• 제목/요약/키워드: ray-fan

검색결과 76건 처리시간 0.023초

홍채인식용 광학계 설계 (Optical system design for recognition of human iris)

  • 홍경희
    • 한국광학회지
    • /
    • 제11권6호
    • /
    • pp.390-394
    • /
    • 2000
  • 사람의 홍채 인식을 통항 보안 통제를 하기 위한 광학계를 설계하였다. 이 렌즈는 종색수차와 Petzval sum을 최소로 하는 triplet형이다. 초점거리를 50mm 유효경을 10mm로 하였고 물체로부터 상까지의 거리는 200mm-300mm로 고려하였다. 눈을 고려한 전체 광학계의 성능은 ray-fan과 spot diagram 그리고 회절광학적인 MTF를 계산하여 평가하였다. 홍채의 크기를 고려하여 물체 높이 0mm, 4mm 그리고 6mm 에 대하여, 파장은 Fraunhofer C, d 및 F-line에 대하여 모두 계산한 결과 spot 크기는 0.05mm 직경을 벗어나지 않았고 MTF 값도 물체 높이 6mm에 대한 486mm 파장의 sagittal MTF를 제외하고는 20 lines/mm의 공간주파수에서 0.5이상이 되었다.

  • PDF

Explainable radionuclide identification algorithm based on the convolutional neural network and class activation mapping

  • Yu Wang;Qingxu Yao;Quanhu Zhang;He Zhang;Yunfeng Lu;Qimeng Fan;Nan Jiang;Wangtao Yu
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4684-4692
    • /
    • 2022
  • Radionuclide identification is an important part of the nuclear material identification system. The development of artificial intelligence and machine learning has made nuclide identification rapid and automatic. However, many methods directly use existing deep learning models to analyze the gamma-ray spectrum, which lacks interpretability for researchers. This study proposes an explainable radionuclide identification algorithm based on the convolutional neural network and class activation mapping. This method shows the area of interest of the neural network on the gamma-ray spectrum by generating a class activation map. We analyzed the class activation map of the gamma-ray spectrum of different types, different gross counts, and different signal-to-noise ratios. The results show that the convolutional neural network attempted to learn the relationship between the input gamma-ray spectrum and the nuclide type, and could identify the nuclide based on the photoelectric peak and Compton edge. Furthermore, the results explain why the neural network could identify gamma-ray spectra with low counts and low signal-to-noise ratios. Thus, the findings improve researchers' confidence in the ability of neural networks to identify nuclides and promote the application of artificial intelligence methods in the field of nuclide identification.

Development of Diode Based High Energy X-ray Spatial Dose Distribution Measuring Device

  • Lee, Jeonghee;Kim, Ikhyun;Park, Jong-Won;Lim, Yong-Kon;Moon, Myungkook;Lee, Sangheon;Lim, Chang Hwy
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.97-106
    • /
    • 2018
  • Background: A cargo container scanner using a high-energy X-ray generates a fan beam X-ray to acquire a transmitted image. Because the generated X-rays by LINAC may affect the image quality and radiation protection of the system, it is necessary to acquire accurate information about the generated X-ray beam distribution. In this paper, a diode-based multi-channel spatial dose measuring device for measuring the X-ray dose distribution developed for measuring the high energy X-ray beam distribution of the container scanner is described. Materials and Methods: The developed high-energy X-ray spatial dose distribution measuring device can measure the spatial distribution of X-rays using 128 diode-based X-ray sensors. And precise measurement of the beam distribution is possible through automatic positioning in the vertical and horizontal directions. The response characteristics of the measurement system were evaluated by comparing the signal gain difference of each pixel, response linearity according to X-ray incident dose change, evaluation of resolution, and measurement of two-dimensional spatial beam distribution. Results and Discussion: As a result, it was found that the difference between the maximum value and the minimum value of the response signal according to the incident position showed a difference of about 10%, and the response signal was linearly increased. And it has been confirmed that high-resolution and two-dimensional measurements are possible. Conclusion: The developed X-ray spatial dose measuring device was evaluated as suitable for dose measurement of high energy X-ray through confirmation of linearity of response signal, spatial uniformity, high resolution measuring ability and ability to measure spatial dose. We will perform precise measurement of the X-ray beamline in the container scanning system using the X-ray spatial dose distribution measuring device developed through this research.

High Energy Observational Investigations of Supernova Remnants and their Interactions with Surroundings

  • Hui, Chung-Yue
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권3호
    • /
    • pp.127-132
    • /
    • 2013
  • Here we review the effort of Fermi Asian Network (FAN) in exploring the supernova remnants (SNRs) with state-of-art high energy observatories, including Fermi Gamma-ray Space Telescope and Chandra X-ray Observatory, in the period of 2011- 2012. Utilizing the data from Fermi LAT, we have discovered the GeV emission at the position of the Galactic SNR Kes 17 which provides evidence for the hadronic acceleration. Our study also sheds light on the propagation of cosmic rays from their acceleration site to the intersteller medium. We have also launched an identification campaign of SNR candidates in the Milky Way, in which a new SNR G308.3-1.4 have been uncovered with our Chandra observation. Apart from the remnant, we have also discovered an associated compact object at its center. The multiwavelength properties of this X-ray source suggest it can possibly be the compact binary that survived a supernova explosion.

Restoration of Chest X-ray by Kalman Filter

  • Kim, Jin-Woo
    • Journal of information and communication convergence engineering
    • /
    • 제8권5호
    • /
    • pp.581-585
    • /
    • 2010
  • A grid was sandwiched between two cascaded imaging plates. Using a fan-beam X-ray tube and a single exposure scheme, the two imaging plates, respectively, recorded grid-less and grid type information of the object. Referring to the mathematical model of the Grid-less and grid technique, it was explained that the collected components whereas that of imaging plates with grid was of high together with large scattered components whereas that of imaging plate with grid was of low and suppressed scattered components. Based on this assumption and using a Gaussian convolution kernel representing the effect of scattering, the related data of the imaging plates were simulated by computer. These observed data were then employed in the developed post-processing estimation and restoration (kalman-filter) algorithms and accordingly, the quality of the resultant image was effectively improved.

소형 물체의 검사를 위한 고해상도 미세 초점 X선 단층 촬영 시스템 (High Resolution Computerized Tomography System Using the Microfocus X-Ray for Inspection of Small Specimens)

  • 김영주;구자용;이승석;김환우
    • 비파괴검사학회지
    • /
    • 제18권3호
    • /
    • pp.181-190
    • /
    • 1998
  • 광원의 직경이 $5{\mu}m$ 수준인 X-선을 이용하여 미세 초점 X-선 단층촬영장치(computerized tomography system)를 제작하고 제어 및 계산 프로그램을 개발하였다. 본 장치는 비파괴검사용으로서 직경 20mm 이내의 시험체를 검사할 수 있다. 단층영상을 얻기 위한 계산 알고리즘으로서는 convolution back projection 알고리즘을 사용하였으며 광원의 형상을 평행 빔과 부채꼴 빔(fan beam) 등 두 종류를 사용하여 결과를 비교하였다. 장치의 제어 및 계산은 개인용 컴퓨터에서 동작하도록 하였다. 제작된 CT 장치와 프로그램을 이용하여 제작된 시편에 대하여 단층 영상을 복원하고 시편의 내부 구조 및 결함을 관찰하였다. 단층영상을 얻은 결과 실제 모습과 일치하는 재료내부의 결함에 대한 정보를 얻을 수 있었으며 해상도는 $20{\sim}30{\mu}m$정도인 것으로 판단되었다.

  • PDF

Comparison of Bone Mineral Density with Pencil Beam and Fan Beam DXA Machine

  • Park, Jeong-Hoon;Lee, Jae-Mun;Youn, Je-Woong;Suh, Tae-Suk;Lee, Heung-Kyu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.425-426
    • /
    • 2002
  • The bone densitometer is to investigate the bone mineral content and density for the osteoporosis assessment by using dual energy X-ray photons. For the clinical verification of the ISOL's OSTEO plus, the clinical study was performed with healthy and non-menopausal 30 female volunteers. The fan-beam DXA machine (Lunar, Expert) was chosen as a reference. After correlation analysis of their bone mineral densities, a strong correlation was obtained. From the results, it is claimed that the new forearm bone densitometer is clinically useful in osteoporosis diagnosis.

  • PDF

Spider Invasion Across the Galaxy

  • Hui, Chung-Yue
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권2호
    • /
    • pp.101-120
    • /
    • 2014
  • The nature of the exotic stellar corpses which reincarnate by consuming their companion is reviewed. Apart from sucking life from their partners, they are actually eating the doomed companions away by their deadly and powerful particle/radiation beams. Such situation resembles that a female "black widow" spider that eats its mate after mating. These celestial zombies are called - Millisecond pulsars (MSPs). In this review article, I will focus on the effort of Fermi Asian Network (FAN) in exploring these intricating objects over the last five years. Two special classes of MSPs are particularly striking. Since Fermi Gamma-ray Space Telescope has started surveying the gamma-ray sky, the population of "black widows" has been boosted. Another dramatic class is so-called "redbacks" (Australian cousin of "black widows") which has just emerged in the last few years. These MSPs provide us with a long-sought missing link in understanding the transition between accretion-powered and rotation-powered systems. The strategy of hunting MSPs through mulitwavelength observations of the unidentified Fermi objects is also reviewed.

Micro lens array 설계 (Design of micro lens array)

  • 홍경희
    • 한국광학회지
    • /
    • 제5권2호
    • /
    • pp.204-211
    • /
    • 1994
  • 팩시밀이나 복사기용으로 이용되는 micro lens array를 설계하였다. array 형태는 육각형배열이고 유효경은 0.160mm, 가장 가까운 이웃렌즈의 중심간 거리는 0.192mm로 하였다. 결상계의 횡배율은 1.0이다. single layer는 working distance가 10.55mm, double layer는 working distance가 7.90mm가 되었다. 각각의 성능은 ray fan을 계산하여 그 특성을 조사하였으며 서로 비교하였다.

  • PDF

A Convenient Method to Prepare Ag Deposited N-TiO2 Composite Nanoparticles via NH3 Plasma Treatment

  • Hu, Shaozheng;Li, Fayun;Fan, Zhiping
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권7호
    • /
    • pp.2309-2314
    • /
    • 2012
  • Ag deposited N-$TiO_2$ composite nanoparticles were prepared via $NH_3$ plasma treatment. X-ray diffraction, UV-vis spectroscopy, photoluminescence, and X-ray photoelectron spectroscopy were used to characterize the prepared $TiO_2$ samples. The plasma treatment did not change the phase composition and particle sizes of $TiO_2$ samples, but extended its absorption edges to the visible light region. The photocatalytic activities were tested in the degradation of an aqueous solution of a reactive dyestuff, methylene blue, under visible light. The photocatalytic activities of Ag deposited N-$TiO_2$ composite nanoparticles were much higher than Ag-$TiO_2$, N-$TiO_2$, and P25. A possible mechanism for the photocatalysis was proposed.