• Title/Summary/Keyword: rebar corrosion

Search Result 241, Processing Time 0.027 seconds

Effect of Carbonation Threshold Depth on the Initiation Time of Corrosion at the Concrete Durability Design (콘크리트의 내구성 설계시 탄산화 임계깊이가 철근부식 개시시기에 미치는 영향에 관한 연구)

  • Yang, Jae-Won;Lee, Sang-Hyun;Song, Hun;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.229-230
    • /
    • 2010
  • The Carbonation, one of the main deterioration factors of concrete, reduces capacity of members with providing rebar corrosion environment. Consequently it suggested standards of all countries of world, carbonation depth prediction equation of respective researchers and time to rebar corrosion initiation. As a result of carbonation depth prediction equation calculation, difference of time to rebar corrosion initiation is 149 years and difference of carbonation depth prediction equation is 162 years when water cement ratio is 50%. So a study on rebar corrosion with carbonation depth will need existing reliable data and verifications by experiment.

  • PDF

Corrosion Monitoring Technology of Rebar in Reinforced Concrete Structures (철근콘크리트 구조물의 철근부식 모니터링 기술)

  • Kwon, Seong-Junn;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.258-259
    • /
    • 2019
  • Corrosion of rebar in RC structures, which results in premature deterioration of reinforced concrete structures, is a very serious problem. Most corrosion monitoring and sensing technologies require some type of wired or wireless connection between the sensor and monitoring electronics. This causes significant problems in their installation and long-term use. In this paper we describe a corrosion monitoring technology of rebar in reinforced concrete structures. Especially, it is emphasize that the development of sensors and monitoring system not only occurrence of rebar corrosion but also penetration of deterioration factor such like chloride ion and carbon dioxite etc..

  • PDF

Insights into the corrosion inhibition of steel rebar in chloride-contaminated synthetic concrete pore solutions by a new hydrazone (새로운 히드라존에 의한 염화물 오염 합성 콘크리트 공극 솔루션에서 철근의 부식 억제에 대한 통찰력)

  • Lgaz, Hassane;Lee, Han-seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.101-102
    • /
    • 2022
  • A new hydrazone derivatives namely (E)-N'-(4-(dimethylamino)benzylidene)-2-(5-methoxy-2-methyl-1H-indol-3-yl)acetohydrazide (HIND) has been confirmed for mitigating the corrosion of the steel rebar exposed to chloride contaminated synthetic concrete pore solution (ClSCPS). The mitigation of corrosion properties has been characterized by weight loss and electrochemical methods (Electrochemical impedance, Potentiodynamic polarization studies) as well as surface observations. The presence of HIND in the ClSCPS decreased the corrosion of steel rebar by adsorption of HIND molecules on the surface of the steel rebar. The optimal HIND concentration was 0.5 mmol/L, corresponding to an inhibition efficiency of 88.4%. The use of HIND enables the corrosion process to have a higher energy barrier. X-ray photo electron spectroscopy (XPS), atomic force microscopy (AFM), scanning electron microscopy-energy-dispersive spectroscopy (SEM-EDS), and X-ray diffraction (XRD) spectroscopy interpretations confirmed that HIND mitigates the corrosion attack on the surface steel rebar.

  • PDF

Corrosion Quantification of Reinforcing Bar in Concrete Using Micro Computer Tomography (Micro-CT 활용 콘크리트 내 철근 부식 정량을 위한 실험적 연구)

  • Jang, In-Dong;Yi, Chong-Ku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.252-253
    • /
    • 2019
  • Corrosion of rebars in reinforced concrete structures is a major factor that shortens the life of the structure. As corrosion progresses, the adhesion between the concrete tissues and the rebar decreases and the cracks in the concrete due to the expansion of the oxide intensify. Although it is necessary to measure corrosion behavior of rebars inside the concrete to measure degradation of structures due to rebar corrosion, no studies have been conducted to measure corrosion of rebars in In-situ state. In this study, corrosion of rebars in reinforced concrete specimens was attempted to be quantified using micro-computer tomography. Since corrosion of concrete takes several months per 10mm of cover, accelerated corrosion techniques were applied. Accelerated corrosion on the specimen was conducted by applying a 10 V magnetic field to the buried rebar and external electrodes with the specimen submerged in a 10% calcium chloride solution. The experiment found that within two weeks, more than 40% of rebar reduction occurred, and the cracks in the radial cracks occurred through the concrete structure, leading to the transfer of the oxide produced through the cracks to the surface of the specimen.

  • PDF

Investigation and Evaluation for Rebar Corrosion & Chloride of Freeway Concrete Bridges in Seoul Metropolitan Area (서울시내 고가차도의 염화물량 및 철근의 부식상태 조사 및 평가)

  • 이창수;윤인석;김구환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.631-634
    • /
    • 1999
  • A series of in-situ inspection and measurements have been conducted to estimate rebar corrosion incidence of freeway concrete bridges in Seoul metropolitan area. The results of this study have been analysed to identify the extent of chloride concentration and incidence of steel corrosion in various ages and in the different members of the structures. About 34% of the freeway structures had a value lower than - 350mV(vs CSE), so it could conclude that the excessive chloride concentration was a major cause of rebar corrosion.

  • PDF

An Experimental Study on the Corrosion Behavior of Rebar in Cement Mortar by Using EIS Method (EIS를 이용한 시멘트 모르타르에 매입된 철근의 부식거동에 관한 실험적 연구)

  • Park, Jang-Hyun;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.145-146
    • /
    • 2016
  • In this study, Corrosion behavior in mortar was observed by the passage of time by using EIS method. As a result of EIS experiment, equivalent circuit and changes of Impedance parameter could be observed. In addition, it was confirmed that impedance of rebar in mortar and corrosion rate according to the amount of NaCl were different.

  • PDF

Corrosion of Reinforcing Steel in Simulated Pore Solution with Chloride Ion (염분농도에 따른 콘크리트 모사 세공용액에서의 철근 부식특성)

  • Nam, Sang-Cheol;Cho, Won-Il;Cho, Byung-Won;Yun, Kyung-Suk;Chun, Hai-Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.5
    • /
    • pp.667-673
    • /
    • 1998
  • Rebar corrosion in a simulated pore solution (SPS) with chloride ion was analyzed by Tafel and AC impedance method and corrosion effects of surface roughness and iron oxide layer were also investigated. Corrosion estimation of rebar by electrochemical impedance spectroscopy is very useful, and the measured value can be adapted to proposed electrochemical equivalent circuit model. Corrosion potential increased to the cathodic direction as the concentration of chloride ions increased and corrosion current had the same tendency as above. Surface films were analyzed with scanning electron microscope and Auger electron spectroscopy. Thermally oxidized layer by torch flame for 15 sec was very poor at anti-corrosive property. The corrosion rate of rebar increased as the surface roughness increased. Also, higher temperatures above RT of SPS in initial stage caused a rebar to be corroded faster.

  • PDF

Enhancement of Corrosion Resistance of Steel Reinforcement in Concrete by Hydrophobic Surface Treatments (콘크리트의 소수성 표면처리를 통한 철강 보강재의 내식성 향상)

  • Jo, Hyunbin;Shin, Dongmin;Seo, Eunhye;Lee, Wookjin;Lee, Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.6
    • /
    • pp.300-305
    • /
    • 2020
  • Corrosion of reinforcement steel rebar is a serious problem in a wide range of concrete application for buildings and infrastructures. Hydrophobizing surface treatments, such as self-assembled monolayer coating, edible oil-impregnation and silicone oil-impregnation were applied to solidified concrete. The hydrophobizing of concrete significantly reduces an absorption and transportation of water toward a steel rebar in concrete, so that the corrosion resistance of the steel rebar. In particular, the silicone oil-impregnation not only forms the hydrophobic monolayer on the concrete but also fills the inter-connected pores of concrete, thus the corrosion of steel rebar is significantly inhibited compared to the self-assembled monolayer coating and edible oil-impregnation. Therefore, the silicone oil-impregnation can be a promising candidate for preventing corrosion of steel rebar in concrete for durable performance and safety.

A Study on the Surface Roughness of Corroded Reinforcing Rebar (부식된 철근의 표면 거칠기에 관한 연구)

  • Roh, Young-Sook;Lee, Sun-Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.78-83
    • /
    • 2010
  • This paper discusses the surface roughness of corroded reinforcement rebar in reinforced concrete structures focusing on the quantitative measurement technique for rebar corrosion. Reinforcement rebar was corroded using accelerated corrosion induced method and corrosion rates were 0%, 1%, 2%, 3%, 5%, and 10% of mass losses. Using 3-dimensional scanner each surface profile of reinforcement rebar was established, and surface roughness was measured. Through tests and analyses of corroded reinforcement rebar, the following topics were particularly discussed: measurement of surface roughness, relationship between area and surface roughness, relationship between surface roughness and bond performance. As a result, surface roughness of corroded rebar was found to be very effective to bond strength until 2% of corrosion rate. It was also discussed how to relate surface roughness of corroded rebar to bond strength of reinforced concrete structures.

Corrosion Behaviors of Rebar in Low Temperature Mortar with Chloride and Nitrite (염화물 및 아질산염을 사용한 저온환경하 모르타르내 철근의 부식특성)

  • Park, Jung-Hoon;Ki, Kyoung-Kuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.218-219
    • /
    • 2017
  • In order to examine the possibility of practical at low-temperature environment curable cement mortar with chloride and nitrite as cold resistance admixture for rebar corrosion prevention. As a result, chloride was used using nitrite complex in low temperature environment and corrosion performance of rebar was improved and mortar strength was promoted. The ratio of nitrite than chloride applied more than twice, corrosion of the reinforcing bars will not occur even in low temperature environment, cement hydration reaction will be promoted and mortar will prevent freezing damage.

  • PDF