    • pp.118-123
    • /
    • 2015
  • Purpose: This study was conducted in order to present basic policy data for introduction of a home-based physical therapy (HBPT) policy. Methods: The study surveyed physical therapists and patients for six weeks, in order to identify satisfaction with physical therapy. The statistical significance of the management plan with regard to costs and cost estimation and payment methods was determined and managed according to the operating principals of HBPT, eligibility criteria, number of visits, treatment time, and team approach. Results: Through the survey all groups of patients and physical therapists recognized the need for HBPT. They felt that the most desirable methods for activation of physical therapy visits involve precise diagnosis and evaluation through a team approach. While making regular visits to the patient three times a week, an expert visiting physical therapist with 3 to 5 years of experience in the clinical field could provide central nerve developmental treatment in less than 60 minutes; this service could be provided at a reasonable cost, minimizing unnecessary hospital visits, reducing time, medical expenses and facilitating a quick recovery due to psychological satisfaction resulting from a decrease in the psychological anxiety patients often experience in medical institutions. Conclusion: Based on the study results provided above, if HBPT is to be introduced, appropriate pricing and programs should be based on the results of pilot projects.

A Study of Trials on Material Integration Pool System for Logistics Rationalization - Basing on the Improvement a precedent about Logistics System of 'A' Enterprise - (물류혁신을 위한 자재통합공동물류 시행에 관한 연구(A사 물류시스템 개선사례를 중심으로))

  • Won, You-Jon;Kang, Kyung-Sik
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.11a
    • /
    • pp.373-383
    • /
    • 2006
  • Logistics is one of the most important factors to manage a stream of materials in economic environment. Establishing effective logistics system needs to consider some constraints which are fluctuation of materials volume, a long distance between makers and consumers, one way logistics and small quantity batch production. It is estimated that Unit Load System should be a powerful method to cope with those problems. It helps to realize the key issues which are Standardization and Logistics Pool System The Material Unification of Logistics System is able to participate in all kinds of industries including manufacturing, distribution and logistics. This system has some merits which are a long distance transportation cost down, product recovery, and treatment in the unbalance of demand and supply caused by unstable materials volume. Four strategies of Material Logistics Model are Packing Rationalization, Logistics Pool System, JIT System application and establishing effective infrastructure. The Material Unification Of Logistics System based on Unit Load System achieves efficiency of logistics and largely decreases moving cost.

  • PDF

Design of Effective Subscriber Network Based on Interation network (음성 데이타 통합을 위한 가입자 망설계와 전송 성능 평가)

  • Chung, Jun-Ho;Eom, Ki-Bok;Yoe, Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.142-145
    • /
    • 2001
  • I did research or design technology of(integration) network of PSTN and PSDN in this paper. Network structure model in association with soft switching and access gateway can create various services based on web and live time and service fee at the rate of bandwidth which can't be provided by existing network based on SONET. Also, interns of capability(function) of each area and construction of local network subscribers, it has great recovery capability by separating each network as local areas. It indicates that it can additionally maximize the application of its own communication network and drastic reduction of communication cost because it is alternated to exclusive usage cost.

  • PDF

A simple energy recovery circuit with current-fed type for plasma display panel (PDP) (간단한 전류원 형태의 구조를 갖는 새로운 PDP 에너지 회수 회로)

  • Yi, Kang-Hyun;Han, Sang-Kyoo;Choi, Seong-Wook;Kim, Chong-Eun;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.376-379
    • /
    • 2005
  • High efficiency and low cost sustain driver for plasma display panel (PDP) with current fed is proposed. Main concept of the proposed circuit is using the current source to charge and discharge panel. As a result, all power switches can achieve the zero voltage switching (ZVS) and every auxiliary switch can also do the zero current switching (ZCS). Moreover, since the inductor current can compensate the discharge current, the current stress of all power switches can be reduced considerably. Furthermore, it has features as a simpler structure, less mass, less cost, and lower electromagnetic interference than prior circuit.

  • PDF

MPLS Alternate Path Rerouting and Restoration (MPLS 대체 경로 재설정과 복구)

  • Lee Kil-Hung
    • The KIPS Transactions:PartC
    • /
    • v.12C no.3 s.99
    • /
    • pp.401-408
    • /
    • 2005
  • We propose a new MPLS restoration scheme that uses network resources more efficiently and minimizes the backup path cost effectively. Contrary to other restoration strategies, the proposed restoration scheme starts the recovery action at the selected node of a working LSP. At LSP setup, the working and backup path cost is evaluated and the starting node of restoration is designated. By doing so, the restoration speed could be further increased and resource utilization could be maximized. We simulated the proposed scheme and compared with other restoration and protection schemes. The result shows that our scheme can provide fast restoration with acceptable delay and loss characteristics.