• Title/Summary/Keyword: receiving phase

Search Result 263, Processing Time 0.033 seconds

Development of Biotelemetry Method by Combining the SSBL Method and the Pinger Synchronizing Method (2) - Evaluation for Precision of System - (SSBL 방식과 핑거동기 방식을 조합한 바이오텔레메터리 방식의 개발 (2) -시스템의 정도 평가 -)

  • 박주삼;고탁창언
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.318-325
    • /
    • 2003
  • The new biotelemetry method and system that the installation and the treatment of equipment is convenient and the instantaneously detailed position of the fish attached the pinger is able to track comparatively easily had been developed, an availabilities of it were verified in water tank by using hydrophone and pinger. First of all, the receiving system for biotelemetry was calibrated so as to measure tracking of high precision or wide detection range. In the next place, the precision at narrow and wide beam array of receiving system by using hydrophone was investigated and the actual position was compared with measured hydrophone position. The mean standard deviations of the position by narrow beam array of receiving system were 6.4em in phase beam of fore-aft pair and 6.3em in starboard-port pair, and the wide beam array were 24em and 23em respectively. The precision of distance, position, and velocity at narrow beam array of receiving system by using pinger were investigated and the actual values were compared with measured values. The distance from receiving system to pinger was measured by the pinger synchronizing method, angle of direction of pinger was detected by the super short base line (SSBL) method. The three dimensional position of pinger to the receiving system was measured by combining of two kinds of methods (SPB method), the velocity of pinger was obtained with a differential of the three dimensional positions. The mean standard deviations of the distance by pinger synchronizing method in narrow beam array of receiving system was 1. 8 em, that of the position by SPB method was 7.7cm.

Electromyographic analysis of gait cycle in hemiplegic patients after stroke (뇌졸중 이후 편마비 환자의 보행에서 근전도 분석)

  • Kwon Young-Shil;Jung Byong-Ok;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.11 no.1
    • /
    • pp.129-136
    • /
    • 1999
  • The purpode of this study was to determine the EMG characteristies of 7 subjects with hemiplegic gait receiving therapeautic exercise after stroke. The akin electrode and gait analysis system were used. The normal gait of 6 health volunteers was analysised. The results were following. 1. Gluteus maximus, the extensor of hip joint had high level of activity compared to normal, and had two peak in late stance phase and early Swing phase. 2. Medial hamstring, the flexor of knee joint had low level of activity compared to normal, and had continuous low amplitude pattern. 3. Vastus lateralis, the extensor of knee joint had high level of activity compared to normal, and had not continuous high amplitude. From early stance phase and mid stance phase, activity had high level but after swing phase. similar to normal. 4. Gastrocnemius, plantar flexor of ankle joint had low level of activity compared to normal and had continuous low amplitude. 5. Tibialis anterior, dorsiflexor of ankle joint had similar muscle activity to normal and had continuous low amplitude.

  • PDF

Modulation, Harmonic Analysis, and Balancing Control for a New Modular Multilevel Converter

  • Li, Binbin;Zhang, Yi;Wang, Gaolin;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.163-172
    • /
    • 2016
  • The modular multilevel converter (MMC) has been receiving increased attentions in recent years. The new modular multilevel converter is a derivative topology from the traditional MMC in which the number of sub-modules (SMs) necessitated by each phase can be reduced by one. This paper presents a phase-shifted carrier pulse-width modulation (PSC-PWM) for the new MMC with an optimal phase-shifted angle to suppress the harmonics of the output voltage. Further, the harmonic features when the capacitor voltage of the middle SM is selected as two different values are also investigated. Moreover, in order to avoid introducing an unnecessary dc offset current at the ac terminals of the new MMC, a novel capacitor voltage balancing scheme is proposed by adjusting the amplitude of the reference signals rather than the offset. Finally, the validity and effectiveness of the proposed modulation and balancing schemes have been verified by experimental results based on a three-phase prototype of the new MMC.

Effect of Copper Source (Cupric Citrate vs Cupric Sulfate) and Level on Growth Performance and Copper Metabolism in Pigs

  • Armstrong, T.A.;Spears, J.W.;van Heugten, E.;Engle, T.E.;Wright, C.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.8
    • /
    • pp.1154-1161
    • /
    • 2000
  • Two experiments were conducted to evaluate the efficacy of cupric citrate (Cu-citrate) relative to cupric sulfate $(CuSO_4)$ as a Cu source for weanling and grow-finish pigs. In addition, the use of liver and bile Cu concentrations as indices of the bioavailability of Cu sources was investigated. Experiment one consisted of a nursery phase (35 d; initial BW=6.4 kg, final BW=21.4 kg) followed by a grow-finish phase (103 d; initial BW=21.5 kg, final BW=111.7 kg). Experiment two only consisted of a nursery phase (35 d; initial BW=6.3 kg, final BW=18.6 kg). Dietary treatments were identical for both experiments and consisted of: control (10 ppm $CuSO_4$); control+66 or 225 ppm $CuSO_4$; control+33, 66, or 100 ppm Cu-citrate. An antibiotic was included in diets for Exp. 1 but not Exp. 2. In both experiments, growth performance variables were similar for pigs receiving Cu-citrate and $CuSO_4$; however, growth performance was not improved by high concentrations of $CuSO_4$. Liver and bile Cu were increased (p<0.05) by 225 ppm $CuSO_4$; however, lower dietary concentrations of Cu from either $CuSO_4$ or Cu-citrate did not affect the Cu concentration of liver or bile relative to that observed in the control pigs. Irrespective of Cu source, there was no linear (p>0.10) increase in plasma Cu with increasing Cu concentrations in the diet for both experiments. However, the plasma Cu concentrations were highest (p<0.10) in pigs receiving diets supplemented with 225 ppm $CuSO_4$. Sixteen randomly chosen pigs per treatment in Exp. 1 were continued through the grow-finish phase. Body weight gain and feed intake were improved (p<0.10) by 66 ppm $CuSO_4$, but other dietary Cu treatments did not alter pig performance compared to the control diet. Plasma Cu concentrations were increased (p<0.10) by 225 ppm $CuSO_4$ in the growing phase and by 225 ppm $CuSO_4$ and 100 ppm Cu-citrate in the finishing phase. These data reveal no consistent effect of $CuSO_4$ on performance; therefore, it is difficult to assess the efficacy of these two Cu sources. In addition, these studies demonstrate that liver and bile Cu are not good indicators of Cu bioavailability in pigs fed adequate to pharmacological concentrations of Cu.

Efficacy and Safety of Neurokinin-1 Receptor Antagonists for Prevention of Chemotherapy-Induced Nausea and Vomiting: Systematic Review and Meta-analysis of Randomized Controlled Trials

  • Yuan, Dong-Mei;Li, Qian;Zhang, Qin;Xiao, Xin-Wu;Yao, Yan-Wen;Zhang, Yan;Lv, Yan-Ling;Liu, Hong-Bin;Lv, Tang-Feng;Song, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.1661-1675
    • /
    • 2016
  • Objectives: Can addition of neurokinin-1 receptor antagonists (NK1-RAs) be considered as an ideal strategy for the prevention of chemotherapy-induced nausea and vomiting (CINV)? Researchers differ on this question. Materials and Methods: Electronic databases were searched for randomized control trials (RCTs) that evaluated the effectiveness and safety of NK1-RAs in preventing CINV. The primary end point was complete response (CR) in the acute, delayed, and overall phases after chemotherapy. Subgroup analyses evaluated the types of NK1-RAs, routines of administration, types of malignancies, regimens used in combination with NK1-RAs, and age of patients included in the studies. The incidences of different types of adverse events were also extracted to estimate the safety of NK1-RAs. Results: A total of 38 RCTs involving 13,923 patients were identified. The CR rate of patients receiving NK-RAs was significantly higher than patients in the control groups during overall phase (70.8% vs 56.0%, P<0.001), acute phase (85.1% vs 79.6%, P<0.001), and delayed phase (71.4% vs 58.2%, P<0.001). There were three studies including patients of children or adolescents, the CR rate was also significantly higher in the treatment group (overall phase: OR=2.807, P<0.001; acute phase: OR=2.863, P =0.012; delayed phase: OR=2.417, P<0.001). For all the other outcomes, patients in the NK1-RAs groups showed improvements compared to the control groups (incidence of nausea: 45.2% vs 45.9%, P<0.001; occurrence of vomiting: 22.6% vs 38.9%, P<0.001; usage of rescue drugs: 23.5% vs 34.1%, P<0.001). The pooled side effects from NK1-RAs did not significantly differ from previous reports and the toxicity rates in patients less than eighteen years old also did not diff between the two groups (P=0.497). However, we found that constipation and insomnia were more common in the patients of control groups, whereas diarrhea and hiccups were more frequently detected in patients receiving NK1-RAs. Conclusions: NK1-RAs improved the CR rate of CINV. They are effective for both adults and children. The use of NK1-RAs might be associated with the appearance of diarrhea and hiccups, while decreasing the possibility of constipation and insomnia.

Design and fabrication of multi-band six-port phase correlator using metamaterial (메타물질 구조 다중대역 6단자 위상상관기 설계 및 제작)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.12
    • /
    • pp.2615-2621
    • /
    • 2010
  • The multi-band six-port phase correlator using metamaterial was designed and fabricated in this paper. The lumped metamaterial structure that can process the dual-band receiving signal was analyzed. Based on the analyzed results, the small-sized metamatrial six-port phase correlator for multi-band direct conversion method was proposed and fabricated. Also, the resistive power divider and $90^{\circ}$ hybrid coupler that comprises the six-port phase correlator were implemented based on the scattering parameters of metamatrial six-port phase correlator. The measured results of the proposed six-port phase correlator show the good agreement with simulation results. The performance of the six-port phase correlator shows the reflection loss below -20 dB in the dual-band. Also, the proposed six-port phase correlator got a good transmission characteristic within 1 dB gain difference and ${\pm}4.1^{\circ}$ phase imbalance, respectively.

The Effects of Copper Source and Concentration on Lipid Metabolism in Growing and Finishing Angus Steers

  • Johnson, L.R.;Engle, T.E.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.8
    • /
    • pp.1131-1136
    • /
    • 2003
  • Forty-eight individually fed Angus steers (body weight $220kg{\pm}9.1$) were utilized to investigate the effects of copper (Cu) source and concentration on lipid metabolism and carcass quality. Steers were stratified by body weight and initial liver Cu concentration and randomly assigned to one of five groups. Groups were then randomly assigned to treatments. Treatments consisted of: 1) control (no supplemental Cu); 2) 10 mg Cu/kg DM from $CuSO_4$; 3) 10 mg Cu/kg DM from a Cu amino acid complex (Availa Cu) 4) 20 mg Cu/kg DM from $CuSO_4$; and 5) 20 mg Cu/kg DM from Availa Cu. Steers were fed a corn-alfalfa-based growing diet for 56 d. Steers were then switched to a high concentrate finishing diet for 145 d. On day 74 of the finishing phase subcutaneous adipose tissue biopsies were obtained from three steers/treatment to determine basal and stimulated lipolytic rates in vitro. Steers were then slaughtered after receiving the finishing diet for 145 d. Control steers tended (p<0.12) to have lower ceruloplasmin (Cp) activity than Cu supplemented steers. Steers receiving 20 mg Cu/kg DM from Availa Cu had higher (p<0.03) Cp activity than steers receiving 20 mg Cu/kg DM from $CuSO_4$. Plasma non-esterified fatty acids were similar across treatments. Steers receiving 10 mg Cu/kg DM from Availa Cu had higher (p<0.02) total plasma cholesterol concentrations relative to steers receiving 10 mg Cu/kg DM from $CuSO_4$. Steers receiving 20 mg Cu/kg DM from Availa Cu had lower (p<0.03) plasma triglyceride concentrations than steers supplemented with 20 mg Cu/kg DM from $CuSO_4$. Fatty acid profile of longissimus muscle was similar across treatments. Backfat depth tended (p<0.18) to be lower in Cu supplemented steers relative to controls. Steers supplemented with 20 mg Cu/kg DM from Availa Cu had heavier (p<0.03) hot carcass weights and a greater (p<0.02) dressing percentage than steers supplemented with 20 mg Cu/kg DM from $CuSO_4$. Furthermore, in vitro basal (p<0.06) and epinephrine stimulated (p<0.04) lipolytic rates of subcutaneous adipose tissue were higher in Cu supplemented steers relative to controls. The results of this study suggest that Cu supplementation has minimal effects on blood and lean tissue lipid profile. However, it appears that Cu may play a role in lipid metabolism in subcutaneous adipose tissue.

Independent PRF Generation and Control for Frequency Phase Calibration on Mono-pulse Radar at a Remote Location (원격지에서 모노펄스 레이더의 주파수 위상 교정을 위한 독립된 펄스반복주파수 생성 및 제어)

  • Yang, Jaewon;Yoo, Seungoh;Yoon, Jaehyuk;Lee, Dongju
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.368-373
    • /
    • 2021
  • This paper presents a method of independent pulse repetition frequency(PRF) generation and control for frequency phase calibration on mono-pulse radar at a remote location. In order to generate an independent PRF signal of 320[Hz], pulse width modulation(PWM) of 16-bit timer/counter was applied. For a precision control of PRF signal, 16-bit timer/counter interrupt was changed for each period. Therefore, average frequency of PRF could be controlled by 0.0001[Hz]. To calibrate a frequency phase of mono-pulse radar at a remote location, the proposed PRF generator with a precision control of frequency was used regardless of receiving PRF signal from a radar. For the verification of the proposed PRF generator, theoretical analysis and experimental results are included.

Torsional Elastic Waves Propagating in a Periodically-Nonuniform Circular Rod (주기적으로 불균일한 원형막대에서 전파하는 비틂 탄성파)

  • 김진오
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.323-326
    • /
    • 1998
  • The paper describes a theoretical and experimental study on the speed of the torsional elastic waves propagating in an axisymmetirc waveguide whose cross-sectional area varies periodically as an harmonic function of the axial coordinate. The approximate solution of the phase speed has been obtained using the perturbation technique for sinusoidal modulation of small amplitude. The experiment verifying the theoretical result consists of transmitting and receiving torsional waves by magnetostriction and measuring the wave speed in the waveguides with threaded surfaces.

  • PDF

Development of Layout Design Algorithm for Warehouse (보관시설의 작업공간 배치 알고리즘 개발)

  • Lee, Suk;Kim, Young-Joo;Kwon, Yong-Jang
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1574-1579
    • /
    • 2010
  • This paper deals with the development of warehouse layout design algorithm. In the developed model, receiving/outgoing areas, storage areas, picking/distribution areas, value-added operation areas and support areas are considered. For more efficient use of the warehouse floor space, a mezzanine floor is also considered. We develop heuristic algorithms of warehouse layout design for several cases: three types of warehouse and three types of flow. This study is expected to be used as a guideline in warehouse layout design phase.

  • PDF