• 제목/요약/키워드: realistic operation conditions

검색결과 56건 처리시간 0.026초

석탄 IGCC 다이내믹 시뮬레이션에 관한 연구 (Study on the Dynamic Simulation for an Integrated Coal Gasification Combined Cycle)

  • 주용진;김시문;이민철;김미영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.106.2-106.2
    • /
    • 2010
  • IGCC (Integrated Gasification Combined Cycle) plants are among the most advanced and effective systems for electric energy generation. From a control perspective, IGCC plants represent a significant challenge: complex reactions, highly integrated control to simultaneously satisfy production, controllability, operability and environmental objectives. While all these requirements seem clearly to demand a multivatiable, model predictive approach, not many applications can be easily found in the literature. This paper describes the IGCC dynamic simulation that is capable of simulating plant startup, shutdown, normal, and abnormal operation and engineering studies. This high fidelity dynamic models contain the detailed process design data to produce realistic responses to process operation and upset. And the simulation is used by engineers to evaluate the transient performance and produce graphical information indicating the response of the process under study conditions.

  • PDF

MIDLOOP Code Analysis of a ROSA-IV/LSTF Experiment for the Loss of Residual Heat Removal System Event During Mid- loop Operation

  • Han, Kee-Soo;Lee, Cheol-Sin;Park, Chul-Jin;Kim, Hee-Cheol
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.683-690
    • /
    • 1996
  • The MIDLOOP code has been developed for the evaluation of RES pressurization transients initiated from a loss-of-Residual Heat Removal System (RHRS) during mid-loop operation after reactor shutdown. It provides a fast running and realistic tool for studying parametrically the response of important plant parameters such as pressure, temperature, and level to various plant combinations of the primary side vent, makeup, and leakage procedures and the steam generator (SG) conditions. The code consists of ten nodes representing the primary and secondary sides of a nuclear power plant and can analyze the effect of air on the primary system pressurization and primary to secondary heat transfer. The analysis results of the MIDLOOP code are in good agreement with the ROSA-IV/LSTF experiment without opening in the RCS.

  • PDF

Study on Flow Mixing Effects in a High-Speed Journal Bearing

  • Chun, Sang-Myung
    • KSTLE International Journal
    • /
    • 제1권2호
    • /
    • pp.76-82
    • /
    • 2000
  • Turbulence in journal bearing operation is examined and the thermal variability is studied for isothermal, convective and adiabatic conditions on the walls under aligned and misaligned conditions. Also, the effects of a contraction ratio at the cavitation region and the mixing between re-circulating oil and inlet oil on the fluid field of oil film are included. An algorithm for the solution of the coupled turbulent Reynolds and energy equations is used to examine the effects of the various factors. Heat convection is found to play only a small role in determining friction and load under no mixing condition. However, under realistic mixing condition, the heat convection cannot be ignored. The wall temperature and heat transfer have been found to be of secondary important factors to the mixing effectiveness at the groove and the final mixture temperature.

  • PDF

현장조사 관개 기준에 따른 농업용 저수지 운영 분석 (Agricultural Reservoir Operation Analysis According to Surveyed Irrigation Guideline)

  • 김마가;최진용;방재홍;윤푸른;김귀훈
    • 한국농공학회논문집
    • /
    • 제65권5호
    • /
    • pp.37-49
    • /
    • 2023
  • The drought risk has been increasing recently due to climate change causing the extreme climate to be more frequent. In order to supply agricultural water stably under drought, it is necessary to operate an agricultural reservoir in response to drought. To this end, it is crucial to establish appropriate drought response operation rules considering weather conditions and reservoir status. In the reservoir operation simulation, the supply amount differs from the actual reservoir supply for many reasons, including maintaining water levels for supply and accommodating farmers' requests. So, for a more realistic reservoir operation simulation, it is necessary to reflect the reservoir operation rules of the actual water management site. Therefore, in this study, through a survey, the standards for limitation of agricultural water supply applied to agricultural reservoirs in Korea were investigated, and the criteria for drought response reservoir operation (DRO) were established based on the survey. Then, the DRO was applied to the irrigation period for nine subject reservoirs. The applicability was evaluated by comparing the DRO result to the operation result of HOMWRS (Hydrological Operation Model for Water Resources System). The reservoir drought index, storage rate, and daily supply were compared for evaluation. From the result, DRO showed more stable operation results in most cases against drought as it has fewer days of water supply limitation and a somewhat reservoir storage rate which can be utilized for prolonged drought.

설비교체의 최적시기 결정에 관하여 (On the Optimal time for Renewal of Facilities)

  • 최은재
    • 한국국방경영분석학회지
    • /
    • 제3권1호
    • /
    • pp.109-114
    • /
    • 1977
  • There are some factors which cause the profits from the production to be decreased or increased. They are, for example, the rise in efficiency of production facilities resulting from the development of the scientific technique, the changes of purchase price of those, and the drop in efficiency of those owing to there long-term operation. In this connection, an manager can get the highest profit by deciding the proper time of new facilities replacement for those in operation or in being planned, which leads to good management planning of his manufactaring business for a given period or a long time. Main purpose of this is the study of how we decide the optimal time or facilities replacement in order to maximize the total profits for a given period by considering them as continous function as to the time in the case where a machineng is set. The results are following: 1. The definition of profit function is in duced in consideration of the breakdowns caused from continous operation of the machinery. 2. The necessary conditions are obtained for the optimal time of replacement and find out the methods of its solution. 3. Comparing between the 'Short cut' method and method in this paper, we obtained that our method is more realistic.

  • PDF

A Digital Twin-based Approach for VANET Simulation in Real Urban Environments

  • Jonghyeon Choe;Youngboo Kim;Sangdae Kim
    • 한국컴퓨터정보학회논문지
    • /
    • 제29권8호
    • /
    • pp.113-122
    • /
    • 2024
  • 본 논문에서는 디지털 트윈과 같은 실제 도로 환경에서 차량용 애드혹 네트워크(VANET)의 시뮬레이션을 실행하기 위한 기존 시뮬레이터를 면밀한 조사가 수행되었다. 신중한 검토 후에, 오픈소스로 공개되어 있을 뿐만 아니라 효율적인 성능을 가지는 OSM(OpenStreetMap), SUMO(Simulation of Urban MObility), OMNeT++를 결합한 시뮬레이터를 선택되었다. 또한, 이 통합 시뮬레이터를 사용하여 단순한 가상 도로 환경과 실제 도로 환경 모두에서 VANET 시뮬레이션을 수행하였고, 그 결과 두 유형의 환경 간에 VANET 성능에 상당한 차이가 있음을 확인했으며, 안정적인 VANET 운영을 위해 현실적인 도로 및 교통 환경을 고려해야 할 필요가 있음을 확인하였다. 추가적으로, 또 다른 시뮬레이션 결과에서는 차량 밀도가 감소하고 네트워크 토폴로지의 동적 변화가 증가함에 따라 성능 저하가 관찰되는 등 상당한 성능 변동성이 있는 것으로 나타나기도 하였다. 이러한 결과들을 통해, VANET을 실제 환경에서 운용하기 위해서는, 단순한 가상 도로 환경에 의존하지 않아야하며, VANET 연구에서 디지털 트윈 기반 접근 방식을 통해 실제 도로 및 교통 상황을 시뮬레이션해야 할 필요성을 확인할 수 있다.

저궤도 위성과 지상국간 접속 환경을 활용한 임무수행능력 지상 검증 시험 (Mission Operation Capability Verification Test for Low Earth Orbit(LEO) Satellite by Utilizing Interface Environment between LEO Satellite and Ground Station)

  • 이상록;구인회;임성빈
    • 항공우주기술
    • /
    • 제13권2호
    • /
    • pp.142-149
    • /
    • 2014
  • 저궤도위성은 발사 이후 초기 운영[1] 및 검보정 단계를 거쳐 정상 운영 단계로 진입한다. 정상 운영 단계에서는 이상 현상에 대한 대응조치[2], 궤도조정 작업 이외의 대부분 기간 동안 지상국으로부터 임무 명령을 수신하고 영상 촬영 및 전송 임무를 수행하게 된다. 저궤도위성과 지상국 시스템이 모두 관여된 임무수행능력은 저궤도위성 프로그램 성공 판단의 핵심 지표이고, 저궤도위성 프로그램 추진 목적과 일치하는 항목이기 때문에 지상 시험 단계에서 철저한 검증을 통해 신뢰성을 확보해야 한다. 지상 시험단계에서 지상국과 위성의 역할을 검증함으로써 임무수행능력에 대한 신뢰성을 확보하기 위해서는 저궤도위성의 실제 운용 상황과 유사한 시나리오를 작성하고 이를 바탕으로 명령을 생성하여 위성에 전달하며, 영상과 건강상태 텔레메트리(Telemetry) 데이터를 수신하는 등의 임무수행 전체 주기에 대한 검증이 필요하다. 이 논문은 저궤도위성과 지상국간 접속 환경을 활용해 수행된 임무수행능력 지상 검증 시험 설계 및 수행 결과에 대해 다룬다. 시험 설계시 고려되어야 할 항목과 이를 바탕으로 설계된 시험에 대해 상세히 서술하고 결과에 대해 정리하였다.

포화입력을 가진 비선형 시스템에 대한 슈퍼바이저 제어의 안정성 연구 (A Study on the Stability of Supervisory Control for Nonlinear System with Saturating Input)

  • 차경래
    • 한국생산제조학회지
    • /
    • 제8권4호
    • /
    • pp.112-122
    • /
    • 1999
  • In realistic control systems the nonlinear saturation attributes of the control actuator due to physical limitations should be taken into account This nonlinear saturation of actuators may cause not only deterioration of the control performance but also a large overshoot during start-up and shut-down. As the overshoot increases the system may become oscillatory unstable. in this paper the supervisor implementation which guarantees good performance for saturation operation and prevents reset wind up is presented, Moreover the sufficient conditions of the stability for saturated system using supervisory control with a dynamic controller are provided in the continuous-time and in the discrete-time domain Numerical example is illustrated to depict the efficiency of supervisory control for a typical satuaurated production-distribution system controlled by a discrete-time dynamic controller and to validate basic results by simulation.

  • PDF

연료극지지 평판형 고체산화물 연료전지 내에서의 전기 및 물질전달에 대한 간략화된 저항 네트워크 계산 (Simplified Resistor Network Calculation for Electrical and Mass Transport in Anode-Supported Planar Solid Oxide Fuel Cell)

  • 이현재;남진현;김찬중
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1740-1745
    • /
    • 2004
  • A simplified resistor network model for electrical and mass transport in anode-supported planar solid oxide fuel cell (SOFC) was constructed in order to investigate the effect of interconnect rib geometry on the cell performance. For accurate potential calculation, activation and concentration over-potentials at the electrode/electrolyte interfaces were fully considered in this calculation. When contact resistance was not considered, the optimum interconnect rib length were calculated to be $0.1{\sim}0.2$ mm for 2 mm half unit cell for given operation conditions and properties. However, with realistic contact resistance, the interconnect rib length should be increased to provide larger contact area and thus to obtain better performance.

  • PDF

가스터빈의 설계 성능과 부분부하 성능 사이의 상관관계 분석 (Analysis of Relationship Between Design and Part Load Performance of Gas Turbines)

  • 김동섭
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1164-1171
    • /
    • 2002
  • This study analyzed the dependence of part load performance of simple cycle gas turbines on their design performance. Various parametric calculations were carried out to examine effects of design temperature ratio, pressure ratio and component efficiencies using a simplified analysis. In addition, a more practical analysis was done for realistic design conditions with the aid of a comprehensive performance analysis program. The results show that gas turbines with higher design performance exhibit less efficiency degradation during part load operation. The influence of power control method (fuel only centre) and air flow control) on part load performance was examined as well.