• Title/Summary/Keyword: reader

Search Result 1,487, Processing Time 0.03 seconds

A Study of the Accessibility Evaluation of the SI-Bass Guitar (플러그인 가상악기 SI-Bass Guitar의 접근성 평가 연구)

  • Yong-Hwan Seok
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.495-500
    • /
    • 2024
  • The purpose of this study is to evaluate the accessibility of the SI-Bass Guitar for the visually impaired who uses the Sense Reader which is a screen reader software. An evaluation was performed for the Sense Reader users to do the [Virtual Instrument Editing] task on the NCS(National Competency Standards) using the SI-Bass Guitar. This study shows that the SI-Bass Guitar has no basic accessibility. But the visually impaired can do above task using the Sense Reader's Mouse Pointer and Position Memory Function. Several Propositions are suggested to develop a fully accessible SI-Bass Guitar for the screen users.

Development of a Portable Card Reader for the Visually Impaired using Raspberry Pi (라즈베리 파이를 적용한 시각장애인을 위한 휴대용 카드 리더기 개발)

  • Lee, Hyun-Seung;Choi, In-Moon;Lim, Soon-Ja
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.131-135
    • /
    • 2017
  • We developed a portable card reader for the visually impaired. In South Korea, there is insufficient development of lifestyle aids for people with disabilities. Living aids for people with disabilities are being developed using information technology, smart phones, Internet of Things(IoT) devices, 3D printers, and so on. Blind people were interviewed, which showed that the card recognition function using a currently developed smart phone app was not able to recognize the screen of the smart phone by the hand of the visually impaired, and it was inconvenient to operate. In recent years, devices that enable the visually impaired to recognize cards have been studied in foreign countries and are emerging prototypes. But what is currently available is expensive and inconvenient. In addition, visually impaired people are most vulnerable to low-income families, which makes it difficult to purchase and use expensive devices. In this study, we developed a card reader that recognizes a card using a Raspberry Pi, which is an open-source hardware that can be applied to IoT. The card reader plays it by voice and vibration, and the visually impaired can use it at a low price.

Studies on use of milk progesterone EIA-kit for diagnosis of reproductive disorders and non-pregnancy in dairy cows (젖소의 번식장애 및 비임신진단을 위한 Milk Progesterone 측정 EIA-kit의 이용에 관한 연구)

  • Chung, Byung-hyun;Lee, Byeong-han;Kang, Young-sun;Kim, Jin-young;Nam, Hyoung-young;Lee, Kang-yeol;Hwang, Yoon-sik;Yang, Kwang-hun;Chung, Kil-saeng
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.1
    • /
    • pp.169-177
    • /
    • 1995
  • This study was carried out to investigate the effect, range of practice, and propriety for diagnosis of early non-pregnancies and reproductive disorders by dairy cows' milk progesterone analysis used EIA-kit of home products. The results were summarized as follows : 1. During 2 to 6 months after artificial insemination, the results of milk progesterone measurement by Home-kit and Auto ELISA reader-kit with pregnant dairy cows(152 heads) certified by rectal palpation were revealed, in Home-kit, 145 heads(95.4%) of positive reaction, 7 heads(4.6%) of quasi-positive, and 0 heads(0%) of negative among 152 heads and, in Auto ELISA reader-kit, 152 heads(100%) of positive reaction among 152 heads. 2. During 19 to 22 days after artificial insemination, the results of milk progesterone measurement by Home-kit, and thereafrer during 50 to 90 days after that, the results of pregnant test by rectal palpation were summarized as follows : 147 heads(82.1%) among 179 heads of positive reaction by Home-kit and 5 heads(31.3%) among 16 heads of quasi-positive were revealed pregnant cows by rectal palpation, and 42 heads(100%) among 42 heads of negative were non-pregnant. 3. During 19 to 22 days after artificial insemination, the results of milk progesterone measurement by Auto ELISA reader-kit, and thereafrer during 50 to 90 days after that, the results of pregnant test by rectal palpation were summarized as follows : 146 heads(86.9%) among 168 heads of positive reaction by Auto ELISA reader-kit and 6 heads(28.6%) among 21 heads of quasi-positive were revealed pregnant cows by rectal palpation, and 48 heads (100%) among 48 heads of negative were non-pregnant. 4. For the accuracy of the rectal palpation, Home-kit and Auto ELISA reader-kit were used in the cows of ovarian diseases. The results were following : in the cows of reproductive disorders expected negative milk progesterone, the accuracies of rectal palpation were the same 75.5%(40 heads among 53 heads) by Home-kit and Auto ELISA reader-kit, and in the cows of reproductive disorders expected positive milk progesterone, the accuracies of rectal palpation were 82.6%(19 heads among 23 heads) and 91.3%(21 heads among 23 heads) by Home-kit and Auto ELISA reader-kit, respectively, and the general accuracies of rectal palpation were 77.6%(59 heads among 76 heads) and 80.3%(61 heads among 76 heads) by Home-kit and Auto ELISA reader-kit, respectively.

  • PDF

Study on Characteristics of the Forward Link Signal for the UHF RFID Reader (UHF 대역 RFID 리더의 순방향 링크 신호 특성에 관한 연구)

  • Kim, Do-Yun;Jang, Byung-Jun;Yoon, Hyun-Goo;Park, Jun-Seok;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.6 s.121
    • /
    • pp.602-611
    • /
    • 2007
  • In this paper, the forward link of UHF RFID system is modeled in accordance with the EPCglobal class 1 generation 2(EPCglobal C1G2) UHF Radio-Frequency Identity protocol specification at $860{\sim}960MHz$. Based on the constructed model, characteristics on the forward link signal for the EPCglobal C1G2 RFID reader are simulated with the help of a MATLAB softwarein order to extract the design parameters of a transmit digital filter which meets the Korean RFID regulations. Herein, the forward link model is consisted of PIE source coding, transmit digital filter, modulation, local oscillator, and antenna. From the simulation results, the ranges of three design parameters(roll-off factor, cutoff frequency, the number of tabs) for transmit digital filter are obtained with different modulation techniques and the Tari(type a reference interval) values. Finally, DSB/SSB-ASK modulation technique can not satisfy the EPCglobal C1G2 specification when Tari equals to $6.25{\mu}sec$ in a multiple-reader environment. Consequently this paper can provide a guideline for design parameters of a RFID reader as well as the basic scheme of analyzing frequency interference problems in RFID environments, including multiple-reader and dense-reader environments.

Development of OSL Dosimetry Reader (선량 판독용 OSL 측정장치의 개발)

  • Park, Chang-Young;Chung, Ki-Soo;Lee, Jong-Duk;Chang, In-Su;Lee, Jung-Il;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.10-15
    • /
    • 2012
  • Design and performance test results of a newly developed optically stimulated luminescence (OSL) measurement system are presented in this paper. Generally, different types of optical filters are used in OSL reader system to minimize the interference of the stimulation light in the OSL signal. For optically stimulation of $Al_2O_3:C$, we have arrived at an optimal combination of the filters, i.e., GG420 filter for filtering the stimulating light source, and a combined UG11 and BG39 filter at the detecting window (PMT). By using a high luminance blue LED (Luxeon V), sufficient luminous intensity could be obtained for optically stimulation. By using various control boards, the OSL reader device was successfully interfaced with a personal computer. A software was developed to deliver required commands to operate the OSL reader by using the LabView program (National Instruments, Inc.). In order to evaluate the reliability and the reproducibility of newly designed-OSL reader. Performance testing of the OSL reader was carried out for OSL efficiency, OSL decay curve and signal to noise ratio of the standard $Al_2O_3:C$ OSL material. It was found to be comparable with that of commercial Riso reader system.

A Study on the Magnetic Field Improvement for 13.56MHz RFID Reader Antenna (13.56MHz RFID 리더 안테나의 자계 필드 개선에 관한 연구)

  • Kim, Hyuck-Jin;Yang, Woon-Geun;Yoo, Hong-Jun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.1 s.343
    • /
    • pp.1-8
    • /
    • 2006
  • In this paper, we suggested a new antenna structure for the RFID(Radio Frequency IDentification) reader. The conventional RFID reader uses a loop antenna. The central area of a loop antenna shows a low magnetic field strength, especially for the case of a large loop antenna diameter. We proposed a parallel-fed multiple loop antenna. Simulation and measurement were carried out for a single loop antenna, series-fed and parallel-fed multiple loop antennas. Simulation results show that we can obtain 0.40A/m, 0.68A/m, 1.98A/m of magnetic field strengths at the central point of a reader antenna for a single loop antenna, series-fed and parallel-fed multiple loop antennas, respectively. We measured the $79mm{\time}48mm$ tag area averaged induced voltages with applying 20Vp-p same source signals to reader antennas through the resistors. Measured tag area averaged induced voltages at the central point of a reader antennas were 0.76V, 1.45V, 4.04V for a single loop antenna series-fed and parallel-fed multiple loop antennas, respectively. The results show that we can get high induced voltage which can grantee a longer reading distance with a proposed parallel-fed multiple loop antenna.

Knowledge as Marketing Message : Design and Analysis of Human-Reader Based Personal Experience Management Business Model (마케팅 메시지로서의 지식 : Human-Reader 기반의 개인 경험 관리 비즈니스 모델 설계 및 분석)

  • Jun, Jung-Ho;Lee, Kyoung-Jun
    • Journal of Intelligence and Information Systems
    • /
    • v.16 no.1
    • /
    • pp.17-43
    • /
    • 2010
  • This research considers the role of knowledge as marketing message, designs and analyses the personal experience management (PEM) business model using Human-Reader system. It is difficult to save and manage person's daily experience and relevant contents due to the lack of proper infrastructure and system. On the contrary, using Human-Reader infrastructure, person's experience and various relevant contents can be easily saved and managed because seamlessness between offline and online and the various devices that person can always carry along in ubiquitous environment. Since person can store and manage information, contents and advertisements through Human-Reader system and u-PEMS, marketing messages and advertisements do not have to be repetitive and stimulating. Instead, marketing messages and advertisements in Human-Reader environment should be granting values that can be saved and managed. We propose various scenarios, processes and its issues. And we analyze the expected value of RFID tag used on the proposed business model by so-called 'Tag Evaluation Model' and assess the assumptions that are basis of the proposed business model for evaluate the feasibility of the u-PEM business model.

Interpretation of Complete Tumor Response on MRI Following Chemoradiotherapy of Rectal Cancer: Inter-Reader Agreement and Associated Factors in Multi-Center Clinical Practice

  • Hae Young Kim;Seung Hyun Cho;Jong Keon Jang;Bohyun Kim;Chul-min Lee;Joon Seok Lim;Sung Kyoung Moon;Soon Nam Oh;Nieun Seo;Seong Ho Park
    • Korean Journal of Radiology
    • /
    • v.25 no.4
    • /
    • pp.351-362
    • /
    • 2024
  • Objective: To measure inter-reader agreement and identify associated factors in interpreting complete response (CR) on magnetic resonance imaging (MRI) following chemoradiotherapy (CRT) for rectal cancer. Materials and Methods: This retrospective study involved 10 readers from seven hospitals with experience of 80-10210 cases, and 149 patients who underwent surgery after CRT for rectal cancer. Using MRI-based tumor regression grading (mrTRG) and methods employed in daily practice, the readers independently assessed mrTRG, CR on T2-weighted images (T2WI) denoted as mrCRT2W, and CR on all images including diffusion-weighted images (DWI) denoted as mrCRoverall. The readers described their interpretation patterns and how they utilized DWI. Inter-reader agreement was measured using multi-rater kappa, and associated factors were analyzed using multivariable regression. Correlation between sensitivity and specificity of each reader was analyzed using Spearman coefficient. Results: The mrCRT2W and mrCRoverall rates varied widely among the readers, ranging 18.8%-40.3% and 18.1%-34.9%, respectively. Nine readers used DWI as a supplement sequence, which modified interpretations on T2WI in 2.7% of cases (36/1341 [149 patients × 9 readers]) and mostly (33/36) changed mrCRT2W to non-mrCRoverall. The kappa values for mrTRG, mrCRT2W, and mrCRoverall were 0.56 (95% confidence interval: 0.49, 0.62), 0.55 (0.52, 0.57), and 0.54 (0.51, 0.57), respectively. No use of rectal gel, larger initial tumor size, and higher initial cT stage exhibited significant association with a higher interreader agreement for assessing mrCRoverall (P ≤ 0.042). Strong negative correlations were observed between the sensitivity and specificity of individual readers (coefficient, -0.718 to -0.963; P ≤ 0.019). Conclusion: Inter-reader agreement was moderate for assessing CR on post-CRT MRI. Readers' varying standards on MRI interpretation (i.e., threshold effect), along with the use of rectal gel, initial tumor size, and initial cT stage, were significant factors associated with inter-reader agreement.