• Title/Summary/Keyword: real-time probe

Search Result 230, Processing Time 0.03 seconds

Identification of Brucella melitensis isolates originating from Mongolia and diagnostic real-time PCR evaluation using a specific SNP (몽골 유래 Brucella melitensis 동정 및 특이 SNP를 이용한 real-time PCR법에 의한 진단 평가)

  • Kang, Sung-Il;Kim, Ji-Yeon;Kim, Suk Mi;Lee, Jin Ju;Sung, So-Ra;Kim, Yeon-Hee;Jung, Suk Chan;Her, Moon
    • Korean Journal of Veterinary Research
    • /
    • v.55 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • A real-time PCR assay using hybridization probe (HybProbe) has been developed to detect Brucella (B.) melitensis strains. The primer and HybProbe sets were designed based on the gap gene of chromosome I with a specific single nucleotide polymorphism of B. melitensis. Specificity of the assay was confirmed by comparison to reference Brucella species and other related strains. In the melting curve analysis, B. melitensis generated a peak at $67^{\circ}C$ unlike those for other Brucella species observed at $61^{\circ}C$. Sensitivity of the assay for B. melitensis ranged from 20 ng to 200 fg of genomic DNA. The ability to identify 94 Mongolian B. melitensis isolates using the real-time PCR assay was identical to that of classical biotyping methods and differential multiplex PCR. These data showed that this new molecular technique is a simple and quick method for detecting B. melitensis, which will be important for the control and prevention of brucellosis.

Detection of HBV Resistance to Lamivudine in Patients with Chronic Hepatitis B Using Zip Nucleic Acid Probes in Kerman, Southeast of Iran

  • Afshar, Reza Malekpour;Mollaie, Hamid Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3657-3661
    • /
    • 2012
  • HBV infection is contagious and may be transmitted vertically or horizontally by blood products and body secretions. Over 50% of Iranian carriers have contracted the infection prenatally, making this the most likely route of transmission of HBV in Iran. This study assesses the resistance to Lamivudine in patients with chronic hepatitis B infection using a new ZNA probe Real Time PCR method. To evaluate the effectiveness of Lamivudine therapy for chronic hepatitis B infection, a study was conducted on 70 patients (63 men and 7women), who had received the drug first line. All patients were tested for the presence of HBsAg and HBeAg, the serum ALT level and the HBV DNA load before and after treatment. In all samples resistance to Lamivudine was tested with the ZNA Probe. Our results showed that ZNA Probe Real Time PCR method could detect wild type,YMDD, and its mutants, tyrosine-isoleucine-aspartate-aspartate and tyrosine-valine-aspartate-Aspartate. Among an estimated seventy patients with chronic hepatitis B infection, 18 (25.7%) were resistant to lamivudine. Only one patient was negative for presence of HBS-Ag (5.6%) and two patients were negative for HBe-Ag (11.1%). Real-time PCR with Zip nucleic acid probes is a sensitive, specific and rapid detection method for mutations in the YMDD motif, which will be essential for monitoring patients undergoing Lamivudine antiviral therapy.

A study of the system that enables real-time contact confirmation of probes in OLED panel inspection (OLED Panel 검사 시에 Probe의 실시간 Contact 확인 가능한 시스템에 관한 연구)

  • Hwang, Mi-Sub;Han, Bong-Seok;Han, Yu-Jin;Choi, Doo-Sun;Kim, Tae-Min;Park, Kyu-Bag;Lee, Jeong-woo;Kim, Ji-Hun
    • Design & Manufacturing
    • /
    • v.14 no.2
    • /
    • pp.21-27
    • /
    • 2020
  • Recently, LCD (Liquid Crystal Display) has been replaced by OLDE (Organic Light Emitting Diode) in high resolution display industry. In the process of OLDE production, it inspects defective products by sending a signal using a probe during OLED panel inspection. At this time, the cause of the detection of failure is divided into two. One is the self-defect of the OLED panel and the other is the poor contact occurring in the process of contact between the two. The second case is unknown at the time of testing, which increases the time for retesting. To this end, we made a system that can identify in real time whether the probe is in contact during the inspection. A contact probe unit was designed for the system, and a stage system was implemented. An inspection system was constructed through S / W and circuit configuration for actual inspection. Finally, a system that can check contact and non-contact in real time was constructed.

Quantitative Real-time PCR using Lactobacilli as Livestock Probiotics (Real-time PCR을 이용한 가축생균제용 유산균 정량분석)

  • Choi, Yeon-Jae;Kim, Sun-Ho;Gu, Min-Jeong;Choe, Han-Na;Kim, Dong-Un;Cho, Sang-Bum;Kim, Su-Ki;Jeon, Che-Ok;Bae, Gui-Seok;Lee, Sang-Seok
    • Journal of Life Science
    • /
    • v.20 no.12
    • /
    • pp.1896-1901
    • /
    • 2010
  • This study was conducted using quantitative real-time PCR using Lactobacilli as probiotics. Quantitative real-time PCR (RT PCR) was conducted via a method involving SYBR Green 1 and a probe. Plasmid DNA was cloned using the 16S-23S rRNA intergenic species region. Gene clones were diluted from $10^2$ to $10^{10}$. Standard curves were constructed via Ct values obtained from the results of Real-time PCR via the aforementioned SYBR Green 1 and probe method. Plasmid DNA was also cloned using the 16S-23S rRNA intergenic species region and the gene clones were diluted from $10^2$ to $10^{10}$ copy numbers via the probe method. Using RT PCR, a standard curve of plasmid DNA copy numbers was also determined. The slope value for the Y-axis intercept and $R^2$ value were measured as -3.346, 33.18, and 0.993, respectively, via the first method. For the second method, the slope value for the Y-axis intercept and $R^2$ were -3.321, 31.10 and 0.995, respectively. The PCR inhibitor could not express the detection curve at a copy number over $10^{10}$ via either method, owing to high DNA density. The DNA extract from probiotics was diluted without pre-culturing, and 16 products were amplified via both methods. The Ct value was 11.06~18.12 in the first method and 16.74~22.11 in the second method. Measured probiotics and log copy values were largely similar among the methods used. It was concluded that both methods are effective for analysis, but further research will be required to verify the optimal method.

Development of TaqMan Probe-Based Real-Time PCR Method for erm(A), erm(B), and erm(C), Rapid Detection of Macrolide-Lincosamide-Streptogramin B Resistance Genes, from Clinical Isolates

  • Jung, Jae-Hyuk;Yoon, Eun-Jeong;Choi, Eung-Chil;Choi, Sung-Sook
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.11
    • /
    • pp.1464-1469
    • /
    • 2009
  • To achieve more accurate and rapid detection of macrolide-lincosamide-streptogramin B resistance genes, erm(A), erm(B), and erm(C), we developed a TaqMan probe-based real-time PCR (Q-PCR) method and compared it with conventional PCR (C-PCR), which is the most widely using erm gene identification method. The detection limit of Q-PCR was 5 fg of genomic DNA or 5-8 CFU of bacterial cells of Staphylococcus aureus. The utilization of Q-PCR might shorten the time to erm detection from 3-4 h to about 50 min. These data indicated that Q-PCR assay appears to be not only highly sensitive and specific, but also the most rapid diagnostic method. Therefore, the appropriate application of the Q-PCR assay will permit rapid and accurate identification of erm genes from clinical and other samples.

Development of a real-time PCR method for detection and quantification of the parasitic protozoan Perkinsus olseni

  • Gajamange, Dinesh;Yoon, Jong-Man;Park, Kyung-Il
    • The Korean Journal of Malacology
    • /
    • v.27 no.4
    • /
    • pp.387-393
    • /
    • 2011
  • The objective of this study was to develop a real-time PCR method for the rapid detection and quantification of the protozoan pathogen Perkinsus olseni using a TaqMan probe. For the standard, genomic DNA was extracted from $10^5$ in vitro-cultured P. olseni trophozoites, and then 10-fold serial dilutions to the level of a single cell were prepared. To test the reliability of the technique, triplicates of genomic DNA were extracted from $5{\times}10^4$ cells and 10-fold serial dilutions to the level of 5 cells were prepared. The standards and samples were analyzed in duplicate using an $Exicycler^{TM}$ 96 real-time quantitative thermal block. For quantification, the threshold cycle ($C_T$) values of samples were compared with those obtained from standard dilutions. There was a strong linear relationship between the $C_T$ value and the log concentration of cells in the standard ($r^2$ = 0.996). Detection of DNA at a concentration as low as the equivalent of a single cell showed that the assay was sensitive enough to detect a single cell of P. olseni. The estimated number of P. olseni cells was similar to the original cell concentrations, indicating the reliability of P. olseni quantification by real-time PCR. Accordingly, the designed primers and probe may be used for the rapid detection and quantification of P. olseni from clam tissue, environmental water, and sediment samples.

A Study on the Development of iGPS 3D Probe for RDS for the Precision Measurement of TCP (RDS(Robotic Drilling System)용 TCP 정밀계측을 위한 iGPS 3D Probe 개발에 관한 연구)

  • Kim, Tae-Hwa;Moon, Sung-Ho;Kang, Seong-Ho;Kwon, Soon-Jae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.6
    • /
    • pp.130-138
    • /
    • 2012
  • There are increasing demands from the industry for intelligent robot-calibration solutions, which can be tightly integrated to the manufacturing process. A proposed solution can simplify conventional robot-calibration and teaching methods without tedious procedures and lengthy training time. iGPS(Indoor GPS) system is a laser based real-time dynamic tracking/measurement system. The key element is acquiring and reporting three-dimensional(3D) information, which can be accomplished as an integrated system or as manual contact based measurements by a user. A 3D probe is introduced as the user holds the probe in his hand and moves the probe tip over the object. The X, Y, and Z coordinates of the probe tip are measured in real-time with high accuracy. In this paper, a new approach of robot-calibration and teaching system is introduced by implementing a 3D measurement system for measuring and tracking an object with motions in up to six degrees of freedom. The general concept and kinematics of the metrology system as well as the derivations of an error budget for the general device are described. Several experimental results of geometry and its related error identification for an easy compensation / teaching method on an industrial robot will also be included.

Temporal Changes in Abundances of the Toxic Dinoflagellate Alexandrium minutum (Dinophyceae) in Chinhae Bay, Korea

  • Park, Tae-Gyu;Kang, Yang-Soon
    • Journal of Environmental Science International
    • /
    • v.18 no.12
    • /
    • pp.1331-1338
    • /
    • 2009
  • Marine dinoflagellate Alexandrium minutum producing paralytic shellfish toxins is responsible for paralytic shellfish poisoning (PSP). To investigate its temporal distributions in Chinhae Bay where PSP occurs annually, SYBR Green I based A. minutum-specific real-time PCR probe was developed on the LSU rDNA region. Assay specificity and sensitivity were tested against related species, and its specificity was further confirmed by sequencing of field-derived samples. Ten months field survey in 2008 (a total 100 surface water samples) by using the real-time PCR probe showed that A. minutum was detected at very low densities of 1-4 cells $L^{-1}$ in May and June being spring in Chinhae Bay, Korea.

Label-Free and Real-Time Monitoring of Phosphatase Reactions Using a Phosphate-Specific and Fluorescent Probe

  • Lee, Ji-Hoon;Ahn, Hee-Chul;Shin, Dong-Yun;Ahn, Dae-Ro
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.5
    • /
    • pp.943-947
    • /
    • 2008
  • A phosphate-specific and fluorescent probe was prepared for label-free phosphatase assays based on fluorescence polarization. By using the probe, dephosphorylation reactions of DNA and protein substrates by calf intestinal alkaline phosphatase (CIP) could effectively be monitored in real-time. Since this assay method does not require additional materials such as labeled substrates and phosphospecific antibodies to obtain fluorescence polarization signals, it is simple, cost-effective, and expected to be useful not only for measuring activity of phosphatases but also for high-throughput screening of phosphatase inhibitors.

Species-specific Marker Development for Environmental DNA Assay of Endangered Bull-head Torrent Catfish, Liobagrus obesus (멸종위기어류 퉁사리의 환경 DNA 분석을 위한 종 특이 마커 개발)

  • Yun, Bong Han;Kim, Yong Hwi;Sung, Mu Sung;Han, Ho-Seop;Han, Jeong-Ho;Bang, In-Chul
    • Korean Journal of Ichthyology
    • /
    • v.34 no.3
    • /
    • pp.208-217
    • /
    • 2022
  • We wanted to develop a real-time PCR assay capable of detecting Liobagrus obesus in environmental DNA (eDNA) extracted from freshwater samples using a pair of species-specific primers and probe for the endangered fish, L. obesus. The species-specific primers and probe were designed in consideration of single nucleotide polymorphisms between 65 species of freshwater fish living in the Republic of Korea within the cytochrome b (cytb) gene of mitochondrial DNA. The species-specific primers and probe, in the real-time PCR assay, showed high specificity as only the L. obesus genomic DNA (gDNA) was found to be positive in the specificity verification using 65 species gDNA of freshwater fish in the Republic of Korea. In addition, in the detection limit analysis using the serial dilution concentrations of L. obesus gDNA, it was found that it was possible to detect up to 0.2 pg, showing high sensitivity. Afterwards, using the species-specific primers and probe, real-time PCR assay was performed on freshwater samples obtained from 8 stations in the mid-upper basin of Geum River. As a result, the cytb gene of L. obesus was detected in total 5 stations including all 3 stations where this species was collected at the time of field survey. Therefore, the species-specific primers and probe developed in present study, and the real-time PCR assay using them, can accurately detect the cytb gene of L. obesus from eDNA samples, which can be utilized to monitor the existing habitats of this species and to discover potential new habitats.