• Title/Summary/Keyword: rated load

Search Result 314, Processing Time 0.042 seconds

Determination of Induction Motor equivalent circuit parameters by Inverter Source (인버터 전원에 의한 유도전동기 등가회로 결정)

  • Jeong, Young-Jun;Jwa, Chong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.160-162
    • /
    • 2001
  • A determining method of the $\Gamma$ type eqivalent circuit parameters of induction motor driven by inverter source is proposed in this paper. The no-load test by rated frequency (60 Hz) and a blocked rotor test by 25% of rated frequency (l5Hz) are performed with inverter source, and the DC resistance of the stator winding is measured. To determine the more accurate parameters, four simultaneous equations obtained from equivalent circuit of the no-load test and blocked rotor test are solved by using initial values which are evaluated from simplified equivalent circuits. The induction motor performances are computed by using these parameters and compared with measured values of the tested motor. Then it is found that the compared results show good agreement between them.

  • PDF

A Study on the Decision Algorithm of the Location of ESS for Power Distribution System (배전용 ESS 연계위치 결정 알고리즘에 관한 연구)

  • Hong, Soon-Il;Hwang, In-Sung;Moon, Jong-Fil;Jung, Won-Wook
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.37-41
    • /
    • 2018
  • In this paper, the ESS(Energy Storage System) is interconnected in order to reduce the maximum load in the distribution system and the target location of the ESS is set to be close to the rated voltage. We also applied the weights to nodes with large capacity and number of customers in the system. In the future, the interconnected location of the ESS was determined until 2029 in consideration of the load increase rated of the system. We propose a cooperative decision algorithm of interconnected location of ESS for Power Distribution System.

Neutral Line Current Analysis of Three-phase Four-wire Power System (3상 4선식 전력 시스템의 중성선 전류 분석)

  • Min Joon-Ki;Kim Hyng-Chul;Kim Su-Chel;Choi Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.492-494
    • /
    • 2006
  • Neutral line current is analyzed by the neutral line CF in nonlinear load balanced and unbalanced conditions. The worst nonlinear load condition is nonlinear balanced load condition, and It is below CFNL=1.194 that a neutral line current could not excess the rated value

  • PDF

Smokeless Starting for 4 Cycle Medium Speed Diesel Engine (4행정 중속 디젤기관의 스모크리스 시동)

  • Jung, Suk-Ho
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.11-16
    • /
    • 2014
  • Although smoke emitted from ships is not included in IMO(International Maritime Organiztion) regulation yet, it is one of the substance what is polluting mainly the air. Especially, its concentration is very high when an engine is started and a load is rapidly changed. This is caused by unburned fuel what is injected more than necessary quantity after combustion period. It is possible to decrease smoke concentration emitted at starting engine by controlling fuel injection quantity, but it is concerned that time to rated speed must be spent. Then a governor what can reduce the smoke concentration without a loss of time to rated speed is needed. We adopted a electro-hydraulic governor what can control dual fuel start limit function and achieved very low level of smoke concentration without greater the loss of time to rated speed.

10kW DC/DC Converter using Modified Series Loaded Resonant Topology (향상된 직렬 부하 공진형 컨버터 토폴로지를 이용한 10kW DC/DC 컨버터)

  • Ahn, Suk-Ho;Gong, Ji Woong;Jang, Sung-Roc;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.215-216
    • /
    • 2012
  • This paper proposes a modified converter topology from the existing loaded resonant converter and describe the development of 10kW(50~500V, 0~ 50A) DC/DC Converter using the proposed topology. The suggested converter, which revised the topology of the converter operating on the CCM(Continuous Conduction Mode) (above resonance), has the advantage of enhancing the efficiency of rated load operation by rapidly increasing the primary side resonant current and by improving the resonance current in a trapezoid shape. The proposed topology is described with analysis of operating mode and designed using PSpice simulation and the points on design to consider when implementing the topology are described. It is verified that the advantages of the proposed topology centered on rated load are effectively highlighted. Experimental results carried out at different condition and its results shows 98.5% efficiency at full load condition.

  • PDF

A Study on Rotor Eddy Current Loss and Thermal Analysis of PM Synchronous Generator for Wind Turbine (풍력터빈 PM형 동기발전기의 와전류손실과 열 해석에 관한 연구)

  • Choi, Man Soo;Chang, Young Hag;Park, Tae Sik;Jeong, Moon Seon;Moon, Chae Joo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1575-1581
    • /
    • 2014
  • In this paper, eddy current loss, iron loss and heat transfer of PMSG with 2,000kW capacities were analyzed for wind turbine. The PMSG with 3 split magnet was analyzed using ansoft maxwell commercial program and, generator was tested by Back to Back converter with no load condition at laboratory. Rotor surface temperature was measured by Pt100 sensors for investigating heat transfer from rotor to atmosphere. The simulation results shows 27.4kW eddy current loss in no load condition and 50.2kW eddy current loss in rated load condition with 3 split magnet, and also shows 4.3kW iron loss in no load condition and 7.3kW iron loss rated load condition. The heat transfer coefficient of convection between rotor surface and atmosphere was investigated by $9.6W/m^2{\cdot}K$. Therefore the heat transfer from rotor to atmosphere was about 17kW(54%) and from rotor to air-gap was about 14.6kW(46%) in no load condition. It is identified that the cooling system for stator have to include the 46% of iron loss, and heat dissipation structure of rotor surface have to be suggested and designed for efficiency improvement of generator.

Parameters Estimation Characteristics of Five-Phase Squirrel-Cage Induction Motor within Over Current Load (과전류 부하에서 5상 농형 유도전동기의 정수 특성)

  • Kim, Min-Huei
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.38-46
    • /
    • 2015
  • This paper propose a variable parameter estimations for variable over current load of five-phase squirrel-cage induction motor(IM) to servo control system. In order to high performance control of AC motor using a field oriented control(FOC) and direct torque control(DTC) algorithm, there are required precise motor parameters for slip calculation, flux observer, controller gain, torque command of current components, rotor position, speed estimation, and so on. We are suggest a analyzed estimation results of the motor parameters that developing five-phase squirrel-cage IM have a stator of concentrated winding for experimental within variable over current load at rated input frequency. There are results of stator winding measurement, no-load test, locked-rotor test, variable over current load test, and estimated parameters of equivalent circuits using manufactured experimental apparatus by IEEE Standard Test Procedure for Polyphase Induction Motors and Generators 112-2004.

A Study of Optimal Load Follow Control in Pressurized Water Reactors (감압경수형 원자로의 최적부하추종제어에 관한 연구)

  • 김락규;박상휘
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.12
    • /
    • pp.491-497
    • /
    • 1985
  • An applicaton of the linear optimal control theory to the problem or load follow control in pressurized water reactors (PWR) is investigated. In order to perform the steady-state and load follow operation in PWR, a nonlinear model for the reactor and steam generator is derived and linearized at 50% rated power. Simulation tests are performed for 10% demanded load. Comparing the dynamic response of the newly developed optimal load follow controller with those of the integral error feedback controller proposed by Yang, the rise time of dynamic response of the former is about 15 seconds faster than those of the latter, thus the results indicate that the fast response of the optimal load follow controller is verified. The results of this work are directly applicable to the design of the load follow control systems for commercially operated PWRs.

  • PDF

Induction Motor with Adjustable Windings for High Efficiency Drive in Light Load Operation

  • Zhang, Y.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.508-513
    • /
    • 2014
  • Heavy load start but light load operation is a common case in practical drive applications. When an induction motor is employed for such applications, its rated power is usually chosen according to the heavy load start. Then, during light load operation, its efficiency and power factor are low. To solve this problem, it is proposed to adjust the motor windings from the startup to the normal operation conditions. In this paper, arrangement of the adjustable windings is introduced, air gap field with different windings is investigated, and steady state operation performance under various loads is examined. It can be seen that by using proper winding arrangement both startup and operation performances are satisfactory.

Development of 6-axis Ankle Force/Moment Sensor for an Intelligent Foot of a Humanoid Robot (인간형 로봇의 지능형 발을 위한 6축 발목 힘/모멘트센서)

  • Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.1 s.190
    • /
    • pp.27-36
    • /
    • 2007
  • This paper describes the development of 6-axis ankle force/moment sensor for the intelligent feet of a humanoid robot. When the robot walks on uneven terrain, the feet should perceive the applied forces Fx, Fy, Fz and moments Mx, My, Mz from the attached 6-axis force/moment sensor on their ankles. Papers have already been published have some disadvantages in the size of the sensor, the rated output and so on. The rated output of each component sensor (6-axis ankle force/moment sensor) is very important to design the 6-axis force/moment sensor for precision measurement. Therefore, each sensor should be designed to get the similar rated output under each rated load. Also, the size of the sensor is very important for mounting to robot's feet. Therefore, the diameter should be below 100 mm and the height should be below 40mm. In this paper, first, the structure of a 6-axis ankle force/moment sensor was modeled for a humanoid robot's feet newly, Second, the equations to predict the strains on the sensing elements was derived, third, the size of the sensing elements was designed by using the equations, then, the sensor was fabricated by attaching straingages on the sensing elements, finally, the characteristic test of the developed sensor was carried out. The rated outputs from the derived equations agree well with the results from the experiments. The interference error of the sensor is less than 2.94%.