• Title/Summary/Keyword: readout

Search Result 274, Processing Time 0.019 seconds

Measurement uncertainty analysis of radiophotoluminescent glass dosimeter reader system based on GD-352M for estimation of protection quantity

  • Kim, Jae Seok;Park, Byeong Ryong;Yoo, Jaeryong;Ha, Wi-Ho;Jang, Seongjae;Jang, Won Il;Cho, Gyu Seok;Kim, Hyun;Chang, Insu;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.479-485
    • /
    • 2022
  • At the Korea Institute of Radiological and Medical Sciences, physical human phantoms were developed to evaluate various radiation protection quantities, based on the mesh-type reference computational phantoms of the International Commission on Radiological Protection. The physical human phantoms were fabricated such that a radiophotoluminescent glass dosimeter (RPLGD) with a Tin filter, namely GD-352M, could be inserted into them. A Tin filter is used to eliminate the overestimated signals in low-energy photons below 100 keV. The measurement uncertainty of the RPLGD reader system based on GD-352M should be analyzed for obtaining reliable protection quantities before using it for practical applications. Generally, the measurement uncertainty of RPLGD systems without Tin filters is analyzed for quality assurance of radiotherapy units using a high-energy photon beam. However, in this study, the measurement uncertainty of GD-352M was analyzed for evaluating the protection quantities. The measurement uncertainty factors in the RPLGD include the reference irradiation, regression curve, reproducibility, uniformity, energy dependence, and angular dependence, as described by the International Organization for Standardization (ISO). These factors were calculated using the Guide to the Expression of Uncertainty in Measurement method, applying ISO/ASTM standards 51261(2013), 51707(2015), and SS-ISO 22127(2019). The measurement uncertainties of the RPLGD reader system with a coverage factor of k = 2 were calculated to be 9.26% from 0.005 to 1 Gy and 8.16% from 1 to 10 Gy. A blind test was conducted to validate the RPLGD reader system, which demonstrated that the readout doses included blind doses of 0.1, 1, 2, and 5 Gy. Overall, the En values were considered satisfactory.

A Discussion on Image Analysis in 18F-Florbetaben PET/CT (18F-Florbetaben PET/CT 검사에서 영상분석에 대한 고찰)

  • Choi, Yong-Hoon;Bahn, Young-Kag;Lim, Han-Sang;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.33-37
    • /
    • 2022
  • Purpose 18F-Florbetaben (FBB) Readings are made by visually comparing the signal strengths of gray matter and white matter. We intend to evaluate the usefulness of image analysis by comparing quantified image analysis with readout. Materials and Methods Based on the reading results, 100 patients were divided into a negative scan and a positive scan, and 300 MBq of FBB was injected, and images were taken 90 minutes later for 20 minutes. The equipment was a Discovery 600 (GE Healthcare, MI, USA). Four regions of interest (lateral temporal lobes, frontal lobes, posterior cingulate & precuneus, and parietal lobes) were established based on the amyloid reading standard provided by the manufacturer. For image analysis, SUVratio (SUVr) was calculated by dividing each SUVmean by the cerebellum, and the average SUVr in the entire area was performed. Statistical analysis analyzed the cutoff derivation through ROC Curve, the difference between groups in Independent sample t-test, and the degree of agreement with the reading result through Kappa test. Results The average SUVr cutoff in the entire area was 1.23. Concordance with the read results using cutoff was 95/100 (95%) for negative and 92/100 (92%) for positive. As a result of the t-test, there was a statistically significant difference between the groups (P < 0.05), and the Kappa statistical result showed a high degree of agreement with 0.867 (P < 0.05). Conclusion The results of image analysis were statistically significant and showed a high degree of agreement with the reading results. In addition, FBB image analysis can be viewed by 3D mapping the area where amyloid is accumulated, location estimation is possible, and quantitative analysis results can be viewed in detail. If quantified FBB image analysis is used as an auxiliary indicator, it is thought to be helpful in reading.

Evaluation of Dynamic X-ray Imaging Sensor and Detector Composing of Multiple In-Ga-Zn-O Thin Film Transistors in a Pixel (픽셀내 다수의 산화물 박막트랜지스터로 구성된 동영상 엑스레이 영상센서와 디텍터에 대한 평가)

  • Seung Ik Jun;Bong Goo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.359-365
    • /
    • 2023
  • In order to satisfy the requirements of dynamic X-ray imaging with high frame rate and low image lag, minimizing parasitic capacitance in photodiode and overlapped electrodes in pixels is critically required. This study presents duoPIXTM dynamic X-ray imaging sensor composing of readout thin film transistor, reset thin film transistor and photodiode in a pixel. Furthermore, dynamic X-ray detector using duoPIXTM imaging sensor was manufactured and evaluated its X-ray imaging performances such as frame rate, sensitivity, noise, MTF and image lag. duoPIXTM dynamic X-ray detector has 150 × 150 mm2 imaging area, 73 um pixel pitch, 2048 × 2048 matrix resolution(4.2M pixels) and maximum 50 frames per second. By means of comparison with conventional dynamic X-ray detector, duoPIXTM dynamic X-ray detector showed overall better performances than conventional dynamic X-ray detector as shown in the previous study.

Application of Potassium Feldspar pIR-IRSL Method to Dating Quaternary Marine and Fluvial Terrace Sediments in Korea: A Case Study on a Fluvial Terrace and Gusan Fault in Uljin, Korea (한반도 해안-하안단구 퇴적층에 대한 K 장석 pIR-IRSL연대측정법 적용가능성 고찰: 울진 하안단구와 구산단층 연대측정)

  • Hong, Seongchan;Choi, Jeong-Heon
    • The Journal of the Petrological Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.241-252
    • /
    • 2016
  • In this paper, in order to test the possibility of applying K feldspar $pIR-IRSL_{290}$ signal(read out at $290^{\circ}C$) to date old terrace sediments(up to ~ 200 ka, MIS 7) in Korea, we investigated luminescence properties of $pIR-IRSL_{290}$ signals in K feldspar extracts from 27 marine and fluvial terrace sediment samples, and these were compared with those of quartz OSL and conventional K feldspar $IRSL_{50}$ (readout at $50^{\circ}C$) signals. The averaged $2D_0$ value of K feldspar $pIR-IRSL_{290}$ growth curves was ~ 700 Gy, which is consistent with that of $IRSL_{50}$ signal, and this is 3 times higher than that for quartz OSL (~ 250 Gy) on average. Where possible, K feldspar $pIR-IRSL_{290}$ ages were compared with quartz OSL and conventional $IRSL_{50}$ ages. Our preliminary K feldspar $pIR-IRSL_{290}$ ages were older than quartz OSL ages by about 200%, while fading rate-corrected conventional $IRSL_{50}$ ages are in good agreement with those based on quartz OSL. This seems to indicate the possibility of K-feldspar $pIR-IRSL_{290}$ age overestimation due to the presence of unbleachable $pIR-IRSL_{290}$ signals, even with a prolonged exposure to sunlight. Both quartz OSL and K-feldspar $pIR-IRSL_{290}$ signals for the samples from Noeum fluvial terrace and Gusan fault site were all in dose saturation level, thus unable to estimate the formation ages of the sediments. However, $2D_0$ values derived from the dose response growth curves strongly indicate that the Noeum fluvial terrace sediments have formed before 109-140 ka, while the fluvial sediments from Gusan fault were desposited before 100-105 ka. Further, this seems to suggest that the previous quartz OSL ages of ~40-50 ka for Gusan fault sediments should be the underestimated ones due to dose saturation problem.