• Title/Summary/Keyword: ray following

Search Result 631, Processing Time 0.031 seconds

The review on the need for early screening of scoliosis (척추측만증 조기검진의 필요성)

  • Gong, Sang-Eun;Oh, Min-Seok
    • Journal of Haehwa Medicine
    • /
    • v.20 no.1
    • /
    • pp.137-142
    • /
    • 2011
  • Objective : The purpose of this study was to review on the need for early screening of scoliosis. Methods : We have researched and analyzed theories and literatures of scoliosis screening program. Result : The following results were obtained in this study. 1. Scoliosis screening should be carried out to improve middle and high school students's health and learning abilities. 2. The methods are the forward bending test, Moire test and X-Ray. 3. After the examination held by differentiating the degree of scoliosis, surgery or brace treatment for students should be carried out. 4. After the examination, appropriate acupuncture, exercise therapy and orthodontic treatment for students should be carried out. 5. Spinal health courses for young people should be held regularly to equip and encourage a healthy body and healthy mind and contribute to improve the learning efficiency. Conclusion : Scoliosis screening and early detection should be done in the Daejeon city middle school or high school students, and appropriate treatment should be performed as soon as possible.

The photo-removal Characteristic of NOx by photocatalyst/scoria/loess concrete (광촉매가 첨가된 스코리아/황토 콘크리트의 NOx 제거 특성)

  • Ko, Seong-Hyun;Lee, Jae-Hoon;Hong, Chong-Hyun;Ryu, Soong-Phil;Kim, Moon-Hoon;Moon, Kyung-Jong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.593-596
    • /
    • 2006
  • The environment-friendly building material, photocatalyst/scoria/loess concrete, was prepared using scoria and loess (which have merits as building materials) and photocatalyst (which has the functions to compose the environmental contaminants and of self cleaning). In order to apply this material as a building material, the compressive and flexible strengths, and water absorptivity (which have been set by Korea Industrial Standard) were measured. In order to know the environment-friendly characteristics of this material, several tests, such as, the tests of emissivity and emission power of far infrared ray and acoustic absorptivity, antibacterial test for Escherichia coli and Pseudomonas aeruginosa, antifungal test for mixed fungal strains, and deodorization test of ammonia were carried out. Moreover, the removal characteristics of NOx, and formaldehyde (HCHO) by photocatalyst/scoria/loess concrete were examined as the following different parameters: the removal characteristics of these contaminants with the substitution ratio and the kind of photocatalyst, light source, UV intensity of sunlight, relative humidity, intial NOx concentration.

  • PDF

Development of Petroleum-Based Carbon Composite Materials Containing Graphite/silicon Particles and Their Application to Lithium Ion Battery Anodes

  • Noh, Soon-Young;Kim, Young-Hoon;Lee, Chul-Wee;Yoon, Song-Hun
    • Journal of Electrochemical Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.116-123
    • /
    • 2011
  • Herein, a novel preparation method of highly homogeneous carbon-silicon composite materials was presented. In contrast to conventional solvent evaporation method, a milled silicon-graphite or its oxidized material were directly reacted with petroleum-derived pitch precursor. After thermal reaction under high pressure, pitch-graphite-silicon composite was prepared. Carbon-graphite-silicon composite were prepared by an air-oxidization and following carbonization. From energy dispersive spectroscopy, it was observed that small Si particles were highly embedded within carbon, which was confirmed by disappearance of Si peaks in Raman spectra. Furthermore, X-ray diffraction and Raman spectra revealed that carbon crystallinity decreased when the strongly oxidized silicon-graphite was added, which was probably due to oxygen-induced cross-linking. From the anode application in lithium ion batteries, carbon-graphite-silicon composite anode displayed a high capacity ($565\;mAh\;g^{-1}$), a good initial efficiency (68%) and an good cyclability (88% retention at 50 cycles), which were attributed to the high dispersion of Si particles within cabon. In case of the strongly oxidized silicongraphite addtion, a decrease of reversible capacity was observed due to its low crystallinity.

Analysis of Asbestos Fiber in Lungs by Transmission Electron Microscopy According to the Digestion Method (회화방법에 따른 폐 내 석면섬유의 투과전자현미경 분석)

  • Han, Jeong Hee;Chung, Young Hyun;Yang, Jung Sun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.333-340
    • /
    • 2013
  • Objectives: This study was designed to establish an accurate analytical method for asbestos in a biological sample for determining occupational asbestos-related diseases and relief of the health effects of environmental asbestos. Methods: Biological samples were obtained from lungs of rats following intratracheal instillation of asbestos(Chrysotile, anthophyllite) and were prepared according to digestion method(Wet digestion, high temperature ashing, low temperature ashing). The samples were then analyzed for asbestos fibers using a transmission electron microscope equipped with an energy dispersive X-ray spectrometer. Results: Low temperature plasma ashing removed more of the organic components and reduced fiber loss compared to the wet digestion method, making specimens so prepared more suitable for transmission electron microsocpy. Conclusions: The low temperature ashing technique is the most accurate method for analyzing asbestos in biological samples.

Photoelectron Spectroscopy Studies of the Electronic Structures of Al/RbF and $Al/CaF_2$ Cathodes for $Alq_3$-based Organic Light-emitting Devices

  • Park, Yong-Sup;Lee, Jou-Hahn
    • Journal of Information Display
    • /
    • v.6 no.1
    • /
    • pp.28-32
    • /
    • 2005
  • The electronic structures of Al/RbF/tris-(8-hydroxyquinoline)aluminium ($Alq_3$) and $Al/CaF_2/Alq_3$interfaces were investigated using x-ray photoelectron spectroscopy (XPS) and ultraviolet photoelectron spectroscopy (UPS). For both systems, the UPS showed a significant valence band shift following the deposition of the thin fluoride layers on $Alq_3$. However, the formation of gap state in valence region and the extra peak N 1s core level spectra showed different trends, suggesting that the alkali fluoride and alkali-earth fluoride interlayer have different reaction mechanisms at the interface between Al cathode and $Alq_3$. In addition, the deposition of Al has considerably less effect on the valence band shift compared to the deposition of both RbF and $CaF_2$. These results suggest that the charge transfer across the interface and the resulting gap state formation may have lesser effect on the enhancement of organic light-emitting device performance than the observed valence band shift, which is thought to lower the electron injection barrier.

Fabrications and properties of ZnS thin film used as a buffer layer of electroluminescent device (전계발광소자 완충층용 ZnS 박막 제작 및 특성)

  • 김홍룡;조재철;유용택
    • Electrical & Electronic Materials
    • /
    • v.7 no.2
    • /
    • pp.117-122
    • /
    • 1994
  • The role of ZnS buffer layer not only suppresses chemical reactions between emission material and insulating material but also alters the luminescence and the crystallinity of the emission layer, if ZnS buffer layer was sandwiched between emission layer and insulating layer of electroluminescent device. In this research, we fabricated ZnS thin film with rf magnetron sputter system by varying rf power 100, 200W, substrate temperature 100, 150, 200, 250.deg. C and post-annealing temperature 200, 300, 400, 500.deg. C and analysed X-ray diffraction pattern, transmission spectra and cross section by SEM photograph for seeking the optimal crystallization condition of ZnS buffer layer. As a result, increasing the rf power, the crystallinity of ZnS thin film was improved. It was found that the ZnS thin film had better properties than anything else when fabricated with the following conditions ; rf power 200W, substrate temperature 150.deg. C, and post-annealing temperature 400.deg. C. ZnS thin film had the transmittance more than 80% in visible range. So it is suitable to use as a buffer layer of electroluminescent devices.

  • PDF

Reproduction of Traditionally-Refining Acupuncture Needle and Analysis of Surface-chemical Properties (전통 연침법(鍊鍼法)의 재현 및 침(鍼) 표면 변화의 분석)

  • Lee, Seung-Taek;Yu, Jeong-Ung;Kim, Ik-Jin;Cha, Wung-Seok
    • The Journal of Korean Medical History
    • /
    • v.26 no.2
    • /
    • pp.135-148
    • /
    • 2013
  • This study analyzed surface-chemical transitions in manufacturing process of traditional acupuncture as proposed method by Dongeuibogam. The manufacturing process of traditional acupuncture from a used iron for a long time was divided by primary medicinal herbs treatment, secondary medicinal herbs treatment and tertiary treatment using by dog meat. The traditional acupuncture research process was measured according to the characteristics and changes of the specimens at each processing step of the manufacturing process. The following devices were used to Surface analysis. Scanning electron microscopy (SEM), Energy Dispersive Spectrometer (EDS), X-ray diffraction analyzer (XRD). As a result, medicinal herbs removed impurities on the surface and raised the antibacterial effect in the manufacturing process of traditional acupuncture. Furthermore, the ingredients of medicinal herbs were coated on the surface of the iron. Dog meat influenced to prevent surface corrosion, reduce friction when the acupuncture was inserted. Although the process empirically obtained, a glimpse of the wisdom of our ancestors was revealed. These ancestral wisdom can be expected to apply today, when used in manufacturing process of a modern stainless steel acupuncture to compensate for the defective part.

Monte Carlo Simulation Based Digitally Reconstructed Radiographs

  • Kakinohana, Yasumasa;Ogawa, Kazuhiko;Toita, Takafumi;Murayama, Sadayuki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.436-438
    • /
    • 2002
  • As the use of virtual simulation expands, digitally reconstructed radiographs (DRRs), which mimic conventional simulation films, play an increasingly important role as reference images in the verification of treatment fields. The purpose of our study is to develop an algorithm for computation of digitally reconstructed radiographs based on Monte Carlo simulation that take into account almost all possible physical processes by which photons interact with matter. The Monte Carlo simulation based DRRs have the following features. 1) Account has been taken of almost all possible physical processes of interaction of photons with matter, including a detector (film) response. In principle, this is equivalent to X-ray radiography. 2) Arbitrary photon energies (from diagnostic to therapeutic) can be used to produce DRRs. One can even use electrons as the source. 3) It is easy to produce a double exposure, which mimics the double exposure portal image and may have superior visual appeal for treatment field verification, with weighting within the treatment field.

  • PDF

A Case of Cold Agglutinin Hemolytic Anemia Complicating Mycoplasma pneumoniae pneumonia in Children (소아에서 Mycoplasma pneumoniae pneumonia에 합병된 한냉응집소 용혈성 빈혈 1례)

  • Jo, Sung Ok;Park, Hyeon Jin
    • Pediatric Infection and Vaccine
    • /
    • v.5 no.2
    • /
    • pp.302-307
    • /
    • 1998
  • Hemolytic anemia due to cold agglutinin disease is a known complication of Mycoplasma pneumoniae infection but is rarely observed, particularly in children. A case of Mycoplasma pneumonia complicated with hemolytic anemia is presented. A 7 year-old girl was adimitted because of fever, cough, sputum and pale appearance. Chest X-ray showed pneumonic consolidation of Rt. upper lobe, lingular division. Laboratory studies disclosed the following values : Hb 5.3g/dL, Hct 11.1%, reticulocyte 2.9%, indirect Coombs test negative, direct Coombs test(monovalent) Anti-C3d positive, Anti-IgG negative, Anti-IgM negative, cold agglutinin titer 1 : 256, mycoplasma antibody titer 1 : 640, total bilirubin 1.0mg/dL. Initial PBS before wanning showed agglutination of red blood cells. The diagnosis of cold agglutinin hemolytic anemia complicating mycoplasma pneumonia was made. And treatment with roxithromycin, prednisolone and avoiding cold exposure was initiated, and complete recovery ensued. We report a case of cold agglutinin hemolytic anemia complicating mycoplasma pneumonia in children.

  • PDF

Successful Correction of Coarctation of the Aorta, the Patent Ductus Arteriosus, and Persistent Left Superior Vena Cava (대동맥축착 동맥관개존 좌공정맥을 합병한 다발성혈관기형의 수술치험예)

  • 김근호
    • Journal of Chest Surgery
    • /
    • v.7 no.1
    • /
    • pp.93-100
    • /
    • 1974
  • This is a case report of successful surgical correction of coarctation of the aorta associated with the patent ductus arteriosus and the persistent left superior vena cava. The patient was a 15 year old girl and congenital heart anomaly was suspected at the sixth month after birth. Afterward there has been no embarrassing symptoms until the day of operation except slight dyspnea on exertion, The diagnosis of coarctation of the aorta and the patent ductus arteriesus detected by physical signs and X-ray studies including aortography. In the first place, coarctation of the aorta was corrected with following procedure: partial resections of the aortic wall just above and below the coarctating line of the aorta and removal of diaphragmatic structure of coarctation performed by. cross clamping aorta above and below coarctation, and then the defect of the aortic wall was closed by lateral aortorrhapic suture with atraumatic needle 3-0 silk continuously [Fig. 6]. In the second place, the patent ductus arteriosus was closed with double ligation method. The persistent left superior vena cava left as it has been, because there has been no evidence of hemodynamic abnormal shunt. After operation, excellent result was obtained; blood pressure in the upper and lower extremities was normalized and subjective complains of hypertension in the upper extremity was disappeared.

  • PDF