• Title/Summary/Keyword: reconstructed

Search Result 3,450, Processing Time 0.035 seconds

Arthroscopic ACL Reconstruction Using Fresh-Frozen Achilles Allograft -Clinical results, Recovery of sports activity- (아킬레스 동종건을 이용한 전방십자인대 재건술후 임상적 결과와 운동력 회복 평가)

  • Chun Churl Hong;Ha Dae Ho;Kim Dong Chul;Kim Hyun Jun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.31-36
    • /
    • 2002
  • Purpose : ACL (anterior cruciate ligament) reconstruction using achilles allograft was done for whom ACL injured person in recreational sports activity. The purpose of this study was to evaluate the clinical results and return to their sports activity in these patients. Materials and Methods : ACL injured 56 amateur athletes who had experienced sports 3 times a week more than 5 years, reconstructed with Achilles allograft, and it was analyzed subjective and objective parameter, Tegner scoring, Telos stress arthrometer, Lysholm Knee Scoring System and modified Feagin scoring system. The average age was 25 years old (range: 18$\~$49), the average follow up period was 15 months (range: 12$\~$19). Morbid sports were football (29 cases), basket ball (14 cases), badminton (5 cases), tennis (3 cases), squash (2 cases) and otherwise (3 cases). Result : The mean Lysholm Knee Scoring System was improved to 88.2 from 60. Telos arthrometer in anterior stress test revealed 2.3 mm improved from 7.1 mm. The modified Feagin scoring system showed 50 cases (89$\%$) with excellent and good results. We had obtained 12 cases (21$\%$) of Tegner score VI, 32 cases (57$\%$) of score V, 20 cases (35%$\%$ of score IV, 3 (5.3$\%$) cases of score III. Conclusions : Reconstruction of anterior cruciate ligaments can restore stability sufficient to allow sports activity in ACL injured patients, but it’s difficult to achieve 'normal' sports activity. So we will have to solve the reasons of this dissatisfaction at furthermore.

  • PDF

A Study on Mechanical Errors in Cone Beam Computed Tomography(CBCT) System (콘빔 전산화단층촬영(CBCT) 시스템에서 기계적 오류에 관한 연구)

  • Lee, Yi-Seong;Yoo, Eun-Jeong;Kim, Seung-Keun;Choi, Kyoung-Sik;Lee, Jeong-Woo;Suh, Tae-Suk;Kim, Joeng-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • This study investigated the rate of setup variance by the rotating unbalance of gantry in image-guided radiation therapy. The equipments used linear accelerator(Elekta Synergy TM, UK) and a three-dimensional volume imaging mode(3D Volume View) in cone beam computed tomography(CBCT) system. 2D images obtained by rotating $360^{\circ}$and $180^{\circ}$ were reconstructed to 3D image. Catpan503 phantom and homogeneous phantom were used to measure the setup errors. Ball-bearing phantom was used to check the rotation axis of the CBCT. The volume image from CBCT using Catphan503 phantom and homogeneous phantom were analyzed and compared to images from conventional CT in the six dimensional view(X, Y, Z, Roll, Pitch, and Yaw). The variance ratio of setup error were difference in X 0.6 mm, Y 0.5 mm Z 0.5 mm when the gantry rotated $360^{\circ}$ in orthogonal coordinate. whereas rotated $180^{\circ}$, the error measured 0.9 mm, 0.2 mm, 0.3 mm in X, Y, Z respectively. In the rotating coordinates, the more increased the rotating unbalance, the more raised average ratio of setup errors. The resolution of CBCT images showed 2 level of difference in the table recommended. CBCT had a good agreement compared to each recommended values which is the mechanical safety, geometry accuracy and image quality. The rotating unbalance of gentry vary hardly in orthogonal coordinate. However, in rotating coordinate of gantry exceeded the ${\pm}1^{\circ}$ of recommended value. Therefore, when we do sophisticated radiation therapy six dimensional correction is needed.

Lung cancer, chronic obstructive pulmonary disease and air pollution (대기오염에 의한 폐암 및 만성폐색성호흡기질환 -개인 흡연력을 보정한 만성건강영향평가-)

  • Sung, Joo-Hon;Cho, Soo-Hun;Kang, Dae-Hee;Yoo, Keun-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.585-598
    • /
    • 1997
  • Background : Although there are growing concerns about the adverse health effect of air pollution, not much evidence on health effect of current air pollution level had been accumulated yet in Korea. This study was designed to evaluate the chronic health effect of ai. pollution using Korean Medical Insurance Corporation (KMIC) data and air quality data. Medical insurance data in Korea have some drawback in accuracy, but they do have some strength especially in their national coverage, in having unified ID system and individual information which enables various data linkage and chronic health effect study. Method : This study utilized the data of Korean Environmental Surveillance System Study (Surveillance Study), which consist of asthma, acute bronchitis, chronic obstructive pulmonary diseases (COPD), cardiovascular diseases (congestive heart failure and ischemic heart disease), all cancers, accidents and congenital anomaly, i. e., mainly potential environmental diseases. We reconstructed a nested case-control study wit5h Surveillance Study data and air pollution data in Korea. Among 1,037,210 insured who completed? questionnaire and physical examination in 1992, disease free (for chronic respiratory disease and cancer) persons, between the age of 35-64 with smoking status information were selected to reconstruct cohort of 564,991 persons. The cohort was followed-up to 1995 (1992-5) and the subjects who had the diseases in Surveillance Study were selected. Finally, the patients, with address information and available air pollution data, left to be 'final subjects' Cases were defined to all lung cancer cases (424) and COPD admission cases (89), while control groups are determined to all other patients than two case groups among 'final subjects'. That is, cases are putative chronic environmental diseases, while controls are mainly acute environmental diseases. for exposure, Air quality data in 73 monitoring sites between 1991 - 1993 were analyzed to surrogate air pollution exposure level of located areas (58 areas). Five major air pollutants data, TSP, $O_3,\;SO_2$, CO, NOx was available and the area means were applied to the residents of the local area. 3-year arithmetic mean value, the counts of days violating both long-term and shot-term standards during the period were used as indices of exposure. Multiple logistic regression model was applied. All analyses were performed adjusting for current and past smoking history, age, gender. Results : Plain arithmetic means of pollutants level did not succeed in revealing any relation to the risk of lung cancer or COPD, while the cumulative counts of non-at-tainment days did. All pollutants indices failed to show significant positive findings with COPD excess. Lung cancer risks were significantly and consistently associated with the increase of $O_3$ and CO exceedance counts (to corrected error level -0.017) and less strongly and consistently with $SO_2$ and TSP. $SO_2$ and TSP showed weaker and less consistent relationship. $O_3$ and CO were estimated to increase the risks of lung cancer by 2.04 and 1.46 respectively, the maximal probable risks, derived from comparing more polluted area (95%) with cleaner area (5%). Conclusions : Although not decisive due to potential misclassication of exposure, these results wert drawn by relatively conservative interpretation, and could be used as an evidence of chronic health effect especially for lung cancer. $O_3$ might be a candidate for promoter of lung cancer, while CO should be considered as surrogated measure of motor vehicle emissions. The control selection in this study could have been less appropriate for COPD, and further evaluation with another setting might be necessary.

  • PDF

Resolution Evaluation of a Pinhole Collimator according to the Aperture Diameter using Micro Deluxe Phantom (Micro Deluxe Phantom을 통한 핀홀 콜리메이터 초점의 직경별 분해능 평가)

  • An, Byung Ho;Yeon, Joon Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.3-11
    • /
    • 2015
  • Purpose It is hard to obtain high quality images of knee and T.M joint because of a lot of soft tissues in the knee and T.M joint area. Most conventional system for high resolution scintigraphy was used by 4 mm aperture pinhole collimator. Performance comparison of high-resolution pinhole SPECT for Micro deluxe phantom using conventional system. the aim of this study is to evaluate performance of each aperture according to the diameter size and the usefulness of 24-hour delayed bone scintigraphy. Materials and Methods In this study 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture and Micro Deluxe phantom was used for performance comparison of conventional SPECT system, Projection data were obtained with 9 degree increment per 30 second. Transverse images were reconstructed using dedicated OSEM algorithm with recovery of detector blurring. $^{99m}Tc-HDP$ source was used for 24-hour delayed bone scintigraphy. Results The knee joint images obtained with 24-hour delay were improved more than those obtained with 3-hour delay in our study. The 6 mm and 8 mm pinhole collimators FWHM have improved by 28% SNR and Uniformity have improved by 35%, Contrast has improved by 7% in 24-hour delayed knee joint image. While in 24-hour delayed T.M joint image of the 6 mm and 8 mm pinhole collimators FWHM have decreased by 60% SNR has decreased by 20% and Uniformity has decreased by 25%, Contrast has decreased significantly. Conclusion Pinhole collimators with 6 mm and 8 mm diameter could offer a superior performance for 24-hour delayed bone scintigraphy. The use of 24-hour delayed image provides additional benefits for pinhole scintigraphy of knee joint. Therefore, we expect that it is useful for precise diagnosis of knee joint and it is applicable to others joint imaging.

  • PDF

A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests (PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석)

  • Yun, Sun-Hee;Kim, Yang-Jung;Kang, Young-Jik;Park, Su-Young;Kim, Ho-Sin;Ryu, Hyoung-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF

The Evaluation of Dynamic Continuous Mode in Brain SPECT (Brain SPECT 검사 시 Dynamic Continuous Mode의 유용성 평가)

  • Park, Sun Myung;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.15-22
    • /
    • 2017
  • Purpose During Brain SPECT study, critical factor for proper study with $^{99m}Tc-ECD$ or $^{99m}Tc-HMPAO$ is one of the important causes to patent's movement. It causes both improper diagnosis and examination failure. In this study, we evaluated the effect of Dynamic Continuous Mode Acquisition compared to Step and Shoot Mode to raise efficacy and reject the data set with movement, as well as, be reconstructed in certain criteria. Materials and Methods Deluxe Jaszczak phantom and Hoffman 3D Brain phantom were used to find proper standard data set and exact time. Step and Shoot Mode and Dynamic Continuous Mode Acquisition were performed with SymbiaT16. Firstly, Deluxe Jaszczak phantom was filled with $Na^{99m}TcO_4$ 370 MBq and obtained in 60 minutes to check spatial resolution compared with Step and Shoot Mode and Dynamic Continuous Mode. The second, the Hoffman 3D Phantom filled with $Na^{99m}TcO_4$ 74 MBq was acquired for 15 Frame/minutes to evaluate visual assessment and quantification. Finally, in the Deluxe Jaszczak phantom, Spheres and Rods were measured by MI Apps program as well as, checking counts with the frontal lobe, temporal lobe, occipital lobe, cerebellum and hypothalamus parts was performed in the Hoffman 3D Brain Phantom. Results In Brain SPECT Study, using Dynamic Continuous Mode rather than current Step and Shoot Mode, we can do the reading using the 20 to 50 % of the acquired image, and during the test if the patient moves, we can remove unneeded image to reduce the rate of restudy and reinjection. Conclusion Dynamic Continuous Mode in Brain study condition enhances effects compared to Step and Shoot Mode. And also is powerful method to reduce reacquisition rate caused by patient movement. The findings further indicate that it suggest rejection limit to maintain clinical value with certain reconstruction factors compared with Tomo data set. Further examination to improve spatial resolution, SPECT/CT should be the answer for that.

  • PDF

Achievement of Excavation of Gwiam(Turtle Rock) and Nakseojae Restoration in Bogil-do Yun,Seondo Wonlim (보길도 윤선도원림(명승 제34호) 낙서재지역 원형복원과 귀암(龜巖) 발굴의 성과)

  • Lee, Won-Ho
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.3
    • /
    • pp.111-120
    • /
    • 2012
  • This study regards a series of achievement on Wonlim(Garden) Cultural Properties Excavation Project, led by field of landscape architecture. It will mainly describe excavation results of Gwiam(龜巖: Turtle rock) and historical value of it in terms of Nakseojae(樂書齋) restoration in Bogil-do Yun,Seondo Wonlim(Scenic Sites, No.34). Gwiam(Turtle rock) was found 14.6m apart from the north of Nakseojae, and it covered with 10~15m topsoil tilted toward Nakseojae, The size of Gwiam, which was Granite, was 360cm length, 270cm width, 95cm high. The Edge of Gwiam's North west part was of triangular shape forming Turtle head. The back of the Turtle head was form of Tortoise-shell because of wide backboard with both side groove. The southeast part of Gwiam projected was Turtle's tail. This Granite was obvious Turtle shape artificially made, and there are less likely to relocate from place to place. This Turtle-shaped Gwiam is important landmark for Nakseojae, which is one of the four spiritual creatures written in Bogildoji(甫吉島識) and Gosanyugo(孤山遺稿) by Yunwi. According to Bogildoji, it is estimated that Gwiam were on the axis with Soeunbyung(小隱屛), Nakseojae and was buried when Yiguan(Gosan's grandson) reconstructed a building. Also, it was place for enjoying the moon. But, Even after three times excavation in Nakseojae, there was no way to identify further information regarding Gwiam, so it was a matter of mystification. As a result of this study, Gwiam is laid bare to light in at least 260 years, so it is good example for boosting importance of landscape architecture field and restoring Nakseojae. Furthermore, firm base-soil was discovered in 135m high Rock Mass below, so natural ground of Nakseojae can be estimated by this basis. To be conclusion, Preservation Process for Gwiam and Estimation Space through interpretation of four spiritual creatures(四靈) in Gosan's Poetry should be continue.

Studies on the Characteristics of Modified Landscape and the Transformational Processes of Ongnyucheon in Changdeok Palace (창덕궁 옥류천의 수경(修景) 특성과 변천과정)

  • Jung, Woo-Jin;Kim, Hyung-Suk;Sim, Woo-Kyung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.3
    • /
    • pp.42-56
    • /
    • 2012
  • This study was carried out to investigate the construction characteristics and the landscaping design skill for Wiyiam at Ongnyucheon(玉流川) in the rear garden of Changdeok Palace focusing on constructing technique, space composition and transformational process of the site. The results of this study were summarized as follows; First, Wiyiam of Ongnyucheon was constructed as garden ornament which was modified the huge bedrock into the shape of the mountain. The waterfall of Wiyiam was originally made of torrent which water flowed into the bottom, but it was reconstructed to take the effect of Inak(離落: the method to drop water from high place) by carving rock into square shape at the era of King Gojong(高宗). Second, main characteristics of Wiyiam appeared in Donggwoldo was the hill built up with a square pond and ground at the back of Wiyiam and the profound scenery of mountains and stream from the view of Wiyiam. Also, pavilions such as Soyojeong(逍遙亭), Cheongujeong and Taegeukjeong(太極亭) built in Ongnyucheon seemed to be constructed as the spots to appreciate the view and waterfall sound of Wiyiam. Also the spots were not bounded by the function of creating special water systems such as Cheongujeong pond and Taegeukjeong pond and showed the outstanding landscape design skill to make people feel unusual interest from each spot. On the other hand, this study considered that the evening scenery of Wiyiam, beautiful sound of falling water, unusual water system with beautiful plant materials were landscaped for the function of the psychological peace and stability to the appreciators. Lastly, the extreme change of space composition in Ongnyucheon was assumed as a strategy to improve the existing poor drain environment by confirming that the mountain stream and wall of Soyojeong were removed and drainage in both side of Soyojeong was installed in the 21th year of King Gojong's reign(1884).

A Study of the Capsuloligamentous Anatomy of the Glenohumeral Joint Using Magnetic Resonance Imaging and Three-Dimensional Imaging. Dynamic In Vivo Study (자기공명 영상 및 3차원 영상을 이용한 견관절 관절낭-인대의 해부학적 연구. 역동학적 생체연구)

  • Park Tae-Soo;Choi Il-Yong;Joo Kyung-Bin;Kim Sun-Il;Kim Jun-Sic;Paik Doo-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.154-158
    • /
    • 2000
  • Purpose : The purpose of this study is to demonstrate changes in the orientation ortho glenohumeral ligaments(GHL) in different degrees of abduction and rotation of the normal healthy individuals. Materials and Methods : Saline Magnetic Resonance(MR) arthrography of nine consecutive shoulders of normal healthy adults were checked. At that time, MR images were obtained in three different positions of abduction and external rotation($0^{\circ}C\;and\;0^{\circ},\;45^{\circ}C\;and\;25^{\circ}C,\;90^{\circ}$ and maximum, respectively). From a series of consecutive MRI, three-dimensional images were reconstructed after detecting the location of the middle glenohumeral ligament(MGHL) and the inferior glenohumeral ligament(IGHL) using workstation computer. Results : The shape of the MGHL was taken in double curved, and straight, and finally curved again in three different positions of the shoulder in sequence. On the other hand, the shape of the IGHL was obliquely positioned, and curvilinear, and finally straight and extended at lower part of the anterior surface of the humeral head. Conclusions : At $45^{\circ}$ of abduction and $25^{\circ}$ of external rotation, and at $90^{\circ}$ of abduction and maximal external rotation of the shoulder, the MGHL and the IGHL had the role of the most important static stabilizer of the glenohumeral joint repectively.

  • PDF

Basin Evolution of the Taebaeksan Basin during the Early Paleozoic (전기 고생대 태백산분지의 분지 진화)

  • Kwon, Yi Kyun;Kwon, Yoo Jin;Yeo, Jung Min;Lee, Chang Yoon
    • Economic and Environmental Geology
    • /
    • v.52 no.5
    • /
    • pp.427-448
    • /
    • 2019
  • This study reconstructed the paleoenvironments and paleogeography of the Taebaeksan Basin, through a review of the previous researches on sedimentology, paleontology and stratigraphy. This study also carried out a sequence stratigraphic analysis on regional tectonism and sea-level fluctuations on the basin during the Early Paleozoic. The basin broadly occur in the Taebaek, Yeongweol-Jecheon, Jeongseon-Pyeongchang, and Mungyeong areas, Gangwon province, South Korea. The basin-fills are composed mainly of mixed carbonates and siliciclastics, divided into the Taebaek, Yeongweol, Yongtan, Pyeongchang and Mungyeong groups according to lithologies and stratigraphic characteristics. Recently, there are a lot of studies on the provenance and depositional ages of the siliciclastic sequences of the basin. The detrital sediments of the basin would be derived from two separated provenances of the core-Gondwana and Sino-Korean cratons. In the Early Cambrian, the Taebaek and Jeongseon-Pyeongchang platforms have most likely received detrital sediments from the provenance of the Sino-Korean craton. On the other hand, the detrital sediments of the Yeongweol-Jecheon platform was probably sourced by those of the core-Gondwana craton. This separation of provenance can be interpreted as the result of the paleogeographic and paleotopographic separation of the Yeongweol-Jecheon platform from the Taebaek and Jeongseon-Pyeongchang platforms. The analyses on detrital zircons additionally reveal that the separation of provenance was ceased by the eustatic rise of sea-level during the Middle Cambrian, and the detrital sediments of the Taebaeksan Basin were entirely supplied from those of the core-Gondwana craton. During that period, sediment supply from the Sino-Korean craton would be restricted due to inundation of the provenance area of the craton. On the other hand, the Jeongseon-Pyeongchang platform sequences show the unconformable relationship between the Early Cambrian siliciclastic and the Early Ordovician carbonate strata. It is indicative of presence of regional uplift movements around the platform which would be to the extent offset of the effects of the Middle to Late Cambrian eustatic sealevel rise. These movements expanded and were reinforced across the basin in the latest Cambrian and earliest Ordovician. After the earliest Ordovician, the basin was tectonically stabilized, and the shallow marine carbonate environments were developed on the whole-platform by the Early Ordovician global eustatic sea-level rise, forming very thick carbonate strata in the basin. In the Late Ordovician, the Early Paleozoic sedimentation on the basin was terminated by the large-scale tectonic uplift across the Sino-Korean platform including the Taebaeksan Basin.